HomeMy WebLinkAboutALB 21 - A010.0Re:
The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision
based on the parameters provided by 84 Components - 0783.
Liu, Xuegang
Pages or sheets covered by this seal: I31886171 thru I31886211
My license renewal date for the state of Indiana is July 31, 2018.
1701490
Truss Engineer’s responsibility is solely for
design of individual trusses based upon design parameters shown
on referenced truss drawings. Parameters have not been verified
as appropriate for any use. Any location identification specified is
for file reference only and has not been used in preparing design.
Suitability of truss designs for any particular building is the
responsibility of the building designer, not the Truss Engineer,
per ANSI/TPI-1, Chapter 2.
IMPORTANT NOTE:
WIN20
16023 Swingley Ridge Rd
Chesterfield, MO 63017
314-434-1200
MiTek USA, Inc.
December 12,2017
Job
1701490
Truss
G1
Truss Type
Common Girder
Qty
1
Ply
2
WIN20
Job Reference (optional)
I31886171
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:17 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-cclDm7Ecgbg3nm4Iqy9Sfhlc5yrAbEznqeSFRdy9lNi
Scale = 1:31.5
1
2
3
4
5
6
7
10 9 819202122 23
6x10
4x4
4x6
6x10
4x4
8x8
4x6
2x4
4x6
3x6
3-6-8
3-6-8
6-9-8
3-3-0
10-0-8
3-3-0
13-7-0
3-6-8
3-6-8
3-6-8
6-9-8
3-3-0
10-0-8
3-3-0
13-7-0
3-6-8
0-11-125-6-10-11-128.00 12
Plate Offsets (X,Y)-- [9:0-4-0,0-4-12], [10:0-4-4,0-1-8]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.53
0.86
0.97
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.14
0.04
(loc)
9-10
9-10
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 140 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud
SLIDER Left 2x6 SPF No.2 2-0-0, Right 2x6 SPF No.2 1-6-0
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-6-12 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=5172/0-3-8 (req. 0-4-1), 7=5451/0-3-8 (req. 0-4-4)
Max Horz 1=88(LC 24)
Max Uplift 1=-316(LC 10), 7=-331(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-3=-5728/411, 3-4=-4377/349, 4-5=-4377/350, 5-7=-5589/400
BOT CHORD 1-10=-314/4636, 9-10=-314/4636, 8-9=-284/4536, 7-8=-284/4536
WEBS 4-9=-310/4497, 5-9=-1204/150, 5-8=-80/1478, 3-9=-1339/158, 3-10=-87/1701
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) WARNING: Required bearing size at joint(s) 1, 7 greater than input bearing size.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=316, 7=331.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1362 lb down and 92 lb up at
1-0-4, 1362 lb down and 92 lb up at 3-0-4, 1362 lb down and 92 lb up at 5-0-4, 1362 lb down and 92 lb up at 7-0-4, 1362 lb down
and 92 lb up at 9-0-4, and 1362 lb down and 92 lb up at 11-0-4, and 1366 lb down and 87 lb up at 13-0-4 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
G1
Truss Type
Common Girder
Qty
1
Ply
2
WIN20
Job Reference (optional)
I31886171
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:17 2017 Page 2 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-cclDm7Ecgbg3nm4Iqy9Sfhlc5yrAbEznqeSFRdy9lNi
LOAD CASE(S) Standard
Uniform Loads (plf)
Vert: 1-4=-60, 4-7=-60, 11-15=-20
Concentrated Loads (lb)
Vert: 9=-1362(B) 17=-1366(B) 19=-1362(B) 20=-1362(B) 21=-1362(B) 22=-1362(B) 23=-1362(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
1701490
Truss
M1
Truss Type
Monopitch
Qty
3
Ply
1
WIN20
Job Reference (optional)
I31886172
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:18 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-4pJb_TEERvowOweUOfghBvHpdLKyKufw2ICoz4y9lNh
Scale = 1:53.5
1
2
3
6 5 4
7 8
9
5x6
4x6 3x4 4x4
4x6
4x4
3x6
6-6-0
6-6-0
13-0-0
6-6-0
6-6-0
6-6-0
13-0-0
6-6-0
1-11-1210-7-129-1-1210-7-128.00 12
Plate Offsets (X,Y)-- [1:0-1-4,0-1-12]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.41
0.31
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.03
-0.09
-0.12
(loc)
5-6
4-5
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 70 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
3-4,2-4: 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied.
WEBS 1 Row at midpt 2-4
REACTIONS.(lb/size)6=508/0-3-8, 8=485/0-3-8
Max Horz 6=281(LC 7)
Max Uplift 8=-128(LC 10)
Max Grav 6=508(LC 1), 8=564(LC 18)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-517/60, 4-7=-70/428, 3-7=-70/428, 1-6=-455/69
BOT CHORD 5-6=-267/232, 4-5=-111/407
WEBS 2-4=-505/157, 1-5=-5/324, 3-8=-586/149
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
5) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
8=128.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
M1G
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886173
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:20 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-1BRMO9GUyW2eeEotV4j9HKM9690Qoo9DWchv1yy9lNf
Scale = 1:53.6Sheet Front
Full Sheathing
1 Ply 7/16" 4X8 OSB
1
2
3
6 5 4
26 27
28
5x6
4x6 3x4 4x4
4x6
4x4
3x6
6-6-0
6-6-0
13-0-0
6-6-0
6-6-0
6-6-0
13-0-0
6-6-0
1-11-1210-7-129-1-1210-7-128.00 12
Plate Offsets (X,Y)-- [1:0-1-4,0-1-12]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.41
0.31
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.03
-0.09
-0.12
(loc)
5-6
4-5
27
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 338 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
3-4,2-4: 2x4 SPF No.2
OTHERS 2x4 SPF Stud *Except*
3-26,7-8: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied.
WEBS 1 Row at midpt 2-4
REACTIONS.(lb/size)6=508/0-3-8, 27=485/0-3-8
Max Horz 6=281(LC 7)
Max Uplift 27=-128(LC 10)
Max Grav 6=508(LC 1), 27=564(LC 18)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-517/60, 4-26=-70/428, 3-26=-70/428, 1-6=-455/69
BOT CHORD 5-6=-267/232, 4-5=-111/407
WEBS 2-4=-505/157, 1-5=-5/324, 3-27=-586/149
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) Bearing at joint(s) 27 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
27=128.
10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
M2
Truss Type
Monopitch
Qty
4
Ply
1
WIN20
Job Reference (optional)
I31886174
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:21 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-VO?kcVH6jqAVFON33nEOpXvLeZMrXH4MlGQTaOy9lNe
Scale = 1:14.0
1
2
3
4
8
1.5x4
1.5x4
3x4
5-8-4
5-8-4
-0-10-8
0-10-8
5-8-4
5-8-4
0-3-122-2-84.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.36
0.30
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.04
-0.12
0.00
(loc)
4-7
4-7
2
l/defl
>999
>549
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied.
