HomeMy WebLinkAboutE70.1 Elec Basement 1st FlrU
MECHANIC. /
04
DD 2 3QDF2 \
/0
MIT I
I I
A2 /
/ ODFI /
Ate' \ A /
d- \ STUDY
\ AO2 _®� _
\ A2
-0
I
d
h I luh
�1 BASEMENT LIGHTING PLAN - LOT 70
114" = 1'-0"
GARAGE
04
U
U
U
N.
OB
WK
U
_
1
At
At
I
/
I
\
MOWN
Al
ODF4
/
Al
)0
¢'
a
/
I
WIN,- _
I
s
FAMILY RM,
I
1O1
1
\ Al
_ — _
Al
3O OF
(
Y.
A
A A
I
AID
D
e
7 I
0
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Camlel (�
�VT�47'�GNtiYWML
DATE: \ 02/12/19
;1 FIRST FLOOR LIGHTING PLAN -LOT 70
114" = 1' 0"
FROVNE LET H06MAY
L6HTBWNCH.VERPY
EXACT LOCAi6NWIIH
LETSUPPLIER.
ADD SWITCH I L6B RECEPTACLECOMBO
AND JUNCTION BOX OF SCONCE IN
AND JUNCTION Box FOR SCONCE IN
CASEWORK CENTER WITHIN CABINET
MECHANICAL
BATCH FOR r®
POWER CIRCUIT 39
WC 15 TA RACK
WC
WIC
03
STUDY
02
CLOSET
h LL W W JF-L luh
5 BASEMENT POWER PLAN - LOT 70
'' 114" , 1'-0"
FEW OUTLET LOCATION.
CONFIRM EXACT TYPE CIRCUIT AND
LOCATION WITH CUSTOM LNNG
ANION TO ROUGH-M.
GARAGE HEATER
a
GARAGE
104
®�
BICYCLE CHARING OUTLET F2U F3U
LOCATION. CONFIRM EXACT 19
LOCATION WITH CUSTOM LIVING
PRIOR No ROUGRIN. LOTT
FAMILY RM.
01
OUTLETINSTALLEDIH STAIR
CASE NEWEL PoBT. VERIFY
EXACT LOCATION WITH CUSTOM
HIND PRIOR TO ROUGH IN
— OUTLETSNSTAUEDNwSE. —
VILIFY EXACT LOCATION WITH
CUSTOM MIND PRIOR TO ROUGH IN.
FIRST FLOOR POWER PLAN -LOT 70
�J 114" = 1'-0"
BASEMENTSYSTEMS PLAN -LOT 70
\ " ve" - r-nN
FIRST FLOOR SYSTEMS PLAN - LOT 70
U 114" = 1'-0"
PLAN NOTES
(NOT ALL NOTES MAY BE USED ON THIS SHEET) I I
1 DO NOT ROUTE ANY WI RI NG,PIPING, DUCTWORK, ETC., THROUGH LIFT SHAFT.
2 INSTALL LIGHT FIXTURE ABOVE VANITY MIRROR AT HEIGHT DETERMINED BY CUSTOM LIVING. I I I I I I I
3 SURFACE MOUNT I SUSPEND LIGHT FIXTURE TO HEIGHT DETERMINED BY CUSTOM LIVING.
4 LIGHT FIXTURES) INSTALLED IN CASEWORK. COORDINATE LOCATION WITH CUSTOM LIVING PRIOR TO
INSTALLATION.
