Loading...
HomeMy WebLinkAboutGN010.0 - Cover SheetINTERIOR UP -FIT FOR lift tone burn WESTON POINTE SHOPPES 11145 N. MICHIGAN ROAD -SUITE ZIONSVILLE, IN 46077 GENERAL NOTES: 1. THESE DRAWINGS ARE AN I NSTRUM ENT OF CONDITIONAL SERVICES. THE ARCHITECT TAKES NO RESPONSIBILITY FOR ACTUAL FIELD CONDITIONS AND CONSTRUCTION. THESE DRAWINGS ARE TO CONVEY DESIGN INTENTIONS AND CODE COMPLIANCE ONLY. ACTUAL LOCATIONS AND DIMENSIONS TO BE FIELD VERIFIED. _TFICT,LCCJFD11%fE I IT LLL LDCL.L CDDLS, 2014 Indiana Building Code 2014 Indiana Fire Code 2012 Indiana Plumbing Code 2014 Indiana Mechanical Cade W09 Indiana Electrical Code 2010 Indiana Energy Conservation Code 3. ALL CONSTRUCTION MATERIAL AND INSTALLATION OF MECHANICAL, ELECTRICAL, & PLUMBING SHALL BE IN STRICT ACCORDANCE WITH ALL LOCAL CODES & ORDINANCES. 4. ALL CONSTRUCTION MATERIAL AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH 2O09 IBC STANDARD. 5. COORDINATION OF ALL TRADES IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND IS ESSENTIAL TO THE COMPLETION OF THE PROJECT. 6. BY EXECUTING THE CONTRACT, THE CONTRACTOR REPRESENTS THAT HE HAS VISITED THE SITE FAMILIARIZED HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND CORRELATED HIS OBSERVATIONS WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. 7. NO CHANGE ORDERS WILL BE ISSUED FOR CHANGES REQUIRED IN THE WORK DUE TO AN INCOMPLETE FIELD VISIT BY THE CONTRACTOR PRIOR TO BIDDING. 8. NO CHANGE ORDERS WILL BE ISSUED FOR CHANGES REQUIRED IN THE WORK AFTER CONSTRUCTION HAS COMMENCED UNLESS SPECIFICALLY AUTHORIZED BY AN OWNERS REPRESENTATIVE. 9. AN ERROR OR OMISSION IN THESE DOCUMENTS RESULTING IN A CHANGE ORDER FOR ADDITIONAL COST AND / OR TIME SHALL NOT BE CONSIDERED A HARDSHIP OR DAMAGE TO THE OWNER TO THE EXTENT THAT THE ADDITIONAL COST AND TIME WOULD HAVE INCREASED THE BASE BID PRICE AND / OR TIME HAD THERE BEEN NO ERROR OR OMISSION IN THE DOCUMENTS AD THE TIME BIDS WERE RECEIVED. THE OWNER ACKNOWLEDGES THAT THE WORK ASSOCIATED WITH THE ERROR OR OMISSION, HAD IT BEEN INCLUDED IN THE BASE BID, WOULD HAVE AFFECTED THE TIME AND COST OF THE ORIGINAL BASE BID PRICE. THE OWNER IN NOT ENTITLED TO BENEFIT FROM FREE OR REDUCED COST OR TIME FOR WORK THAT WOULD HAVE OTHERWISE INCREASED THE CONTRACT TIME AND OR COST OF THE BASE BID HAD NO ERROR OR OMISSION BEEN IN THE BID DOCUMENTS. 10. GENERAL CONTRACTOR TO VERIFYALL DIMENSIONS AT THE JOB SITE AND REPORT ANY DISCREPANCIES TO THE ARCHITECT. THE G.C. IS RESPONSIBLE FOR PROPER FIT AND INSTALLATION OF ALL WORK SHOWNBON THESE DRAWINGS. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR ANY FABRICATION OF INSTALLATION TECHNIQUES PROVIDED BY THE G.C. OR ANY OF HIS SUBCONTRACTORS. 11. G.C. TO SECURE AND PAY FOR ALL PERMITS, TEMPORARY UTILITIES AND CARRY LIABILITY INSURANCE AS REQUIRED. 12. ALL DIMENSIONS ARE TO THE FACE OF BLOCK, STUD OR CENTERLINE UNLESS NOTED OTHERWISE. 