I35640280.125_Woods_at_Shelborne
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). December 20,2018 Liu, Xuegang Pages or sheets covered by this seal: I35640280 thru I35640333 My license renewal date for the state of Indiana is July 31, 2020. 125_Woods_at_Shelborne Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: 125 Woods at Shelborne 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss GE01 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640280 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:08 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-kiFkJSkBnivf4cFcUSgoHBu732ZnmhTeVv3y_Py7Luj Scale = 1:37.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 3x8 4x6 3x83x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 20-5-0 20-5-0 -1-0-0 1-0-0 10-2-8 10-2-8 20-5-0 10-2-8 21-5-0 1-0-0 0-10-05-1-10-10-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.03 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 17 17 18 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 202 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 20-5-0. (lb) - Max Horz 33=52(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 33, 18, 26, 27, 28, 29, 31, 32, 24, 23, 22, 21, 20, 19 Max Grav All reactions 250 lb or less at joint(s) 33, 18, 25, 26, 27, 28, 29, 31, 32, 24, 23, 22, 21, 20, 19 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 18, 26, 27, 28, 29, 31, 32, 24, 23, 22, 21, 20, 19. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss GE02 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640281 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:09 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-Cup6WolpY01Wimqo29B1qPRIpSvFV8?okZoVWry7Lui Scale: 1/2"=1' Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x8 4x6 3x82x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-1-0 13-1-0 -1-0-0 1-0-0 6-6-8 6-6-8 13-1-0 6-6-8 14-1-0 1-0-0 0-10-03-6-110-10-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.02 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 105 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 13-1-0. (lb) - Max Horz 24=-38(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss GE03 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640282 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:10 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-g4NUk8mRJJ9NJwO?btiGNczSKsFAEaCxyDY32Hy7Luh Scale = 1:49.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 3x8 3x6 4x6 3x6 3x83x6 28-11-0 28-11-0 -1-0-0 1-0-0 14-5-8 14-5-8 28-11-0 14-5-8 29-11-0 1-0-0 0-10-06-10-50-10-05.00 12 Plate Offsets (X,Y)-- [41:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.11 0.04 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 27 27 28 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 352 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 28-11-0. (lb) - Max Horz 51=68(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 51, 28, 40, 42, 43, 44, 45, 46, 47, 48, 49, 50, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29 Max Grav All reactions 250 lb or less at joint(s) 51, 28, 39, 40, 42, 43, 44, 45, 46, 47, 48, 49, 50, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 51, 28, 40, 42, 43, 44, 45, 46, 47, 48, 49, 50, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss GE04 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640283 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:12 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-dTVF9pnhqwP5ZDYNjHkkS13o3fwxiVjEQX1A7Ay7Luf Scale = 1:25.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x8 4x6 3x82x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-11-0 13-11-0 -1-0-0 1-0-0 6-11-8 6-11-8 13-11-0 6-11-8 14-11-0 1-0-0 0-10-03-8-130-10-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.02 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 114 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 13-11-0. (lb) - Max Horz 24=-39(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss GE05 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640284 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:13 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-5f3dM9oJbEXyAN7aH?Fz_Fbzo3G1RyyOeBmjfcy7Lue Scale = 1:26.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x8 4x6 3x82x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-9-0 14-9-0 -1-0-0 1-0-0 7-4-8 7-4-8 14-9-0 7-4-8 15-9-0 1-0-0 0-10-03-10-140-10-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.03 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 124 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 14-9-0. (lb) - Max Horz 24=41(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss GE06 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640285 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:15 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-12ANnrqa7rngQhHyOQIS4ghJvty1vr5g6VFqjVy7Luc Scale = 1:70.4 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 4645 44 43 42 41 40 39 38 37 36 35 3x8 5x6 3x83x6 5x6 5x6 3x6 41-11-0 41-11-0 20-11-8 20-11-8 41-11-0 20-11-8 42-11-0 1-0-0 0-10-09-6-130-10-05.00 12 Plate Offsets (X,Y)-- [1:0-0-8,0-1-4], [6:0-3-0,0-3-0], [28:0-3-0,0-3-0], [69:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.12 0.06 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.01 (loc) 34 34 35 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 656 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 33-35: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 17-52, 16-53, 15-54, 18-51, 19-50 REACTIONS. All bearings 41-11-0. (lb) - Max Horz 69=-102(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 69, 54, 55, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 50, 49, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36 except 68=-101(LC 6) Max Grav All reactions 250 lb or less at joint(s) 69, 35, 52, 53, 54, 55, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 51, 50, 49, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 69, 54, 55, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 50, 49, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36 except (jt=lb) 68=101. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss GE07 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640286 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:21 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-sCYe1uuKjhYp8ck6lgPsJxxAgHpLJKAZURi8x9y7LuW Scale = 1:71.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 1089 90 3x6 5x6 3x6 5x12 3x8 4x6 4x6 3x6 4x6 4x6 3x6 8x8 8x85x12 10-7-0 10-7-0 18-3-8 7-8-8 20-11-8 2-8-0 31-4-0 10-4-8 41-11-0 10-7-0 7-1-8 7-1-8 14-0-8 6-11-0 20-11-8 6-11-0 27-10-8 6-11-0 34-9-8 6-11-0 41-11-0 7-1-8 0-10-09-6-130-10-05.00 12 Plate Offsets (X,Y)-- [1:0-1-12,0-0-12], [1:Edge,0-2-12], [9:0-1-12,0-0-12], [10:Edge,0-2-12], [12:0-0-0,0-1-12], [16:0-0-0,0-1-12], [17:0-1-4,0-0-0], [29:0-1-10,0-0-0], [32:0-1-10 ,0-0-0], [34:0-1-10,0-0-0], [36:0-1-10,0-0-0], [45:0-1-10,0-0-0], [47:0-1-10,0-0-0], [55:0-1-10,0-0-0], [58:0-1-10,0-0-0], [61:0-1-10,0-0-0], [63:0-1-4,0-0-0], [64:0-1-10,0-0-0], [77:0-1-10,0-0-0], [80:0-1-10,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.81 0.83 0.97 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.42 -0.79 0.06 (loc) 11-13 11-13 10 l/defl >667 >359 n/a L/d 240 180 n/a PLATES MT20 Weight: 696 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 12-16: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-28,9-10: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 6-13, 4-21, 8-10 REACTIONS. All bearings 18-3-8 except (jt=length) 10=Mechanical, 14=0-3-8, 14=0-3-8. (lb) - Max Horz 28=-81(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 10, 15, 14 except 21=-217(LC 6), 28=-139(LC 11) Max Grav All reactions 250 lb or less at joint(s) 28, 15, 17, 18, 19, 20, 22, 23, 24, 25, 26, 27, 14, 14 except 21=1925(LC 1), 10=1227(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-42/740, 4-5=-971/231, 5-6=-971/231, 6-8=-1977/276, 8-9=-549/96, 9-10=-378/99 BOT CHORD 27-28=-386/82, 26-27=-386/82, 25-26=-386/82, 24-25=-386/82, 23-24=-386/82, 22-23=-386/82, 21-22=-386/82, 11-13=-83/1459, 10-11=-213/1963 WEBS 5-13=-28/324, 6-13=-889/202, 6-11=0/620, 8-11=-300/187, 4-13=0/787, 4-21=-1777/276, 2-21=-481/215, 2-28=-86/409, 8-10=-1707/223 NOTES- (10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 15, 14 except (jt=lb) 21=217, 28=139. