HomeMy WebLinkAboutBCE 026 - TrussesRe:
The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision
based on the parameters provided by ProBuild (CarterLee Bldg Components).
Miller, Scott
Pages or sheets covered by this seal: I31166265 thru I31166314
My license renewal date for the state of Indiana is July 31, 2018.
26_Bear_creek_estates
Truss Engineer’s responsibility is solely for
design of individual trusses based upon design parameters shown
on referenced truss drawings. Parameters have not been verified
as appropriate for any use. Any location identification specified is
for file reference only and has not been used in preparing design.
Suitability of truss designs for any particular building is the
responsibility of the building designer, not the Truss Engineer,
per ANSI/TPI-1, Chapter 2.
IMPORTANT NOTE:
26 Bear creek estates
16023 Swingley Ridge Rd
Chesterfield, MO 63017
314-434-1200
MiTek USA, Inc.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
GE01
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166265
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:50 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-GRfAGxgzW42z08UA_qxGxRsV?2v3m_GVB2OZvDyZqA?
Scale = 1:18.2
Sheet Back
Full Sheathing
1 Ply 7/16OSB8
1
2
3
4
7 6 5
3x6
2x4
2x4 2x4
2x4
-1-0-0
1-0-0
5-3-8
5-3-8
0-8-82-3-03.50 12
Plate Offsets (X,Y)-- [7:0-3-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.15
0.11
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.01
0.00
(loc)
1
1
5
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 32 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud *Except*
4-5: 2x3 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)7=207/5-3-8, 5=-27/5-3-8, 6=293/5-3-8
Max Horz 7=67(LC 5)
Max Uplift7=-44(LC 4), 5=-27(LC 1), 6=-34(LC 6)
Max Grav 7=207(LC 1), 5=6(LC 6), 6=293(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(10-11)
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Gable requires continuous bottom chord bearing.
4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5, 6.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
GE02
Truss Type
MONOPITCH SUPPORTED
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166266
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:50 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-GRfAGxgzW42z08UA_qxGxRsWl2wMm_sVB2OZvDyZqA?
Scale = 1:16.5
Sheet Front
Full Sheathing
1 Ply 7/16OSB8
1
2
3
5 4
2x4
2x4
2x4
2x4
-1-0-0
1-0-0
1-3-8
1-3-8
1-2-02-1-109.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.10
0.03
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
1
1
4
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud *Except*
3-4: 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-3-8 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing.
REACTIONS.(lb/size)5=148/1-3-8, 4=4/1-3-8
Max Horz 5=59(LC 5)
Max Uplift5=-39(LC 6), 4=-43(LC 5)
Max Grav 5=148(LC 1), 4=47(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(10-11)
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Gable requires continuous bottom chord bearing.
4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
GE03
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166267
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:50 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-GRfAGxgzW42z08UA_qxGxRsWL2wvmzaVB2OZvDyZqA?
Scale = 1:41.4
Sheet Front
Full Sheathing
1 Ply 7/16OSB8
1
2
3
4
5
6
7
8
9
10
11
20 19 18 17 16 15 14 13 12
2x4
2x4
4x6
2x4
2x4
2x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
10-11-0
10-11-0
-1-0-0
1-0-0
5-5-8
5-5-8
10-11-0
5-5-8
11-11-0
1-0-0
1-2-05-3-21-2-09.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.13
0.06
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
11
11
12
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 120 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 10-11-0.
(lb) - Max Horz 20=-128(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13
Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(11-12)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15,
14, 13.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
GE04
Truss Type
GABLE
Qty
2
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166268
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:51 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-kdDZUHhcHOAqeI3MYXSVUeOg4SGXVR6fQi77SfyZqA_
Scale = 1:18.0
Sheet Front
Full Sheathing
1 Ply 7/16OSB8
1
2
3
5 4
2x4
2x4
2x4
2x4
-1-0-0
1-0-0
1-11-8
1-11-8
1-1-02-4-118.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.13
0.03
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
1
1
4
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 15 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud *Except*
3-4: 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)5=160/1-11-8, 4=45/1-11-8
Max Horz 5=69(LC 5)
Max Uplift5=-30(LC 6), 4=-32(LC 5)
Max Grav 5=160(LC 1), 4=48(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(10-11)
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Gable requires continuous bottom chord bearing.
4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
GE05
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166269
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:51 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-kdDZUHhcHOAqeI3MYXSVUeOgkSFrVPSfQi77SfyZqA_
Scale = 1:55.8
Sheet Front
Full Sheathing
1 Ply 7/16OSB8
1
2
3
4
5
6
7
8
9
10
11
12
13
14 15
28 27 26 25 24 23 22 21 20 19 18 17 16
2x4
2x4
4x6
2x4
2x4
2x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
14-11-0
14-11-0
-1-0-0
1-0-0
7-5-8
7-5-8
14-11-0
7-5-8
15-11-0
1-0-0
1-2-06-9-21-2-09.00 12
Plate Offsets (X,Y)-- [2:0-3-9,0-1-4], [14:0-3-9,0-1-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.15
0.08
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
15
15
16
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 192 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 14-11-0.
(lb) - Max Horz 28=163(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except 28=-163(LC 4), 16=-131(LC
5), 27=-156(LC 5), 17=-134(LC 4)
Max Grav All reactions 250 lb or less at joint(s) 28, 16, 22, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(11-12)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 24, 25, 26, 21, 20,
19, 18 except (jt=lb) 28=163, 16=131, 27=156, 17=134.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
GE06
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166270
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:52 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-CqnxhciE2iIhGSeZ6F_k0sxkdrYJEloofMtgz5yZq9z
Scale = 1:94.4
Sheet Back
Right Option 9-1-8
1 Ply 7/16OSB8
12
3 4
5
6 7
8
9
19 18 17 16
14
13 12 11 10
15
3x6
4x6
3x4 3x6 3x8
3x4
3x4
3x4
3x4
5x6
2x4
5x6
2x4
2x4
2x4 2x4
3x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
5x6
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
6-5-0
6-5-0
12-7-8
6-2-8
14-11-0
2-3-8
16-1-8
1-2-8
18-10-0
2-8-8
25-3-0
6-5-0
-1-0-0
1-0-0
6-5-0
6-5-0
7-3-7
0-10-7
12-7-8
5-4-1
18-10-0
6-2-8
25-3-0
6-5-0
26-3-0
1-0-0
1-2-010-7-101-2-09.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [3:0-1-12,0-1-8], [6:0-3-0,0-3-0], [7:0-1-12,0-1-8], [8:0-3-0,0-1-12], [10:0-1-12,0-1-0], [21:0-1-15,0-0-8], [22:0-1-10,0-1-5], [22:0-0-6,0-1-3],
[33:0-1-10,0-0-0], [35:0-1-10,0-0-0], [36:0-1-10,0-0-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.59
0.32
0.61
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.04
-0.10
0.01
(loc)
18-19
18-19
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 342 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
2-19,8-10: 2x4 SPF-S Stud
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-16
REACTIONS.All bearings 10-7-8 except (jt=length) 19=0-3-8, 15=0-3-8.
(lb) - Max Horz 19=-253(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 19, 11, 10, 14, 15 except 12=-193(LC 2)
Max Grav All reactions 250 lb or less at joint(s) 14, 13, 15 except 19=809(LC 1), 11=975(LC 1), 10=353(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-843/100, 3-4=-499/122, 4-5=-376/162, 5-6=-376/162, 6-7=-500/122,
2-19=-752/120, 8-10=-297/89
BOT CHORD 18-19=-252/300, 17-18=-78/589, 16-17=-78/589
WEBS 7-16=-18/309, 7-11=-785/126, 3-16=-403/150, 2-18=0/427
NOTES-(9-10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable studs spaced at 1-4-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 11, 10, 14, 15
except (jt=lb) 12=193.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
GE07
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166271
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:53 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-g0LJvyisp?QYtbDlgyVzZ3U0QFxSzJayu0cEVXyZq9y
Scale: 1/4"=1’
Sheet Front
Full Sheathing
1 Ply 7/16OSB8
1
2
3
4
5
6
7
8
9
10
11
12
13
24 23 22 21 20 19 18 17 16 15 14
2x4
2x4
4x6
2x4
2x4
2x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
13-3-0
13-3-0
-1-0-0
1-0-0
6-7-8
6-7-8
13-3-0
6-7-8
14-3-0
1-0-0
1-2-06-1-101-2-09.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.14
0.07
0.13
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
13
13
14
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 160 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 13-3-0.
