HomeMy WebLinkAboutCJ181033.0189ARev1Report Number: Service Date: Report Date: Task: Client Carmel, IN 46032 3030 West 116th St. West Park: The GrovesGibraltar Construction Corp Attn: Douglas Perry 2932 N Webster Ave Indianapolis, IN 46219 317-273-1690 Indianapolis, IN 46214-2988 7770 W New York St CJ181033.0189A 12/12/18 01/14/19 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: CJ181033 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 4001CC/17002 IMI Material Information 1123 2236 Plant: Ticket No.: 109 10949720 Field Test Data Test Air Content (%): Result Specification 4 1/4 3 - 6 5.4 4.5 - 7.5 59 50 - 90 40 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:12/12/18 1200 Jamie Conwell CLOUDY 4 4 0 0 South side of building " center of front"Sample Location: Placement Method:Buggy Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): S/APlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) Tested By 1 A 4.00 12.57 12/17/18 12/19/18 7 47,340 1 3,770 JLT 1 B 4.00 12.57 12/17/18 01/09/19 28 63,990 3 5,090 JLT 1 C 4.00 12.57 12/17/18 01/09/19 28 62,950 3 5,010 JLT 1 D 4.00 12.57 12/17/18 01/09/19 28 65,310 4 5,200 JLT Average (28 days) 5,100 Initial Cure:Final Cure:Outside Water Storage Tank Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Not tested for plastic unit weight. Samples Made By: Earth Exploration, Inc. Sample fresh concrete at the placement locations, perform required field tests and cast compressive strength samples.Services: Reported To: Contractor: Report Distribution: (1) Gibraltar Construction Corp, Douglas Perry (1) City of Carmel IN, Mike Sheeks (1) Johnson Wilbur Adams, Inc., Michael Wilbur (1) Smith Group JJR, Jessie Fink Jeremy Clem Project Manager Ron Hueston with Gibraltar Construction Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Earth Exploration, Inc. Rep.: Jamie Conwell The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6