REACTIONS.(lb/size)4=218/Mechanical, 2=278/0-3-8
Max Horz 2=66(LC 11)
Max Uplift 4=-31(LC 12), 2=-53(LC 8)
Max Grav 4=233(LC 19), 2=282(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2.
9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
M3
Truss Type
Monopitch
Qty
7
Ply
1
WIN20
Job Reference (optional)
I31886175
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:22 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-zaY6prIkU7IMtYyFdVldMlSXVzifGkJWzwA06ry9lNd
Scale: 1"=1’
1
2
3
4
8
1.5x4
1.5x4
3x4
4-8-4
4-8-4
-0-10-8
0-10-8
4-8-4
4-8-4
0-3-121-10-84.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.23
0.20
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.02
-0.05
0.00
(loc)
4-7
4-7
2
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 14 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied.
REACTIONS.(lb/size)4=177/Mechanical, 2=239/0-3-8
Max Horz 2=55(LC 11)
Max Uplift 4=-25(LC 12), 2=-50(LC 8)
Max Grav 4=186(LC 19), 2=241(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2.
9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
M4
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886176
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:23 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-Rm6U1BIMFRQDVhXSACGsuy_jLM4G?BjfCavZeHy9lNc
Scale = 1:17.4
Sheet Front
Full Sheathing
1 Ply 7/16" 4X8 OSB
1
2
3
4
5
6
10 9 8 7
11
2x4
-0-10-8
0-10-8
8-0-0
8-0-0
0-3-122-11-124.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.16
0.11
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.01
-0.00
(loc)
1
1
7
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 65 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 8-0-0.
(lb) - Max Horz 2=91(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 7, 2, 8, 9, 10
Max Grav All reactions 250 lb or less at joint(s) 7, 2, 8, 9 except 10=333(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) All plates are 1.5x4 MT20 unless otherwise indicated.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 2, 8, 9, 10.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
M5
Truss Type
Monopitch
Qty
6
Ply
1
WIN20
Job Reference (optional)
I31886177
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:24 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-vzgtEXJ?0lY46r6ekwn5RAXkKmIukeppREf7Bjy9lNb
Scale = 1:17.4
1
2
3
4
8
4x4
1.5x4
4x4
-0-10-8
0-10-8
8-0-0
8-0-0
0-3-122-11-122-7-92-11-124.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.78
0.59
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.17
-0.47
0.00
(loc)
4-7
4-7
2
l/defl
>569
>200
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 23 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied.
REACTIONS.(lb/size)3=311/Mechanical, 2=370/0-3-8
Max Horz 2=91(LC 11)
Max Uplift 3=-44(LC 12), 2=-62(LC 8)
Max Grav 3=345(LC 19), 2=378(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2.
9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
10) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
M6
Truss Type
Monopitch
Qty
12
Ply
1
WIN20
Job Reference (optional)
I31886178
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:24 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-vzgtEXJ?0lY46r6ekwn5RAXlGmKDkeppREf7Bjy9lNb
Scale = 1:17.4
1
2
3
4
10
1.5x4
1.5x4 4x4
0-4-0
0-4-0
8-0-0
7-8-0
-0-10-8
0-10-8
8-0-0
8-0-0
0-3-122-11-124.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.72
0.51
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.38
0.00
(loc)
4-9
4-9
2
l/defl
>753
>248
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 23 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied.
REACTIONS.(lb/size)4=295/Mechanical, 2=386/0-3-8
Max Horz 2=91(LC 11)
Max Uplift 4=-42(LC 12), 2=-65(LC 8)
Max Grav 4=328(LC 19), 2=394(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2.
9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
M6G
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886179
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:25 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-N9EFSsKdn2gwk?hqIdIK_N4w0AgST53yfuOgjAy9lNa
Scale = 1:17.4
Sheet Back
Full Sheathing
1 Ply 7/16" 4X8 OSB
1
2
3
4
16
4x4
0-4-0
0-4-0
8-0-0
7-8-0
-0-10-8
0-10-8
8-0-0
8-0-0
0-3-122-11-124.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.72
0.51
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.38
0.00
(loc)
4-15
4-15
2
l/defl
>753
>248
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 65 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied.
REACTIONS.(lb/size)4=295/Mechanical, 2=386/0-3-8
Max Horz 2=91(LC 11)
Max Uplift 4=-42(LC 12), 2=-65(LC 8)
Max Grav 4=328(LC 19), 2=394(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) All plates are 1.5x4 MT20 unless otherwise indicated.
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Refer to girder(s) for truss to truss connections.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2.
12) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
PB1
Truss Type
Piggyback
Qty
18
Ply
1
WIN20
Job Reference (optional)
I31886180
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:25 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-N9EFSsKdn2gwk?hqIdIK_N42?AmbT5OyfuOgjAy9lNa
Scale = 1:17.2
1
2
3
4 5
6
4x4
2x4 2x4 1.5x4
8-10-12
8-10-12
4-5-6
4-5-6
8-10-12
4-5-6
0-4-72-11-90-1-80-4-70-1-88.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.21
0.12
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
0.00
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 23 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)2=192/7-4-14, 4=192/7-4-14, 6=266/7-4-14
Max Horz 2=-54(LC 8)
Max Uplift 2=-36(LC 10), 4=-44(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T1
Truss Type
Common
Qty
3
Ply
1
WIN20
Job Reference (optional)
I31886181
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:26 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-rLodfCLFYMpnM9G0sLqZWbcAQa3ECXs5uY8EFcy9lNZ
Scale = 1:35.5
1
2
3
4
7 6 5
3x4 3x4 4x8
4x6
4x4 4x4
6-6-0
6-6-0
13-0-0
6-6-0
6-6-0
6-6-0
13-0-0
6-6-0
14-4-8
1-4-8
1-11-126-3-121-11-128.00 12
Plate Offsets (X,Y)-- [1:Edge,0-1-12], [3:0-1-0,0-1-12]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.42
0.28
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.03
-0.08
0.00
(loc)
6-7
5-6
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 59 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied.
REACTIONS.(lb/size)7=503/0-3-8, 5=605/0-3-8
Max Horz 7=-145(LC 6)
Max Uplift 7=-29(LC 10), 5=-54(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-466/92, 2-3=-471/95, 1-7=-443/93, 3-5=-545/146
WEBS 3-6=-26/261
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T1GE
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886182
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:34 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-cuHeKxRGfppfJOtZK0zRrHybQorC49eHkn4fX8y9lNR
Scale = 1:37.9
Sheet Front
Full Sheathing
1 Ply 7/16" 4X8 OSB
1
2
3
4
5
6
7
8
9
10
11
12
23 22 21 20 19 18 17 16 15 14 13
2x4
2x4
4x4
2x4
2x4
13-0-0
13-0-0
6-6-0
6-6-0
13-0-0
6-6-0
14-4-8
1-4-8
1-11-126-3-121-11-128.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-R
0.23
0.08
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.00
-0.00
(loc)
12
11
13
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 228 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 13-0-0.