(lb) - Max Horz 24=148(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15
Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(11-12)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23,
18, 17, 16, 15.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
GE08
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166272
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:54 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-8Cvh6IjUZJYPVloxDf0C5H0B3fHfimX56gMn1_yZq9x
Scale = 1:49.8
Sheet Front
Full Sheathing
1 Ply 7/16OSB8
1
2
3
4
5
6
7
8
9
10
11
12
13
24 23 22 21 20 19 18 17 16 15 14
2x4
2x4
4x6
2x4
2x4
2x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
13-11-0
13-11-0
-1-0-0
1-0-0
6-11-8
6-11-8
13-11-0
6-11-8
14-11-0
1-0-0
1-2-06-4-101-2-09.00 12
Plate Offsets (X,Y)-- [2:0-2-0,0-0-12], [12:0-2-0,0-0-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.14
0.07
0.15
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.00
(loc)
13
13
14
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 172 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 13-11-0.
(lb) - Max Horz 24=154(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15
Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(11-12)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23,
18, 17, 16, 15.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
GE09
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166273
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:55 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-dOT3Jek6KdgG7vN7nNXReUZL53dEREAELK5KaQyZq9w
Scale = 1:84.5
Sheet Front
Full Sheathing
1 Ply 7/16OSB8
1 2
3
4 5 6
7
8
9
10
11
12
13
14 15 16 17 18 19 20 21
22
23
24
25
26
27
28
29
30
31
32 33
61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34
3x4
3x4
3x6
3x6
5x6
3x4
5x6
5x6
5x6
35-11-0
35-11-0
-1-0-0
1-0-0
14-8-13
14-8-13
21-2-3
6-5-6
35-11-0
14-8-13
36-11-0
1-0-0
1-1-010-10-141-1-010-10-148.00 12
Plate Offsets (X,Y)-- [15:0-4-8,0-2-8], [20:0-4-4,0-2-4], [30:0-2-12,0-3-4], [46:0-3-0,0-3-0], [49:0-3-0,0-0-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.25
0.11
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.01
(loc)
33
33
34
l/defl
n/r
n/r
n/a
L/d
180
120
n/a
PLATES
MT20
Weight: 745 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud
OTHERS 2x3 SPF No.2 *Except*
20-45,19-46,18-47,17-48,16-49,14-50: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals, and 2-0-0 oc purlins (10-0-0 max.): 15-20.
BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 20-45, 19-46, 18-47, 17-48, 16-49, 14-50,
13-51, 12-52, 21-44, 22-43
REACTIONS.All bearings 35-11-0.
(lb) - Max Horz 61=-259(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 49, 46, 47, 48, 51, 52, 53, 54, 55, 56, 57, 58, 59, 44, 43, 42,
41, 40, 39, 38, 37, 36 except 61=-205(LC 4), 34=-107(LC 5), 60=-190(LC 5), 35=-122(LC 4)
Max Grav All reactions 250 lb or less at joint(s) 61, 34, 49, 45, 46, 47, 48, 50, 51, 52, 53, 54, 55, 56, 57,
58, 59, 60, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 12-13=-22/260, 13-14=-20/289, 15-16=0/255, 16-17=0/256, 17-18=0/256, 18-19=0/256,
19-20=0/256, 20-21=-20/289, 21-22=-19/266
NOTES-(14-15)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 49, 46, 47, 48, 51,
52, 53, 54, 55, 56, 57, 58, 59, 44, 43, 42, 41, 40, 39, 38, 37, 36 except (jt=lb) 61=205, 34=107, 60=190, 35=122.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
14) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
15) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
GE10
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166274
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:57 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-ZnaqkKlMsEwzMDWWvoZvjveh5sIiu8gXoeaReJyZq9u
Scale = 1:83.1
Sheet Front
Full Sheathing
1 Ply 7/16OSB8
1 2
3
4
5
6
7
8
9
10
11
12 13 14 15 16 17 18
19
20
21
22
23
24
25
26
27
28
29 30
58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31
3x4
3x6
3x6
5x6
5x6
5x6
5x6
35-11-0
35-11-0
14-8-13
14-8-13
21-2-3
6-5-6
35-11-0
14-8-13
1-1-010-10-141-1-010-10-148.00 12
Plate Offsets (X,Y)-- [3:0-3-0,0-3-0], [13:0-4-8,0-2-8], [18:0-4-4,0-2-4], [43:0-3-0,0-3-0], [46:0-3-0,0-0-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.22
0.11
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.01
(loc)
-
-
31
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 742 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2
OTHERS 2x3 SPF No.2 *Except*
18-42,17-43,16-44,15-45,14-46,12-47: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals, and 2-0-0 oc purlins (6-0-0 max.): 13-18.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 18-42, 17-43, 16-44, 15-45, 14-46, 12-47,
11-48, 10-49, 19-41, 20-40
REACTIONS.All bearings 35-11-0.
(lb) - Max Horz 58=-256(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 46, 43, 44, 45, 48, 49, 50, 51, 52, 53, 54, 55, 56, 41, 40, 39,
38, 37, 36, 35, 34, 33 except 58=-185(LC 4), 31=-109(LC 5), 57=-160(LC 5), 32=-119(LC 4)
Max Grav All reactions 250 lb or less at joint(s) 58, 31, 46, 42, 43, 44, 45, 47, 48, 49, 50, 51, 52, 53, 54,
55, 56, 57, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 10-11=-30/257, 11-12=-28/286, 13-14=-6/253, 14-15=-5/253, 15-16=-5/253,
16-17=-5/253, 17-18=-5/253, 18-19=-28/286, 19-20=-28/263
NOTES-(14-15)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 46, 43, 44, 45, 48,
49, 50, 51, 52, 53, 54, 55, 56, 41, 40, 39, 38, 37, 36, 35, 34, 33 except (jt=lb) 58=185, 31=109, 57=160, 32=119.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
14) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
15) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
J01
Truss Type
Jack-Closed
Qty
6
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166275
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:57 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-ZnaqkKlMsEwzMDWWvoZvjvej_sJ?u9bXoeaReJyZq9u
Scale = 1:16.5
1
2
3
5
4
2x4
2x4
2x4
2x4
1-2-12
1-2-12
-1-0-0
1-0-0
1-3-8
1-3-8
1-2-02-1-101-10-20-3-82-1-109.00 12
Plate Offsets (X,Y)-- [4:0-2-1,0-0-10]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.10
0.03
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
5
5
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 7 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud *Except*
3-4: 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-3-8 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing.
