HomeMy WebLinkAboutA000.75:12 5:12 5:12 5:12 5:12 5:12 5:12 5:12 5:12 5:12 5:125:12 "A" 2486ROOF AREA: SQ. FT. MIN. 99 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D" \A1;1'-0"\PTYP. PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION \A1;2'-10{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S7#8;}" \A1;5'-4" 9:12 9:12 "C" 198ROOF AREA: SQ. FT. \A1;4'-0" \A1;22'-0" POT VENTS \A1;10'-0"ELEVATION CR2GATTIC VENT SCHEDULEVENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATIONROOF AREA "C"SQ FTG198AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.260.330.4243.2610AT EAVE0.400.330.5656.7408.00TOTAL (MIN)0.660.660.98100.003 HIGH -RIDGE VENT0.260.330.5047.37004.00AT EAVE0.400.330.5652.6308.00TOTAL (MIN)0.660.661.06100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEROOF AREA "A"SQ FTG2486AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY3.314.143.3943.6580AT EAVE4.974.144.3856.35063.00TOTAL (MIN)8.298.297.76100.003HIGH -RIDGE VENT3.314.144.0047.760032.00AT EAVE4.974.144.3852.24063.00TOTAL (MIN)8.298.298.38100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE"B" 572ROOF AREA: SQ. FT. GUTTER AND DOWNSPOUTS 4:12 4:12 4:12 ROOF AREA "B"SQ FTG572AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.760.950.8543.2620AT EAVE1.140.951.1156.74016.00TOTAL (MIN)1.911.911.96100.003HIGH -RIDGE VENT0.760.950.00#####000.00AT EAVE1.140.950.00#####00.00TOTAL (MIN)1.911.910.00######ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEA4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPESingle Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Rockwall 2054.300Home for * Market Home *, 5782-12500#23330 Spruce Wood Court, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) 01/11/19 Mike Sheeks