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss GE08 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640287 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:23 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-oafPSawbFJoXNvuVs5RKOM0hA5hKnT_sylBF?1y7LuU Scale = 1:42.4 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 3x8 4x6 3x8 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 23-11-0 23-11-0 -1-0-0 1-0-0 11-11-8 11-11-8 23-11-0 11-11-8 0-10-05-9-130-10-05.00 12 Plate Offsets (X,Y)-- [33:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.10 0.03 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 1 1 21 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 258 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 23-11-0. (lb) - Max Horz 39=67(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 39, 31, 32, 33, 34, 35, 36, 37, 38, 29, 28, 27, 26, 25, 24, 23, 22 Max Grav All reactions 250 lb or less at joint(s) 39, 21, 30, 31, 32, 33, 34, 35, 36, 37, 38, 29, 28, 27, 26, 25, 24, 23, 22 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 39, 31, 32, 33, 34, 35, 36, 37, 38, 29, 28, 27, 26, 25, 24, 23, 22. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss J01 Truss Type Jack-Open Qty 3 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640288 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:24 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-GnDngwxD0cwO?3ThQpyZxZZsrV02Ww4?APxoYUy7LuT Scale = 1:11.3 1 2 5 3 4 3x6 2-9-8 2-9-8 -1-0-0 1-0-0 2-9-8 2-9-8 0-9-01-8-31-4-01-8-34.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.11 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=187/0-3-0, 3=63/Mechanical, 4=25/Mechanical Max Horz 5=51(LC 6) Max Uplift 5=-42(LC 4), 3=-23(LC 6) Max Grav 5=187(LC 1), 3=63(LC 1), 4=48(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss J02 Truss Type Jack-Open Qty 2 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640289 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:25 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-kzn9tGyrmw2FdD2t_WToUn50cvMPFNK9P3gM4wy7LuS Scale = 1:9.8 1 2 5 3 4 3x6 2-8-8 2-8-8 -1-5-0 1-5-0 2-8-8 2-8-8 0-9-01-4-112.83 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.17 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=223/0-3-14, 3=52/Mechanical, 4=19/Mechanical Max Horz 5=42(LC 6) Max Uplift 5=-65(LC 4), 3=-15(LC 6) Max Grav 5=223(LC 1), 3=52(LC 1), 4=44(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss J03 Truss Type Jack-Open Qty 2 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640290 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:26 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-C9LX5cyTXEA6ENd4XE_10_eBXIi1_qaIejQvcMy7LuR Scale = 1:9.9 1 2 5 3 4 3x6 1-11-8 1-11-8 -1-0-0 1-0-0 1-11-8 1-11-8 0-9-01-4-131-0-101-4-134.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=163/0-3-0, 3=36/Mechanical, 4=14/Mechanical Max Horz 5=43(LC 6) Max Uplift 5=-43(LC 4), 3=-14(LC 6) Max Grav 5=163(LC 1), 3=36(LC 1), 4=32(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss J04 Truss Type Jack-Open Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640291 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:27 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-gMvwIyz5IXIzsXCG5xWGZCBMti1ajHqRsN9S9oy7LuQ Scale = 1:11.6 1 2 5 3 4 3x6 3-0-0 3-0-0 -1-0-0 1-0-0 3-0-0 3-0-0 0-9-01-9-01-4-131-9-04.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.12 0.07 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=195/0-3-8, 3=70/Mechanical, 4=28/Mechanical Max Horz 5=53(LC 6) Max Uplift 5=-42(LC 4), 3=-26(LC 6) Max Grav 5=195(LC 1), 3=70(LC 1), 4=52(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss M03 Truss Type Monopitch Qty 5 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640292 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:28 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-9YTIVH_j3rQqUhmSff1V5PjRD6JsSkZb51v0hFy7LuP Scale = 1:17.6 1 2 3 5 4 2x4 3x6 2x4 5-11-8 5-11-8 -1-0-0 1-0-0 5-11-8 5-11-8 0-9-02-8-130-3-84.00 12 Plate Offsets (X,Y)-- [4:0-1-14,0-0-9] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.47 0.33 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.10 -0.15 0.00 (loc) 4-5 4-5 l/defl >676 >470 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=304/0-3-8, 4=221/0-1-8 Max Horz 5=83(LC 6) Max Uplift 5=-91(LC 4), 4=-80(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-254/130 NOTES- (8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss M04 Truss Type Monopitch Qty 10 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640293 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:29 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-dk0gjd?Mq9Yh5qLeDMYkedGakWfTB7fkKheZDhy7LuO Scale = 1:24.8 1 2 3 4 6 5 2x4 3x8 2x4 6x6 -1-0-0 1-0-0 4-11-12 4-11-12 9-11-8 4-11-12 0-9-04-0-133-9-50-3-84-0-134.00 12 Plate Offsets (X,Y)-- [2:0-0-15,0-2-12], [4:0-2-0,0-0-8], [5:Edge,0-1-12], [6:0-0-0,0-2-12], [6:0-2-7,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.61 0.37 0.30 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.33 -0.57 0.01 (loc) 5-6 5-6 5 l/defl >350 >202 n/a L/d 240 180 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud *Except* 3-5: 2x3 SPF No.2, 2-6: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 6=462/0-3-0, 5=379/0-1-8 Max Horz 6=130(LC 5) Max Uplift 6=-144(LC 4), 5=-122(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-494/256, 2-6=-359/175 BOT CHORD 5-6=-230/425 WEBS 3-5=-428/271 NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=144, 5=122. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T01 Truss Type Common Qty 3 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640294 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:29 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-dk0gjd?Mq9Yh5qLeDMYkedGgeWZ6B8MkKheZDhy7LuO Scale = 1:35.9 1 2 3 4 5 6 7 8 9 10 4x6 6x10 4x6 5x12 2x42x4 6x10 4x6 10-2-8 10-2-8 20-5-0 10-2-8 -1-0-0 1-0-0 5-2-8 5-2-8 10-2-8 5-0-0 15-2-8 5-0-0 20-5-0 5-2-8 21-5-0 1-0-0 0-10-05-1-10-10-05.00 12 Plate Offsets (X,Y)-- [2:0-6-3,Edge], [8:0-6-3,Edge], [10:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.23 0.71 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.39 0.05 (loc) 2-10 2-10 8 l/defl >999 >621 n/a L/d 240 180 n/a PLATES MT20 Weight: 74 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 2-10-1, Right 2x6 SPF No.2 2-10-1 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=877/0-3-8, 8=877/0-3-8 Max Horz 2=42(LC 6) Max Uplift 2=-73(LC 6), 8=-73(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1362/224, 4-5=-1053/159, 5-6=-1053/159, 6-8=-1362/224 BOT CHORD 2-10=-138/1160, 8-10=-138/1160 WEBS 5-10=0/504, 6-10=-312/137, 4-10=-312/137 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T02 Truss Type Half Hip Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640295 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:30 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-5xa2wz?