REACTIONS.(lb/size)5=148/0-3-8, 4=4/0-1-8
Max Horz 5=59(LC 5)
Max Uplift5=-39(LC 6), 4=-43(LC 5)
Max Grav 5=148(LC 1), 4=47(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
J02
Truss Type
Jack-Open
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166276
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:58 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-1z8Cygm?dY2q_N5iSV58G7Bs9Gecdcrh1IK?AlyZq9t
Scale = 1:17.9
1
2
5
3
4
2x4
3x4
2-7-7
2-6-2
-1-4-1
1-4-1
2-7-7
2-7-7
1-0-152-4-90-4-111-11-152-4-95.98 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.20
0.07
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.00
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 9 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-7-7 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)5=213/0-5-4, 3=50/Mechanical, 4=20/Mechanical
Max Horz 5=82(LC 6)
Max Uplift5=-38(LC 6), 3=-28(LC 6)
Max Grav 5=213(LC 1), 3=50(LC 1), 4=44(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7-8)
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
J03
Truss Type
Jack-Open
Qty
8
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166277
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:58 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-1z8Cygm?dY2q_N5iSV58G7BtpGfjdcrh1IK?AlyZq9t
Scale = 1:18.2
1
2
5
3
42x4
3x4
2-0-0
2-0-0
-1-0-0
1-0-0
2-0-0
2-0-0
1-1-02-5-01-11-132-5-08.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.16
0.06
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.00
(loc)
5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 7 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)5=164/0-3-8, 3=37/Mechanical, 4=19/Mechanical
Max Horz 5=84(LC 6)
Max Uplift5=-11(LC 6), 3=-31(LC 6), 4=-3(LC 13)
Max Grav 5=164(LC 1), 3=37(LC 1), 4=47(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(9-10)
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 13 lb down at 1-11-14 on bottom
chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-3=-60, 4-5=-20
Concentrated Loads (lb)
Vert: 4=-4(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
J04
Truss Type
Jack-Closed
Qty
5
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166278
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:58 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-1z8Cygm?dY2q_N5iSV58G7BtJGfAdcrh1IK?AlyZq9t
Scale = 1:18.0
1
2
3
5
4
2x4
2x4
2x4
2x4
-1-0-0
1-0-0
1-11-8
1-11-8
1-1-02-4-112-1-30-3-82-4-118.00 12
Plate Offsets (X,Y)-- [4:0-1-15,0-0-10]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.13
0.03
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
5
5
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 8 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud *Except*
3-4: 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)5=160/0-3-8, 4=45/0-1-8
Max Horz 5=69(LC 5)
Max Uplift5=-30(LC 6), 4=-32(LC 5)
Max Grav 5=160(LC 1), 4=48(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
J05
Truss Type
Jack-Open Structural Gable
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166279
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:59 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-VAia90ndOrAhbWgv0DcNoKk1sg?GM35qGy3YjByZq9s
Scale = 1:17.7
1
2
5
3
4
2x4
3x4
2-4-9
2-4-9
-1-6-1
1-6-1
2-4-9
2-4-9
1-2-02-4-41-11-92-4-45.98 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.21
0.04
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.00
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 9 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-4-9 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)3=35/Mechanical, 5=224/0-7-7, 4=14/Mechanical
Max Horz 5=55(LC 6)
Max Uplift3=-20(LC 6), 5=-51(LC 6)
Max Grav 3=35(LC 1), 5=224(LC 1), 4=39(LC 2)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(9-10)
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Gable studs spaced at 2-0-0 oc.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
M01
Truss Type
Monopitch
Qty
5
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166280
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:59 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-VAia90ndOrAhbWgv0DcNoKkylgwOM3ZqGy3YjByZq9s
Scale = 1:20.9
1
2
3
5
4
2x4
3x6
2x4
6-4-0
6-4-0
-1-0-0
1-0-0
6-4-0
6-4-0
0-8-82-6-110-3-83.50 12
Plate Offsets (X,Y)-- [4:0-1-13,0-0-9], [5:0-3-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.53
0.35
0.03
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.13
-0.19
0.00
(loc)
4-5
4-5
l/defl
>574
>389
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 18 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
2-5: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)5=319/0-3-8, 4=237/0-1-8
Max Horz 5=76(LC 6)
Max Uplift5=-99(LC 4), 4=-82(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-5=-266/138
NOTES-(9-10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
M02
Truss Type
MONOPITCH
Qty
3
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166281
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:45:59 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-VAia90ndOrAhbWgv0DcNoKksYgvdM3FqGy3YjByZq9s
Scale = 1:24.7
1
2
3
5
4
2x4
4x8
2x4
8-4-0
8-4-0
-1-0-0
1-0-0
8-4-0
8-4-0
0-8-83-1-110-3-83.50 12
Plate Offsets (X,Y)-- [4:0-1-14,0-0-10]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.93
0.40
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.32
-0.48
0.00
(loc)
4-5
4-5
l/defl
>307
>204
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 23 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF 2100F 1.8E
WEBS 2x3 SPF No.2 *Except*
2-5: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-11-14 oc purlins,
except end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)5=397/0-3-8, 4=318/0-1-8
Max Horz 5=94(LC 6)
Max Uplift5=-119(LC 4), 4=-109(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-5=-332/159
NOTES-(9-10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) The Fabrication Tolerance at joint 5 = 16%
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=119,
4=109.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
MG01
Truss Type
Monopitch Girder
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166282
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:00 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-zMGyNMoF99IYDgF5aw7cLYG5r47W5WL_Vcp5FdyZq9r
Scale = 1:20.8
1
2
3
4 5
2x4
2x4
3x4
3x8
6-3-8
6-3-8
6-3-8
6-3-8
0-8-82-6-83.50 12
Plate Offsets (X,Y)-- [1:0-0-0,0-1-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.70
0.94
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.12
-0.32
0.00
(loc)
1-3
1-3
3
l/defl
>578
>223
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 25 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SP 2400F 2.0E
WEBS 2x4 SPF-S Stud
WEDGE
Left: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-3-8 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 5-0-0 oc bracing.
REACTIONS.(lb/size)3=1754/Mechanical, 1=1024/0-3-8
Max Horz 1=70(LC 4)
Max Uplift3=-100(LC 5), 1=-57(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(9-10)
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever
left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)
3=100.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 763 lb down and 40 lb up at 2-0-12,
and 763 lb down and 40 lb up at 4-0-12, and 772 lb down and 35 lb up at 6-1-12 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 1-3=-20
Concentrated Loads (lb)
Vert: 3=-772(F) 4=-763(F) 5=-763(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
PB01
Truss Type
GABLE
Qty
28
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166283
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:00 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-zMGyNMoF99IYDgF5aw7cLYGED4K65W4_Vcp5FdyZq9r
Scale = 1:19.2
2
3
4
6
1
5
4x6
2x4 2x4 2x4
6-5-6
6-5-6
3-2-11
3-2-11
6-5-6
3-2-11
2-1-130-1-40-1-88.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.10
0.07
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 6-5-6.
(lb) - Max Horz 1=-46(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 2, 4
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4, 6
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(11-12)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 4-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 2, 4.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
PBE01
Truss Type
GABLE
Qty
2
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166284
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:00 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-zMGyNMoF99IYDgF5aw7cLYGED4K65W4_Vcp5FdyZq9r
Scale = 1:19.2
Sheet Front
Full Sheathing
1 Ply 7/16OSB8
2
3
4
6
1
5
4x6
2x4 2x4 2x4
6-5-6
6-5-6
3-2-11
3-2-11
6-5-6
3-2-11
2-1-130-1-40-1-88.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.10
0.07