(lb) - Max Horz 23=-145(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 19, 20, 21, 17, 16, 15 except 23=-136(LC 6), 13=-125(LC 7),
22=-123(LC 7), 14=-141(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 23, 18, 19, 20, 21, 22, 17, 16, 15, 14 except 13=271(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 11-13=-258/126
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 20, 21, 17,
16, 15 except (jt=lb) 23=136, 13=125, 22=123, 14=141.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T2
Truss Type
Common
Qty
3
Ply
1
WIN20
Job Reference (optional)
I31886183
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:35 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-54r1YHSuQ7xWxXSltkUgOUUiBC4GpcsQzRpC3ay9lNQ
Scale = 1:42.3
1
2
3
4
5
6
7
8
9
12 11 102122
4x6
5x10
4x4
3x6 4x4
1.5x4
4x4
1.5x4
5x10
4x4
7-3-8
7-3-8
14-3-8
7-0-0
21-7-0
7-3-8
-1-4-8
1-4-8
5-6-8
5-6-8
10-9-8
5-3-0
16-0-8
5-3-0
21-7-0
5-6-8
22-11-8
1-4-8
0-11-128-2-10-11-128.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.49
0.48
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.15
-0.27
0.06
(loc)
10-12
10-12
8
l/defl
>999
>945
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 93 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
6-10,4-12: 2x4 SPF Stud
SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0
BRACING-
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied.
REACTIONS.(lb/size)2=946/0-3-8, 8=946/0-3-8
Max Horz 2=-157(LC 8)
Max Uplift 2=-77(LC 10), 8=-77(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1080/142, 4-5=-968/195, 5-6=-968/195, 6-8=-1080/142
BOT CHORD 2-12=-89/902, 10-12=0/639, 8-10=-12/819
WEBS 5-10=-83/433, 5-12=-83/432
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T2GE
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886184
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:36 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-ZGPPldSWBR3NZh1xRR?vwi1xwcXLY1MaB5Zlc1y9lNP
Scale = 1:43.6Sheet Front
Full Sheathing
1 Ply 7/16" 4X8 OSB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
2x4
4x4
3x6
5x9
5x6
21-7-0
21-7-0
-1-4-8
1-4-8
10-9-8
10-9-8
21-7-0
10-9-8
22-11-8
1-4-8
0-11-128-2-10-11-128.00 12
Plate Offsets (X,Y)-- [17:0-2-2,0-2-4], [18:Edge,0-3-14], [31:0-1-12,0-1-8]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.23
0.04
0.16
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
0.00
(loc)
19
19
18
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 412 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud *Except*
10-27: 2x4 SPF No.2
SLIDER Right 2x6 SPF No.2 1-9-3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 21-7-0.
(lb) - Max Horz 36=-170(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) 36, 28, 29, 30, 32, 33, 34, 35, 18,
26, 25, 24, 23, 22, 21, 20
Max Grav All reactions 250 lb or less at joint(s) 36, 27, 28, 29, 30, 32, 33, 34,
35, 18, 26, 25, 24, 23, 22, 21, 20
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 36, 28, 29, 30,
32, 33, 34, 35, 18, 26, 25, 24, 23, 22, 21, 20.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T3
Truss Type
Common
Qty
5
Ply
1
WIN20
Job Reference (optional)
I31886185
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:36 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-ZGPPldSWBR3NZh1xRR?vwi1xIcRfY28aB5Zlc1y9lNP
Scale = 1:39.9
1
2
3
4
5
6 7
10 9 817
3x6 4x4
1.5x4
4x6
4x4
1.5x4
4x8 4x8
7-0-13
7-0-13
13-10-3
6-9-5
20-11-0
7-0-13
-0-10-8
0-10-8
5-4-8
5-4-8
10-5-8
5-1-0
15-6-8
5-1-0
20-11-0
5-4-8
21-9-8
0-10-8
0-7-127-7-70-7-128.00 12
Plate Offsets (X,Y)-- [2:0-2-2,0-3-7], [2:0-3-8,Edge], [6:0-2-2,0-3-7], [6:0-3-8,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.21
0.41
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.10
-0.19
0.03
(loc)
8-10
8-10
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 83 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
3-10,5-8: 2x4 SPF Stud
WEDGE
Left: 2x4 SPF Stud, Right: 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied.
REACTIONS.(lb/size)2=889/0-3-8, 6=889/0-3-8
Max Horz 2=-146(LC 8)
Max Uplift 2=-68(LC 10), 6=-68(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1138/145, 3-4=-1017/193, 4-5=-1017/193, 5-6=-1138/145
BOT CHORD 2-10=-93/946, 8-10=0/638, 6-8=-33/879
WEBS 3-10=-264/164, 4-10=-79/472, 4-8=-79/473, 5-8=-264/164
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T3GE
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886186
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:37 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-1TynzzT8ykBEArb8?8W8Tva8i0tgHVOjQlJJ8Ty9lNO
Scale = 1:40.2Sheet Front
Full Sheathing
1 Ply 7/16" 4X8 OSB
1 2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
30 29 28 27 26 25 24 23 22 21 20 19 18
4x4
3x6
5x6
5x9
20-11-0
20-11-0
-0-10-8
0-10-8
10-5-8
10-5-8
20-11-0
10-5-8
21-9-8
0-10-8
0-7-127-7-70-7-128.00 12
Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-1-12,0-3-8], [16:0-3-8,0-1-8], [28:0-3-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.10
0.04
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
16
16
16
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 366 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
16-28: 2x4 SP DSS
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
WEDGE
Left: 2x6 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 20-11-0.
(lb) - Max Horz 2=-148(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) 16, 25, 26, 27, 28, 29, 30, 23, 2,
22, 21, 20, 19, 18
Max Grav All reactions 250 lb or less at joint(s) 16, 24, 25, 26, 27, 28, 29, 30,
23, 2, 22, 21, 20, 19, 18
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Solid blocking is required on both sides of the truss at joint(s), 16.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 25, 26, 27,
28, 29, 30, 23, 2, 22, 21, 20, 19, 18.
12) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T4
Truss Type
Common
Qty
6
Ply
1
WIN20
Job Reference (optional)
I31886187
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:38 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-VfW9AJUnj2J4o?AKZs1N?66AJP3U0tCtfP2sgvy9lNN
Scale = 1:66.1
1
2
3
4
5
6
7 8
12 11 10 9171819 20
4x4
4x6
3x6
3x8 MT18HS
4x8
4x4
4x6
1.5x4 5x12 MT20HS 5x10
4x4
11-3-0
11-3-0
19-0-0
7-9-0
27-0-8
8-0-8
5-9-4
5-9-4
11-3-0
5-5-12
19-0-0
7-9-0
27-0-8
8-0-8
28-5-0
1-4-8
4-0-111-6-10-11-128.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.62
0.70
0.39
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.47
-0.91
0.07
(loc)
11-12
11-12
7
l/defl
>692
>354
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
MT18HS
Weight: 127 lb FT = 20%
GRIP
197/144
148/108
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
10-12: 2x4 SPF 2100F 1.8E
WEBS 2x4 SPF No.2 *Except*
5-9: 2x4 SPF Stud
SLIDER Right 2x6 SPF No.2 1-6-0
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied.