_bSgYj_wrm33zBqop5w24wemuZLO6l7y7LuN Scale = 1:16.7 1 2 3 4 7 6 5 4x6 2x4 3x6 2x4 3x4 2-11-12 2-11-12 5-11-8 2-11-12 -1-0-0 1-0-0 5-0-0 5-0-0 5-11-8 0-11-8 0-9-02-5-02-1-80-3-82-5-04.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.38 0.09 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.01 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-6,3-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 7=302/0-3-8, 5=220/0-1-8 Max Horz 7=76(LC 5) Max Uplift 7=-53(LC 4), 5=-22(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-281/142 WEBS 3-5=-251/132 NOTES- (9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T03 Truss Type Half Hip Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640296 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:31 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-Z78Q8J0cMmoOL8V1KnaCj2LscJEOf1d1n_7gIay7LuM Scale = 1:24.6 1 2 3 4 7 6 5 2x4 3x4 4x6 2x4 5x10 MT18HS 8-9-8 8-9-8 9-11-8 1-2-0 -1-0-0 1-0-0 8-9-8 8-9-8 9-11-8 1-2-0 0-9-03-8-34.00 12 Plate Offsets (X,Y)-- [2:0-0-9,0-1-12], [3:0-5-0,0-1-13], [7:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.84 0.72 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.23 -0.37 0.00 (loc) 6-7 6-7 5 l/defl >513 >315 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 32 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=384/Mechanical, 7=461/0-3-0 Max Horz 7=118(LC 5) Max Uplift 5=-121(LC 4), 7=-144(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-330/206, 2-7=-404/223 WEBS 3-6=-451/548, 3-5=-823/679 NOTES- (10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) The Fabrication Tolerance at joint 2 = 12% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=121, 7=144. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T04 Truss Type Half Hip Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640297 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:32 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-1JipLf1E74wFyI4DuU5RGFu2QjgEOV0B0etDq0y7LuL Scale = 1:20.6 1 2 3 4 7 6 5 2x4 3x4 4x6 2x4 4x8 6-9-8 6-9-8 9-11-8 3-2-0 -1-0-0 1-0-0 6-9-8 6-9-8 9-11-8 3-2-0 0-9-03-0-34.00 12 Plate Offsets (X,Y)-- [2:0-0-9,0-1-12], [7:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.77 0.36 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.08 -0.14 0.01 (loc) 6-7 6-7 5 l/defl >999 >829 n/a L/d 240 180 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=384/Mechanical, 7=461/0-3-0 Max Horz 7=96(LC 5) Max Uplift 5=-118(LC 4), 7=-147(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-446/297, 2-7=-403/237 BOT CHORD 6-7=-233/359, 5-6=-240/364 WEBS 3-6=-193/251, 3-5=-484/375 NOTES- (9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) The Fabrication Tolerance at joint 2 = 16% 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=118, 7=147. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T05 Truss Type Half Hip Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640298 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:32 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-1JipLf1E74wFyI4DuU5RGFu3ojhEOTkB0etDq0y7LuL Scale = 1:20.3 1 2 3 4 7 6 5 4x6 2x4 3x4 6x6 2x4 4-9-8 4-9-8 9-11-8 5-2-0 -1-0-0 1-0-0 4-9-8 4-9-8 9-11-8 5-2-0 0-9-02-4-34.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-0-9], [3:0-4-0,0-2-0], [7:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.75 0.30 0.34 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.04 -0.07 0.01 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=384/Mechanical, 7=461/0-3-0 Max Horz 7=73(LC 5) Max Uplift 5=-116(LC 4), 7=-150(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-557/389, 2-7=-399/253 BOT CHORD 6-7=-325/477, 5-6=-333/481 WEBS 3-5=-480/366 NOTES- (9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) The Fabrication Tolerance at joint 2 = 16% 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=116, 7=150. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T06 Truss Type Roof Special Qty 8 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640299 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:33 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-VWGBZ?2suN36aSfQSCcgoTQEG70A7xXKFIcnMSy7LuK Scale = 1:25.0 1 2 3 4 6 5 2x4 6x6 2x4 6x6 9-11-8 9-11-8 4-11-12 4-11-12 9-11-8 4-11-12 10-11-8 1-0-0 3-9-54-0-130-3-8 0-9-04.00 12 Plate Offsets (X,Y)-- [1:0-2-0,0-0-8], [3:0-1-12,0-0-9], [5:0-1-12,0-0-0], [6:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.77 0.38 0.31 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.35 -0.61 -0.01 (loc) 5-6 5-6 6 l/defl >329 >190 n/a L/d 240 180 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud *Except* 2-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=459/0-3-0, 6=383/0-1-8 Max Horz 5=-129(LC 4) Max Uplift 5=-142(LC 5), 6=-124(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-503/259, 3-5=-357/174 BOT CHORD 5-6=-232/434 WEBS 2-6=-437/272 NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=142, 6=124. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T07 Truss Type Common Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640300 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:34 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-ziqZmL3UfhBzCcEc?v8vLgzLwXJtsNjTTyMKuuy7LuJ Scale = 1:32.8 1 2 3 4 5 9 8 7 6 4x6 3x6 5x8 3x63x4 2x4 3x6 8-6-12 8-6-12 17-1-8 8-6-12 -1-0-0 1-0-0 5-2-8 5-2-8 10-2-8 5-0-0 17-1-8 6-11-0 0-10-05-1-12-2-75.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.96 0.54 0.37 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.33 0.02 (loc) 6-8 6-8 6 l/defl >999 >609 n/a L/d 240 180 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-6: 2x4 SPF-S Stud, 2-9: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-6 REACTIONS. (lb/size) 9=746/0-3-8, 6=667/Mechanical Max Horz 9=69(LC 6) Max Uplift 9=-77(LC 6), 6=-25(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1005/172, 3-4=-780/129, 2-9=-657/178 BOT CHORD 8-9=-101/846, 6-8=-10/586 WEBS 4-8=0/411, 4-6=-598/25 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T08 Truss Type Common Qty 2 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640301 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:35 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-RuOxzh36Q?JqplpoZdf8uuWYCxjAbt6dic5tRLy7LuI Scale = 1:23.2 1 2 3 4 7 6 5 4x6 4x6 8x8 2x43x8 6-6-8 6-6-8 12-6-8 6-0-0 -1-0-0 1-0-0 6-6-8 6-6-8 12-6-8 6-0-0 0-10-03-6-111-0-115.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-1-12], [5:0-1-12,0-1-0], [7:Edge,0-5-11], [7:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.87 0.28 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.06 -0.10 0.01 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 44 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7,4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 7=562/0-3-0, 5=487/Mechanical Max Horz 7=47(LC 6) Max Uplift 7=-165(LC 6), 5=-126(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-633/417, 3-4=-620/417, 2-7=-503/299, 4-5=-434/257 BOT CHORD 6-7=-234/364 WEBS 4-6=-204/348 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=165, 5=126. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T09 Truss Type KINGPOST Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640302 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:36 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-w5yJB14lBIRhRvO?7KANQ52oQK46KKjmxGrRzny7LuH Scale = 1:23.0 1 2 3 6 5 4 2x4 2x4 4x6 4x6 4x6 3x8 6-0-0 6-0-0 12-0-0 6-0-0 6-0-0 6-0-0 12-0-0 6-0-0 1-0-113-6-111-0-115.