13. ALL INTERIOR STUD WALLS TO BE METAL STUDS AT 16" O.C. WITH GYPSUM BOARD AT EACH FACE AS DETAILED. UNLESS NOTED OTHERWISE. 14. ALL FLOOR FINISHES TO BE LEVEL AND FLUSH AT INTERSECTIONS. UNLESS OTHERWISE NOTED. 15. CEILING SUSPENSION SYSTEM TO BE SECURED TO STRUCTURAL MEMBERS OR ADDITIONAL SUPPORTS ABOVE. 16. G.C. TO PROVIDE COMPLETE SHOP DRAWINGS FOR ALL NECESSARY WORK AS SPECIFIED FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �V�1��V'�9a141WM<_ DATE: \ 02/13/19 PROJECT'SCOPE OF WORK': THE CURRENT SPACE WAS PREVIOUSLY A RETAIL STORE. THE UPFIT CONSISTS OF MINOR SLAB DEMO FOR UNDERSLAB UTILITIES, NEW INTERIOR WALLS (NON LOAD BEARING) WITH NEW FINISHES THROUGHOUT. MINIMAL PLUMBING WORK CONSISTING OF MODIFYING EX'G RR TO ADA STANDARDS, UTILITY SINK & ADA COMPLIANT HI-LO DRINKING FOUNTAIN, (1) EXG HVAC UNIT & (1) NEW HVAC UNIT W/ DISTRIBUTION THROUGHOUT SPACE AND MINOR ELECTRICAL WORK INCLUDING PANEL W/ CIRCUITS AND RUNS THROUGHOUT SPACE. MOLD AND MILDEW NOTES: THE FOLLOWING REQUIREMENTS SHALL APPLYTO ALL NEW & REMODEL CONSTRUCTION PROJECTS. 1. IN THE EVENT THE CONTRACTOR DISCOVERS AT ANYTIME DURING DEMOLITION, CONSTRUCTION, AND/OR REMODELING OPERATIONS, EXISTING CONDITIONS THAT COULD INCLUDE THE PRESENCE OF MOLD AND/OR MILDEW THE CONTRACTOR SHALL IMMEDIATELY NOTIFYTHE OWNER'S REPRESENTATIVE AND THE ARCHITECT/ENGINEER OF RECORD, IN WRITING OF THE CONCERNS AND/OR SUSPICIONS. 2. CONCURRENTLY THE CONTRACTOR SHALL BE RESPONSIBLE TO RETAIN A MOLD & MILDEW CERTIFIED TESTING AGENCY TO PERFORM AN INVESTIGATION AND TESTING AS REQUIRED TO EVALUATE THE NATURE & EXTENT OF THE PROBLEM. IF THE TESTING AGENCY CONFIRMS HAZARDS, THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN A MINIMUM OF (2) BIDS FROM COMPANIES QUALIFIED & LICENSED TO PERFORM ALL NECESSARY REMEDIATION WORK COMPLYING WITH ALL LOCAL, STATE & FEDERAL ENVIRONMENTAL REGULATIONS, CODES & STATUTES. 3. ONCE DISCOVERY OR SUSPICION OF MOLD AND/OR MILDEW IN MADE, THE CONTRACTOR SHALL TAKE ALL REASONABLE & PRACTICAL PRECAUTIONS TO PROTECT ALL CONSTRUCTION PERSONNEL & THE PUBLIC FROM EXPOSURE TO MOLD AND/OR MILDEW AND SUCH PRECAUTIONS SHALL REMAIN IN PLACE UNTIL SUCH TIME AS THE OWNER OR HEALTH AUTHORITY DIRECT OTHERWISE. CONSTRUCTION OPERATIONS SHALL NOT BE STOPPED OR CURTAILED, EXCEPT IN THE AREA OF MOLD AND/OR MILDEW CONCERN DUE TO THESE REQUIRED PRECAUTIONS. 4. THE CONTRACTOR SHALL MAKE ALL REASONABLE EFFORTS TO AVOID CONDITIONS FAVORABLE TO THE DEVELOPMENT OF MOLD AND/OR MILDEW, ESPECIALLY IN VOIDS WHICH WILL BE CONCEALED AND NOT VENTILATED IN ALL CASES INTERIOR SPACES AND INTERIOR FURNISHED CONSTRUCTION SHALL BE MAINTAINED IN DRY& WELL VENTILATED CONDITIONS. 5. THE CONTRACTOR SHALL COMPLY WITH FEDERAL ENVIRONMENTAL AND OHBA REGULATIONS & ALL LOCAL & STATE HEALTH DEPARTMENT REQUIREMENTS & RECOMMENDATIONS REGARDING MOLD & MOLD. 4. THE CONTRACTOR SHALL MAKE ALL REASONABLE EFFORTS TO AVOID CONDITIONS FAVORABLE TO THE DEVELOPMENT OF MOLD AND/OR MILDEW, ESPECIALLY IN VOIDS WHICH WILL BE CONCEALED AND NOT VENTILATED IN ALL CASES INTERIOR SPACES AND INTERIOR FURNISHED CONSTRUCTION SHALL BE MAINTAINED IN DRY & WELL VENTILATED CONDITIONS. 