Loading...
HomeMy WebLinkAboutE70.3 Elec 3rd FlrUAl _—� Al _ —� Al Fib 0' 'O' )0 / 1 I B2 MAST ERBEDROOM I \ 303 � 1 AD I Fib O _ / i Npp AUTOMATED i OUTLET �11 MEDIMMER FOR 1 ME Al I / e DFI2O I � pp 11 MST WIC .a5 A2 VA2�A Al \ � / / OF15 Q A2 d¢ `� I I / / A� _ MASTERCLOSET Al 301 q A22 7 A2 -0/ \ A2 � \ Al / \ �1 THIRD FLOOR LIGHTING PLAN -LOT 70 11I = 1'EC RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel (� �VT�37'\DNtiYAAML DATE: \ 02/12/19 UI PROVIDE CONNECTION TO n10JECTON SCREEN AS REQUIRED. MASTER BEDROOM 303 BATH CABINET PROVIDE DEDICATED 2401,111 a CIRCUIT TO HEATED FLOOR TILE SYSTEM. COORDINATE 1 INSTALLATIONWRHPROVIDER. MASTERCLOSET 301 HALL 00 �1 THIRD FLOOR POWER PLAN - LOT 70 11I = 1'EC MST WIC 0d SIC (DLR MASTER BEDROOM 303 (DIG Q® OLN J�/ ®wAP msT Mi r — Np 30d QSST L — MASTER BATH 302 2 OC° --- SST _ -_ L— DD HALL 00 MASTER CLOSET 301 THIRD FLOOR SYSYEMS PLAN - LOT 70 1'-0" 32 ®o cO a PLAN NOTES (NOT ALL NOTES MAYBE USED ON THIS SHEET) 1 DO NOT ROUTE ANY WIRING,PIPING, DUCTWORK, ETC., THROUGH LIFT SHAFT. 2 INSTALL LIGHT FIXTURE ABOVE VANITY MIRROR AT HEIGHT DETERMINED BY CUSTOM LIVING. 3 SURFACE MOUNT I SUSPEND LIGHT FIXTURE TO HEIGHT DETERMI NED BY CUSTOM LIVING. 4 LIGHT FIXTURE(S) INSTALLED IN CASEWORK. COORDINATE LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION. 5 INSTALL CEILING FAN CENTERED IN CEILING SPACE OF ROOM. PROVIDE U.L. LISTED CEILING FAN OUTLET KIT RATED FOR FANS UP TO 70 POUNDS. 6 CENTER LIGHT FIXTURE WITHIN STAIRCASE CEILING SPACE. 7 LIGHT FIXTURE PROVIDED IN CORE AND SHELL PACKAGE. 8 INSTALL LIGHT FIXTURE AT HEIGHT DETERMINED BY CUSTOM LIVING. 9 CONNECT ALL LIGHTING ON THIS FLOOR TO A DEDICATED 120V,20A, 1P CIRCUIT, UNLESS OTHERWISE NOTED.. 10 DEVICE(S) INSTALLED IN CASEWORK. COORDINATE LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION. 11 NEMA 1450R RECEPTACLE FOR RANGE. RECEPTACLE TO BE FLUSH MOUNTED OR OTHERWISE AS REQUIRED TO ALLOW BACK OF RANGE TO BE PLACED FLUSH AGAINST WALL BEHIND THE RANGE. INSTALL RANGE RECEPTACLE IN LOCATION AND ORIENTATION AS REQUIRED BY AND IN ACCORDANCE WITH THE SUPPLIED RANGE MANUFACTURERSINSTALLATIONINSTRUCTIONS. CONTRACTOR SHALL VERIFY RECEPTACLE CONFIGURATION, CIRCUIT SIZE, AND MOUNTING HEIGHT WITH DRYER MANUFACTURER PRIOR TO INSTALLATION. 12 RECEPTACLE I CIRCUIT CONNECTION TO HOOD. VERIFY EXACT LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION. PROVIDE DEDICATED 120V,20A,IP CIRCUIT. 13 RECEPTACLE I CIRCUIT CONNECTION TO DISHWASHER. VERIFY EXACT LOCATION WITH CUSTOM LIVING PRIOR TOINSTALLATION. PROVIDE DEDICATED 120V,20A,1 P CIRCUIT. 