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-12], [3:0-3-0,0-1-12], [4:0-1-12,0-1-0], [6:0-1-12,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.52 0.24 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.04 -0.07 0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6,3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 6=468/Mechanical, 4=468/Mechanical Max Horz 6=-23(LC 7) Max Uplift 6=-121(LC 6), 4=-121(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-581/391, 2-3=-581/391, 1-6=-414/245, 3-4=-414/245 WEBS 1-5=-176/312, 3-5=-176/312 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=121, 4=121. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T10 Truss Type Common Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640303 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:37 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-OHViOM5NycZY33yBh2hczJbzakKG3bzwAwa_VDy7LuG Scale = 1:49.6 1 2 3 4 5 6 7 8 9 14 13 12 11 1015 16 3x6 4x6 3x6 3x8 3x6 3x6 3x6 3x6 8x8 8x8 9-8-8 9-8-8 19-2-8 9-6-0 28-11-0 9-8-8 -1-0-0 1-0-0 7-4-0 7-4-0 14-5-8 7-1-8 21-7-0 7-1-8 28-11-0 7-4-0 29-11-0 1-0-0 0-10-06-10-50-10-05.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-0-12], [2:Edge,0-2-4], [8:0-1-12,0-0-12], [8:Edge,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.55 0.56 0.92 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.37 -0.59 0.08 (loc) 11-13 11-13 10 l/defl >925 >580 n/a L/d 240 180 n/a PLATES MT20 Weight: 104 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 2-14,8-10: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 7-10 REACTIONS. (lb/size) 14=1292/0-3-8, 10=1292/0-3-8 Max Horz 14=68(LC 6) Max Uplift 14=-94(LC 6), 10=-94(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-711/153, 3-5=-2013/299, 5-7=-2013/299, 7-8=-711/153, 2-14=-528/176, 8-10=-528/176 BOT CHORD 13-14=-173/1951, 11-13=-37/1386, 10-11=-173/1951 WEBS 5-11=-46/698, 7-11=-339/192, 5-13=-46/698, 3-13=-339/192, 3-14=-1533/153, 7-10=-1533/153 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 10. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T11 Truss Type Common Qty 2 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640304 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:38 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-sT34ci6?jwhPgDXNElCrVW88h8jvoF43OaKY1gy7LuF Scale = 1:25.5 1 2 3 4 5 8 7 6 4x6 8x8 8x83x8 6-11-8 6-11-8 13-11-0 6-11-8 -1-0-0 1-0-0 6-11-8 6-11-8 13-11-0 6-11-8 14-11-0 1-0-0 0-10-03-8-130-10-05.00 12 Plate Offsets (X,Y)-- [6:Edge,0-5-11], [6:0-1-12,0-0-0], [8:0-1-12,0-0-0], [8:Edge,0-5-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.53 0.34 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.12 0.01 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 50 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=614/0-3-8, 6=614/0-3-8 Max Horz 8=-39(LC 7) Max Uplift 8=-64(LC 6), 6=-64(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-728/118, 3-4=-728/118, 2-8=-553/169, 4-6=-553/169 BOT CHORD 7-8=-114/436, 6-7=-102/436 WEBS 3-7=0/269, 2-7=0/275, 4-7=0/275 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T12 Truss Type Common Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640305 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:39 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-KfdSp26dTDpGIN6ZoSj42kgICY2QXiGCdE35a6y7LuE Scale = 1:26.9 1 2 3 4 5 8 7 6 4x6 8x8 8x8 3x8 7-4-8 7-4-8 14-9-0 7-4-8 -1-0-0 1-0-0 7-4-8 7-4-8 14-9-0 7-4-8 15-9-0 1-0-0 0-10-03-10-140-10-05.00 12 Plate Offsets (X,Y)-- [6:Edge,0-5-11], [6:0-1-12,0-0-0], [8:0-1-12,0-0-0], [8:Edge,0-5-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.61 0.39 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.15 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=647/0-3-8, 6=647/0-3-8 Max Horz 8=-41(LC 7) Max Uplift 8=-65(LC 6), 6=-65(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-781/121, 3-4=-781/121, 2-8=-583/172, 4-6=-583/172 BOT CHORD 7-8=-131/496, 6-7=-117/496 WEBS 3-7=0/290, 2-7=-13/287, 4-7=-13/287 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T13 Truss Type Common Qty 13 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640306 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:41 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-G2lCEk8t?r3_XgGywtmY79mc6Lf1?PdV4YYCe_y7LuC Scale = 1:71.1 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 1118 19 20 21 3x6 5x6 3x6 3x16 MT18HS 4x8 3x4 3x4 4x6 3x4 3x4 4x6 8x8 3x16 MT18HS 8x8 10-7-0 10-7-0 20-11-8 10-4-8 31-4-0 10-4-8 41-11-0 10-7-0 7-1-8 7-1-8 14-0-8 6-11-0 20-11-8 6-11-0 27-10-8 6-11-0 34-9-8 6-11-0 41-11-0 7-1-8 42-11-0 1-0-0 0-10-09-6-130-10-05.00 12 Plate Offsets (X,Y)-- [1:Edge,0-2-4], [1:0-1-12,0-0-12], [4:0-1-12,0-1-8], [5:0-3-0,0-2-4], [6:0-1-12,0-1-8], [9:Edge,0-2-4], [9:0-1-12,0-0-12], [14:0-4-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.65 0.77 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.47 -0.89 0.19 (loc) 14-16 14-16 11 l/defl >999 >561 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 161 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 1-17,9-11: 2x4 SP 2400F 2.0E, 2-17,8-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-14, 4-14, 2-17, 8-11 REACTIONS. (lb/size) 17=1827/Mechanical, 11=1898/0-3-8 Max Horz 17=-102(LC 7) Max Uplift 17=-85(LC 6), 11=-121(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-641/100, 2-4=-3336/425, 4-5=-2452/387, 5-6=-2452/387, 6-8=-3328/421, 8-9=-811/151, 1-17=-418/101, 9-11=-572/177 BOT CHORD 16-17=-316/3145, 14-16=-198/2768, 12-14=-197/2768, 11-12=-309/3127 WEBS 5-14=-149/1443, 6-14=-825/197, 6-12=0/519, 4-14=-826/197, 4-16=0/530, 2-17=-2937/363, 8-11=-2752/305 NOTES- (8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17 except (jt=lb) 11=121. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T14 Truss Type Common Qty 7 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640307 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:42 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-kEJbS49Vm8Br9qr8TbHngMIkNl?PkssfJCIlARy7LuB Scale = 1:71.0 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 1017 18 19 20 3x6 5x6 3x6 3x16 MT18HS3x4 4x6 3x4 4x8 3x4 3x4 4x6 8x8 10x10 3x16 MT18HS 10-6-2 10-6-2 20-11-8 10-5-6 31-1-6 10-1-14 41-7-8 10-6-2 7-1-8 7-1-8 14-0-8 6-11-0 20-11-8 6-11-0 27-9-5 6-9-13 34-7-3 6-9-13 41-7-8 7-0-5 0-10-09-6-130-11-75.00 12 Plate Offsets (X,Y)-- [1:Edge,0-2-8], [1:0-1-12,0-0-12], [4:0-1-12,0-1-8], [5:0-3-0,0-2-4], [6:0-1-12,0-1-8], [9:0-1-12,0-0-12], [9:Edge,0-3-4], [13:0-4-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.87 0.76 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.47 -0.91 0.19 (loc) 13-15 13-15 10 l/defl >999 >547 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 158 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 1-16,9-10: 2x4 SPF-S Stud, 2-16,8-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-13, 6-13, 2-16, 8-10 REACTIONS. (lb/size) 16=1816/Mechanical, 10=1816/Mechanical Max Horz 16=82(LC 6) Max Uplift 16=-84(LC 6), 10=-83(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-615/100, 2-4=-3316/423, 4-5=-2423/385, 5-6=-2421/385, 6-8=-3236/417, 8-9=-496/89, 1-16=-407/101, 9-10=-357/95 BOT CHORD 15-16=-341/3125, 13-15=-223/2742, 11-13=-216/2707, 10-11=-327/3014 WEBS 4-15=0/537, 4-13=-826/198, 5-13=-147/1421, 6-13=-791/191, 6-11=0/485, 2-16=-2941/360, 8-10=-2961/363 NOTES- (8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T15 Truss Type Common Qty 3 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640308 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:44 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-hdQLsmAmImRYP8?Xb0JFlnO4aZgkCmFynWnsFJy7Lu9 Scale = 1:71.0 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 1017 18 19 20 3x6 5x6 3x6 3x16 MT18HS 4x8 3x4 3x4 4x6 3x4 3x4 4x6 8x8 8x8 3x16 MT18HS 10-7-0 10-7-0 20-11-8 10-4-8 31-4-0 10-4-8 41-11-0 10-7-0 7-1-8 7-1-8 14-0-8 6-11-0 