5. THE CONTRACTOR SHALL COMPLY WITH FEDERAL ENVIRONMENTAL AND OHBA REGULATIONS & ALL LOCAL & STATE HEALTH DEPARTMENT REQUIREMENTS & RECOMMENDATIONS REGARDING MOLD & MOLD. 6. ALL PENETRATIONS SHALL BE SEALED WATER -TIGHT TO PREVENT MOISTURE MIGRATION FROM ENTERING THE BUILDING OR WALL CAVITIES. 7. ALL CONDENSATE DRAIN PANS SHALL BE CLEANED & KEPT FREE FROM DEBRIS UNTIL & WHEN THE FACILITY IS TURNED OVER TO THE OWNER OR TENANT. ENSURE POSITIVE DRAINAGE AT ALL DRAIN PANS, ENSURE THAT ALL "COLD" SURFACES ARE INSULATED & COVERED WITH A FULLY SEALED & CONTINUOUS VAPOR BARRIER ("COLD" SURFACES INCLUDE, BUT ARE NOT LIMITED TO DOMESTIC COLD WATER PIPING, CHILLED WATER PIPING, INTERIOR RAIN LEADERS, OUTDOOR AIR INTAKES, & DUCTWORK CARRYING AIR CONDITIONED SUPPLYAIR) B. ENSURE THAT THERE ARE NO WATER LEAKS IN CONCEALED PLUMBING CHASES RETURN AIR PATHS & PLENUMS SHALL BE KEPT DRY. ALL EXISTING SUPPLY AIR PATHS & ALL EXISTING DUCTWORK TO BE RE -USED BE CLEANED & TREATED AS REQUIRED TO REMOVE THE POTENTIAL FOR MOLD & MILDEW. ALL DAMP AREAS SHALL BE DRIED THOROUGHLY PRIOR TO ENCLOSURE. 150 INDEX OF DRAWINGS O ISSUED FOR REVIEW • REVISED & REISSUED DRAWING GENERAL W U) w X W X ¢ 2 W m Z N O N Q F m r Z) O U) O ~ fr N (L GN010.0 COVER SHEET & CODE EVALUATION O O LS100.0 LIFE SAFETY PLAN O O DMO10.0 DEMOLITION PLAN Cl O A01 O.O DIMENSIONED FLOOR PLAN & NOTES O O A010.1 TYPICAL MILLWORK DETAILS O O A010.2 WALL DETAILS O O A010.3 INTERIOR ELEVATIONS O O A010.4 REFLECTED CEILING PLAN & DETAILS O O A010.5 ENLARGED RESTROOM PLANS Et DETAILS O 1 O A010.6 SCHEDULES, NOTES & DETAILS O O A101 .7 TYPICAL U.L. DETAILS O O P100.0 PLUMBING PLANS O O P100.1 GAS PIPING PLAN O O P100.2 PLUMBING NOTES & DETAILS O O M100.0 MECHANICAL PLAN & DETAILS O O M100.1 MECHANICAL NOTES & DETAILS O O E100.0 POWER & LIGHTING PLANS O O E100.1 ELECTRICAL NOTES & PANEL SCHEDULES O O GERALD P. NOE ARCHITECT INDIANA REG. NO. AR10700206 399 LUCERNE DRIVE SPARTANBURG, SC 29302 P: 864.583.2215 F: 864.583.2265 mail@gpne rcht.com CHECKED BY: JMF DRAWN BY: JMF; DKH THIS DRAWING IS AN INSTRUMENT OF SERVICE AND SOLE PROPERTY OF THE ARCHITECT, AND SHALL NOT BE USED IN ANY WAY. WHATSOEVER. WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT. IT SHALL BE RETURNED TO THE ARCHITECT UPON DEMAND. COPYRIGHT 2019 ALL RIGHTS RESERVED G\STfp STATE OF 401 AMP DATE: 2019-02-07 REVISIONS: NO. DATE DESCHIMOry HY CLIENT NAME: pure barre lift • tone • burn KILBURN HOLDINGS, LLC TAD OR JESSICA KILBURN 4261 HAZY LANE GREENWOOD, IN 46142 E: JESSICA.KILBURN@PUREBARRE.COM PROJECT NAME: pure Barre lift • tone • burn INTERIOR UP -FIT WESTON POINTE SHOPPES 11145 N. MICHIGAN ROAD SUITE 150 ZIONSVILLE, IN 46077 SHEET TITLE: COVER SHEET & CODE EVALUATION PROJECT NUMBER: 18-A105 DATE: 2018-12-14 SHEET NO. GN01000 SHEET 1 OF 1