14 GARBAGE DISPOSAL. CONFIRM IF SWITCH IS TO BE INSTALLED OVER COUNTERTOP AT R2' ABOVE BACKSPLASH TO BOTTOM OF DEVICE OR AIR SWITCH IS TO BE USED. COORDINATE EXACT REQUIREMENTS WITH CUSTOM LIVING PRIOR TO INSTALLATION. PROVIDE DEDICATED 120V,20A,lP CIRCUIT. 15 PROVIDE THE FOLLOWING FOR LOW VOLTAGE EQUIPMENT', (1)120V,20A,lP CIRCUIT FOR ALARM PANEL. (2)1201 CIRCU TS AT EQUIPMENT EACH. (1)120V,20A,lP CIRCUIT FOR LOW VOLTAGE PANEL. CONFIRM ALL QUANTITIES AND LOCATIONS WITH OWNER PRIOR TO ROUGH -IN. 16 RECEPTACLE FOR REFRIGERATOR/FREEZER. PROVIDE DEDICATED 120V,2OA,1P CIRCUIT. 17 RECEPTACLE I CIRCUIT CONNECTION TO MICROWAVE. VERIFY EXACT LOCATION WTIH CUSTOM LIVING PRIOR TO INSTALLATION. PROVIDE DEDICATED 120V,2M, I CIRCUIT. 18 RECEPTACLE I TELECOM FOR WALL MOUNTED TELEVISION INSTALLED INSIDE RECESSED FLAT PANEL DISPLAY BOX. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH CUSTOM LIVING. CIRCUIT SHALL BE SEPARATE FROM MECHANICALS AND APPLIANCES. 19 FLUSH MOUNTED ELECTRICAL PANEL. INSTALLATION SHALL MAINTAIN ANY FIRE RATING OF WALL. REFER TO ELECTRICAL RISER DIAGRAM FOR ADDITIONAL INFORMATION. 20 RECEPTACLE IN CEILING FOR GARAGE DOOR OPENER. OPENER AND ASSOCIATED DEVICES PROVIDED BY OTHERS. PROVIDE DEDICATED 120V,20A,lP CIRCUIT. 21 EXHAUSTFAN. VERY EXACT LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION. CONNECT TO l20V,20g1P GFCI PROTECTED CIRCUIT. T2 2P50A, 240V NEW 3R FUSIBLE DISCONNECT SWITCH. FUSE THE DISCONNECT SWITCH PER EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. 23 RECEPTACLE FOR WASHER. PROVIDE DEDICATED 120V,20A,IP CIRCUIT. 24 NEMA 14-30R RECEPTACLE FOR CLOTHES DRYER. CONTRACTOR SHALL VERIFY RECEPTACLE CONFIGURATION, CIRCUIT SIZE, AND MOUNTING HEIGHT WITH DRYER MANUFACTURER PRIOR TO INSTALLATION. 25 BATHROOM RECEPTACLE. CONFIRM EXACT LOCATION WITH CUSTOM LIVING PRIOR TO ROUGH -IN. PROVIDE DEDICATED 120V,2M,IP CIRCUT. 26 2P30A, 240V FUSIBLE DISCONNECT FUSED PER LIFT MANUFACTURER'S RECOMMENDATIONS. DISCONNECT SHALL BE LOCKABLE WITH INTERLOCKING COVER AND AUXILIARY CONTACT. PROVIDE CONNECTION TO LIFT EQUIPMENT AS REQUIRED. COORDINATE EQUIPMENT LOCATION WITH LIFT SUPPLIER. CONNECT TO SHUNT TRIP BREAKER IN UNIT PANEL. 27 2P30A, 240V FUSIBLE DISCONNECT FUSED PER LIFT MANUFACTURERS RECOMMENDATIONS. PROVIDE CONNECTION TO LIFT LIGHTINGAND CONTROL AS REQUIRED. COORDINATE EQUIPMENT LOCATION WITH LIFT SUPPLIER. 28 WATER HEATER. PROVIDE DEDICATED 12DV,20AA1P CIRCUIT. PROVIDE TOGGLE SWITCH DISCONNECT. 29 SUMPPUMP. PROVIDE(2)DEDICATED 120V,20A,lP CIRCUITS TO A SPLIT WIRE RECEPTACLE. PROVIDE2-POLE TOGGLE SWITCH DISCONNECT. 