20-11-8 6-11-0 27-10-8 6-11-0 34-9-8 6-11-0 41-11-0 7-1-8 0-10-09-6-130-10-05.00 12 Plate Offsets (X,Y)-- [1:Edge,0-2-8], [1:0-1-12,0-0-12], [4:0-1-12,0-1-8], [5:0-3-0,0-2-4], [6:0-1-12,0-1-8], [9:Edge,0-2-8], [9:0-1-12,0-0-12], [13:0-4-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.89 0.77 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.47 -0.89 0.19 (loc) 13-15 13-15 10 l/defl >999 >559 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 159 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 1-16,9-10: 2x4 SPF-S Stud, 2-16,8-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-13, 4-13, 2-16, 8-10 REACTIONS. (lb/size) 16=1828/0-3-8, 10=1828/0-3-8 Max Horz 16=-81(LC 7) Max Uplift 16=-85(LC 6), 10=-85(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-621/98, 2-4=-3339/426, 4-5=-2454/388, 5-6=-2454/388, 6-8=-3339/426, 8-9=-621/98, 1-16=-409/100, 9-10=-409/100 BOT CHORD 15-16=-343/3147, 13-15=-224/2770, 11-13=-224/2770, 10-11=-343/3147 WEBS 5-13=-149/1443, 6-13=-826/197, 6-11=0/530, 4-13=-826/197, 4-15=0/530, 2-16=-2960/366, 8-10=-2960/366 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss T16 Truss Type Common Qty 4 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640309 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:45 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-9p_j46BO33ZP0Iaj9jqUH?wNTzz0xKM5?AWPnmy7Lu8 Scale = 1:40.3 1 2 3 4 5 6 7 8 9 4x6 8x8 4x6 4x6 8x8 4x6 4x6 5x12 2x42x4 11-11-8 11-11-8 23-11-0 11-11-8 -1-0-0 1-0-0 6-1-0 6-1-0 11-11-8 5-10-8 17-10-0 5-10-8 23-11-0 6-1-0 0-10-05-9-130-10-05.00 12 Plate Offsets (X,Y)-- [9:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.37 0.95 0.44 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.72 0.07 (loc) 8-9 8-9 8 l/defl >999 >397 n/a L/d 240 180 n/a PLATES MT20 Weight: 85 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 3-3-12, Right 2x6 SPF No.2 3-3-12 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (lb/size) 8=955/Mechanical, 2=1018/0-3-8 Max Horz 2=-54(LC 7) Max Uplift 8=-48(LC 7), 2=-80(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1643/273, 4-5=-1260/191, 5-6=-1260/191, 6-8=-1647/276 BOT CHORD 2-9=-168/1414, 8-9=-172/1420 WEBS 5-9=-4/610, 6-9=-402/172, 4-9=-396/167 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG01 Truss Type Half Hip Girder Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640310 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:46 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-d0Y5HRC0qNhGeS9wiQLjqCTY8MStgsOEEqGzJCy7Lu7 Scale = 1:13.6 1 2 3 4 7 6 5 8 9 10 11 2x4 3x43x6 2x4 4x8 3-0-0 3-0-0 5-11-8 2-11-8 -1-0-0 1-0-0 3-0-0 3-0-0 5-11-8 2-11-8 0-9-01-9-04.00 12 Plate Offsets (X,Y)-- [3:0-5-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.37 0.34 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=237/Mechanical, 7=318/0-3-8 Max Horz 7=53(LC 4) Max Uplift 5=-24(LC 4), 7=-57(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-278/23, 2-7=-270/73 NOTES- (10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 11 lb down and 20 lb up at 2-0-4, and 10 lb down and 24 lb up at 4-0-4 on top chord, and 11 lb down at 2-0-4, and 12 lb down at 4-0-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 8=-10(F) 9=-10(F) 10=-5(F) 11=-8(F) December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG02 Truss Type Half Hip Girder Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640311 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:47 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-5C6UVnDebhp7Gbj6G8tyNQ0cummePCrOTU?Wsey7Lu6 Scale = 1:20.3 1 2 3 4 7 6 5 8 9 10 11 12 13 14 15 4x8 3x6 4x66x62x4 2-9-8 2-9-8 9-11-8 7-2-0 -1-0-0 1-0-0 2-9-8 2-9-8 9-11-8 7-2-0 0-9-01-8-34.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-0-9], [3:0-5-0,0-2-0], [7:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.82 0.50 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.23 0.01 (loc) 5-6 5-6 5 l/defl >999 >506 n/a L/d 240 180 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-7: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-7 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=401/Mechanical, 7=483/0-3-0 Max Horz 7=51(LC 12) Max Uplift 5=-39(LC 4), 7=-74(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-701/46, 2-7=-412/66 BOT CHORD 6-7=-65/624, 5-6=-55/630 WEBS 3-5=-475/27 NOTES- (12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The Fabrication Tolerance at joint 2 = 16% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 51 lb down and 22 lb up at 2-0-4, 5 lb down and 22 lb up at 4-0-4, and 5 lb down and 22 lb up at 6-0-4, and 5 lb down and 22 lb up at 8-0-4 on top chord, and 7 lb down at 2-0-4, 8 lb down at 4-0-4, and 8 lb down at 6-0-4, and 8 lb down at 8-0-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Continued on page 2 December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG02 Truss Type Half Hip Girder Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640311 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:47 2018 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-5C6UVnDebhp7Gbj6G8tyNQ0cummePCrOTU?Wsey7Lu6 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 8=-16(B) 9=-3(B) 10=-3(B) 11=-3(B) 12=-2(B) 13=-5(B) 14=-5(B) 15=-5(B) 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG03 Truss Type Roof Special Girder Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640312 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:48 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-ZOgsi7DGM_x_tlIIqrOBvdYoKA3q8dmXh8l3O4y7Lu5 Scale = 1:24.9 1 2 3 4 7 6 5 8 9 103x8 3x4 8x8 3x8 6x6 5-1-3 5-1-3 9-11-8 4-10-5 5-1-3 5-1-3 9-11-8 4-10-5 10-11-8 1-0-0 4-0-130-9-04.00 12 Plate Offsets (X,Y)-- [5:0-1-12,0-0-0], [5:Edge,0-5-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.71 0.69 0.66 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.11 -0.22 -0.02 (loc) 6-7 6-7 7 l/defl >999 >517 n/a L/d 240 180 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-7 REACTIONS. (lb/size) 7=1248/Mechanical, 5=1068/0-3-0 Max Horz 5=-129(LC 3) Max Uplift 7=-329(LC 6), 5=-216(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1820/400, 3-5=-911/236 BOT CHORD 6-7=-387/1680, 5-6=-155/484 WEBS 2-7=-1767/434, 2-6=-201/944, 3-6=-286/1203 NOTES- (8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=329, 5=216. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 365 lb down and 133 lb up at 1-1-4, 364 lb down and 130 lb up at 3-1-4, and 364 lb down and 128 lb up at 5-1-4, and 381 lb down and 51 lb up at 7-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=-364(B) 8=-365(B) 9=-364(B) 10=-381(B) December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG04 Truss Type Half Hip Girder Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640313 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:49 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-1bEEwTEu7I4rVvtUOZvQSr57WaWqtEHhwoUdwXy7Lu4 Scale = 1:9.8 1 2 3 6 4 7 5 3x4 3x6 1-3-5 1-3-5 2-9-8 1-6-3 -1-0-0 1-0-0 1-11-8 1-11-8 2-9-8 0-10-0 0-9-01-4-130-3-81-1-51-4-134.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.11 0.13 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=73/Mechanical, 6=186/0-3-0, 5=21/Mechanical Max Horz 6=28(LC 5) Max Uplift 4=-24(LC 4), 6=-46(LC 3) Max Grav 4=76(LC 10), 6=186(LC 1), 5=47(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 14 lb up at 2-8-12, and 23 lb down and 10 lb up at 1-11-8 on top chord, and 1 lb down and 4 lb up at 1-11-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-6=-20 Concentrated Loads (lb) Vert: 4=-9(F) 7=4(F) December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG05 Truss Type Half Hip Girder Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640314 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:50 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-Vnoc7pFXucCi73ShxGQf_2dID_sjchWq9SEATzy7Lu3 Scale = 1:9.8 1 2 3 6 4 7 5 3x4 3x6 1-11-8 1-11-8 3-0-0 1-0-8 -1-0-0 1-0-0 1-11-8 1-11-8 3-0-0 1-0-8 0-9-01-4-131-1-51-4-134.