�1 THIRD FLOOR LIGHTING PLAN -LOT 70
11I = 1'EC
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cannel (�
�VT�37'\DNtiYAAML
DATE: \ 02/12/19
UI
PROVIDE CONNECTION
TO n10JECTON
SCREEN AS REQUIRED.
MASTER BEDROOM
303
BATH
CABINET
PROVIDE DEDICATED 2401,111 a
CIRCUIT TO HEATED FLOOR TILE
SYSTEM. COORDINATE 1
INSTALLATIONWRHPROVIDER.
MASTERCLOSET
301
HALL
00
�1 THIRD FLOOR POWER PLAN - LOT 70
11I = 1'EC
MST WIC
0d
SIC (DLR
MASTER BEDROOM
303
(DIG Q® OLN
J�/ ®wAP
msT Mi
r — Np 30d
QSST
L —
MASTER BATH
302
2 OC° ---
SST _ -_
L—
DD
HALL
00
MASTER CLOSET
301
THIRD FLOOR SYSYEMS PLAN - LOT 70
1'-0"
32 ®o cO
a
PLAN NOTES
(NOT ALL NOTES MAYBE USED ON THIS SHEET)
1 DO NOT ROUTE ANY WIRING,PIPING, DUCTWORK, ETC., THROUGH LIFT SHAFT.
2 INSTALL LIGHT FIXTURE ABOVE VANITY MIRROR AT HEIGHT DETERMINED BY CUSTOM LIVING.
3 SURFACE MOUNT I SUSPEND LIGHT FIXTURE TO HEIGHT DETERMI NED BY CUSTOM LIVING.
4 LIGHT FIXTURE(S) INSTALLED IN CASEWORK. COORDINATE LOCATION WITH CUSTOM LIVING PRIOR TO
INSTALLATION.
5 INSTALL CEILING FAN CENTERED IN CEILING SPACE OF ROOM. PROVIDE U.L. LISTED CEILING FAN OUTLET KIT
RATED FOR FANS UP TO 70 POUNDS.
6 CENTER LIGHT FIXTURE WITHIN STAIRCASE CEILING SPACE.
7 LIGHT FIXTURE PROVIDED IN CORE AND SHELL PACKAGE.
8 INSTALL LIGHT FIXTURE AT HEIGHT DETERMINED BY CUSTOM LIVING.
9 CONNECT ALL LIGHTING ON THIS FLOOR TO A DEDICATED 120V,20A, 1P CIRCUIT, UNLESS OTHERWISE NOTED..
10 DEVICE(S) INSTALLED IN CASEWORK. COORDINATE LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION.
11 NEMA 1450R RECEPTACLE FOR RANGE. RECEPTACLE TO BE FLUSH MOUNTED OR OTHERWISE AS REQUIRED TO
ALLOW BACK OF RANGE TO BE PLACED FLUSH AGAINST WALL BEHIND THE RANGE. INSTALL RANGE RECEPTACLE
IN LOCATION AND ORIENTATION AS REQUIRED BY AND IN ACCORDANCE WITH THE SUPPLIED RANGE
MANUFACTURERSINSTALLATIONINSTRUCTIONS. CONTRACTOR SHALL VERIFY RECEPTACLE CONFIGURATION,
CIRCUIT SIZE, AND MOUNTING HEIGHT WITH DRYER MANUFACTURER PRIOR TO INSTALLATION.
12 RECEPTACLE I CIRCUIT CONNECTION TO HOOD. VERIFY EXACT LOCATION WITH CUSTOM LIVING PRIOR TO
INSTALLATION. PROVIDE DEDICATED 120V,20A,IP CIRCUIT.
13 RECEPTACLE I CIRCUIT CONNECTION TO DISHWASHER. VERIFY EXACT LOCATION WITH CUSTOM LIVING PRIOR
TOINSTALLATION. PROVIDE DEDICATED 120V,20A,1 P CIRCUIT.
14 GARBAGE DISPOSAL. CONFIRM IF SWITCH IS TO BE INSTALLED OVER COUNTERTOP AT R2' ABOVE BACKSPLASH
TO BOTTOM OF DEVICE OR AIR SWITCH IS TO BE USED. COORDINATE EXACT REQUIREMENTS WITH CUSTOM
LIVING PRIOR TO INSTALLATION. PROVIDE DEDICATED 120V,20A,lP CIRCUIT.