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 28 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 6-5-6.
(lb) - Max Horz 1=-46(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 2, 4
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4, 6
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(11-12)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 2, 4.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T01
Truss Type
Common
Qty
4
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166285
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:01 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-RYqLahptwTQPrqqH8eertlpHsUXaqpp7jGYfn4yZq9q
Scale = 1:65.8
1 2
3
4
5
6 7
11 10 9 8
4x6
3x8 3x8
3x4 3x4
3x4
4x6 4x6
3x4
9-11-8
9-11-8
19-11-0
9-11-8
-1-0-0
1-0-0
5-1-0
5-1-0
9-11-8
4-10-8
14-10-0
4-10-8
19-11-0
5-1-0
20-11-0
1-0-0
1-2-08-7-101-2-09.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.62
0.69
0.69
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.18
-0.47
0.02
(loc)
8-9
8-9
8
l/defl
>999
>506
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 83 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
2-11,6-8: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)11=854/0-3-8, 8=854/0-3-8
Max Horz 11=-206(LC 4)
Max Uplift11=-64(LC 6), 8=-64(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-289/101, 3-4=-710/130, 4-5=-710/130, 5-6=-289/101, 2-11=-333/125, 6-8=-333/125
BOT CHORD 10-11=-44/622, 9-10=-44/622, 8-9=0/622
WEBS 4-9=-60/501, 3-11=-631/29, 5-8=-631/29
NOTES-(7-8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 8.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T02
Truss Type
Common
Qty
4
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166286
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:01 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-RYqLahptwTQPrqqH8eertlpHrUXaqoN7jGYfn4yZq9q
Scale = 1:65.8
1 2
3
4
5
6
10 9 8 7
4x6
3x4
3x8 3x8
3x4 3x4
3x4
4x6 4x6
9-11-8
9-11-8
19-11-0
9-11-8
-1-0-0
1-0-0
5-1-0
5-1-0
9-11-8
4-10-8
14-10-0
4-10-8
19-11-0
5-1-0
1-2-08-7-101-2-09.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.62
0.69
0.72
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.18
-0.47
0.02
(loc)
8-10
8-10
7
l/defl
>999
>506
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 82 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
2-10,6-7: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)10=856/0-3-8, 7=783/0-3-8
Max Horz 10=217(LC 5)
Max Uplift10=-64(LC 6), 7=-28(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-289/101, 3-4=-713/130, 4-5=-714/131, 5-6=-269/70, 2-10=-333/125
BOT CHORD 9-10=-56/624, 8-9=-56/624, 7-8=-8/631
WEBS 4-8=-61/504, 3-10=-634/29, 5-7=-658/52
NOTES-(7-8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 7.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T03
Truss Type
Common
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166287
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:02 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-wlOjn1pVhmYGS_PUhL94QzMRLtt3ZJEGywICKWyZq9p
Scale = 1:65.8
1 2
3
4
5
9 8 7 6
4x6
5x6
3x8
3x4
2x4 3x8
3x4
4x6
0-0-1
0-0-1
9-11-8
9-11-7
16-9-11
6-10-3
16-11-8
0-1-13
-1-0-0
1-0-0
5-1-0
5-1-0
9-11-8
4-10-8
16-11-8
7-0-0
1-2-08-7-103-4-109.00 12
Plate Offsets (X,Y)-- [5:0-3-0,0-1-12], [9:0-2-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.70
0.67
0.49
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.22
-0.57
0.01
(loc)
7-9
7-9
6
l/defl
>891
>354
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 72 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
5-6,2-9: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)6=664/Mechanical, 9=738/0-3-8
Max Horz 9=244(LC 5)
Max Uplift6=-27(LC 6), 9=-59(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-298/98, 3-4=-533/123, 4-5=-567/104, 5-6=-614/72, 2-9=-340/125
BOT CHORD 8-9=-104/493, 7-8=-104/493
WEBS 4-7=-8/309, 5-7=-10/343, 3-9=-446/22
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 9.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T04
Truss Type
Common
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166288
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:02 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-wlOjn1pVhmYGS_PUhL94QzMTHt?dZQsGywICKWyZq9p
Scale = 1:41.4
1
2
3
4
7 6 5
5x6
4x6
2x4 2x4 3x8
5x6
5-5-8
5-5-8
10-11-0
5-5-8
5-5-8
5-5-8
10-11-0
5-5-8
11-11-0
1-0-0
1-2-05-3-21-2-09.00 12
Plate Offsets (X,Y)-- [1:0-3-0,0-1-12], [3:0-3-0,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.51
0.19
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.04
0.00
(loc)
6-7
6-7
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 43 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
1-7,3-5: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)7=421/0-3-8, 5=497/0-3-8
Max Horz 7=-138(LC 4)
Max Uplift7=-14(LC 6), 5=-50(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-412/66, 2-3=-418/70, 1-7=-373/64, 3-5=-450/104
NOTES-(7-8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T05
Truss Type
Common
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166289
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:02 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-wlOjn1pVhmYGS_PUhL94QzMSdtytZPtGywICKWyZq9p
Scale = 1:51.8
1
2
3
4
5
8 7 6
4x6
3x4 3x4 3x8
5x6 5x6
7-5-8
7-5-8
14-11-0
7-5-8
-1-0-0
1-0-0
7-5-8
7-5-8
14-11-0
7-5-8
15-11-0
1-0-0
1-2-06-9-21-2-09.00 12
Plate Offsets (X,Y)-- [2:0-1-12,Edge], [4:0-1-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.62
0.37
0.13
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.15
0.01
(loc)
6-7
6-7
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 60 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
2-8,4-6: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)8=654/0-3-8, 6=654/0-3-8
Max Horz 8=-163(LC 4)
Max Uplift8=-56(LC 6), 6=-56(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-600/83, 3-4=-600/83, 2-8=-589/118, 4-6=-589/118
BOT CHORD 7-8=-225/321, 6-7=-110/321
WEBS 3-7=0/301, 2-7=-89/252, 4-7=-94/257
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) The Fabrication Tolerance at joint 2 = 4%, joint 4 = 4%
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T06
Truss Type
Common
Qty
2
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166290
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:03 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-Oxy5?Nq7S4g748_gF2gJzAuauHCzIjDQBa1lsyyZq9o
Scale = 1:80.7
1 2
3
4
5
6
7
89
14 13 12 11 10151617181920
3x6
4x6
3x6
3x6 3x6
3x4
3x6
3x4
3x6
3x8 3x8
3x6
8-5-13
8-5-13
16-9-3
8-3-5
25-3-0
8-5-13
-1-0-0
1-0-0
6-5-0
6-5-0
12-7-8
6-2-8
18-10-0
6-2-8
25-3-0
6-5-0
26-3-0
1-0-0
1-2-010-7-101-2-09.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [4:0-1-12,0-1-8], [5:0-3-0,Edge], [6:0-1-12,0-1-8], [8:0-3-0,0-1-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.71
0.70
0.70
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.20
-0.31
0.05
(loc)
11-13
11-13
10
l/defl
>999
>961
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 117 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
5-11,5-13: 2x4 SPF No.2, 2-14,8-10: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-7-1 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-14, 6-10
REACTIONS.(lb/size)14=1272/0-3-8, 10=1272/0-3-8
Max Horz 14=-253(LC 4)
Max Uplift14=-73(LC 6), 10=-73(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-436/147, 4-5=-1358/229, 5-6=-1358/229, 7-8=-436/147, 2-14=-448/177, 8-10=-448/177
BOT CHORD 14-15=-45/1069, 15-16=-45/1069, 13-16=-45/1069, 13-17=0/761, 12-17=0/761, 12-18=0/761, 11-18=0/761,
11-19=0/1069, 19-20=0/1069, 10-20=0/1069
WEBS 5-11=-107/638, 5-13=-107/638, 4-14=-1088/0, 6-10=-1088/0
NOTES-(7-8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 10.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T07
Truss Type
Common
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166291
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:03 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-Oxy5?Nq7S4g748_gF2gJzAuWqHItIsgQBa1lsyyZq9o
Scale = 1:49.0
1
2
3
4
7 6 5
6x6
4x6
3x4 3x4 3x8
6x6
6-11-8
6-11-8
13-11-0
6-11-8
6-11-8
6-11-8
13-11-0
6-11-8
14-11-0
1-0-0
1-2-06-4-101-2-09.00 12
Plate Offsets (X,Y)-- [1:Edge,0-1-12], [3:0-3-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.97
0.32
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.04
-0.11
0.01
(loc)
6-7
6-7
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 54 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
1-7,3-5: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)7=542/0-5-8, 5=617/0-3-8
Max Horz 7=-164(LC 4)
Max Uplift7=-19(LC 6), 5=-54(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-550/76, 2-3=-558/80, 1-7=-482/76, 3-5=-556/115
BOT CHORD 5-6=-82/258
WEBS 2-6=0/272
NOTES-(7-8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5.