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.11 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.01 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=70/Mechanical, 6=193/0-3-8, 5=24/Mechanical Max Horz 6=28(LC 5) Max Uplift 4=-22(LC 3), 6=-46(LC 3) Max Grav 4=70(LC 1), 6=193(LC 1), 5=51(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 56 lb down and 19 lb up at 1-11-8 on top chord, and 0 lb down and 4 lb up at 1-11-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-6=-20 Concentrated Loads (lb) Vert: 7=4(B) December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG06 Truss Type COMMON GIRDER Qty 1 Ply 3 125 Woods at Shelborne Job Reference (optional) I35640315 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:52 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-SAvMYVGnQDSQMNc33hS74TjbenR84QZ7cmjHXsy7Lu1 Scale: 1/4"=1' 1 2 3 4 5 6 7 13 12 11 10 9 814 15 16 17 18 19 20 21 22 23 24 25 266x16 5x8 6x166x18 MT18HS 10x10 4x6 8x8 4x6 3x6 4x6 8x8 4x6 3x6 4-3-12 4-3-12 9-8-13 5-5-2 14-5-8 4-8-11 19-2-3 4-8-11 24-7-4 5-5-2 28-11-0 4-3-12 4-3-12 4-3-12 9-8-13 5-5-2 14-5-8 4-8-11 19-2-3 4-8-11 24-7-4 5-5-2 28-11-0 4-3-12 0-10-06-10-50-10-05.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-0-10], [2:0-2-4,0-2-0], [3:0-2-4,0-1-8], [4:0-3-12,0-2-8], [5:0-2-4,0-1-8], [6:0-2-4,0-2-0], [7:0-0-0,0-0-10], [8:0-3-12,0-1-8], [9:0-3-8,0-4-12], [12:0-3-8,0-4-12], [13:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.31 0.60 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.20 -0.46 0.15 (loc) 12-13 12-13 7 l/defl >999 >749 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 617 lb FT = 20% GRIP 169/123 244/190 LUMBER- TOP CHORD 2x6 SP 2400F 2.0E BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 4-10: 2x4 SPF 2100F 1.8E, 5-9,3-12: 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=13232/0-3-8 (req. 0-3-10), 7=14294/0-3-8 (req. 0-3-15) Max Horz 1=-59(LC 6) Max Uplift 1=-704(LC 5), 7=-761(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-26604/1415, 2-3=-22772/1230, 3-4=-17742/987, 4-5=-17742/987, 5-6=-22721/1229, 6-7=-26612/1422 BOT CHORD 1-13=-1285/23735, 12-13=-1285/23735, 10-12=-1086/21000, 9-10=-1026/20951, 8-9=-1231/23760, 7-8=-1231/23760 WEBS 4-10=-678/13108, 5-10=-6235/404, 5-9=-267/5882, 6-9=-3046/220, 6-8=-159/4028, 3-10=-6302/405, 3-12=-269/5940, 2-12=-2966/213, 2-13=-158/4016 NOTES- (11-12) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 3 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 5-9 2x4 - 1 row at 0-5-0 oc, member 3-12 2x4 - 1 row at 0-5-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) WARNING: Required bearing size at joint(s) 1, 7 greater than input bearing size. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=704, 7=761. Continued on page 2 December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG06 Truss Type COMMON GIRDER Qty 1 Ply 3 125 Woods at Shelborne Job Reference (optional) I35640315 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:52 2018 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-SAvMYVGnQDSQMNc33hS74TjbenR84QZ7cmjHXsy7Lu1 NOTES- (11-12) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1807 lb down and 97 lb up at 2-0-12, 1807 lb down and 97 lb up at 4-0-12, 1807 lb down and 97 lb up at 6-0-12, 1807 lb down and 97 lb up at 8-0-12, 1807 lb down and 97 lb up at 10-0-12, 1807 lb down and 97 lb up at 12-0-12, 1807 lb down and 97 lb up at 14-0-12, 1807 lb down and 97 lb up at 16-0-12, 1796 lb down and 96 lb up at 18-0-12, 1796 lb down and 96 lb up at 20-0-12, 1796 lb down and 96 lb up at 22-0-12, 1796 lb down and 96 lb up at 24-0-12, and 1796 lb down and 96 lb up at 26-0-12, and 1799 lb down and 95 lb up at 28-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 1-7=-20 Concentrated Loads (lb) Vert: 13=-1807(F) 14=-1807(F) 15=-1807(F) 16=-1807(F) 17=-1807(F) 18=-1807(F) 19=-1807(F) 20=-1807(F) 21=-1796(F) 22=-1796(F) 23=-1796(F) 24=-1796(F) 25=-1796(F) 26=-1799(F) 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG07 Truss Type COMMON GIRDER Qty 1 Ply 3 125 Woods at Shelborne Job Reference (optional) I35640316 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:53 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-wMTllrHPAXaH_WBGdPzMchFgPBolpxaGrQSq3Iy7Lu0 Scale = 1:24.5 1 2 3 4 5 6 7 10 9 811 12 13 14 15 16 6x16 4x10 4x6 6x16 4x10 8x8 3x6 3x6 3x6 3x6 3-10-0 3-10-0 7-4-8 3-6-8 10-11-0 3-6-8 14-9-0 3-10-0 3-10-0 3-10-0 7-4-8 3-6-8 10-11-0 3-6-8 14-9-0 3-10-0 0-10-03-10-140-10-05.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-12], [3:0-2-8,0-1-8], [5:0-2-8,0-1-8], [7:0-0-0,0-2-7], [8:0-3-8,0-1-8], [10:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.69 0.51 0.49 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.16 0.04 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 213 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 4-9: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 2-0-4, Right 2x4 SPF-S Stud 2-0-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=7284/0-3-8, 7=6471/0-3-8 Max Horz 1=-33(LC 14) Max Uplift 1=-383(LC 5), 7=-341(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-10908/587, 3-4=-8603/475, 4-5=-8601/475, 5-7=-10811/583 BOT CHORD 1-10=-516/9790, 9-10=-516/9790, 8-9=-478/9687, 7-8=-478/9687 WEBS 4-9=-294/6017, 5-9=-2013/157, 5-8=-98/2512, 3-9=-2133/163, 3-10=-101/2580 NOTES- (9-10) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 5-8 2x4 - 2 rows staggered at 0-4-0 oc, member 3-10 2x4 - 2 rows staggered at 0-4-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=383, 7=341. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1797 lb down and 95 lb up at 0-10-12, 1796 lb down and 95 lb up at 2-10-12, 1796 lb down and 95 lb up at 4-10-12, 1796 lb down and 95 lb up at 6-10-12, 1796 lb down and 95 lb up at 8-10-12, and 1796 lb down and 95 lb up at 10-10-12, and 1796 lb down and 95 lb up at 12-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG07 Truss Type COMMON GIRDER Qty 1 Ply 3 125 Woods at Shelborne Job Reference (optional) I35640316 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:53 2018 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-wMTllrHPAXaH_WBGdPzMchFgPBolpxaGrQSq3Iy7Lu0 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 1-7=-20 Concentrated Loads (lb) Vert: 8=-1796(B) 11=-1797(B) 12=-1796(B) 13=-1796(B) 14=-1796(B) 15=-1796(B) 16=-1796(B) 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG08 Truss Type COMMON GIRDER Qty 1 Ply 2 125 Woods at Shelborne Job Reference (optional) I35640317 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:55 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-skbVAWJfi8q?DqLekp0qh6Lz9_UFHlDZIjxx8By7Lu_ Scale = 1:23.0 1 2 3 4 5 6 7 9 8 10 11 12 13 14 156x16 4x8 4x8 6x16 4x8 8x8 2x4 8x8 2x4 4-8-8 4-8-8 9-2-8 4-6-0 13-11-0 4-8-8 3-7-0 3-7-0 6-11-8 3-4-8 10-4-0 3-4-8 13-11-0 3-7-0 0-10-03-8-130-10-05.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-12], [1:1-2-11,0-2-10], [4:0-4-0,0-1-0], [7:0-0-0,0-2-7], [7:1-2-7,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.87 0.51 0.87 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.17 0.03 (loc) 8-9 8-9 7 l/defl >999 >981 n/a L/d 240 180 n/a PLATES MT20 Weight: 129 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-10-11, Right 2x4 SPF-S Stud 1-10-11 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=4330/0-3-8, 7=3539/0-3-8 Max Horz 1=31(LC 5) Max Uplift 1=-264(LC 5), 7=-220(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-6491/427, 3-4=-6499/434, 4-5=-5843/392, 5-7=-5849/385 BOT CHORD 1-9=-372/5834, 8-9=-231/4241, 7-8=-302/5210 WEBS 4-8=-135/2089, 5-8=-9/456, 4-9=-205/3173, 3-9=-9/421 NOTES- (9-10) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=264, 7=220. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1808 lb down and 97 lb up at 2-0-12, 1207 lb down and 92 lb up at 3-10-4, 935 lb down and 60 lb up at 5-10-4, 935 lb down and 60 lb up at 7-10-4, and 935 lb down and 60 lb up at 9-10-4, and 935 lb down and 60 lb up at 11-10-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss TG08 Truss Type COMMON GIRDER Qty 1 Ply 2 125 Woods at Shelborne Job Reference (optional) I35640317 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:55 2018 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-skbVAWJfi8q?DqLekp0qh6Lz9_UFHlDZIjxx8By7Lu_ LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 1-7=-20 Concentrated Loads (lb) Vert: 10=-1808(B) 11=-1207(B) 12=-935(B) 13=-935(B) 14=-935(B) 15=-935(B) 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V01 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640318 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:57 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-o7jFbCKwEl4iS8U1sE2InXQTsoFXlrRsm1Q2B3y7Lty Scale = 1:39.6 1 2 3 4 5 6 7 13 1211 10 9 814 16 17 15 3x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-8-12 24-8-12 12-4-6 12-4-6 24-8-12 12-4-6 0-0-45-1-130-0-45.00 12 Plate Offsets (X,Y)-- [11:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.15 0.14 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 67 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 24-8-12. (lb) - Max Horz 1=45(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=439(LC 1), 12=361(LC 10), 13=332(LC 1), 9=361(LC 11), 8=332(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-259/119, 5-9=-259/119 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 9, 8. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V02 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640319 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:57 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-o7jFbCKwEl4iS8U1sE2InXQP8oCHlr5sm1Q2B3y7Lty Scale = 1:33.2 1 2 3 4 5 9 8 7 63x4 4x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 20-8-12 20-8-12 10-4-6 10-4-6 20-8-12 10-4-6 0-0-44-3-130-0-45.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.39 0.35 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-9: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 20-8-12. (lb) - Max Horz 1=-38(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=490(LC 10), 6=486(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-350/151, 4-6=-345/150 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V03 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640320 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:58 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-GJHeoYLY?3CZ4I3DPyZXJkzbtCb1UIZ??hAbkVy7Ltx Scale = 1:26.8 1 2 3 4 5 9 8 7 63x4 3x6 3x42x4 2x4 2x4 2x4 2x4 2x4 16-8-12 16-8-12 8-4-6 8-4-6 16-8-12 8-4-6 0-0-43-5-130-0-45.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.32 0.19 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 16-8-12. (lb) - Max Horz 1=-31(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=269(LC 1), 9=372(LC 10), 6=372(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-274/123, 4-6=-274/123 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 9, 6. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V04 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640321 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:06:59 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-kWq00uMAmNKQiRePzf4msyVkPcumDkj9DLv9Gyy7Ltw Scale = 1:20.4 1 2 3 43x6 4x6 3x62x4 12-8-12 12-8-12 6-4-6 6-4-6 12-8-12 6-4-6 0-0-42-7-130-0-45.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [2:0-3-0,0-2-8], [3:0-0-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.46 0.35 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=194/12-8-12, 3=194/12-8-12, 4=510/12-8-12 Max Horz 1=-22(LC 7) Max Uplift 1=-21(LC 6), 3=-24(LC 7), 4=-5(LC 6) Max Grav 1=200(LC 10), 3=200(LC 11), 4=510(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-313/112 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V05 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640322 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:00 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-DiOODENoXgSHJbDcXNb?O92vt?FayCNIS?fioOy7Ltv Scale: 3/4"=1' 1 2 3 4 2x4 3x4 2x42x4 8-8-12 8-8-12 4-4-6 4-4-6 8-8-12 4-4-6 0-0-41-9-130-0-45.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.48 0.31 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=150/8-8-12, 3=150/8-8-12, 4=310/8-8-12 Max Horz 1=15(LC 6) Max Uplift 1=-21(LC 6), 3=-24(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V06 Truss Type Valley Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640323 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:00 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:TvT3THv6RQv8BfIzDejylNy7M3a-DiOODENoXgSHJbDcXNb?O92?i?FuyC?IS?fioOy7Ltv Scale = 1:8.7 1 2 3 2x4 2x4 2x4 0-0-10 0-0-10 4-8-12 4-8-2 2-4-6 2-4-6 4-8-12 2-4-6 0-0-40-11-130-0-45.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.11 0.29 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=145/4-7-8, 3=145/4-7-8 Max Horz 1=7(LC 6) Max Uplift 1=-7(LC 6), 3=-7(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V07 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640324 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:01 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-huymRaNQI_a8xloo447ExNb6dPcjhcJShfPFKqy7Ltu Scale = 1:59.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x6 4x6 3x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 3x6 36-3-12 36-3-12 18-1-14 18-1-14 36-3-12 18-1-14 0-0-47-6-120-0-45.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-10], [11:0-3-0,0-1-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.35 0.25 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 381 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-2,10-11: 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 *Except* 15-17: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 36-3-12. (lb) - Max Horz 1=68(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 18, 19, 20, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11 except 16=423(LC 1), 18=527(LC 10), 19=346(LC 1), 20=449(LC 10), 14=527(LC 11), 13=346(LC 1), 12=449(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-18=-267/120, 3-20=-321/141, 7-14=-267/120, 9-12=-321/141 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 19, 20, 14, 13, 12. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V08 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640325 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:02 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-95W8ewO23Ii?ZvN_eoeTUa7JCpwVQ3KbwJ8ptHy7Ltt Scale = 1:52.5 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 122022 2321 3x6 4x6 3x6 3x4 3x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 32-3-12 32-3-12 16-1-14 16-1-14 32-3-12 16-1-14 0-0-46-8-120-0-45.00 12 Plate Offsets (X,Y)-- [15:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.24 0.28 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 92 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3,9-11: 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 *Except* 15-16: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 32-3-12. (lb) - Max Horz 1=-60(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 19, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11 except 15=441(LC 1), 17=503(LC 10), 18=332(LC 1), 19=326(LC 10), 14=490(LC 11), 13=337(LC 1), 12=325(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-17=-260/117, 7-14=-260/117 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 19, 14, 13, 12. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V09 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640326 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:03 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-dH4XsFPgqbqsA3yBCV9i0ogSZDHc9XDl8zuMPjy7Lts Scale = 1:45.4 1 2 3 4 5 6 7 13 12 11 10 9 83x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 28-3-12 28-3-12 14-1-14 14-1-14 28-3-12 14-1-14 0-0-45-10-120-0-45.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [7:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.33 0.23 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 79 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 28-3-12. (lb) - Max Horz 1=-52(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 7, 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=481(LC 1), 12=371(LC 10), 13=441(LC 1), 9=371(LC 11), 8=441(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-13=-316/139, 6-8=-316/139 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 12, 13, 9, 8. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V10 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640327 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:04 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-5Tev3bQJbvyjoDXNmCgxZ?Dg2deLu?EuNddwx9y7Ltr Scale = 1:39.0 1 2 3 4 5 6 7 12 11 10 9 813 15 16 14 3x4 4x6 3x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-3-12 24-3-12 12-1-14 12-1-14 24-3-12 12-1-14 0-0-45-0-120-0-45.00 12 Plate Offsets (X,Y)-- [11:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.15 0.13 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 66 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 24-3-12. (lb) - Max Horz 1=45(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 11, 12, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 11=356(LC 10), 10=429(LC 1), 12=324(LC 1), 9=359(LC 11), 8=322(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-257/118, 5-9=-261/120 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 12, 9, 8. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V11 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640328 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:05 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-ZgCHGxRxMD5aQM5ZJwBA5DloU0xYdS81cHNTTby7Ltq Scale = 1:32.6 1 2 3 4 5 9 8 7 63x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 20-3-12 20-3-12 10-1-14 10-1-14 20-3-12 10-1-14 0-0-44-2-120-0-45.00 12 Plate Offsets (X,Y)-- [1:0-1-10,0-0-0], [5:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.36 0.32 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-9: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 20-3-12. (lb) - Max Horz 1=-37(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=475(LC 10), 6=471(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-341/147, 4-6=-336/146 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V12 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640329 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:06 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-1smfUHRZ6WDR1WgmtdiPeQI_4QK6MwZBqx6002y7Ltp Scale = 1:26.2 1 2 3 4 5 9 8 7 63x4 3x6 3x42x4 2x4 2x4 2x4 2x4 2x4 16-3-12 16-3-12 8-1-14 8-1-14 16-3-12 8-1-14 0-0-43-4-120-0-45.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.31 0.17 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 16-3-12. (lb) - Max Horz 1=-30(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=274(LC 1), 9=361(LC 10), 6=361(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-268/121, 4-6=-268/121 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 9, 6. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V13 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640330 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:07 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-V2J1hdSBtqLIfgFyRLDeBer7rqdg5NnK3bsaYUy7Lto Scale = 1:19.7 1 2 3 43x12 3x8 3x122x4 12-3-12 12-3-12 6-1-14 6-1-14 12-3-12 6-1-14 0-0-42-6-120-0-45.00 12 Plate Offsets (X,Y)-- [1:0-9-8,Edge], [3:0-4-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.44 0.35 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=185/12-3-12, 3=185/12-3-12, 4=495/12-3-12 Max Horz 1=-22(LC 7) Max Uplift 1=-20(LC 6), 3=-23(LC 7), 4=-5(LC 6) Max Grav 1=191(LC 10), 3=191(LC 11), 4=495(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-288/105 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V14 Truss Type Valley Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640331 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:07 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-V2J1hdSBtqLIfgFyRLDeBer7wqek5N9K3bsaYUy7Lto Scale = 1:15.2 1 2 3 4 2x4 3x4 2x42x4 0-0-10 0-0-10 8-3-12 8-3-2 4-1-14 4-1-14 8-3-12 4-1-14 0-0-41-8-120-0-45.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.43 0.28 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=142/8-2-8, 3=142/8-2-8, 4=293/8-2-8 Max Horz 1=-14(LC 7) Max Uplift 1=-20(LC 6), 3=-23(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V15 Truss Type Valley Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640332 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:08 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-_FtQvzTpe8T8Hqq8?2ltjrNN3E_jqq_UIFb74wy7Ltn Scale: 1.5"=1' 1 2 3 2x4 2x4 2x4 0-0-10 0-0-10 4-3-12 4-3-2 2-1-14 2-1-14 4-3-12 2-1-14 0-0-40-10-120-0-45.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.09 0.23 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=128/4-2-8, 3=128/4-2-8 Max Horz 1=-6(LC 7) Max Uplift 1=-7(LC 6), 3=-7(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 125_Woods_at_Shelborne Truss V16 Truss Type GABLE Qty 1 Ply 1 125 Woods at Shelborne Job Reference (optional) I35640333 8.220 s Nov 16 2018 MiTek Industries, Inc. Wed Dec 19 16:07:09 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dHgyFp7oglwYJLmjLVvlkrza3DW-SRRo6JURPRb?u_PKYmG6G3wVheIFZHTdXvLhdNy7Ltm Scale = 1:17.8 1 2 3 4 3x4 3x6 3x42x4 9-8-12 9-8-12 4-10-6 4-10-6 9-8-12 4-10-6 0-0-42-0-50-0-45.00 12 Plate Offsets (X,Y)-- [1:0-2-15,0-1-8], [3:0-1-1,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.29 0.34 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=149/9-8-12, 3=149/9-8-12, 4=391/9-8-12 Max Horz 1=17(LC 6) Max Uplift 1=-16(LC 6), 3=-19(LC 7), 4=-3(LC 6) Max Grav 1=154(LC 10), 3=154(LC 11), 4=391(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). December 20,2018 01/11/19 Mike Sheeks PRODUCT CODE APPROVALS LATERAL BRACING LOCATION Indicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the platewidth measured perpendicularto slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside" 16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS.W4- 6 W3-6W3-7 W2-7W1-7C1-8 C5-6C6-7C7-8 C4-5 C3-4C2-3C1-2 TOP CHORD TOP CHORD 8 7 6 54321 BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates therequired direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1" 4/3PLATE LOCATION AND ORIENTATION Symbols Numbering System General Safety Notes* Plate location details available in MiTek 20/20 software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8 WEBS Trusses are designed for wind loads in the plane of thetruss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1section 6.3 These truss designs rely on lumber valuesestablished by others.dimensions shown in ft-in-sixteenths 01/11/19 Mike Sheeks