15 PROVIDE THE FOLLOWING FOR LOW VOLTAGE EQUIPMENT',
(1)120V,20A,lP CIRCUIT FOR ALARM PANEL.
(2)1201 CIRCU TS AT EQUIPMENT EACH.
(1)120V,20A,lP CIRCUIT FOR LOW VOLTAGE PANEL.
CONFIRM ALL QUANTITIES AND LOCATIONS WITH OWNER PRIOR TO ROUGH -IN.
16 RECEPTACLE FOR REFRIGERATOR/FREEZER. PROVIDE DEDICATED 120V,2OA,1P CIRCUIT.
17 RECEPTACLE I CIRCUIT CONNECTION TO MICROWAVE. VERIFY EXACT LOCATION WTIH CUSTOM LIVING PRIOR TO
INSTALLATION. PROVIDE DEDICATED 120V,2M, I CIRCUIT.
18 RECEPTACLE I TELECOM FOR WALL MOUNTED TELEVISION INSTALLED INSIDE RECESSED FLAT PANEL DISPLAY
BOX. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH CUSTOM LIVING. CIRCUIT SHALL BE
SEPARATE FROM MECHANICALS AND APPLIANCES.
19 FLUSH MOUNTED ELECTRICAL PANEL. INSTALLATION SHALL MAINTAIN ANY FIRE RATING OF WALL. REFER TO
ELECTRICAL RISER DIAGRAM FOR ADDITIONAL INFORMATION.
20 RECEPTACLE IN CEILING FOR GARAGE DOOR OPENER. OPENER AND ASSOCIATED DEVICES PROVIDED BY
OTHERS. PROVIDE DEDICATED 120V,20A,lP CIRCUIT.
21 EXHAUSTFAN. VERY EXACT LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION. CONNECT TO l20V,20g1P
GFCI PROTECTED CIRCUIT.
T2 2P50A, 240V NEW 3R FUSIBLE DISCONNECT SWITCH. FUSE THE DISCONNECT SWITCH PER EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS.
23 RECEPTACLE FOR WASHER. PROVIDE DEDICATED 120V,20A,IP CIRCUIT.
24 NEMA 14-30R RECEPTACLE FOR CLOTHES DRYER. CONTRACTOR SHALL VERIFY RECEPTACLE CONFIGURATION,
CIRCUIT SIZE, AND MOUNTING HEIGHT WITH DRYER MANUFACTURER PRIOR TO INSTALLATION.
25 BATHROOM RECEPTACLE. CONFIRM EXACT LOCATION WITH CUSTOM LIVING PRIOR TO ROUGH -IN. PROVIDE
DEDICATED 120V,2M,IP CIRCUT.
26 2P30A, 240V FUSIBLE DISCONNECT FUSED PER LIFT MANUFACTURER'S RECOMMENDATIONS. DISCONNECT
SHALL BE LOCKABLE WITH INTERLOCKING COVER AND AUXILIARY CONTACT. PROVIDE CONNECTION TO LIFT
EQUIPMENT AS REQUIRED. COORDINATE EQUIPMENT LOCATION WITH LIFT SUPPLIER. CONNECT TO SHUNT TRIP
BREAKER IN UNIT PANEL.
27 2P30A, 240V FUSIBLE DISCONNECT FUSED PER LIFT MANUFACTURERS RECOMMENDATIONS. PROVIDE
CONNECTION TO LIFT LIGHTINGAND CONTROL AS REQUIRED. COORDINATE EQUIPMENT LOCATION WITH LIFT
SUPPLIER.
28 WATER HEATER. PROVIDE DEDICATED 12DV,20AA1P CIRCUIT. PROVIDE TOGGLE SWITCH DISCONNECT.
29 SUMPPUMP. PROVIDE(2)DEDICATED 120V,20A,lP CIRCUITS TO A SPLIT WIRE RECEPTACLE. PROVIDE2-POLE
TOGGLE SWITCH DISCONNECT.
31 SMOKE DETECTOR SHALL BE STAND-ALONE PHOTOELECTRIC TYPE WITH 120V WITH BATTERYBACKUP.
DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED TOGETHER SO THAT ALL DETECTORS ALAWd IN THE
UNIT,
32 SMOKE DETECTOR SHALL BE COMBINATION STAND-ALONE COMBINATION PHOTOELECTRIC AND CARBON
MONOXIDE TYPE WITH 120V WITH BATTERYBACKUP. DETECTORS WITHIN EACH UNIT SHALL BE
INTERCONNECTED TOGETHER SO THAT ALL DETECTORS ALARM IN THE UNIT.
