HomeMy WebLinkAboutM70.0 Cover SheetJ
ABBREVIATIONS AND TERMS
0
PHASE
FS
FLOOR SINK
°F
DEGREES FAHRENHEIT
FSD
FIREISMOKE DAMPER
AIE
ARCH ITECTIEN GINEER
FTR
FINNED TUBE RADIATION
ACC
AIR COOLED CONDENSER
GA
GAGE OR GUAGE
ACCU
AIR COOLED CONDENSING UNIT
GAL
GALLON
AD
AREA DRAIN, ACCESS DOOR
GC
GENERALCONTRACTOR
ADJ
ADJUSTABLE, ADJACENT
GPD
GALLONS PER DAY
AFCV
AIRFLOW CONTROL VALVE
GEN
GALLONS PER HOUR
AFF
ABOVE FINISHED FLOOR
GPM
GALLONS PER MINUTE
ARMS
AIRFLOW MEASURING STATION
HE
HEAD FT.I
AGA
AMERICAN GAS ASSOCIATION
HP
HORSEPOWER
AHU
AIR HANDLING UNIT
HPR
HIGH PRESSURE STEAM RETURN
AL
ALUMINUM
HPS
HIGH PRESSURE STEAM SUPPLY
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
HWP
HOT WATER PUMP
AO
ANALOG OUTPUT
HWR
HEATING WATER RETURN
AP
ACID PROOF, ACCESS PANEL
HAS
HEATING WATER SUPPLY
ADD
AIR PRESSURE DROP (IN AC)
HX
HEAT EXCHANGER
ARI
AIR CONDITIONING REFRIGERATION INSTITUTE
IFB
INTEGRAL FACEIBYPASS
AS
AIR SEPARATOR
LAT
LEAVING AIRTEMPERATURE (7)
ASHRAE
AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND
LPR
LOW PRESSURE STEAM RETURN
AIR CONDITIONING ENGINEERS
UPS
LOW PRESSURE STEAM SUPPLY
ASME
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
LWT
LEAVING WATER TEMPERATURE(7)
ASPE
AMERICAN SOCIETY OF PLUMBING ENGINEERS
MA
MIXED AIR
ASTM
AMERICAN SOCIETY FORTESTING AND MATERIALS
MAT
MIXED AIRTEMPERATURE(7)
ATM
ATMOSPHERE
MBH
THOUSAND BTU PER HOUR
AUTO
AUTOMATIC
MC
MECHANICAL CONTRACTOR
AWWA
AMERICAN WATER WORKS ASSOCIATION
MCA
MINIMUM CIRCUIT AMPACITY
B
BOILER
MCC
MOTOR CONTROL CENTER
BCU
BLOWER COIL UNIT
MD
MOTORIZED DAMPER
BE
BALANCE DAMPER
All
MEDIUM PRESSURE STEAM RETURN
SEE
BACK DRAFT DAMPER
MPS
MEDIUM PRESSURE STEAM SUPPLY
BHP
BRAKE HORSEPOWER ORBOIIER HORSEPOWER
NC
NOISE CRITERIA, NORMALLY CLOSED
BI
BINARY INPUT, BACKWARD INCLINED
NEC
NATIONAL ELECTRIC CODE
BOO
BOTTOM OF DUCT
NEC
NATIONAL FIRE CODE
BOP
BOTTOM OF PIPE
NFPA
NATIONAL FIRE PROTECTION ASSOCIATION
BTUH
BRITISH THERMAL UNITS PER HOUR
NO
NOT IN CONTRACT
CA
COMPRESSED AIR
NO
NORMALLY OPEN
CAP
CAPACITY
NTS
NOT TO SCALE
CAV
CONSTANT AIR VOLUME
CA
OUTSIDE AIR
CB
CATCH BASIN OR CHILLED BEAM
OAT
OUTSIDE AIR TEMPERATURE(IF)
CD
CONDENSATE DRAIN
OBD
OPPOSED BLADE DAMPER
CO2
CARBON DIOXIDE
00
OUTSIDE DIAMETER
CFM
CUBIC FEET PER MINUTE
OFICI
OWNER FURN I SHED CONTRACTOR INSTALLED
CH
CHILLER
P
PUMP
CHWP
CHILLED WATER PUMP
PC
PLUMBING CONTRACTOR
CHAIR
CHILLED WATER RETURN
PD
PRESSURE DROP
CHWS
CHILLED WATER SUPPLY
PF
PREFILTER
CO
CLEANOUT
PGW
PROPYLENE GLYCOL WATER
COMP
COMPRESSOR
PHC
PREHEAT COIL
COND
CONDENSER
PPM
PARTS PER MILLION
CONV
CONVECTOR
PRV
PRESSURE REDUCING VALVE
CP
CONDENSATE PUMP
PSI
POUNDS PER SQUARE INCH
CPD
CONDENSATE PUMP DISCHARGE
