HomeMy WebLinkAboutMinutes TAC 05-23-85 I, �r /
TECHNICAL ADVISORY COMMITTEE
MINUTES - MAY 23, 1985
COMMITTEE MEMBERS PRESENT: Chuck Kiphart, Kent Ward, Stan Puckett, Dave Rickard,
Tom Schellenberger, Kurt Woerner, Boone Clark,
Tom Welch
SUMMERLAKES SUBDIVISION
Docket No. 26-85 P.P. , Primary Plat, West of Deerfield, S-1, 2 subdivision variances
Petitioners Present: Mr. Cohen, John Schneider, Bruce Nicholson, Phil Nicely
. Streets are to be private per proposed variance, road built to County
standards.
. Need letter from Hamilton County Health Department on septic systems.
. Need letter from Steve Couts, Carmel Fire Chief, on location of fire
hydrants.
. This project will drain into Marion County. Will request letter from Marion
County Department of Public Works as to status of adequate off-site
drainage facilities. SCS feels that off-site facilities are inadequate.
. Will need letter from County Surveyor, Kent Ward, on on-site drainage
proposed.
. All letters will need to be in Dept. of Community Development file by no
later than 4:00 P.M. June 3, 1985.
. 20' drainage and utility easement to be provided between Lots 84 and 88 and
Lots 67 and 68 to lakes.
. Section 6. 3.4 (Page 32) of Carmel Subdivision Regulations requires the
"continuation of existing, planned, or platted streets on adjacent
tracts , unless such continuation shall be prevented to topography or
other physical condition, or unless such extension is found by the Commission
to be unnecessary for the coordination of development between the subdivision
and such adjacent tract. "
. Flood routing between lakes is provided for.
. Letter needed from Charles Whitsitt on subdivision curb cut and improvements
to 96th Street.
. Accel/decel facilities are per County Highway Superintendent request.
. Roadside drainage facility will be improved on north side of 96th Street
by developer.
. Developer will contribute to County road fund for improvements to 96th St.
. The entire on-site drainage system will be incorporated (recorded)
into County regulated drainage system.
TAC RECOMMENDS APPROVAL OF PROPOSAL PER ABOVE CONDITIONS ,
TECHNICAL PDVISORY COMMITTEE �� ,* ,
MINUTES OF MAY 23, 1985
PAGE 2
BRADFORD PLACE
Docket No. 22-85 S.P. , North 116th Street, Carmel . Secondary Plat.
Petitioners Present: Jim Nelson, Ray Roehling, Steve Bourquein
. Add flood way line on plat/setback line.
. Tie down rear drainage easement.
. Need letter from Indiana Dept. of Natural Resources concerning fill in
flood plain of Cool Creek. Plat cannot be signed until letter is on
file at Dept. of Community Development.
. Variance for installation of sidewalks at a later date on 116th St. was
withdrawn by petitioners at Plan Commission meeting of May 21, 1985.
Developer will install sidewalks per Ordinance requirements.
. Developer will dedicate (record) 45' , one-half of 116th St. right-of-way
of Carmel .
. Show on construction plan separation of utility and drainage easements.
TAC RECOMMENDS APPROVAL OF SECONDARY PLAT PER ABOVE COMMITMENTS
MULTI -TENANT OFFICE BUILDING
10015 N. Meridian Street project, B-5, 1/8 acres, Docket No. 27-85 D.P./A.D.L.S.
Petitioners Present: E. Davis Coots, Leo Stenz, Steve Williams, Greg Jacobi
. Clay sewer district/private well .
. General office, multi-tenant.
. Add inlet and swale at southeast corner of project to drain existing
wet area.
. Straight back concrete curbs around parking lot/used for storm water
detention.
. Off-site drainage to Pennsylvania Rd. via 20' recorded easement to
Pennsylvania Rd.
. Plans show 20' easement on north, south and east property boundaries.
. Need letter from Charles Whitsitt on need for drainage improvement along
frontage road by June 3, 1985.
. Will need letter from Steve Couts, Carmel/Clay Fire Chief.
. Need subsurface drain under parking lot.
. Two to four foot fill in parking lot area.
TECHNICAL ADVISORY COMMITTEE
MINUTES OF MAY 23, 1985
PAGE 3
. Need letter from Kent Ward on final drainage plan to include input from
SCS. Will need revised drainage plan by May 28, 1985.
. Letter from Hamilton County Health Dept.
. Show loading area on plan.
. Show detailed landscape plan for mechanical facilities by June 4, 1985.
TAC APPROVES PROJECT PER ABOVE COMMITMENTS
THE CENTRE
B-3 and B-1 Zone, northwest corner Range Line Rd. and 116th St. , Shopping center,
Docket No. S13-85, Site Development Plan final review.
Petitioners Present: Jim Nelson, Larry Pensinger, Don Gwinnup
. Project is to be phased into two parts per revised plans submitted.
. Phase One - B-3 Zoned District
. Status of existing building.
. Phase Two - B-1 Zoned District and could be built to B-1 Zone standards.
If was developed differently, would need TAC review.
. Site work will be done on entire site.
. Southeast corner of site will need BZA and TAC approval when developed.
. Sanitary sewer will be encased.
TAC APPROVED PLANS AS SUBMITTED
WOODCHASE AT KEYSTONE
Docket Nos . V15-85/S16-85 , Apartment project , Site development plan
final review, 480 units.
Petitioner Present: Stan Neal
. Show perimeter easements, minimum 20' total if drainage ditch, ditch plus
maintenance by May 29, 1985.
. All City departments have expressed concerns concerning the project related
to providing proper city services to a project of this magnitude - fire ,
police, street and engineering. Their comments are on specific letters
from each respective City department head.
. Streets private.
•
'TECHNICAL ADVISORY COMMITTEE �-
MINUTES OF MAY 23, 1985
PAGE 4
. Steve Couts approved fire hydrant location per phone call to Kurt Woerner
and follow-up letter.
. Separate accel/decel lanes with public easements are not proposed for
project on 96th St. Once 96th St. improvements are made, five lanes at
this area, 2 east, 2 west and one in center for left-hand turns. Response
from traffic engineers and Carmel Board of Public Works needed.
. All on-site sewer lines are private or in dedicated easements.
POND PLAN REVIEW
Docket No. S-21-85, private residential pond: Gary Hutton. BZA approval needed per
Special Use, 49. 18 acres at 4509 W. 131st St.
Petitioner Present: Gene Ross
. Closest distance to any property line, 200 feet.
. Minimum depth 4 feet, maximum 10-12 ft.
. Overflow into existing drainage way.
. Property is currently fenced. Will be new fence installed.
TAC APPROVED PLANS AS PRESENTED. . .
•
LAKEVIEW HEALTH CENTER.
Docket No. 23-85 ADLS, 6-2 Zone, 1.3 acres, addition, review of drainage plans,
located at southeast corner of Keystone Ave. and 136th St.
Petitioner Not Present.
. Detention pond proposed.
. Entrance off of frontage road to 136th St.
. Facility is on city sewer.
. Need revised set of plans.
TAC APPROVES TECHNICAL ASPECTS OF PLAN SUBMITTED.