33 HEAT DETECTOR INSTALLED AT TOP OF LIFT SHAFT. COORDINATE LOCATION WITH LIFT SUPPLIER.
34 SMOKE DETECTOR INSTALLED AT TOP OF LIFT SHAFT. COORDINATE LOCATION WITH LIFT SUPPLIER.
35 TELEPHONE CONNECTION TO ELEVATOR CONTROLLER. PROVIDE (2) CAT5E CABLES IN I' CONDUIT FROM
CONTROLLER TO UNIT LOW VOLTAGE PANEL.
36 PROVIDE FI RE ALARM ADDRESSABLE RELAY FOR Ll FT. RELAY SHALL SHUNT-TRI P Ll FT CIRCU IT BREAKER TO
SHUTDOWN LIFT PRIOR TO SPRINKLER SYSTEM RELEASE. INTERLOCK LIFT WITH FIRE ALARM SYSTEM AS
REQUIRED. PROVIDE CONTROL WIRING IN CONDUITS AS REQUIRED
37 HALF -SWITCHED RECEPTACLE. SWITCHED HAVE CONTROLLED BY ELECTRONIC EQUIPMENT PROVIDED UNDER
PREMIER SYSTEM. VERIFY CONTROL AND WIRING WITH PREMIER ELECTRONIC LIFESTYLES.
38 CONNECT ALL EXTERIOR ROOF DECK LIGHTING FIXTURES TO DEDICATED GFCI-PROTECTED 120Vp07V1 P CIRCUIT.
39 PROVIDE FUSIBLE TOGGLE SWITCH FOR FURNACE POWER CIRCUIT. CONNECT CIRCUIT TO FURNACE THROUGH
FUSEDSWITCH. FUSE THE SWITCH AS RECOMMENDED BY FURNACE MANUFACTURERS INSTALLATION
INSTRUCTIONS. COORDINATE LOCATION OF SWITCH WITH MECHANICAL CONTRACTOR AND FURNACE
INSTALLATION INSTRUCTIONS.
PREMIER LUXURY ELECTRONIC LIFESTYLES CUSTOM LIVING
JASON BARTH TOM LAllARA
OFFICE: 317 281 7451 OFFICE: 317.289.5990
NOTES:
1. CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE LIGHTING FIXTURES, LIGHTING CONTROL, ALL
OTHER LIGHTING REQUIREMENTS, LOW VOLTAGE EQUIPMENT, LOW VOLTAGE DEVICES, WIRING AND ALL
OTHER LOW VOLTAGE REQUIREMENTS WITH PREIMIER AND CUSTOM LIVING PRIOR TO INSTALLATION,
CONTRACTOR SHALL INCLUDE ALL MATERIAL AND LABOR NECESSARY TO COMPLETE INSTALLATION IN
ACCORDANCE WITH REQUIREMENTS WHETHER THEY ARE SHOWN OR NOT SHOWN ON THE DRAWINGS. THE
REQUIREMENTS SHALL TAKE PRECEDENCE OVERTHE DRAWINGS,
2. ALL ELECTRICAL ROUGH -INS SHALL BE INSTALLED PRIOR TO ANY WIRE INSTALLATION FOR OWNER WALK
THROUGH AND SIGN OFF,
CERTIFICATION:
p slnre os.I
PEI0708731 �`j
xd
242
AMMMMA
ARCHITECT
BLACKLIIINDIAMADUS �r
3178070
MINNINNINNIN
M.E.P.
GENESIS ENGINEERING GROUP
MMMMw
STRUCTURAL
SCHHWARZ ENGINEERING GROUP
VJ
Z
Q
J
Na
1.6
0
0
J
LL
w
z
_
w
C
n
d
Z
c
o
ELU
J
LU
�
N
�
R
a
Z
o
U
DO
U)
0
H
m
U
°a
06
LU
0
0
J
0
0
LU
MMMMMA
DRAWN'.
CHECKED'.
JAW
JAW
N
REVISION
ON,
Monon and Main Brownstone
Interior Remodel — Units 90,
60,70,50
111112019
AMMMMA
(4 E70-3