PSIA
POUNDS PER SQUARE INCH (ABSOLUTE)
OR
CONDENSER WATER RETURN
PSIG
POUNDS PER SQUARE INCH (GAUGE)
CS
CONDENSER WATER SUPPLY
PTAC
PACKAGED TERMINAL AIR CONDITIONER
CT
COOLING TOWER
RA
RETURN AIR
DUN
CABINET UNIT HEATER
RAT
RETURN AIR TEMPERATURE(7)
CWP
CONDENSER WATER PUMP
RE
RETURN FAN
9B
DECIBEL
RG
RETURN GRILLE
DO
DUAL DUCT
RH
RELATIVE HUMIDITY
DDC
DIRECT DIGITAL CONTROL
RHC
REHEAT COIL
DEG
DEGREE ('F)
RP
RADIANT PANEL
CIA
DIAMETER
RTU
ROOFTOP UNIT
DISC
DISCONNECT SWITCH
SA
SUPPLY AIR
DAN
DOMESTIC WATER HEATER
SAT
SUPPLY AIR TEMPERATURE ('F)
OWV
DRAIN, WASTE, AND VENT
SD
SUPPLY DIFFUSER
DX
DIRECT EXPANSION
SEER
SEASONAL ENERGY EFFICIENCY RATIO
EA
EXHAUST AIR
SG
SUPPLY GRILLE
EAT
ENTERING AIR TEMPERATURE(7)
SMACNA
SHEETMETAL AND AIR CONDITIONING CONTRACTORS
EC
ELECTRICAL CONTRACTOR
ASSOCIATION
ECG
EGG CRATE GRILLE
SP
STATIC PRESSURE
EDR
EQUIVALENT DIRECT RADIATION
SR
SUPPLY REG ISTER
EER
ENERG Y EF FI C IENCY RATI O
SRV
SAFETY RELIEF VALVE
EF
EXHAUST FAN
SV
STEAM VENT
EFF
EFFICIENCY
T
THERMOSTAT
EFT
ENTERING FLU ID TEMPERATURE(7)
TOG
TEMPERATURE CONTROL CONTRACTOR
EG
EXHAUST GRILLE
TD
TEMPERATURE D IFFERENCE
EMG
EXTRUDED METAL GRILLE (WELDED WIRE MESH)
TSP
TOTAL STATIC PRESSURE
EOM
END OF MAIN DRIP
TXV
THERMAL EXPANSION VALVE
ESP
EXTERNAL STATIC PRESSURE (IN AC.)
TYR
TYPICAL
ET
EXPANSION TANK
UH
UNIT HEATER
EWT
ENTERING WATER TEMPERATURE(IF)UL
UNDERWRITERS LABORATORIES
EXH
EXHAUST
VAV
VARIABLE AIR VOLUME
F
FURNACE
V0
VOLUME DAMPER
F&T
FLOAT AND THERMOSTATIC STEAM TRAP
VFC
VARIABLE FREQUENCY CONTROLLER(SAME AS VFD, VSC)
FCO
FLOOR CLEANOUT
VFD
VARIABLE FREQUENCY DRIVE (SAME AS VFC, VSC)
FCU
FAN COIL UNIT
VSC
VARIABLE SPEED CONTROLLER(SAME AS VFC, VFD)
FD
FLOOR DRAIN
WI
WITH
FM
FACTORY MUTUAL
WHO
WITHOUT
FPS
FAN POWERED TERMINAL UNIT
AS
WET BULB TEMPERATURE(7)
FPM
FEET PER MINUTE
WIFE
WATER PRESSURE DROP (FT HD)
FPS
FEET PER SECOND
WSHP
WATER SOURCE HEAT PUMP
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Calmed (�
�VT�'lmA�(aoAA�
DATE: 02/12/19
MECHANICAL DUCTWORK SYMBOLS
}SYM�BBOLy} DESCRIPTION SYMBOL DESCRIPTION
IDS MANUAL VOLUME DAMPER
90 DEGREE ELBOW WITH TURNING VANES
ED
MF IRE DAMPER WIT H ACCESS D OOR
SDI} STANDARD RADIUS ELBOW WITH CENTER RADIUS
OTHERWISE
IN TIMES WIDTH OF DUCT UNLESS
SMOKE DAMPER WITH ACCESS DOOR OTHERWISE INDICATED
CI FISDD
{I= {I
I FIREISMOKE DAMPER WITH ACCESS DOOR
FLAT OVAL SPIRAL DUCT (FIRST DIMENSION,
MO�} W X H SHOWN)
o SIDE SHOWN)
I--�� AUTOMATIC MOTOR OPERATED DAMPER
DIA'b ROUND SPIRAL DUCT
W"XH" RECTANGULAR DUCT (FIRST DIMENSION
SIDE SHOWN)
DUCTTURNED UP (SOLID LINES)
T
SPINFITTINGIN
WITH CONNECTION
VOLUME DAMPER AND
FLEXIBLE DUCT CONNECTION
DUCT TURNED DOWN (DASHED LINES) �a