6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T08
Truss Type
Piggyback Base
Qty
9
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166292
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:04 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-s7VTCjrlDOo_iIZspmBYVORoAhZF1DiZPEnJOPyZq9n
Scale = 1:88.4
1 2
3
4
5 6
7
8
910
18 17 16 15 14 13 12 11192021
3x6
6x8 5x6
3x6
3x4 3x6
3x4
3x6
3x4
3x8
3x4
3x6
5x8
3x4
5x8
3x6
7-5-10
7-5-10
14-8-13
7-3-2
21-2-3
6-5-6
28-5-5
7-3-2
35-11-0
7-5-10
-1-0-0
1-0-0
7-5-10
7-5-10
14-8-13
7-3-2
21-2-3
6-5-6
28-5-5
7-3-2
35-11-0
7-5-10
36-11-0
1-0-0
1-1-010-10-141-1-010-10-148.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge], [3:0-1-12,0-1-8], [5:0-4-8,0-1-12], [6:0-3-0,0-2-3], [8:0-1-12,0-1-8], [9:0-3-0,Edge], [12:0-2-0,0-1-8], [17:0-2-0,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.55
0.63
0.49
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.29
0.08
(loc)
13-16
16-17
11
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 166 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
5-16,5-13,6-13,2-18,9-11: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-4-14 oc purlins, except
end verticals, and 2-0-0 oc purlins (4-5-10 max.): 5-6.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-16, 5-13, 8-13
REACTIONS.(lb/size)18=1678/0-3-8, 11=1669/0-3-8
Max Horz 18=258(LC 5)
Max Uplift18=-85(LC 6), 11=-85(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2213/177, 3-4=-1784/192, 4-5=-1653/236, 5-6=-1366/240, 6-7=-1635/235, 7-8=-1767/192, 8-9=-2199/177,
2-18=-1611/175, 9-11=-1602/175
BOT CHORD 17-18=-267/341, 17-19=-63/1742, 16-19=-63/1742, 15-16=-14/1381, 15-20=-14/1381, 14-20=-14/1381, 13-14=-14/1381,
13-21=-4/1730, 12-21=-4/1730, 11-12=-55/330
WEBS 3-16=-482/159, 5-16=-19/561, 6-13=-3/517, 8-13=-484/159, 2-17=0/1421, 9-12=0/1410
NOTES-(9-10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 11.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T09
Truss Type
Piggyback Base
Qty
7
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166293
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:04 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-s7VTCjrlDOo_iIZspmBYVORlFhZH1CFZPEnJOPyZq9n
Scale = 1:87.3
1 2
3
4
5 6
7
8
9
17 16 15 14 13 12 11 10181920
3x6
6x8 5x6
3x6
3x4 3x6
3x4
3x6
3x4
3x8
3x4
3x8
5x8
3x4
5x6
3x6
7-5-10
7-5-10
14-8-13
7-3-2
21-2-3
6-5-6
28-3-10
7-1-6
35-7-8
7-3-14
-1-0-0
1-0-0
7-5-10
7-5-10
14-8-13
7-3-2
21-2-3
6-5-6
28-3-10
7-1-6
35-7-8
7-3-14
1-1-010-10-141-3-510-10-148.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge], [3:0-1-12,0-1-8], [5:0-4-8,0-1-12], [6:0-3-12,0-2-0], [8:0-1-12,0-1-8], [9:Edge,0-1-12], [11:0-2-8,0-1-8], [16:0-2-4,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.74
0.63
0.52
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.29
0.07
(loc)
12-15
15-16
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 164 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
5-15,5-12,6-12,2-17: 2x4 SPF No.2, 9-10: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-2-8 oc purlins, except
end verticals, and 2-0-0 oc purlins (4-5-15 max.): 5-6.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-15, 5-12, 8-12
REACTIONS.(lb/size)17=1667/0-5-8, 10=1589/Mechanical
Max Horz 17=270(LC 5)
Max Uplift17=-85(LC 6), 10=-48(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2196/176, 3-4=-1766/191, 4-5=-1634/234, 5-6=-1343/238, 6-7=-1608/236, 7-8=-1739/193, 8-9=-2115/173,
2-17=-1600/174, 9-10=-1524/136
BOT CHORD 16-17=-279/330, 16-18=-76/1728, 15-18=-76/1728, 14-15=-28/1366, 14-19=-28/1366, 13-19=-28/1366, 12-13=-28/1366,
12-20=-35/1672, 11-20=-35/1672
WEBS 3-15=-483/159, 5-15=-19/562, 6-12=-6/512, 8-12=-449/159, 2-16=0/1407, 9-11=-16/1506
NOTES-(10-11)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 10.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T10
Truss Type
Piggyback Base
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166294
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:05 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-KK3rQ3sO_hxrJR82NTjn2b_xB5vRmfTjeuWswryZq9m
Scale = 1:87.9
1
2
3
4 5
6
7
89
17 16 15 14 13 12 11 10181920
3x6
5x8 5x6
3x6
3x4 3x6
3x4
3x8
3x4
3x8
3x4
3x6 3x4
5x8 5x6
3x6
7-5-10
7-5-10
14-8-13
7-3-2
21-2-3
6-5-6
28-5-5
7-3-2
35-11-0
7-5-10
7-5-10
7-5-10
14-8-13
7-3-2
21-2-3
6-5-6
28-5-5
7-3-2
35-11-0
7-5-10
36-11-0
1-0-0
1-1-010-10-141-1-010-10-148.00 12
Plate Offsets (X,Y)-- [1:Edge,0-1-12], [2:0-1-12,0-1-8], [4:0-5-8,0-1-12], [5:0-3-0,0-2-3], [7:0-1-12,0-1-8], [8:0-3-0,Edge], [11:0-2-0,0-1-8], [16:0-2-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.66
0.63
0.52
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.14
-0.29
0.08
(loc)
12-15
15-16
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 164 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
4-15,4-12,5-12,8-10,1-17: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-0-1 oc purlins, except
end verticals, and 2-0-0 oc purlins (4-5-8 max.): 4-5.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-15, 4-12, 7-12
REACTIONS.(lb/size)17=1609/Mechanical, 10=1670/0-5-8
Max Horz 17=-267(LC 4)
Max Uplift17=-49(LC 6), 10=-85(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2215/176, 2-3=-1789/193, 3-4=-1655/237, 4-5=-1368/240, 5-6=-1637/236, 6-7=-1769/192, 7-8=-2200/178,
8-10=-1603/175, 1-17=-1541/137
BOT CHORD 16-17=-239/323, 16-18=-63/1752, 15-18=-63/1752, 14-15=-14/1383, 14-19=-14/1383, 13-19=-14/1383, 12-13=-14/1383,
12-20=-5/1731, 11-20=-5/1731, 10-11=-55/330
WEBS 2-15=-492/162, 4-15=-21/568, 5-12=-3/518, 7-12=-484/159, 8-11=0/1411, 1-16=-8/1511
NOTES-(10-11)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 10.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T11
Truss Type
Piggyback Base
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166295
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:05 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-KK3rQ3sO_hxrJR82NTjn2b_v65vRmfRjeuWswryZq9m
Scale = 1:87.0
1
2
3
4 5
6
7
8
16 15 14 13 12 11 10 9171819
3x6
5x8 5x6
3x6
3x4 3x6
3x4
3x8
3x4
3x8
3x4
3x8 3x4
6x6 6x6
3x6
7-5-10
7-5-10
14-8-13
7-3-2
21-2-3
6-5-6
28-5-6
7-3-2
35-11-0
7-5-10
7-5-10
7-5-10
14-8-13
7-3-2
21-2-3
6-5-6
28-5-6
7-3-2
35-11-0
7-5-10
1-1-010-10-141-1-010-10-148.00 12
Plate Offsets (X,Y)-- [1:Edge,0-1-12], [2:0-1-12,0-1-8], [4:0-5-8,0-1-12], [5:0-3-8,0-1-12], [7:0-1-12,0-1-8], [8:Edge,0-1-12], [10:0-2-8,0-1-8], [15:0-2-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.80
0.63
0.52
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.15
-0.30
0.08
(loc)
11-14
14-15
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 163 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
4-14,4-11,5-11: 2x4 SPF No.2, 8-9,1-16: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-11-13 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-5-4 max.): 4-5.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-14, 4-11, 7-11
REACTIONS.(lb/size)16=1610/Mechanical, 9=1600/0-5-8
Max Horz 16=256(LC 5)