WEBS 1 Row at midpt 5-11, 2-12
REACTIONS.(lb/size)12=1074/0-3-8, 7=1160/0-3-8
Max Horz 12=-261(LC 8)
Max Uplift 12=-52(LC 10), 7=-96(LC 11)
Max Grav 12=1133(LC 19), 7=1225(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-933/212, 3-5=-973/199, 5-7=-1479/177
BOT CHORD 11-12=-40/779, 9-11=-16/1141, 7-9=-16/1141
WEBS 3-11=-87/611, 5-11=-637/207, 5-9=0/293, 2-12=-979/82
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 7.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T4GE
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886188
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:39 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-zr4XOfVPUMRxQ9lW6ZYcYKfR9pZGlQd0t3oQCMy9lNM
Scale = 1:32.9
Sheet Front
Full Sheathing
1 Ply 7/16" 4X8 OSB
1
2
3
4
5
6
7
8
9
10
11
12
13
23 22 21 20 19 18 17 16 15 14
2x4
4x4
5x9
5x6
13-7-0
13-7-0
-1-4-8
1-4-8
6-9-8
6-9-8
13-7-0
6-9-8
14-11-8
1-4-8
0-11-125-6-10-11-128.00 12
Plate Offsets (X,Y)-- [11:0-2-2,0-2-4], [12:Edge,0-3-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.23
0.03
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
0.00
(loc)
13
13
12
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 196 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
SLIDER Right 2x6 SPF No.2 1-9-3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 13-7-0.
(lb) - Max Horz 23=-118(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) 23, 12, 19, 20, 21, 22, 17, 16, 15, 14
Max Grav All reactions 250 lb or less at joint(s) 23, 12, 18, 19, 20, 21, 22, 17, 16, 15, 14
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 12, 19, 20,
21, 22, 17, 16, 15, 14.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T5
Truss Type
Roof Special
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886189
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:40 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-R2ewb?W1FfZo1JKjgH4r4XBQWDhNUjM96jXzloy9lNL
Scale = 1:73.1
1
2
3
4
5
6
7
89
15 14 13 12 11 102021 22
3x4
4x8 5x6
4x6
3x6
3x8 MT18HS6x10
4x6
4x8
4x6
1.5x4 6x10
4x6
3x8 MT18HS
7-9-6
7-9-6
18-9-8
11-0-2
26-6-8
7-9-0
34-7-0
8-0-8
7-9-6
7-9-6
13-3-7
5-6-1
18-9-8
5-6-1
26-6-8
7-9-0
34-7-0
8-0-8
35-11-8
1-4-8
4-2-011-6-10-11-124-2-08.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.96
0.93
0.67
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.54
-1.11
0.13
(loc)
12-14
12-14
8
l/defl
>767
>372
n/a
L/d
240
180
n/a
PLATES
MT20
MT18HS
Weight: 158 lb FT = 20%
GRIP
197/144
197/144
LUMBER-
TOP CHORD 2x4 SPF 1650F 1.5E *Except*
2-4,4-5: 2x4 SPF No.2
BOT CHORD 2x4 SPF 1650F 1.5E *Except*
8-11: 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
1-15,2-14,6-10: 2x4 SPF Stud
SLIDER Right 2x6 SPF No.2 1-9-0
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals, and
2-0-0 oc purlins (3-1-9 max.): 1-2.
BOT CHORD Rigid ceiling directly applied.
WEBS 1 Row at midpt 3-12, 6-12
REACTIONS.(lb/size)15=1376/0-3-8, 8=1462/0-3-8
Max Horz 15=-262(LC 8)
Max Uplift 15=-107(LC 10), 8=-104(LC 11)
Max Grav 15=1376(LC 1), 8=1526(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-15=-1306/191, 1-2=-2260/274, 2-3=-2707/387, 3-4=-1441/269, 4-6=-1461/256,
6-8=-1957/228
BOT CHORD 12-14=-88/1608, 10-12=-58/1517, 8-10=-58/1517
WEBS 1-14=-238/2469, 2-14=-1825/349, 3-14=-144/1188, 3-12=-709/202, 4-12=-148/1151,
6-12=-592/204, 6-10=0/285
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) Provide adequate drainage to prevent water ponding.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
15=107, 8=104.
9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T5GE
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886190
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:42 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-NQmg0hXHnGqWHcU5oi6JAyHzL1aSyl9Sa104phy9lNJ
Scale = 1:59.6Sheet Back
Full Sheathing
1 Ply 7/16" 4X8 OSB
1
2 3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23 24
44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25
4x6
4x4
4x6
5x6
5x9
5x6
27-0-8
27-0-8
11-3-0
11-3-0
27-0-8
15-9-8
28-5-0
1-4-8
4-0-111-6-10-11-128.00 12
Plate Offsets (X,Y)-- [20:0-0-0,0-1-12], [20:0-2-4,0-2-4], [21:0-2-2,0-0-0], [22:0-2-2,0-2-4], [23:Edge,0-3-14], [36:0-3-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.17
0.06
0.14
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
0.01
(loc)
24
23
23
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 744 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud *Except*
10-36,9-37,8-38,7-39,6-40,11-35,12-34,13-33,14-32: 2x4 SPF No.2
SLIDER Right 2x6 SPF No.2 1-4-6
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 10-36, 9-37, 8-38, 7-39, 11-35, 12-34,
13-33
REACTIONS.All bearings 27-0-8.
(lb) - Max Horz 44=-258(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) 44, 36, 37, 38, 39, 40, 41, 42, 43,
35, 34, 33, 32, 31, 30, 29, 28, 27, 26 except 23=-197(LC 7), 25=-122(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 44, 36, 37, 38, 39, 40, 41, 42,
43, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25 except 23=305(LC 18)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 8-9=-232/266, 9-10=-238/276, 10-11=-236/272, 11-12=-229/263, 22-23=-333/280
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 1-4-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 44, 36, 37, 38,
39, 40, 41, 42, 43, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26 except (jt=lb) 23=197, 25=122.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T6
Truss Type
Roof Special
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886191
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:43 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-scK2D0YvYayNum3ILPdYiAp?vQiDh1ycohmdL7y9lNI
Scale = 1:65.7
1
2
3
4
5
6
7
8
9 10
16 15 14 13 12 112122232425 26
4x6
3x4 5x6
4x6
3x6
3x6
4x6
5x9
4x6
4x8
4x6
1.5x4 6x10
4x6
3x6
9-9-6
9-9-6
18-9-8
9-0-2
26-6-8
7-9-0
34-7-0
8-0-8
5-0-7
5-0-7
9-9-6
4-8-15
14-3-7
4-6-1
18-9-8
4-6-1
26-6-8
7-9-0
34-7-0
8-0-8
35-11-8
1-4-8
5-6-011-6-10-11-125-6-08.00 12
Plate Offsets (X,Y)-- [3:0-3-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.76
0.92
0.87
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.27
-0.65
0.15
(loc)
13-15
15-16
9
l/defl
>999
>637
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 167 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
6-10: 2x4 SPF 1650F 1.5E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud *Except*
4-15,4-13,5-13,7-13: 2x4 SPF No.2
SLIDER Right 2x6 SPF No.2 1-9-0
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals, and
2-0-0 oc purlins (4-0-9 max.): 1-3.
