HomeMy WebLinkAbout114 Woods at Shelborne LAYOUTGE01
T01
T01
T02
T02 MG01M01M01M01M01M01M01M01M01GE02T03T03T03GE03M02M02M02M02M02M02M02M02M02MG02TG01GE04 T04T04T04T05T06T06T06T06T06T06T06T04T04T04T04T07T07GE12GE05T08T08T08T08T08GE06 T09T03GE07M03M03M03M03M04GE11T10T11GE08
T12
T12
GE09
T13
T13
J01M05
M06
M06
M06
M06
M06
M06
M06
M06
M06
M06
TG02
TG03J02 GE10
T14
T14
T15
V01
V02
V03
V04
V05
V06
V07
V08
V098-00-00 15-00-00 30-00-00
1-00-0016-08-00 14-06-00 12-08-00 2-02-00 53-00-00
29-04-001-00-00 57-00-00 58-00-005-03-08 4-08-08 1-00-00 20-00-00 10-06-00 11-02-00 11-04-00
53-00-00 10-00-00 57-00-0030-08-0822-00-00 6-00-009-00-0014-03-08 3-00-0016-03-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00 2-00-002-00-002-00-002-00-002-00-002-00-002-00-001-00-12 1-02-04 2-01-082-01-082-01-082-01-082-01-082-01-082-01-082-01-082-01-082-01-082-01-082-01-082-01-082-01-082-00-002-00-002-00-002-00-001-07-002-00-002-00-002-00-002-00-001-04-002-00-002-00-002-00-002-00-002-00-002-00-00
2-00-00
2-00-00
2-00-00
1-07-08
1-10-00
1-05-08
2-00-00
1-10-04
1-10-04
2-00-00
1-09-082-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
1-11-08
2-00-00
2-00-00 2-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-00A- H2.5A A - LTHJR B- HGUS26-2 B - LUS24 C- HGUS26-2-2 C - LUS26-2 D- HGUS28-2 D - LUS410 E- HTU26 E - MUS26 F -LTHJL F -THA422-2 PULTE HOMES114 Woods at Shelborne - Truman - CR2GHANGER SCHEDULE QTY DESCRIPTION SYM QTY DESCRIPTION ROOF LOADINGTCLL 25 PSFTCLS 0 PSFTCLD 10 PSFBCLL 10 PSFBCLD 10 PSFWIND SPEED 90 MPHCODE: IRC 2006Address: Salesperson:Scale: Quote Number:B18803780 Drawn by: Katherine SelvaDate: 12/26/2018 Lot Number:114 Designed by: Katherine SelvaTRUSS PLACEMENT GUIDE
CUSTOMER:JOB NAME & MODEL:NOTES:
DO NOT CUT OR MODIFY TRUSSES.
TRUSSES ARE SPACED 24" ON CENTER UNLESS NOTED OTHERWISE.
REFER TO THE INDIVIDUAL TRUSS DESIGN DRAWINGS FOR THE LOCATION OF
LATERAL BRACING AND MULTY-PLY CONNECTION REQUIREMENTS.
PER ANSI TPI 1-2002 THE TRUSS ENGINEER IS RESPONSIBLE FOR TRUSS TO TRUSS
CONECTIONS AND TRUSS PLY TO PLY CONNECTIONS. THIS PLACEMENT PLAN
RECOMMENDS TRUSS TO BEARING CONNECTIONS AND TRUSS TO BEAM
CONNECTIONS WHICH SHALL BE REVIEWED BY THE BUILDING DESIGNER TO
RESOLVE ALL ROOF FORCES ADEQUATELY TO THE FOUNDATION.
ALL TRUSS TIES TO BE INSTALLED BEFORE
O.S.B. IS APPLIED TO ROOF
DO NOT CUT TRUSSES! TRUSSES CUT BY ANY TRADE / SUB-CONTRACTOR WITHOUT FIRST RECEIVING PERMISSIONAND DIRECTION FROMPROBuild, (317) 834 5380, SHALL BE CONTRACTOR / BUILDER RESPONSIBILITY! NO EXCEPTIONS3D VIEW 1
3D VIEW 2
01/18/19
Mike Sheeks