5 INSTALL CEILING FAN CENTERED IN CEILING SPACE OF ROOM. PROVI OF U.L. LISTED CEILING FAN OUTLET KIT
RATED FOR FANS UP TO 70 PQUN DS,
6 CENTER LIGHT FIXTURE WITHI N STAIRCASE CEILI NO SPACE.
7 LIGHT FIXTURE PROVIDED IN CORE AND SHELL PACKAGE.
8 INSTALL LIGHT FIXTURE AT HEIGHT DETERMINED BY CUSTOM LIVING.
9 CONNECT ALL L IGHTING ON THIS FLOOR TO A DEDICATED I MV,20A, I P CIRCU T, UNLESS OTHERWI BE NOTED.. CERTIFICATION:
10 DEVICE(S) INSTALLED IN CASEWORK. COORDINATE LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION.
11 NEMA 14-50R RECEPTACLE FOR RANGE. RECEPTACLE TO BE FLUSH MOUNTED OR OTHERWISE AS REQUIRED TO
ALLOW BACK OF RANGE TO BE PLACED FLUSH AGAINST WALL BEHIND THE RANGE. INSTALL RANGE RECEPTACLE ,�X� ,uryµ,�
IN LOCATION AND ORIENTATION AS REQUIRED BY AND IN ACCORDANCE WITH THE SUPPLIED RANGE �`pN1A wiry
MANUFACTURER'S INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL VERIFY RECEPTACLE CONFIGURATION,
CIRCUIT SIZE, AND MOUNTING HEIGHT WITH DRYER MANUFACTURER PRIOR TO INSTALLATION. vTIWDRll1
12 RECEPTACLE I CIRCUIT CONNECTION TO HOOD. VERIFY EXACT LOCATION WITH CUSTOM LIVING PRIOR TO
INSTALLATION. PROVIDE DEDICATED 120V,20A,lP CIRCUIT. c KZ
73 RECEPTACLEION. CIRCUIT
PROVIDE
DISHWASHER. VERIFY EXACT LOCATION WITH CUSTOM LIVING PRIOR IK
<L
TO INSTALLATION. PROVIDE DEDICATED 12W,20.4,1PCIRCUIT. / AL
14 GARBAGE DISPOSAL. CONFIRM IF SWITCH IS TO BE INSTALLED OVER COUNTERTOP AT B2° ABOVE BACKSPIASH
TO BOTTOM OF DEVICE CHAIR SWITCH IS TO BE USED. COORDINATE EXACT REQUIREMENTS WITH CUSTOM
LIVING PRIOR TO INSTALLATION. PROVIDE DEDICATED 1201 CIRCUIT.
15 PROVIDE THE FOLLOWING FOR LOW VOLTAGE EQUIPMENT: "
(1) 720V,20A,1P CIRCUIT FOR ALARM PANEL.
(2)120V,20A,1 P CIRC JI I5 AT EQUIPMENT RACK. OISTRIEWCED OR M39UNEO TO A TURN PARTY WITHOUT
(1)120V,20A,l P CIRCUIT FOR LOW VOLTAGE PANEL
CONFIRM ALL QUANTITIES AND LOCATIONS WITH OWNER PRIOR TO ROUGH -IN. PERMITTED
16 RECEPTACLE FOR REFRIGERATOR/FREEZER. PROVIDE DEDICATED 12DV,20A,IPCRCUIT. _
17 RECEPTACLE I CIRCUIT CONNECTION TO MICROWAVE. VERIFY EXACT LOCATION WITH CUSTOM LIVING PRIOR TO ARCHITECT
INSTALLATION. PROVIDE DEDICATED 120V,20A1P CIRCUIT. BLACKLINE
18 RECEPTACLE/ TELECOM FOR WALL MOUNTED TELEVISION INSTALLED INSIDE RECESSED FLAT PANEL DISPLAY
BOX. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH CUSTOM LIVING. CIRCUIT SHALL BE INDIANAPOLIS INDIAW °
SEPARATE FROM MECHANICALS AND APPLIANCES.
19 FLUSH MOUNTED ELECTRICAL PANEL. INSTALLATION SHALL MAINTAIN ANY FIRE RATING OF WALL. REFER TO
ELECTRICAL RISER DIAGRAM FOR ADDITIONAL INFORMATION. M.E.P.
20 RECEPTACLE IN CEILING FOR GARAGE DOOR OPENER. OPENER AND ASSOCIATED DEVICES PROVIDED BY GENESIS ENGINEERING GROUP
OTHERS. PROVIDE DEDICATED 120V,20A,IP CIRCUIT. 91 NOUN MAIN WOURT WON Eoo
21 EXHAUSTFAN. VERY EXACT LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION. CONNECT TO 120V,21A,IP rams ER,NG CON
317 GFCI PROTECTED CIRCUIT.
22 2P460A, 240V NEW SIR FUSIBLE DISCONNECT SWITCH. FUSE THE DISCONNECT SWITCH PER EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS. STRUCTURAL
23 RECEPTACLE FOR WASHER. PROVIDE DEDICATED 120V,20A,1P CIRCUIT. SCHWARZ ENGINEERING GROUP
24 NEMA 14-30R RECEPTACLE FOR CLOTHES DRYER. CONTRACTOR SHALL VERIFY RECEPTACLE CONFIGURATION, A A AoC HUNIRCRIC COM
CIRCUIT SIZE, AND MOUNTING HEIGHT WITH DRYER MANUFACTURER PRIOR TO INSTALLATION.
25 BATHROOM RECEPTACLE. CONFIRM EXACT LOCATION WITH CUSTOM LIVING PRIOR TO ROUGH -IN. PROVIDE
DEDICATED 120V,20A,IP CIRCUI.
26 2P30A, 240V FUSIBLE DISCONNECT FUSED PER LIFT MANUFACTURER'S RECOMMENDATIONS. DISCONNECT
SHALL BE LOCKABLE WITH INTERLOCKING COVER AND AUXILIARY CONTACT. PROVIDE CONNECTION TO LIFT
EQUIPMENT AS REQUIRED. COORDINATE EQUIPMENT LOCATION WITH LIFT SUPPLIER. CONNECT TO SHUNT TRIP y
BREAKER IN UNIT PANEL.
