Loading...
HomeMy WebLinkAbout19010027 State Release ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Project numberRelease date CONSTRUCTION DESIGN RELEASE 40376912/19/18 State Form 41191 (R9/5-98) Construction typeOccupancy classification Report Printed on:December 20, 2018 V-A, SPKR-1, A-2, A-3, B, REM Scope of release ARCHELEC Indiana Department of Homeland Security PLUM DIVISION OF FIRE & BUILDING SAFETY Type of release PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Standard Indianapolis, IN 46204 Available At Your Local Licence Branch Project name SUPPORT HOOSIER SAFETY Courtyard by Marriott Indianapolis Carmel To: Owner / Architect / Engineer Baskervill Street address Brent G. Farmer AR11100143 37 W 103rd St 101 South 15th Street Suite 200 CityCounty RichmondVA23219 INDIANAPOLISMARION Fax & e-mail:,bfarmer@baskervill.com The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 14BThis project has been reviewed under the 2014 Indiana Building Code. 4G0412AEThe proposed building, addition, or remodel shall not put the existing building in noncompliance or into further noncompliance in accordance with 675 IAC 12-4-12. 4G0603AFDetailed plans and specifications for the revised fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6- 3(a), 675 IAC 12-6- 7(g)(17), and 675 IAC 13-1-8. (N.F.P.A. 13) 4G0603AK2This release does not include the fire alarm system installation. Plans and specifications for adding or remodeling this system shall be filed as a new project or as a partial before commencing work, in accordance with 675 IAC 12-6-3. 4G0603AMThis release does not include mechanical work. Plans and specifications for adding or remodeling this system shall be filed as a new project or as a partial before commencing work in accordance with 675 IAC 12-6-3. 14B0601VAThe minimum construction type permitted for this building is Type V-A. Building elements shall be protected as specified in Chapters 5, 6, and Table 601, IBC (675 IAC 13-2.6). 14B0700Fire resistive construction shall be maintained in accordance with Chapter 7, IBC (675 IAC 13-2.6). 14B100819Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort in accordance with Section 1008.1.9, IBC (675 IAC 13-2.6). 14B11092Each toilet room and bathing room shall be handicapped accessible in accordance with Section 1109.2, IBC (675 IAC 13-2.6). (Clear turning radius, Door Swing, Grab Bars, Fixture Clearances, Fixture Mounting Heights, Shower/Bathtub seats) 9E11026AAccess and working space shall be provided and maintained about all electric equipment in accordance with Section 110.26, IEC (675 IAC 17-1.8). Page1/2 ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report 9E41036Luminaires shall be installed and supported in accordance with Section 410.36. IEC (675 IAC 17- 1.8). 14W1104ARequired means of egress shall be maintained during construction and demolition, remodeling or alterations and additions to any building, in accordance with Section 1104, IFC (675 IAC 22-2.5). ARELPursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above - stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with its requirements. Code review officialEDWARD HENN Director, Division of Fire and Building Safety ehenn@dhs.in.gov Address (name,title of local official,street,city,state and ZIP code Manager of Bldg Code Analysis Michael Bennett Division of Compliance 1200 Madison Ave Suite 100 Indianapolis,IN46204 Fax & e-mail: 3173278475,planreview.class1@indy.gov Page2/2