BOT CHORD Rigid ceiling directly applied.
WEBS 1 Row at midpt 2-16, 4-13, 7-13
REACTIONS.(lb/size)16=1376/0-3-8, 9=1462/0-3-8
Max Horz 16=-276(LC 8)
Max Uplift 16=-114(LC 10), 9=-103(LC 11)
Max Grav 16=1384(LC 2), 9=1531(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1955/257, 3-4=-2350/356, 4-5=-1413/279, 5-7=-1446/261, 7-9=-1971/227
BOT CHORD 15-16=-71/1180, 13-15=-44/1509, 11-13=-57/1520, 9-11=-57/1520
WEBS 2-16=-1589/224, 2-15=-66/1239, 3-15=-1469/283, 4-15=-129/1013, 4-13=-707/185,
5-13=-165/1160, 7-13=-612/199, 7-11=0/314
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
16=114, 9=103.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T7
Truss Type
Roof Special
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886192
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:43 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-scK2D0YvYayNum3ILPdYiAp?oQiYh8ScohmdL7y9lNI
Scale = 1:62.4
1 2
3
4
5
6
7
8 9
16 15 14 13 12 11 1021222324 25
3x4
5x6 4x8
4x6
3x6
3x6 5x9
1.5x4
1.5x4 4x8
4x6
1.5x4 6x10
4x6
3x6
6-0-7
6-0-7
11-9-6
5-8-15
18-9-8
7-0-2
26-6-8
7-9-0
34-7-0
8-0-8
6-0-7
6-0-7
11-9-6
5-8-15
18-9-8
7-0-2
26-6-8
7-9-0
34-7-0
8-0-8
35-11-8
1-4-8
6-10-011-6-10-11-126-10-08.00 12
Plate Offsets (X,Y)-- [3:0-2-12,0-2-4]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.77
0.90
0.39
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.15
-0.40
0.15
(loc)
10-12
10-12
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 170 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
5-9: 2x4 SPF 1650F 1.5E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
1-16,2-15,3-14,6-10: 2x4 SPF Stud
SLIDER Right 2x6 SPF No.2 1-9-0
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals, and
2-0-0 oc purlins (5-2-12 max.): 1-3.
BOT CHORD Rigid ceiling directly applied.
WEBS 1 Row at midpt 1-16, 3-15, 3-12, 6-12
REACTIONS.(lb/size)16=1376/0-3-8, 8=1462/0-3-8
Max Horz 16=-289(LC 8)
Max Uplift 16=-124(LC 10), 8=-103(LC 11)
Max Grav 16=1420(LC 2), 8=1525(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-16=-1320/204, 1-2=-1078/204, 2-3=-1078/204, 3-4=-1442/262, 4-6=-1428/263,
6-8=-1965/227
BOT CHORD 14-15=-63/1723, 12-14=-61/1728, 10-12=-56/1514, 8-10=-56/1514
WEBS 1-15=-183/1584, 2-15=-398/164, 3-15=-980/101, 3-14=0/299, 3-12=-832/175,
4-12=-125/1086, 6-12=-620/196, 6-10=0/334
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
16=124, 8=103.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T8
Truss Type
Roof Special
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886193
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:44 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-KpuQRMZXJu4EWweUv68nFNM9Fq2WQZgl1LVAuZy9lNH
Scale = 1:65.1
1 2
3
4
5
6
7
8 9
16 15 14 13 12 11 1021222324 25
3x4
5x6 4x8
4x6
3x6
3x6 5x9
1.5x4
1.5x4 4x8
4x6
1.5x4 6x10
4x6
3x6
7-0-7
7-0-7
13-9-6
6-8-15
18-9-8
5-0-2
26-6-8
7-9-0
34-7-0
8-0-8
7-0-7
7-0-7
13-9-6
6-8-15
18-9-8
5-0-2
26-6-8
7-9-0
34-7-0
8-0-8
35-11-8
1-4-8
8-2-011-6-10-11-128-2-08.00 12
Plate Offsets (X,Y)-- [3:0-2-12,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.79
0.92
0.52
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.16
-0.42
0.14
(loc)
10-12
10-12
8
l/defl
>999
>973
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 178 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
5-9: 2x4 SPF 1650F 1.5E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
6-10: 2x4 SPF Stud
SLIDER Right 2x6 SPF No.2 1-9-0
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals, and
2-0-0 oc purlins (5-1-12 max.): 1-3.
BOT CHORD Rigid ceiling directly applied.
WEBS 1 Row at midpt 1-16, 3-15, 3-12, 6-12
REACTIONS.(lb/size)16=1376/0-3-8, 8=1462/0-3-8
Max Horz 16=-303(LC 8)
Max Uplift 16=-135(LC 10), 8=-102(LC 11)
Max Grav 16=1456(LC 2), 8=1541(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-16=-1320/215, 1-2=-1044/218, 2-3=-1044/218, 3-4=-1427/278, 4-6=-1452/265,
6-8=-1993/228
BOT CHORD 14-15=-21/1535, 12-14=-20/1539, 10-12=-58/1537, 8-10=-58/1537
WEBS 1-15=-183/1556, 2-15=-472/185, 3-15=-801/76, 3-14=0/290, 3-12=-783/164,
4-12=-159/1149, 6-12=-626/195, 6-10=0/338
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
16=135, 8=102.
8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T9
Truss Type
Piggyback Base
Qty
7
Ply
1
WIN20
Job Reference (optional)
I31886194
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:45 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-o?RpeiZA4BC584DgTqf0nbvJoEPL9_nuG?FkQ?y9lNG
Scale = 1:62.4
1
2
3
4
5
6
7 8
9
10
11
12
17 16 15 14 132627
3x12 MT18HS
5x6 5x6
7x10
5x9
5x9 3x8 MT18HS
1.5x4
4x4
4x8
4x4
4x8
4x6
1.5x4 6x10
4x6
5-1-2
5-1-2
14-4-2
9-3-0
23-2-14
8-10-12
28-9-3
5-6-5
34-7-0
5-9-13
5-1-2
5-1-2
9-8-10
4-7-8
14-4-2
4-7-8
18-9-8
4-5-6
23-2-14
4-5-6
28-9-3
5-6-5
34-7-0
5-9-13
35-11-8
1-4-8
0-11-1210-6-80-11-122-0-08-6-88.00 12
5.00 12
Plate Offsets (X,Y)-- [1:0-5-14,Edge], [6:0-3-12,0-2-0], [8:0-3-12,0-2-0], [17:0-6-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.86
0.88
0.66
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.33
-0.83
0.36
(loc)
14-16
16-17
11
l/defl
>999
>499
n/a
L/d
240
180
n/a
PLATES
MT20
MT18HS
Weight: 170 lb FT = 20%
GRIP
197/144
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
1-4: 2x4 SPF 2100F 1.8E
BOT CHORD 2x4 SPF No.2 *Except*
1-17: 2x4 SP DSS, 11-15: 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF Stud *Except*
6-16,7-16,7-14,8-14: 2x4 SPF No.2
SLIDER Left 2x8 SP No.2 3-0-0, Right 2x6 SPF No.2 1-9-0
BRACING-
TOP CHORD Structural wood sheathing directly applied, except
2-0-0 oc purlins (4-8-15 max.): 6-8.