Max Uplift16=-49(LC 6), 9=-49(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2217/176, 2-3=-1791/193, 3-4=-1656/237, 4-5=-1370/240, 5-6=-1639/237, 6-7=-1774/193, 7-8=-2202/176,
8-9=-1533/137, 1-16=-1542/137
BOT CHORD 15-16=-248/310, 15-17=-72/1754, 14-17=-72/1754, 13-14=-22/1384, 13-18=-22/1384, 12-18=-22/1384, 11-12=-22/1384,
11-19=-41/1742, 10-19=-41/1742
WEBS 2-14=-493/162, 4-14=-21/568, 5-11=-4/524, 7-11=-495/163, 8-10=-10/1508, 1-15=-10/1519
NOTES-(10-11)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 9.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
T12
Truss Type
Piggyback Base
Qty
10
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166296
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:06 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-oWdEdPs0l?3ixbiFwBE0apW4sVFfV6hstXGQTHyZq9l
Scale = 1:87.0
1
2
3
4 5
6
7
8
16 15 14 13 12 11 10 9171819
3x6
5x8 5x6
3x6
3x4 3x6
3x4
3x8
3x4
3x8
3x4
3x8
6x6
3x4
6x6
3x6
7-5-10
7-5-10
14-8-13
7-3-2
21-2-3
6-5-6
28-5-5
7-3-2
35-11-0
7-5-10
7-5-10
7-5-10
14-8-13
7-3-2
21-2-3
6-5-6
28-5-5
7-3-2
35-11-0
7-5-10
1-1-010-10-141-1-010-10-148.00 12
Plate Offsets (X,Y)-- [1:Edge,0-1-12], [2:0-1-12,0-1-8], [4:0-5-8,0-1-12], [5:0-3-8,0-1-12], [7:0-1-12,0-1-8], [8:Edge,0-1-12], [10:0-2-8,0-1-8], [15:0-2-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.80
0.63
0.52
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.15
-0.30
0.08
(loc)
11-14
14-15
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 163 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x3 SPF No.2 *Except*
4-14,4-11,5-11: 2x4 SPF No.2, 1-16,8-9: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-11-13 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-5-5 max.): 4-5.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 2-14, 4-11, 7-11
REACTIONS.(lb/size)16=1610/Mechanical, 9=1600/Mechanical
Max Horz 16=-256(LC 4)
Max Uplift16=-49(LC 6), 9=-49(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2217/176, 2-3=-1791/193, 3-4=-1656/237, 4-5=-1370/240, 5-6=-1640/237, 6-7=-1774/193, 7-8=-2202/176,
1-16=-1542/137, 8-9=-1533/137
BOT CHORD 15-16=-248/310, 15-17=-72/1754, 14-17=-72/1754, 13-14=-22/1384, 13-18=-22/1384, 12-18=-22/1384, 11-12=-22/1384,
11-19=-41/1742, 10-19=-41/1742
WEBS 2-14=-493/162, 4-14=-21/568, 5-11=-4/524, 7-11=-495/163, 1-15=-10/1519, 8-10=-10/1508
NOTES-(10-11)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 9.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
TG01
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166297
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:07 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-GiBcrlteWJBZZlHRUulF703IMueIEXm?6B?z?kyZq9k
Scale = 1:74.3
Sheet Back
Left Option 7-11-3
1 Ply 7/16OSB8
1 2
3
4
5
6 7
11 10 9 8
34
35 36 37
4x6
4x6 3x8
4x6 4x6
3x4
4x6 4x6
3x4
2x4
2x4
2x4
2x4
2x4
2x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
7-11-3
7-11-3
9-11-8
2-0-5
19-11-0
9-11-8
-1-0-0
1-0-0
5-1-8
5-1-8
9-11-8
4-10-0
14-8-7
4-8-15
14-9-8
0-1-1
19-11-0
5-1-8
20-11-0
1-0-0
1-2-08-7-101-2-09.00 12
Plate Offsets (X,Y)-- [14:0-1-9,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.62
0.41
0.66
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.16
0.02
(loc)
9-11
9-11
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 261 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF-S Stud
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)11=851/0-3-8, 8=853/0-3-8
Max Horz 11=203(LC 4)
Max Uplift11=-122(LC 5), 8=-82(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-34=-316/136, 3-4=-712/138, 4-5=-712/135, 5-6=-318/110, 2-11=-350/167, 6-8=-352/132
BOT CHORD 11-35=-73/630, 10-35=-73/630, 10-36=-73/630, 36-37=-73/630, 9-37=-73/630, 8-9=-10/630
WEBS 4-9=-74/525, 3-11=-609/29, 5-8=-607/49
NOTES-(11-12)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever
left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable studs spaced at 1-4-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb)
11=122.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 56 lb down and 84 lb up at 1-8-0 on
top chord, and 7 lb down and 16 lb up at 1-8-12, 7 lb down and 16 lb up at 3-8-12, and 7 lb down and 16 lb up at 5-8-12, and 7 lb down
and 16 lb up at 7-8-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-4=-60, 4-6=-60, 6-7=-60, 8-11=-20
Concentrated Loads (lb)
Vert: 10=1(B) 35=1(B) 36=1(B) 37=1(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
TG02
Truss Type
Common Girder
Qty
1
Ply
3
26 Bear creek estates
Job Reference (optional)
I31166298
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:07 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-GiBcrlteWJBZZlHRUulF703F3ubEEVK?6B?z?kyZq9k
Scale = 1:85.0
1
2
3
4
5
11 10 9 8 7 61213141516171819202122
12x12
4x8
12x12
5x10 MT18HS
10x10
4x6
8x8
4x6
8x8
6-5-8
6-5-8
12-7-8
6-2-0
18-9-8
6-2-0
25-3-0
6-5-8
6-5-8
6-5-8
12-7-8
6-2-0
18-9-8
6-2-0
25-3-0
6-5-8
1-2-010-7-101-2-09.00 12
Plate Offsets (X,Y)-- [1:Edge,0-10-4], [2:0-1-12,0-2-0], [4:0-1-12,0-2-0], [5:Edge,0-10-4], [7:0-3-8,0-4-8], [10:0-3-8,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.83
0.61
0.82
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.29
0.04
(loc)
7-8
7-8
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT18HS
Weight: 443 lb FT = 20%
GRIP
169/123
244/190
LUMBER-
TOP CHORD 2x4 SPF 2100F 1.8E
BOT CHORD 2x6 SP 2400F 2.0E
WEBS 2x4 SPF-S Stud *Except*
3-8,1-10,5-7: 2x4 SPF No.2, 1-11,5-6: 2x4 SPF 2100F 1.8E
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)11=10719/0-3-8, 6=10352/0-3-8
Max Horz 11=-247(LC 3)
Max Uplift11=-413(LC 5), 6=-398(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-12234/499, 2-3=-8752/456, 3-4=-8752/456, 4-5=-12181/497, 1-11=-8540/363,
5-6=-8511/362
BOT CHORD 11-12=-300/1918, 12-13=-300/1918, 13-14=-300/1918, 10-14=-300/1918,
10-15=-389/9685, 9-15=-389/9685, 9-16=-389/9685, 8-16=-389/9685, 8-17=-318/9643,
17-18=-318/9643, 18-19=-318/9643, 7-19=-318/9643, 7-20=-104/1853, 20-21=-104/1853,
21-22=-104/1853, 6-22=-104/1853
WEBS 3-8=-434/9985, 4-8=-3705/281, 4-7=-113/4216, 2-8=-3762/283, 2-10=-115/4286,
1-10=-236/7839, 5-7=-240/7863
NOTES-(12-13)
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever
left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) All plates are MT20 plates unless otherwise indicated.
6) The Fabrication Tolerance at joint 1 = 0%, joint 5 = 0%
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=413,
6=398.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1589 lb down and 61 lb up at
1-4-12, 1590 lb down and 61 lb up at 3-4-12, 1590 lb down and 61 lb up at 5-4-12, 1590 lb down and 61 lb up at 7-4-12, 1590 lb down
and 61 lb up at 9-4-12, 1590 lb down and 61 lb up at 11-4-12, 1590 lb down and 61 lb up at 13-4-12, 1590 lb down and 61 lb up at
15-4-12, 1590 lb down and 61 lb up at 17-4-12, 1590 lb down and 61 lb up at 19-4-12, and 1590 lb down and 61 lb up at 21-4-12, and
1590 lb down and 61 lb up at 23-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of
others.
