HomeMy WebLinkAboutA000.75:12CR2GROOF AREA "A"SQ FTG2120AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY2.833.533.3947.9480AT EAVE4.243.533.6852.06053.00TOTAL (MIN)7.077.077.07100.003 HIGH -RIDGE VENT2.833.533.5048.740028.00AT EAVE4.243.533.6851.26053.00TOTAL (MIN)7.077.077.18100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLECR2GROOF AREA "B"SQ FTG276AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.370.460.4243.2610AT EAVE0.550.460.5656.7408.00TOTAL (MIN)0.920.920.98100.003 HIGH -RIDGE VENT0.370.460.5047.37004.00AT EAVE0.550.460.5652.6308.00TOTAL (MIN)0.920.921.06100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLECR2GROOF AREA "C"SQ FTG144AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.190.240.4246.5610AT EAVE0.290.240.4953.4407.00TOTAL (MIN)0.480.480.91100.003 HIGH -RIDGE VENT0.190.240.3843.55003.00AT EAVE0.290.240.4956.4507.00TOTAL (MIN)0.480.480.86100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE6:12 5:12 5:126:12 5:12 5:125:12 5:12 4.5:12 6:12 4:124:12 4:12 4.5:12 4:12"A" 2120ROOF AREA: SQ. FT. PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION MIN. 131 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "E" "B" 276ROOF AREA: SQ. FT.6:12 MIN. 155 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D" "C" 144ROOF AREA: SQ. FT. 4:12 4:12 4:12 MIN. 208 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF \A1;1'-0"\PTYP. \A1;28'-0" \A1;4'-0"\A1;3'-0" \A1;1'-0"\A1;2'-11" \A1;4'-10{\H0.750000x;\S1#2;}" \A1;1'-0"\A1;21'-0" 8:12 A4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPESingle Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Truman 1702.300Home for * Market Home *, 5782-114003316 Shelborne Woods Parkway, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) 01/18/19 Mike Sheeks