BOT CHORD Rigid ceiling directly applied.
WEBS 1 Row at midpt 7-16, 7-14
REACTIONS.(lb/size)1=1382/Mechanical, 11=1467/0-3-8
Max Horz 1=-180(LC 8)
Max Uplift 1=-72(LC 10), 11=-74(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-3=-3533/379, 3-5=-3314/473, 5-6=-1839/287, 6-7=-1434/271, 7-8=-1296/260,
8-9=-1637/267, 9-11=-1867/238
BOT CHORD 1-17=-352/2964, 16-17=-159/1908, 14-16=-35/1438, 13-14=-87/1454, 11-13=-87/1454
WEBS 3-17=0/255, 5-17=-258/1307, 5-16=-695/217, 6-16=-59/734, 7-14=-292/138,
8-14=-36/573
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) Provide adequate drainage to prevent water ponding.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11.
10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T10
Truss Type
Piggyback Base
Qty
3
Ply
1
WIN20
Job Reference (optional)
I31886195
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:27 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-KXM?sYLtJgxezJqDP2Lo3o9EI_G8xrRF7Ctnn2y9lNY
Scale: 3/16"=1’
1
2
3
4
5
6
7
8 9
10
11
12
13
18 17 16 15 142728
3x12 MT18HS
5x6 5x6
7x10
5x9
5x9 3x8 MT18HS
1.5x4
4x4
4x8
4x4
4x8
4x6
1.5x4 6x10
4x6
5-1-2
5-1-2
14-4-2
9-3-0
23-2-14
8-10-12
28-9-3
5-6-5
34-7-0
5-9-13
-1-6-0
1-6-0
5-1-2
5-1-2
9-8-10
4-7-8
14-4-2
4-7-8
18-9-8
4-5-6
23-2-14
4-5-6
28-9-3
5-6-5
34-7-0
5-9-13
35-11-8
1-4-8
0-11-1210-6-80-11-122-0-08-6-88.00 12
5.00 12
Plate Offsets (X,Y)-- [2:Edge,0-0-0], [7:0-3-12,0-2-0], [9:0-3-12,0-2-0], [18:0-6-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.86
0.88
0.65
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.33
-0.83
0.35
(loc)
15-17
17-18
12
l/defl
>999
>498
n/a
L/d
240
180
n/a
PLATES
MT20
MT18HS
Weight: 172 lb FT = 20%
GRIP
197/144
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
1-5: 2x4 SPF 2100F 1.8E
BOT CHORD 2x4 SPF No.2 *Except*
2-18: 2x4 SP DSS, 12-16: 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF Stud *Except*
7-17,8-17,8-15,9-15: 2x4 SPF No.2
SLIDER Left 2x8 SP No.2 3-0-0, Right 2x6 SPF No.2 1-9-0
BRACING-
TOP CHORD Structural wood sheathing directly applied, except
2-0-0 oc purlins (4-9-0 max.): 7-9.
BOT CHORD Rigid ceiling directly applied.
WEBS 1 Row at midpt 8-17, 8-15
REACTIONS.(lb/size)2=1474/0-3-8, 12=1466/0-3-8
Max Horz 2=-187(LC 8)
Max Uplift 2=-98(LC 10), 12=-74(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-3499/365, 4-6=-3275/457, 6-7=-1834/285, 7-8=-1429/269, 8-9=-1294/259,
9-10=-1634/266, 10-12=-1864/237
BOT CHORD 2-18=-345/2929, 17-18=-157/1898, 15-17=-34/1435, 14-15=-86/1452, 12-14=-86/1452
WEBS 4-18=0/258, 6-18=-252/1277, 6-17=-688/215, 7-17=-58/731, 8-15=-290/138,
9-15=-36/571
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) Provide adequate drainage to prevent water ponding.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
8) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12.
10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T11
Truss Type
Piggyback Base
Qty
7
Ply
1
WIN20
Job Reference (optional)
I31886196
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:28 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-okwN4uMV4z3VbTPPzls1b0iPtNctgIoOMsdKKUy9lNX
Scale: 3/16"=1’
1
2
3
4
5
6
7 8 9
10
11
12
13
14
21 20 19
18 17 16 15
3x12 MT18HS
5x6
10x10
5x9
6x8 2x4
3x4
6x8
1.5x4
1.5x4
1.5x4
4x4
5x9
6x8
5x6
4x8
4x6
7x10
1.5x4
5x6
4x6
4x4
5-1-2
5-1-2
14-4-2
9-3-0
20-4-8
6-0-6
23-2-14
2-10-6
27-6-3
4-3-5
31-9-8
4-3-5
34-7-0
2-9-8
-1-6-0
1-6-0
5-1-2
5-1-2
9-8-10
4-7-8
14-4-2
4-7-8
20-4-8
6-0-6
23-2-14
2-10-6
27-6-3
4-3-5
31-9-8
4-3-5
34-7-0
2-9-8
35-11-8
1-4-8
0-11-1210-6-80-11-122-0-01-0-01-0-01-0-01-0-08-6-88.00 12
5.00 12
4.80 12
Plate Offsets (X,Y)-- [2:0-0-15,0-7-13], [7:0-3-12,0-2-0], [9:0-3-12,0-2-0], [13:0-3-11,0-0-2], [15:0-1-11,0-0-0], [18:0-6-0,0-4-0], [21:0-5-4,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-AS
0.88
0.85
0.64
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.28
-0.89
0.38
(loc)
20-21
20-21
13
l/defl
>999
>465
n/a
L/d
240
180
n/a
PLATES
MT20
MT18HS
Weight: 197 lb FT = 20%
GRIP
197/144
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
1-5: 2x4 SPF 2100F 1.8E
BOT CHORD 2x4 SPF No.2 *Except*
2-21: 2x4 SPF 2100F 1.8E, 15-22: 2x4 SP DSS
13-15: 2x4 SPF 1650F 1.5E
WEBS 2x4 SPF Stud *Except*
7-20,7-18,8-17: 2x4 SPF No.2
SLIDER Left 2x8 SP No.2 3-0-0, Right 2x8 SP No.2 2-9-0
BRACING-
TOP CHORD Structural wood sheathing directly applied, except
2-0-0 oc purlins (4-0-14 max.): 7-9.