U CONICAL FITTING
WX H" DIA"e
® SQUARETOROUND TRANSITION
PLAN VIEW
GRILL
G CONNECTION TERIDIFFUSER .eq
CONNECTION IIJII 7 TYPICALTERMINAL UNIT WITH REHEAT COIL
SECTION
WITHFLEX DUCT 90 DEGREE TEE (ROUND OR FLAT OVAL ONLY)
SIDEWALL SUPPLY, RETURN OR
EXHAUST
EXHAUST GRILLE
46 DEGREE LATERAL (ROUND OR FLAT OVAL ONLY)
SUPPLY, RETURN, OR EXHAUST ® INSULATED METAL PANEL
SLOT DIFFUSER
® DIFFUSER (NO AIRFLOW IN SHADED DIRECTION)
BEVELED ENTRY FITTING
�I�Q�I�� ® ® SUPPLY DIFFUSER OR SUPPLY GRILLE
I�� FLEXIBLE CONNECTION
RORD
RETURN GRILLE
R(RISE), D(DROP)
AD ACCESS DOOR ® ® EXHAUST GRILLE
FECHANICAL VALVE
AND FITTING SYMBOLS
SYMBOL
DESCRIPTION
PLAN VIEW
DETAILVIEW
—6-
CALIBRATED BALANCING VALVE
®
PIPING FLEXIBLE CONNECTION
I —PR
--0
PIPE TURNED UP (UNLESS NOTED
OTHERWISE(
®
i
PIPE TURNED DOWN
PIPE OUT TOP
PIPE OUT BOTTOM
I�
THREADEDIFLANGED CAP
m
CONCENTRIC REDUCER
ECCENTRIC REDUCER
CHECK VALVE
m
�H
UNION
GATE VALVE
EMI-3
BALLVALVE
BUTTERFLY VALVE
0#3
GLOBE VALVE
TEMPERATURE CONTROL
2 WAY MODULATING VALVE
EAl
—41l--
TEMPERATURE CONTROL
2 WAY 2 POSITION VALVE
L
TEMPERATURE CONTROL
3 WAY MODULATING VALVE
L
TEMPERATURE CONTROL 3 WAY
2 POSITION VALVE
ONEILI
SAFETY RELIEF VALVE
STRAINER
-0N
FLOW METER
®
FLOOR DRAIN
MANUAL AIR VENT
AUTOMATIC AIR VENT
WATER PRESSURE
REDU BIN GIREGU LATIN G VALVE
PRESSURE AND
TEMPERATURE PLUG
THERMOMETER
IP=PRES VWACT=TEMP) GAUGE
SENSOR (i=TEMP H=HUMIDITY)
CLEANOUT
—o-
STEAM TRAP
VACUUM BREAKER
HVAC PIPING SYMBOLS
HAS HEATING WATER SUPPLY
HAIR
HEATING WATER RETURN
—CHWS—
CHILLED WATER SUPPLY
—CHWR—
CHILLED WATER RETURN
C$
CONDENSER WATER SUPPLY
OR
CONDENSER WATER RETURN
CPD
CONDENSATE PUMP DISCHARGE
CD
CONDENSATE & EQUIPMENT DRAIN
DIRECTION OF PIPE SLOPE (DOWN)
LINE SYMBOLS
— — SCREENED LINES INDICATE EXISTING TO REMAIN
---- HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED
HEAVY CONTINUOUS LINES INDICATE NEW WORK
I I ■
III III
LV
Mi
OCERTIFICATION:
W
I�
J��y,�'�Y
nrgosi
p
OENoh�x�"2 ¢
(
s a
`aaaaaaaa�AwiAlm
■AUWFMMATIOMCMTAMEDIUMISDOCUMUTIS
COMERE0 HOME BOTH CONFITEMnALANO
STIONAROAMOSTAUNOTRECORED REPRODUCER
Z
OASTRRURO OR AM9RUIR TO A MAT PARTY WITHOUT
PRIOR $Aii
AMaOu �MOM W ITIOEooc111ENTSiSxo1
O
ARCHITECT
QBLACKEN
ININAMPOLi o�.
Ww
NNNNI
�/ )
M.E.P.
GENESIS ENGINEERING GROUP
91 SOUTH MEET WON 'oo
'o e`m"sor;ro"xivw'ocou
W
NNNNI
STRUCTURAL
ENGINEERING GROUP
x c
ON
MSCHWARZ
W
see
Z
N
``
z
/
5aFEET
)
W/
Z
m
0
a
z
J
/
W
CO Lu
z
M
■ • •
LU a z
_
(n
M
DO O E
J w
■.�.
Q z 3
V z o
Do U)
z 0 C IZ
0
Q .7
m � �
2
ZCD
9a 06
n O o
C C
Q
cW
J
DRAWN'. CHECKED'.
Author Checker
REVISION Di
MO
CW
G
V,
J
Motion and Main Brownstone
Interior Remodel - Units 90,
J
60,70,50
Q11111a019
M 70=0