31 SMOKE DETECTOR SHALL BE STAND-ALONE PHOTOELECTRIC TYPE WITH 120V WITH BATTERYBACKUP. DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED TOGETHER SO THAT ALL DETECTORS ALAWd IN THE UNIT, 32 SMOKE DETECTOR SHALL BE COMBINATION STAND-ALONE COMBINATION PHOTOELECTRIC AND CARBON MONOXIDE TYPE WITH 120V WITH BATTERYBACKUP. DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED TOGETHER SO THAT ALL DETECTORS ALARM IN THE UNIT. 33 HEAT DETECTOR INSTALLED AT TOP OF LIFT SHAFT. COORDINATE LOCATION WITH LIFT SUPPLIER. 34 SMOKE DETECTOR INSTALLED AT TOP OF LIFT SHAFT. COORDINATE LOCATION WITH LIFT SUPPLIER. 35 TELEPHONE CONNECTION TO ELEVATOR CONTROLLER. PROVIDE (2) CAT5E CABLES IN I' CONDUIT FROM CONTROLLER TO UNIT LOW VOLTAGE PANEL. 36 PROVIDE FI RE ALARM ADDRESSABLE RELAY FOR Ll FT. RELAY SHALL SHUNT-TRI P Ll FT CIRCU IT BREAKER TO SHUTDOWN LIFT PRIOR TO SPRINKLER SYSTEM RELEASE. INTERLOCK LIFT WITH FIRE ALARM SYSTEM AS REQUIRED. PROVIDE CONTROL WIRING IN CONDUITS AS REQUIRED 37 HALF -SWITCHED RECEPTACLE. SWITCHED HAVE CONTROLLED BY ELECTRONIC EQUIPMENT PROVIDED UNDER PREMIER SYSTEM. VERIFY CONTROL AND WIRING WITH PREMIER ELECTRONIC LIFESTYLES. 38 CONNECT ALL EXTERIOR ROOF DECK LIGHTING FIXTURES TO DEDICATED GFCI-PROTECTED 120Vp07V1 P CIRCUIT. 39 PROVIDE FUSIBLE TOGGLE SWITCH FOR FURNACE POWER CIRCUIT. CONNECT CIRCUIT TO FURNACE THROUGH FUSEDSWITCH. FUSE THE SWITCH AS RECOMMENDED BY FURNACE MANUFACTURERS INSTALLATION INSTRUCTIONS. COORDINATE LOCATION OF SWITCH WITH MECHANICAL CONTRACTOR AND FURNACE INSTALLATION INSTRUCTIONS. PREMIER LUXURY ELECTRONIC LIFESTYLES CUSTOM LIVING JASON BARTH TOM LAllARA OFFICE: 317 281 7451 OFFICE: 317.289.5990 NOTES: 1. CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE LIGHTING FIXTURES, LIGHTING CONTROL, ALL OTHER LIGHTING REQUIREMENTS, LOW VOLTAGE EQUIPMENT, LOW VOLTAGE DEVICES, WIRING AND ALL OTHER LOW VOLTAGE REQUIREMENTS WITH PREIMIER AND CUSTOM LIVING PRIOR TO INSTALLATION, CONTRACTOR SHALL INCLUDE ALL MATERIAL AND LABOR NECESSARY TO COMPLETE INSTALLATION IN ACCORDANCE WITH REQUIREMENTS WHETHER THEY ARE SHOWN OR NOT SHOWN ON THE DRAWINGS. THE REQUIREMENTS SHALL TAKE PRECEDENCE OVERTHE DRAWINGS, 2. ALL ELECTRICAL ROUGH -INS SHALL BE INSTALLED PRIOR TO ANY WIRE INSTALLATION FOR OWNER WALK THROUGH AND SIGN OFF, CERTIFICATION: p slnre os.I PEI0708731 �`j xd 242 AMMMMA ARCHITECT BLACKLIIINDIAMADUS �r 3178070 MINNINNINNIN M.E.P. GENESIS ENGINEERING GROUP MMMMw STRUCTURAL SCHHWARZ ENGINEERING GROUP VJ Z Q J Na 1.6 0 0 J LL w z _ w C n d Z c o ELU J LU � N � R a Z o U DO U) 0 H m U °a 06 LU 0 0 J 0 0 LU MMMMMA DRAWN'. CHECKED'. JAW JAW N REVISION ON, Monon and Main Brownstone Interior Remodel — Units 90, 60,70,50 111112019 AMMMMA (4 E70-3