BOT CHORD Rigid ceiling directly applied.
REACTIONS.(lb/size)2=1474/0-3-8, 13=1466/0-3-8
Max Horz 2=-187(LC 8)
Max Uplift 2=-98(LC 10), 13=-74(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-3501/363, 4-6=-3275/456, 6-7=-1839/289, 7-8=-1645/288, 8-9=-1448/262,
9-10=-1850/283, 10-11=-2194/266, 11-13=-2868/281
BOT CHORD 2-21=-344/2930, 20-21=-158/1896, 17-18=-30/1644, 16-17=-83/1808, 15-16=-143/2133,
13-15=-148/2285
WEBS 4-21=0/264, 6-21=-249/1267, 6-20=-677/213, 7-20=-50/495, 18-20=-49/1390,
7-18=-96/325, 8-17=-485/126, 9-17=-88/815, 10-17=-500/119, 11-15=0/679,
10-16=0/299, 11-16=-349/78
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) Provide adequate drainage to prevent water ponding.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Bearing at joint(s) 2, 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 13.
10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
T12
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886197
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:32 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-gV9uwGP07CZx44jACbwzmssCz?AFcFU_GUbYTGy9lNT
Scale: 3/16"=1’
Sheet Front
Full Sheathing
1 Ply 7/16" 4X8 OSB
1
2
3
4
5
6 7 8
9
10
11
12
13
14 15 16 17 18 19 20 21 22 23
24
25
26
27
28
29
30
3132
57
56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
3x6
3x6
3x6
12x12
3x6
3x6
4x8
4x4
5-1-2
5-1-2
34-7-0
29-5-14
-1-6-0
1-6-0
14-4-2
14-4-2
23-2-14
8-10-12
34-7-0
11-4-2
35-11-8
1-4-8
0-11-1210-6-80-11-122-0-08-6-88.00 12
5.00 12
Plate Offsets (X,Y)-- [2:0-2-9,0-3-13], [2:0-5-11,0-9-10], [3:0-2-2,0-0-0], [14:0-3-0,0-0-2], [22:0-3-0,0-0-2]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.42
0.05
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
0.01
(loc)
31
32
31
l/defl
n/r
n/r
n/a
L/d
120
90
n/a
PLATES
MT20
Weight: 772 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud *Except*
18-44,17-45,16-46,15-47,13-48,19-43,20-41,21-40,23-39: 2x4 SPF No.2
SLIDER Left 2x8 SP No.2 1-9-13, Right 2x6 SPF No.2 1-9-7
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 14-22.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 18-44, 17-45, 16-46, 15-47, 19-43, 20-41,
21-40
REACTIONS.All bearings 34-7-0.
(lb) - Max Horz 2=193(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) 2, 55, 31, 44, 45, 46, 47, 48, 49,
50, 51, 52, 53, 54, 56, 43, 41, 38, 37, 36, 35, 34, 33, 57
Max Grav All reactions 250 lb or less at joint(s) 55, 31, 44, 45, 46, 47, 48, 49,
50, 51, 52, 53, 54, 56, 43, 41, 40, 39, 38, 37, 36, 35, 34, 33, 57 except
2=348(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) All plates are 1.5x4 MT20 unless otherwise indicated.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 55, 31, 44, 45,
46, 47, 48, 49, 50, 51, 52, 53, 54, 56, 43, 41, 38, 37, 36, 35, 34, 33, 57.
12) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2, 55, 31, 44, 45, 46, 47, 48, 49, 50, 51, 52,
53, 54, 56, 43, 41, 40, 39, 38, 37, 36, 35, 34, 33, 57.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V1
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886198
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:46 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-GB?Bs2aoqVKylEns1XAFKoRd6ewtuaX2Uf_HySy9lNF
Scale = 1:52.2
Sheet Back
Full Sheathing
1 Ply 7/16" 4X8 OSB
1
2
3
4
5
6
7
8
9
10
19 18 17 16 15 14 13 12 113x4
3x4
3x4
13-7-10
13-7-10
0-0-49-1-18.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.31
0.16
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
11
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 258 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF Stud *Except*
9-12: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 10-11
REACTIONS.All bearings 13-7-10.
(lb) - Max Horz 1=256(LC 9)
Max Uplift All uplift 100 lb or less at joint(s) 1, 11, 12, 13, 14, 15, 16, 17, 18, 19
Max Grav All reactions 250 lb or less at joint(s) 1, 11, 12, 13, 14, 15, 16, 17, 18, 19
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) All plates are 1.5x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 12, 13, 14,
15, 16, 17, 18, 19.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V2
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886199
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:49 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-gmhJU4dg7QiXchWRigkyyR369rxa5wyUBdDxZny9lNC
Scale = 1:43.9
1
2
3
4
7 6 53x4
1.5x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
11-7-10
11-7-10
0-0-47-9-18.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.39
0.16
0.13
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 44 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 11-7-4.
(lb) - Max Horz 1=217(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 6=-103(LC 10)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=438(LC 17), 7=309(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-6=-274/156
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except
(jt=lb) 6=103.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V3
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886200
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:49 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-gmhJU4dg7QiXchWRigkyyR36Urx65xLUBdDxZny9lNC
Scale = 1:37.6
1
2
3
5 462x4
1.5x4
1.5x4 1.5x4
1.5x4
9-7-10
9-7-10
0-0-46-5-18.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.43
0.19
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 34 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=165/9-7-4, 4=99/9-7-4, 5=458/9-7-4
Max Horz 1=177(LC 7)
Max Uplift 4=-30(LC 7), 5=-133(LC 10)
Max Grav 1=178(LC 18), 4=162(LC 17), 5=520(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-353/208
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
5=133.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V4
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886201
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:50 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-8zFihQdIukqNEr5eGNFBUecK0FIcqPHePHyV5Dy9lNB
Scale = 1:29.7
1
2
3
5 42x4
1.5x4
1.5x4 1.5x4
1.5x4
7-7-10
7-7-10
0-0-45-1-18.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.26
0.11
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 26 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=86/7-7-4, 4=122/7-7-4, 5=353/7-7-4
Max Horz 1=138(LC 9)
Max Uplift 1=-6(LC 6), 4=-26(LC 7), 5=-102(LC 10)
Max Grav 1=110(LC 18), 4=133(LC 17), 5=361(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-272/167
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb)
5=102.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V5
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886202
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:50 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-8zFihQdIukqNEr5eGNFBUecHQFFAqPFePHyV5Dy9lNB
Scale = 1:22.4
1
2
32x4
1.5x4
1.5x4
5-7-10
5-7-10
0-0-43-9-18.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.42
0.26
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 17 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-7-10 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=200/5-7-4, 3=200/5-7-4
Max Horz 1=99(LC 7)
Max Uplift 1=-7(LC 10), 3=-42(LC 10)
Max Grav 1=200(LC 1), 3=211(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V6
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886203
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:51 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-d9p4vlewf1yEs?gqp5mQ1s9Wafe8ZsVnexi2efy9lNA
Scale = 1:15.0
1
2
3
2x4
1.5x4
1.5x4
3-7-10
3-7-10
0-0-42-5-18.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.14
0.09
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 10 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-7-10 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=120/3-7-4, 3=120/3-7-4
Max Horz 1=59(LC 7)
Max Uplift 1=-4(LC 10), 3=-25(LC 10)
Max Grav 1=120(LC 1), 3=127(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V7
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886204
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:51 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-d9p4vlewf1yEs?gqp5mQ1s9YYffMZsVnexi2efy9lNA
Scale = 1:8.3
1
2
3
2x4
1.5x4
1.5x4
1-7-10
1-7-10
0-0-41-1-18.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.01
0.01
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 4 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-7-10 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=40/1-7-4, 3=40/1-7-4
Max Horz 1=20(LC 9)
Max Uplift 1=-1(LC 10), 3=-8(LC 10)
Max Grav 1=40(LC 1), 3=42(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V8
Truss Type
GABLE
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886205
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:52 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-5LMS65fZQL45T9F0NoHfa3he93z4IIRwtbRcA5y9lN9
Scale = 1:53.2Sheet Back
Full Sheathing
1 Ply 7/16" 4X8 OSB
1
2
3
4
5
6
7
8
9
10
11
21 20 19 18 17 16 15 14 13 12
5x6
3x4
3x4
5x6
14-4-8
14-4-8
14-0-15
14-0-15
14-4-8
0-3-9
0-0-49-4-109-2-48.00 12
*** Design Problems ***
REVIEW REQUIRED
Analog warning - check design
Plate Offsets (X,Y)-- [6:0-3-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.34
0.17
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
12
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 285 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF Stud *Except*
10-13,9-14: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 11-12, 10-13
REACTIONS.All bearings 14-4-8.