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
TG02
Truss Type
Common Girder
Qty
1
Ply
3
26 Bear creek estates
Job Reference (optional)
I31166298
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:07 2017 Page 2 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-GiBcrlteWJBZZlHRUulF703F3ubEEVK?6B?z?kyZq9k
12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-5=-60, 6-11=-20
Concentrated Loads (lb)
Vert: 9=-1590(B) 12=-1589(B) 13=-1590(B) 14=-1590(B) 15=-1590(B) 16=-1590(B) 17=-1590(B) 18=-1590(B) 19=-1590(B) 20=-1590(B) 21=-1590(B) 22=-1590(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
26_BEAR_CREEK_ESTATES
Truss
TG03
Truss Type
Common Girder
Qty
1
Ply
2
26 Bear creek estates
Job Reference (optional)
I31166299
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:08 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-kvl_25uGGcJPBvsd2cGUgEcUqI0Fz?M9KrlWXAyZq9j
Scale = 1:47.0
1
2
3
4
5
10 9 8 7 61112131415
12x12
4x6
12x12
8x8
3x6
6x6
3x6
6x6
3-5-8
3-5-8
6-7-8
3-2-0
9-9-8
3-2-0
13-3-0
3-5-8
3-5-8
3-5-8
6-7-8
3-2-0
9-9-8
3-2-0
13-3-0
3-5-8
1-2-06-1-101-2-09.00 12
Plate Offsets (X,Y)-- [1:Edge,0-10-4], [2:0-2-8,0-1-8], [4:0-2-8,0-1-8], [5:Edge,0-10-4], [7:0-3-0,0-3-8], [9:0-3-0,0-3-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.57
0.30
0.57
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.04
-0.10
0.01
(loc)
7-8
7-8
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 158 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SP 2400F 2.0E
WEBS 2x4 SPF No.2 *Except*
4-8,4-7,2-8,2-9: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-3-9 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)10=6214/0-5-8, 6=5816/0-3-8
Max Horz 10=-142(LC 3)
Max Uplift10=-230(LC 5), 6=-218(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-5156/218, 2-3=-4131/226, 3-4=-4131/226, 4-5=-5396/227, 1-10=-4128/173, 5-6=-4290/179
BOT CHORD 10-11=-145/419, 9-11=-145/419, 9-12=-171/4062, 8-12=-171/4062, 8-13=-133/4253, 7-13=-133/4253, 7-14=-26/544,
14-15=-26/544, 6-15=-26/544
WEBS 3-8=-212/4675, 4-8=-1431/128, 4-7=-51/1662, 2-8=-1153/117, 2-9=-38/1313, 1-9=-114/3765, 5-7=-117/3833
NOTES-(10-11)
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever
left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=230,
6=218.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1576 lb down and 55 lb up at
0-1-12, 1569 lb down and 60 lb up at 2-4-12, 1569 lb down and 60 lb up at 4-4-12, 1569 lb down and 60 lb up at 6-4-12, 1569 lb down
and 60 lb up at 8-4-12, and 1569 lb down and 60 lb up at 10-4-12, and 1572 lb down and 58 lb up at 12-4-12 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
TG03
Truss Type
Common Girder
Qty
1
Ply
2
26 Bear creek estates
Job Reference (optional)
I31166299
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:08 2017 Page 2 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-kvl_25uGGcJPBvsd2cGUgEcUqI0Fz?M9KrlWXAyZq9j
LOAD CASE(S) Standard
Uniform Loads (plf)
Vert: 1-3=-60, 3-5=-60, 6-10=-20
Concentrated Loads (lb)
Vert: 10=-1576(F) 8=-1569(F) 11=-1569(F) 12=-1569(F) 13=-1569(F) 14=-1569(F) 15=-1572(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
26_BEAR_CREEK_ESTATES
Truss
TG04
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166300
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:09 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-C5JMFQvu1wRGo3RqcJnjCR8ciiIRiNAIZVU43cyZq9i
Scale = 1:79.7
Sheet Back
Left Option 6-10-0
1 Ply 7/16OSB8
1 2
3
4
5
6 7
11 10 9 8
35
36 37 38
4x6
5x6 3x8
4x6 8x8
3x6
4x6 4x6
3x6
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4 2x4
2x4 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
6-10-0
6-10-0
10-11-12
4-1-12
21-11-8
10-11-12
-1-0-0
1-0-0
5-7-10
5-7-10
10-11-12
5-4-2
15-2-1
4-2-5
16-3-14
1-1-13
21-11-8
5-7-10
22-11-8
1-0-0
1-2-09-4-131-2-09.00 12
Plate Offsets (X,Y)-- [3:0-4-0,0-2-12], [10:0-2-12,0-2-8], [11:0-2-12,0-2-0], [13:0-1-9,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.76
0.50
0.86
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.09
-0.23
0.02
(loc)
9-11
9-11
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 277 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF-S Stud *Except*
4-9: 2x4 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)11=929/0-5-8, 8=934/0-3-8
Max Horz 11=-221(LC 3)
Max Uplift11=-126(LC 5), 8=-83(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-35=-373/149, 3-35=-269/172, 3-4=-795/144, 4-5=-795/142, 5-6=-379/122,
2-11=-394/180, 6-8=-397/143
BOT CHORD 11-36=-75/711, 36-37=-75/711, 10-37=-75/711, 10-38=-75/711, 9-38=-75/711,
8-9=-10/711
WEBS 4-9=-71/586, 3-11=-660/51, 5-8=-655/51
NOTES-(11-12)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever
left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable studs spaced at 1-4-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb)
11=126.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 75 lb down and 74 lb up at 1-8-0 on
top chord, and 7 lb down and 16 lb up at 1-8-0, 7 lb down and 16 lb up at 3-8-12, and 7 lb down and 16 lb up at 5-8-12, and 7 lb down
and 16 lb up at 7-8-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-4=-60, 4-6=-60, 6-7=-60, 8-11=-20
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
TG04
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166300
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:09 2017 Page 2 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-C5JMFQvu1wRGo3RqcJnjCR8ciiIRiNAIZVU43cyZq9i
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: 10=1(B) 36=5(B) 37=1(B) 38=1(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
26_BEAR_CREEK_ESTATES
Truss
TG05
Truss Type
Common Girder
Qty
1
Ply
3
26 Bear creek estates
Job Reference (optional)
I31166301
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:10 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-hHtkTmwWoEZ7QD0090Iylfhks6e5Rt1So9Edc2yZq9h
Scale = 1:71.4
1
2
3
4
5
11 10 9 8 7 61213141516171819
12x12
4x6
12x12
5x8 8x8
3x8
6x8
3x8
6x8
5-7-10
5-7-10
10-11-12
5-4-2
16-3-14
5-4-2
21-11-8
5-7-10
5-7-10
5-7-10
10-11-12
5-4-2
16-3-14
5-4-2
21-11-8
5-7-10
1-2-09-4-131-2-09.00 12
Plate Offsets (X,Y)-- [1:Edge,0-10-4], [2:0-3-8,0-1-8], [4:0-3-8,0-1-8], [5:Edge,0-10-4], [7:0-3-8,0-4-0], [10:0-3-8,0-4-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.92
0.47
0.69
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.10
-0.23
0.03
(loc)
8-10
8-10
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 386 lb FT = 20%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SP 2400F 2.0E
WEBS 2x4 SPF No.2 *Except*
4-8,4-7,2-8,2-10: 2x4 SPF-S Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)11=8669/0-5-8, 6=8862/0-3-8
Max Horz 11=218(LC 12)
Max Uplift11=-335(LC 5), 6=-342(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-10196/421, 2-3=-7404/392, 3-4=-7404/392, 4-5=-10197/421, 1-11=-7311/312,
5-6=-7301/311
BOT CHORD 11-12=-251/1239, 12-13=-251/1239, 10-13=-251/1239, 10-14=-325/8069, 9-14=-325/8069,
9-15=-325/8069, 8-15=-325/8069, 8-16=-266/8070, 16-17=-266/8070, 7-17=-266/8070,
7-18=-76/1310, 18-19=-76/1310, 6-19=-76/1310
WEBS 3-8=-372/8436, 4-8=-3056/238, 4-7=-96/3476, 2-8=-3055/238, 2-10=-95/3475,
1-10=-211/6914, 5-7=-210/6843
NOTES-(11-12)
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever
left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) The Fabrication Tolerance at joint 1 = 16%, joint 5 = 16%
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=335,
6=342.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1580 lb down and 61 lb up at
2-1-4, 1580 lb down and 61 lb up at 4-1-4, 1580 lb down and 61 lb up at 6-1-4, 1580 lb down and 61 lb up at 8-1-4, 1580 lb down and
61 lb up at 10-1-4, 1580 lb down and 61 lb up at 12-1-4, 1580 lb down and 61 lb up at 14-1-4, 1580 lb down and 61 lb up at 16-1-4,
and 1580 lb down and 61 lb up at 18-1-4, and 1580 lb down and 61 lb up at 20-1-4 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
LOAD CASE(S) StandardContinued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
TG05
Truss Type
Common Girder
Qty
1
Ply
3
26 Bear creek estates
Job Reference (optional)
I31166301
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:10 2017 Page 2 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-hHtkTmwWoEZ7QD0090Iylfhks6e5Rt1So9Edc2yZq9h
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-5=-60, 6-11=-20
Concentrated Loads (lb)
Vert: 9=-1580(F) 7=-1580(F) 12=-1580(F) 13=-1580(F) 14=-1580(F) 15=-1580(F) 16=-1580(F) 17=-1580(F) 18=-1580(F) 19=-1580(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
26_BEAR_CREEK_ESTATES
Truss
V01
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166302
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:10 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-hHtkTmwWoEZ7QD0090Iylfhws6jyR_4So9Edc2yZq9h
Scale = 1:67.6
1
2
3
4
5
6
7
13 12 11 10 9 83x4
4x6
3x4
3x6 2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
2x4
22-2-15
22-2-15
11-1-7
11-1-7
22-2-15
11-1-7
0-0-48-4-20-0-49.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.16
0.16
0.24
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
7
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 73 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 22-2-15.
(lb) - Max Horz 1=-186(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 1, 13, 8 except 11=-108(LC 6), 9=-108(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=413(LC 1), 11=424(LC 10), 13=282(LC 1),
9=424(LC 11), 8=282(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-11=-265/158, 5-9=-265/158
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 13, 8 except (jt=lb)
11=108, 9=108.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V02
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166303
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:11 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-9TR6g6w9ZXh_2MbCjkpBHsD2vW0OASjb1pzB8VyZq9g
Scale = 1:56.9
1
2
3
4
5
9 8 7 63x4
4x6
3x4
2x4
2x4
2x4
2x4
2x4
2x4
18-8-4
18-8-4
9-4-2
9-4-2
18-8-4
9-4-2
0-0-47-0-20-0-49.00 12
Plate Offsets (X,Y)-- [1:0-1-11,0-1-8], [5:0-0-5,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.33
0.34
0.15
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 52 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x3 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 18-8-4.
