HomeMy WebLinkAboutE100.1 - Elec Notes & Panel SchedulesLIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION LAMP MANUFACTURER PART# VOLTAGE WATTAGE COLUMBIA A 2 x 4 LED CONTEMPOMRYARCHITECTURAL TROFFER BY MFG. LCAT2435VLG-E UNV 58 NORA B LED TRACK HEAD LED14E26P3030KNFLB NTH-109LED 120 14 CEILING MOUNTED I SUSPENDED FIXTURE OWNER PROVIDE C PROVIDED BY OWNER I INSTALLED BY CONTRACTOR 160 WATT 120 60 MAX. LITHONIA D fi" RECESSED LED CAN LIGHT BY MFG. REALK DfiMW ESL 1500E 30K.65SC 120 120 188 EMi EMERGENCY DUAL HEAD FIXTURE WITH 90 MIN. BATTERY BACKUP. WALL BY MFG. SIMKAR UNV 5A MOUNTED A MIN. OF 1' 0' BELOW CEILING OR 13'4" IN AREAS WITH NO SEMW CEILING. ER EXISTING DUAL EXIT DISCHARGE LIGHT(SEALED AND GASKETED) FED BY MFG. RX'GSIMKAR 5A FROM EXIT SIGN. WALL MOUNTED A MIN. OF 1'V ABOVE DOOR HEAD AND REM2WP 6 POWERED FROM BATTERY SIDE OF EXIT LIGHT. EXi LED EXIT LIGHT COMBO WITH HIGH OUTPUT 90 MIN. BATTERY TO FEED BY MFG. SIMKAR UNV 5A EXIT DISCHARGE LIGHT. WALL MOUNTED MIN. OF VABOVE DOOR OR $CL12RW,REM SURFACE MOUNTED ON CEILING. REMOTE CAPABLE EX2 LED EXIT LIGHT COMBO WITH 90 MIN. BATTERY BACK-UP. WALL MOUNTED BY MFG. SIMKAR UNV 5A MIN. OF TABOVE DOOR OR SURFACE MOUNTED ON CEILING. SCL12RW METALUX F 4'LED STRIPLIGHT BY MFG. 4SLSTP204DOUNV UNV 23 T-FT SEE PLAN FOR TRACK LENGTH WITH 1316B END FEED, NT 310B NORA 120 CONNECTOR & 1.5 AMP CURRENT LIMITER (UNLESS NOTED OTHERWISE). NT-300 SERIES TRACK BLACK SURFACE MOUNTED ALL FIXTURES & BULBS ARE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. WIRING METHODS'. ALL CONDUIT AND WIRING SIZES ARE SHOWN ON THE PANEL SCHEDULES AND RISER DIAGRAM. TYPES APPROVED ARE AS FOLLOWS: OUTDOORS: USE THE FOLLOWING TYPES OF CONDUIT. 1. EXPOSED'. RIGID STEEL OR NO 2. CONCEALED'. RIGID STEEL OR INC 3. UNDERGROUND: RHO INDOORS: USE THE FOLLOWING WIRING METHODS: 1. EXPOSED'. INC OR RIGID STEEL 2. CONCEALED . EMT WIRING CONDUCTORS SHALL BE SOFTANNEALED 98%COPPER. ALL CONDUCTORS LARGER THAN 9 AWG SHALL BE STRANDED. MINIMUM SIZE CONDUCTOR SHALL BE 912 AWG UNLESS OTHERWISE SPECIFIED. NO ALUMINUM CONDUCTORS WILL BE PERMITTED. TYPE THHN SHALL NOT BE USE UNDERGROUND, OUTSIDE, AT SERVICE ENTRANCES OR IN WET LOCATION. ALL INSULATION SHALL BE RATED AT 600 VOLTS. THE FOLLOWING INSULATION TYPES ARE PERMITTED'. #10 AWG AND SMALLER THW, THIN #8 AWG TO #410 AWG THW, THHN SERVICE ENTRANCE USE RHW WIRE THROUGH FLUORESCENT FIXTURE OR WITHIN 3OF HEATING EQUIPMENT THHN TERMINATION PROVISIONS OF EQUIPMENT FOR CIRCUITS OF 100 AMPERES OR LESS SHALL UTILIZE CONDUCTOR AMPACITIES BASED ON 60 DEGREES CELCIUS TEMPERATURE RATINGS SEE 2014 NEC TABLE 310.16 FOR AMPACITYRATINGS. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes Ciity1yGF Canted �VT�121�0*VAWML DATE: \\ 02/13/19 GENERAL ELECTRIC NOTES 1. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS PRIOR TO SUBMITTING A PROPOSAL. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2014 EDITION OF THE NATIONAL ELECTRIC WOE & 2012 INTERNATIONAL ENERGY CONSERVATIO1 CODE. 3. ALL CONDUCTORS SHALL BE COPPER#12 MINIMUM. 4, ALL CONDUITS SHALL HAVE PROPERLY SIZED EQUIPMENT GROUNDING CONDUCTORS. 5. PROVIDE THE NECESSARY PUWJUNCTION BOXES, SUPPORTS AND MISC. ITEMS FOR A COMPLETE INSTALLATION. 6. PROPERLY SEAL ALL PENETRATIONS OF FIRE RATED CONSTRUCTION AREAS. T. PROVIDE TYPE WRITTEN PANEL DIRECTORIES. 