27 2Pd0A, 240V FUSIBLE DISCONNECT FUSED PER LIFT MANUFACTURERS RECOMMENDATIONS. PROVIDE Z
CONNECTION TO LIFT LIGHTING AND CONTROL AS REQUIRED. COORDINATE EQUIPMENT LOCATION WITH LIFT
SUPPLIER. J
23 WATER HEATER. PROVIDE DED ICATED 12DV,20A,1P CIRCUIT. PROVIDE TOGGLE SWITCH DISCONNECT.
29 SUMPPUMP. PROVIDE(2)DEDICATED 120V,2UClP CIRCUITS TOA SPLIT WIRE RECEPTACLE. PROVIDE2-POLE
TOGGLE SWITCH DISCONNECT.
31 SMOKE DETECTOR SHALL BE STAND-ALONE PHOTOELECTRIC TYPE WITH 120V WITH BATTERY BACKUP. y�
DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED TOGETHER SO THAT ALL DETECTORS ALARM IN THE O
UNIT,
32 SMOKE DETECTOR SHALL BE COMBINATION STAND-ALONE COMBINATION PHOTOELECTRIC AND CARBON O
MONOXIDE TYPE WITH 120V WITH BATTERY BACKUP. DETECTORS WITHIN EACH UNIT SHALL BE
INTERCONNECTED TOGETHER SO THAT ALL DETECTORS ALARM IN THE UNIT. J
33 HEAT DETECTOR INSTALLED AT TOP OF LIFT SHAFT. COORDINATE LOCATION WITH LIFT SUPPLIER. LL
34 SMOKE DETECTOR INSTALLED AT TOP OF LIFT SHAFT. COORDINATE LOCATION WITH LIFT SUPPLIER.
35 TELEPHONE CONNECTION TO ELEVATOR CONTROLLER. PROVIDE (2) CATSE CABLES IN IN CONDUIT FROM
CONTROLLER TO UNIT LOW VOLTAGE PANEL. N
36 PROVIDE FIRE ALARM ADDRESSABLE RELAY FOR LIFT. RELAY SHALL SHUNT -TRIP LIFT CIRCUIT BREAKER TO aI
SHUTDOWN LIFT PRIOR TO SPRINKLER SYSTEM RELEASE. INTERLOCK LIFT WITH FIRE ALARM SYSTEM AS
REQUIRED. PROVIDE CONTROL WIRING IN CONDUITS AS REQUIRED
37 HALF -SWITCHED RECEPTACLE. SWITCHED HAVE CONTROLLED BY ELECTRONIC EQUIPMENT PROVIDED UNDER LL
PREMIER SYSTEM. VERIFY CONTROL AND WIRING WITH PREMIER ELECTRONIC LIFESTYLES. Q
30 CONNECT ALL EXTERIOR ROOF DECK LIGHTING FIXTURES TO DEDICATED GFCI-PROTECTED 120V@108.I P CIRCUIT.
39 PROVIDE FUSIBLE TOGGLE SWITCH FOR FURNACE POWER CIRCUIT. CONNECT CIRCUIT TO FURNACE THROUGH Z
FUSEDSWITCH. FUSE THE SWITCH AS RECOMMENDED BY FURNACE MANUFACTURERS INSTALLATION
INSTRUCTIONS. COORDINATE LOCATION OF SWITCH WITH MECHANICAL CONTRACTOR AND FURNACE
INSTALLATION INSTRUCTIONS. FiNw
Z
W
W c)
Z
Q Q N Z
d
m N o
J w N
Q c La
Q Z O U
c i 3 ED rn
0 c IZ
Y '10 @
FEMm M
U Will 06
W On O O
J +.n C C
W J
NNINNINNIN
DRAWN: CHECKED'.
JAW JAW
REVNIIXI WN
PREMIER LUXURY ELECTRONIC LIFESTYLES CUSTOM LIVING
JASON BARTH TOM LAllARA
OFFICE: 317.2817451 OFFICE: 317.289.5990
JASON.B@PREMIER-GROUP.COM TOM@ CUSTOM LIVINGUSA.COM
NOTES:
1. CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE LIGHTING FIXTURES, LIGHTING CONTROL, ALL
OTHER LIGHTING REQUIREMENTS, LOW VOLTAGE EQUIPMENT, LOW VOLTAGE DEVICES, WIRING AND ALL
OTHER LOW VOLTAGE REQUIREMENTS WITH PREIMIER AND CUSTOM LIVING PRIOR TO INSTALLATION. Motion and Main Brownstone
CONTRACTOR SHALL INCLUDE ALL MATERIAL AND LABOR NECESSARYTO COMPLETE INSTALLATION IN Interior Remodel - Units 90,
ACCORDANCE WITH REQUIREMENTS WHETHERTHEY ARESHOWN OR NOTSHOWN ON THEDRAWINGS.THE 60,70,50
REQUIREMENTS SHALL TAKE PRECEDENCE OVER THE DRAWINGS.
111112019
2. ALL ELECTRICAL ROUGH -INS SHALL BE INSTALLED PRIOR TO ANY WIRE INSTALLATION FOR OWNER WALK
THROUGH AND SIGN OFF.
® E70.1