(lb) - Max Horz 1=-156(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-136(LC 6), 6=-136(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=379(LC 1), 9=512(LC 10), 6=512(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-326/184, 4-6=-326/184
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=136
, 6=136.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V03
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166304
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:11 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-9TR6g6w9ZXh_2MbCjkpBHsD26W4mATAb1pzB8VyZq9g
Scale = 1:44.5
1
2
3
4
5
8 7 69103x4
3x6
3x4
2x4 2x4
2x4
2x4
2x4
15-1-10
15-1-10
7-6-13
7-6-13
15-1-10
7-6-13
0-0-45-8-20-0-49.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.38
0.12
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 40 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x3 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 15-1-10.
(lb) - Max Horz 1=-125(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-109(LC 6), 6=-109(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=391(LC 1), 8=358(LC 10), 6=358(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=109
, 6=109.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V04
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166305
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:11 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-9TR6g6w9ZXh_2MbCjkpBHsD01W0VATWb1pzB8VyZq9g
Scale = 1:34.4
1
2
3
45x8
5x6
5x8
2x4
11-6-15
11-6-15
5-9-7
5-9-7
11-6-15
5-9-7
0-0-44-4-20-0-49.00 12
Plate Offsets (X,Y)-- [1:0-1-4,Edge], [2:0-4-0,0-2-0], [3:0-2-2,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.45
0.33
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 27 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x3 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=208/11-6-15, 3=208/11-6-15, 4=442/11-6-15
Max Horz 1=94(LC 5)
Max Uplift1=-16(LC 6), 3=-22(LC 7), 4=-1(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V05
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166306
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:12 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-dg_VuSxnKrprfWAPHRLQq4mBgvNXvxflFTjkgxyZq9f
Scale = 1:25.7
1
2
3
42x4
3x4
2x4 2x4
8-0-4
8-0-4
4-0-2
4-0-2
8-0-4
4-0-2
0-0-43-0-20-0-49.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.46
0.28
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x3 SPF No.2
BOT CHORD 2x3 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=163/8-0-4, 3=163/8-0-4, 4=265/8-0-4
Max Horz 1=64(LC 5)
Max Uplift1=-24(LC 6), 3=-29(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V06
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166307
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:12 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-dg_VuSxnKrprfWAPHRLQq4mHtvQkvx3lFTjkgxyZq9f
Scale = 1:13.3
1
2
3
4
2x4
3x4
2x4 2x4
4-5-10
4-5-10
2-2-13
2-2-13
4-5-10
2-2-13
0-0-41-8-20-0-49.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.12
0.08
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 9 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x3 SPF No.2
BOT CHORD 2x3 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-5-10 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=85/4-5-10, 3=85/4-5-10, 4=138/4-5-10
Max Horz 1=-33(LC 4)
Max Uplift1=-12(LC 6), 3=-15(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V07
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166308
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:12 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-dg_VuSxnKrprfWAPHRLQq4mEOvMYvxMlFTjkgxyZq9f
Scale = 1:29.4
1
2
3
44x6
4x6
4x6 2x4
9-3-6
9-3-6
4-7-11
4-7-11
9-3-6
4-7-11
0-0-43-5-120-0-49.00 12
Plate Offsets (X,Y)-- [1:0-1-8,Edge], [2:0-4-0,0-2-0], [3:0-1-15,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.28
0.34
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 19 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x3 SPF No.2
BOT CHORD 2x3 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=171/9-3-6, 3=171/9-3-6, 4=351/9-3-6
Max Horz 1=-75(LC 4)
Max Uplift1=-16(LC 6), 3=-22(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V08
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166309
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:13 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-5sYt5oyP59xiHglbr9sfNHJQ9Jl3eOCuU7THCNyZq9e
Scale = 1:19.1
1
2
3
4
2x4
3x4
2x4 2x4
5-8-11
5-8-11
2-10-6
2-10-6
5-8-11
2-10-6
0-0-42-1-120-0-49.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.22
0.13
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x3 SPF No.2
BOT CHORD 2x3 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-8-11 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=113/5-8-11, 3=113/5-8-11, 4=183/5-8-11
Max Horz 1=-44(LC 4)
Max Uplift1=-16(LC 6), 3=-20(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V09
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166310
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:13 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-5sYt5oyP59xiHglbr9sfNHJPYJiyeMEuU7THCNyZq9e
Scale = 1:56.4
1
2
3
4
5
9 8 7 63x4
4x6
3x4
2x4
2x4
2x4
2x4
2x4
2x4
18-6-2
18-6-2
9-3-1
9-3-1
18-6-2
9-3-1
0-0-46-11-50-0-49.00 12
Plate Offsets (X,Y)-- [1:0-1-11,0-1-8], [5:0-0-5,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.32
0.33
0.15
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 51 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x3 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 18-6-2.
(lb) - Max Horz 1=-155(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-134(LC 6), 6=-134(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=382(LC 1), 9=506(LC 10), 6=506(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-322/182, 4-6=-322/182
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=134
, 6=134.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V10
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166311
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:14 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-Z26FJ8z1sS3ZvqKnOsNuvVrZOj6jNqy1jnCrlqyZq9d
Scale = 1:44.0
1
2
3
4
5
8 7 69103x4
3x6
3x4
2x4 2x4
2x4
2x4
2x4
14-11-7
14-11-7
7-5-11
7-5-11
14-11-7
7-5-11
0-0-45-7-50-0-49.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.38
0.11
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 39 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x3 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 14-11-7.
(lb) - Max Horz 1=124(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-108(LC 6), 6=-108(LC 7)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=334(LC 10), 6=334(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=108
, 6=108.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V11
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166312
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:14 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-Z26FJ8z1sS3ZvqKnOsNuvVrYUj2NNqK1jnCrlqyZq9d
Scale = 1:33.9
1
2
3
45x8
5x6
5x8
2x4
11-4-12
11-4-12
5-8-6
5-8-6
11-4-12
5-8-6
0-0-44-3-50-0-49.00 12
Plate Offsets (X,Y)-- [1:0-1-4,Edge], [2:0-4-0,0-2-0], [3:0-2-2,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.43
0.32
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 27 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x3 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=205/11-4-12, 3=205/11-4-12, 4=435/11-4-12
Max Horz 1=-93(LC 4)
Max Uplift1=-16(LC 6), 3=-22(LC 7), 4=-1(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C
Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V12
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166313
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:14 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-Z26FJ8z1sS3ZvqKnOsNuvVrYVj3CNrA1jnCrlqyZq9d
Scale = 1:25.2
1
2
3
42x4
3x4
2x4 2x4
7-10-2
7-10-2
3-11-1
3-11-1
7-10-2
3-11-1
0-0-42-11-50-0-49.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.43
0.27
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x3 SPF No.2
BOT CHORD 2x3 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=159/7-10-2, 3=159/7-10-2, 4=259/7-10-2
Max Horz 1=-63(LC 4)
Max Uplift1=-23(LC 6), 3=-28(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
Job
26_BEAR_CREEK_ESTATES
Truss
V13
Truss Type
GABLE
Qty
1
Ply
1
26 Bear creek estates
Job Reference (optional)
I31166314
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Sep 26 07:46:15 2017 Page 1 PROBUILD, MOORESVILLE, IN 46158
ID:Wj3stNM1qy4wgPMcpNbs9dzZgK_-1FgdWUzfdmBQW_uzyau7SiOoH7SY6IpBxRyOHGyZq9c
Scale = 1:12.9
1
2
3
4
2x4
3x4
2x4 2x4
4-3-7
4-3-7
2-1-11
2-1-11
4-3-7
2-1-11
0-0-41-7-50-0-49.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI.
TC
BC
WB
(Matrix)
0.11
0.07
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 8 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x3 SPF No.2
BOT CHORD 2x3 SPF No.2
OTHERS 2x3 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-3-7 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=81/4-3-7, 3=81/4-3-7, 4=131/4-3-7
Max Horz 1=-32(LC 4)
Max Uplift1=-12(LC 6), 3=-14(LC 7)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(8-9)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1
9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using
proprietary methods (e.g. Stabilizer, etc.).
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
September 26,2017
edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.