Loading...
HomeMy WebLinkAboutGN000.1LOT SPECIFIED PLAN INFORMATION Customer Name {\C256;* Market Home *, 5782-11300#4} Address{\C256;3312 SHELBORNE WOODS PARKWAY}{\Fsimplex|c0;\C256;CARMEL}{\C256;IN}{\C256;46032} Community{\Fsimplex|c0;\C256;5782}{\C256;WOODS AT SHELBORNE}{\C256;5782-11300}{\C256;LOTNUM 123} Plan Features{\C256;Elevation HR3T - IN1} MUNICIPALITY STRUCTURAL ENGINEER APPLICABLE CODES MECHANICAL ENGINEER BUILDING CODE ANALYSIS DESIGN LOADS and CRITERIA AREA CALCULATION (SQ. FT.) \pxt12;{\H0.92593x;BUILDING CODE:\PPLUMBING CODE: \P\pql;MECHANICAL CODE:\PFUEL AND GAS CODE:\P\pq*;ENERGY CODE:\PELECTRICAL CODE:\P\pql;FIRE CODE:\P\pt14;\P\pq*,tz;}1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE REQUIRED DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. VERIFY WITH THE LOCAL BUILDING AGENCIES THE WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. THE ARCHITECT SHALL BE NOTIFIED IN WRITING OF ALL DISCREPANCIES.\P\pa0.25;2. THERE SHALL BE NO STRUCTURAL CHANGES WITHOUT WRITTEN CONSENT OF THE ENGINEER OF RECORD.{\H0.92593x; } ZONING ORDINANCE: .\PUSE GROUP: .\PCONSTRUCTION CLASS: .\PHEIGHT & AREA: .\POTHER REQUIREMENTS: .\pxt20,28;LIVE LOADS:\P\pt2,r28; Sleeping ___ PSF\P Non-Sleeping ___ PSF\P Ext. Decks & Stairs ___ PSF\P\ptr28;DEAD LOAD: ___ PSF\P\pt2,r27; Guard Rail & Handrail ___ LB \P\pt2,r28; Guard Infill Components ___ PSF\P\ptr28;WIND SPEED: ___ MPH\PROOF LIVE LOAD: ___ PSF\PSNOW LOAD: ___ PSF\PLATERAL LOAD: ___ PCF \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} SHEET LIST TABLE SHT DESCRIPTION CC.01 Cover Sheet CC.02 Notes - Schedules and Legends A0.01 Foundation - Basement A1.01 Finished Basement Floor Plan A1.11 1st Floor Plan A1.21 2nd Floor Plan A2.01 Building Section A2.02 Building Section A3.01 Front Elevation A3.02 Left Elevation A3.03 Right Elevation A3.04 Rear Elevation A4.01 Roof Plan U1.11 1st Floor Utility Plan U1.21 2nd Floor Utility Plan U1.01 Finished Basement Utility Plan Structural Plan - Foundation Basement (IN Code) Structural Plan - 1st Floor (IN Code) Structural Plan - 2nd Floor (IN Code)LOT SPECIFIC OPTION SELECTIONSOpt. Additional Cabinets at Pulte Planning CenterBath 7 OptionBedroom 7 OptionOpt. Built in Kitchen 2 Opt. Covered Patio at RearElevation HR3T - IN1Finished Basement OptionDen OptionBasement FoundationTraditional Fireplace at Gathering Room3 Car Side Load GarageMasonry Wrap - Sides and RearOwner's Bath 4IndianaOpt. Tray Ceiling at Dining RoomOpt Tray Ceiling at Owners SuiteOpt. Uncovered Patio at RearOpt Basement Window Well - Location 1Opt Basement Window Well - Location 3 SQUARE FOOTAGE TOTAL:CONDITIONED - LIVABLE SF 1st Floor 2nd Floor Basement - Finished 1896 SF 2094 SF 1239 SF 5229 SF TOTAL:CONDITIONED - NON-LIVABLE SF Basement - Storage & Mech 578 SF 578 SF TOTAL:UNCONDITIONED SF 3 Car Garage Side Covered Porch Front Porch 985 SF 214 SF 180 SF 1379 SF 7186 SF COVER SHEETMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPESingle Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Trailway 2179.300Home for * Market Home *, 5782-11300#43312 Shelborne Woods Parkway, Carmel, IN 46032CC.01 01/18/19 Mike Sheeks