8. All WIRING SHALL BE IN CONTINUOUS CONDUIT SYSTEMS. 9. ALL LIGHT FIXTURES SHALL BE SUPPORTED INDEPENDENTLY OF SUSPENDED CEILINGS. 10. ELECTRICAL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES. 11. SWITCHES AND RECEPTACLES SHALL BE 20 AMP COMMERCIAL GRADE. 12. CONCEAL ALL CONDUITS AND BOXES UNLESS OTHERWISE NOTED. 13. COORDINATE ALL POWER REQUIREMENTS WITH LOCAL POWER COMPANY ENGINEER. 14. PROVIDE AND MAINTAIN TEMPORARY POWER AND LIGHTING SYSTEM FOR DURATION OF THE PROJECT. M EMT FITTINGS SHALL BE DIE CAST SET SCREW. 16, MAKE FINAL CONNECTIONS TO EQUIPMENT WITH FLEXIBLE METAL CONDUIT. LIQUID TIGHT WHERE EXPOSED TO WEATHER. 17. ALL OUTLET COVERS AND SWITCH PLATES TO BE WHITE. 18. INSTALLATION OF ALL ELECTRICAL WIRING MUST BE INSTALLED IN CONDUIT ON THE G1 GARAGE LEVEL. PANEL "A" - RELOCATED 120/208 VOLTS 3 PHASE 4 WIRE ISCARATING 10,000 NEMA RATING:I MOUNTING: RECESSED MAINS: 200A M.L.O. TOTAL CONNECTED LOAD 33.81 "A LOAD SERVED a Fro, ou 0 z 0 < OCT. OCT. NO. NO. ABC < o z U IY U w 4of a a ­ LOAD SERVED PTO 1' MCA 252 1MOCP. 35 35 3/4 10 10 2.42 t 2 1.2 12 12 12 0 LIGHTING" 10 262 3 6 0.5 12 12 12 0 SIGNAGE(VIA TIMECLOCK) 10 T442 5 e 0.5 12 12 12 0 REC.-RESTROOMS REC. -RTU/SMOKE DETECTORS 20 12 12 12 0.5 1 6 2.83 2,83 10 10 314 RTU-2 MCA: 29.51 MOCP: 45 REC.- TELEPHONE 20 12 12 12 05 9 10 10 REC.-STEREO SYSTEM 20 12 12 12 10 11 12 2.83 10 DRINKING FOUNTAIN(GH BREAKER) 20 12 12 12 1.0 13 14 2.0 12 12 12 20 REC.-SHOW WINDOWS REG- GENERAL 20 12 12 12 1.0 15 12 12 12 0 LIGHTING" REC.-GENERAL 20 12 12 12 1.0 12 12 12 12 0 DH-2 REC. - RECEPTION CTR. 20 12 12 12 1.0 19 12 12 12 0 DH-1 REC. - RECEPTION CTR. 20 12 12 12 1.0 21 12 12 314 0 WATER HEATER' REC.- COOLER 20 12 12 12 07 23 12 WALL SIGNAGE 20 12 12 12 0.2 25 r SPACE ONLY SPARE 20 27 SPACE ONLY SPARE 20 - 29 SPACE ONLY SPARE 20 - 3t SPACE ONLY SPARE 20 - 33 SPACE ONLY SPARE 20 35 SPACE ONLY SPARE 20 - - - - 31 33 - - - - SPACE ONLY SPARE 20 39 40 - SPACE ONLY SPARE 20 - - - - JjLe 42 - - - SPACE ONLY PHASE 'A': 12.03 KVA '- VERIFY ELEC. LOAD I REQUIREMENTS PRIOR TO PURCHASING EQUIPMENT PHI'B': 10.95 KVA "-LOCKABLE CIRCUIT BREAKERS SHALL BE PROVIDED FOR ANY BRANCH CIRCUIT THAT FEEDS UNIT EQUIPMENT FOR EMERGENCY LIGHTING PHASE'C': 10.83 KVA 33.81 KVA @ 1201206130- 94 AMPERES PANEL LOCATED IN REAR HALLWAY GERALD P. NOE ARCHITECT INDIANA REG. NO. AR10700206 399 LUCERNE DRIVE SPARTANBURG, SC 29302 P: 864.583.2215 F: 864.583.2265 mail@gpnarcht.com CHECKED BY: JMF DRAWN BY: JMF; DKH THIS DRAWING IS AN INSTRUMENT OF SERVICE AND SOLE PROPERTY OF THE ARCHITECT, AND SHALL NOT BE USED IN ANY WAY. WHATSOEVER, WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT. IT SHALL BE RETURNED TO THE ARCHITECT UPON DEMAND. COPYRIGHT 2019 ALL RIGHTS RESERVED cs� r4�j�*k $ STAiEOF �MDIpMa � 9RCHiTE�' DATE: 2019-02-07 REVISIONS: NO. DATE MSCRIMON BY CLIENT NAME: pure barre lift - tone' burn KILBURN HOLDINGS, I TAD OR JESSICA, KILBURN 4261 HAZY LANE GREENWOOD, IN 46142 E: JESSICA.KILBURN@PUREBARREMOM PROJECT NAME: pure Barre lift • tone' burn INTERIOR UP -FIT WESTON POINTE SHOPPES 11145 N. MICHIGAN ROAD SUITE 150 ZIONSVILLE. IN all ELECTRICAL NOTES & PANEL SCHEDULES PROJECT NUMBER: 18-A105 DATE: 2018-12-14 SHEET NO. E10001 SHEET � OF