(lb) - Max Horz 1=268(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) 12, 1, 13, 14, 15, 16, 17, 18, 19,
20, 21
Max Grav All reactions 250 lb or less at joint(s) 12, 1, 13, 14, 15, 16, 17, 18, 19,
20, 21
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) All plates are 1.5x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 1, 13, 14, 15,
16, 17, 18, 19, 20, 21.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V9
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886206
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:52 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-5LMS65fZQL45T9F0NoHfa3hfD3z5IHVwtbRcA5y9lN9
Scale = 1:48.7
1
2
3
4
7 6 53x4
5x6
2x4 1.5x4
1.5x4
1.5x4
1.5x4
12-4-8
12-4-8
12-0-15
12-0-15
12-4-8
0-3-9
0-0-48-0-107-10-48.00 12
*** Design Problems ***
REVIEW REQUIRED
Analog warning - check design
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.27
0.17
0.14
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 47 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-5
REACTIONS.All bearings 12-4-2.
(lb) - Max Horz 1=228(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6, 7
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=434(LC 17), 7=332(LC
1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-6=-274/142
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6, 7.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V10
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886207
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:46 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-GB?Bs2aoqVKylEns1XAFKoRaIevruaK2Uf_HySy9lNF
Scale = 1:42.2
1
2
3
5 42x4
4x6
1.5x4 1.5x4
1.5x4
10-4-8
10-4-8
10-0-15
10-0-15
10-4-8
0-3-9
0-0-46-8-106-6-48.00 12
*** Design Problems ***
REVIEW REQUIRED
Analog warning - check design
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.49
0.22
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 37 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=180/10-4-2, 4=99/10-4-2, 5=492/10-4-2
Max Horz 1=189(LC 7)
Max Uplift 4=-28(LC 7), 5=-142(LC 10)
Max Grav 1=192(LC 18), 4=167(LC 17), 5=576(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-379/220
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
5=142.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V11
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886208
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:47 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-kOZZ3ObQbpSpNNM3aFiUt0_o32HZd1RBjJkrVuy9lNE
Scale = 1:33.3
1
2
3
5 42x4
4x6
1.5x4 1.5x4
1.5x4
8-4-8
8-4-8
8-0-15
8-0-15
8-4-8
0-3-9
0-0-45-4-105-2-48.00 12
*** Design Problems ***
REVIEW REQUIRED
Analog warning - check design
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.30
0.13
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 28 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
OTHERS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=105/8-4-2, 4=123/8-4-2, 5=382/8-4-2
Max Horz 1=149(LC 7)
Max Uplift 1=-3(LC 6), 4=-24(LC 7), 5=-109(LC 10)
Max Grav 1=127(LC 18), 4=134(LC 17), 5=391(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-294/177
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb)
5=109.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V12
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886209
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:47 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-kOZZ3ObQbpSpNNM3aFiUt0_kN2D1d2WBjJkrVuy9lNE
Scale = 1:25.7
1
2
32x4
4x6
1.5x4
6-4-8
6-4-8
6-0-15
6-0-15
6-4-8
0-3-9
0-0-44-0-103-10-48.00 12
*** Design Problems ***
REVIEW REQUIRED
Analog warning - check design
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.54
0.35
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 19 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=230/6-4-2, 3=221/6-4-2
Max Horz 1=110(LC 7)
Max Uplift 1=-10(LC 10), 3=-46(LC 10)
Max Grav 1=230(LC 1), 3=232(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V13
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886210
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:48 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-Ca7xHkc2M6ag?XxF8yDjPDX_IRbbMVlLyzTO1Ky9lND
Scale = 1:16.4
1
2
3
2x4
4x6
1.5x4
4-4-8
4-4-8
4-0-15
4-0-15
4-4-8
0-3-9
0-0-42-8-102-6-48.00 12
*** Design Problems ***
REVIEW REQUIRED
Analog warning - check design
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.21
0.14
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 13 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-4-8 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=150/4-4-2, 3=141/4-4-2
Max Horz 1=71(LC 7)
Max Uplift 1=-7(LC 10), 3=-29(LC 10)
Max Grav 1=150(LC 1), 3=147(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
Job
1701490
Truss
V14
Truss Type
Valley
Qty
1
Ply
1
WIN20
Job Reference (optional)
I31886211
8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Dec 12 09:28:48 2017 Page 1 84 Lumber0783, Franklin, Indiana
ID:F0HirQrWp4Ax3R5F9s3xpbyX9i_-Ca7xHkc2M6ag?XxF8yDjPDX1yRdMMVlLyzTO1Ky9lND
Scale = 1:9.8
1
2
3
2x4
4x6
1.5x4
0-0-6
0-0-6
2-4-8
2-4-2
2-0-15
2-0-15
2-4-8
0-3-9
0-0-41-4-101-2-48.00 12
*** Design Problems ***
REVIEW REQUIRED
Analog warning - check design
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.04
0.03
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 6 lb FT = 20%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-4-8 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=70/2-4-2, 3=61/2-4-2
Max Horz 1=31(LC 7)
Max Uplift 1=-4(LC 10), 3=-13(LC 10)
Max Grav 1=70(LC 1), 3=64(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
December 12,2017
edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.