HomeMy WebLinkAboutM70.2 MechanicalMASTER CLOSET
SR1-m9
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cameel (�
�VT�x2'�D*tiYWML
DATE: \ 02/12/19
SR1 150 SR1-75
MASTER BEDROOM
MST WIC
SRi-75
LIFT
75
I I SRI-75
I
B.' --
n cu o
ROOF DECK
ACCU-2-70
FSR1-100
FSR1-100
HALL
I
13
BEDROOM
LIFT
I
T�Ezm
GUEST BATH
5
6 //30
6
SR1-60
--t`
Ii
WIC
R P.� F 24' a; ;
I MECH -so EFEF=70
THIRD FLOOR MECHANICAL PLAN -LOT 70 �1 FOURTH FLOOR MECHANICAL PLAN - LOT 70
114° , 1-0�� 114" , � �-0��
v
7
PLAN NOTES
(ALL NOTES MAY NOT BE USED ON THIS SHEET)
1 GAS FLUE B COMBUSTION AIR UP.
2 12k4' UP TO SUPPLY REGISTER IN FLOOR ABOVE.
3 12'k4' UP TO TOE KICK SUPPLY REGISTER )BY OTHERS) IN CABINET ABOVE. COORDINATE LOCATION WITH
FURNITURE PLAN.
4 12k6'DUCT UP TO SUPPLY REGISTER IN FLOOR ABOVE.
5 12'x4' SUPPLY FROM BELOW TO TOE KICK SUPPLY REGISTER )BY OTHERS) IN CABINET ON THIS FLOOR.
COORDINATE LOCATION WITH FURNITURE PLAN.
6 410 EXHAUST DOWN.
7 GAS FLUE B COMBUSTION AIR INTAKE THROUGH WALL. TERMINATE WITH CONCENTRIC VENT KIT.
8 4'0 EXHAUST UP,
9 KITCHEN HOOD EXHAUST THROUGH WALL. TERMI NATE WITH EXHAUST LOUVER SIZE D FOR MI NI MUM 700 FTIMIN
THROUGH OPENING.
10 KITCHEN VENT HOOD BY OTHERS. DUCT CONNECTION BY MC. DUCT SHALL BE APPROPRIATE FOR
GREASE -LADEN VAPORS.
11 4'0 DRYERVENT THROUGH WALL. TERMINATE WITH WALL CAP.
12 Ere DRYER VENT DOWN TO DRYER.
13 GAS FLUE& COMBUSTION AIR INTAKE UP THROUGH ROOF. TERMINATE WITH CONCENTRIC VENT KIT.
15 FIREPLACE VENT DUCT DOWN. VERIFY DUCT CONNECTION SIZE AND LOCATION WITH MANUFACTURER.
16 FIREPLACE VENT THROUGH WALL. TERMINATE WITH WALL CAP.
17 GAS FLUE AND COMBUSTION AIR DOWN.
18 4"0 EXHAUST DUCT FROM THIRD FLOOR, TRANSITION TO Vx3', UP IN WALL TO EXHAUST GRILLE.
19 AV DRYER VENT DOWN TO SECOND FLOOR CEI LING SPACE BELOW.
ID 4'0 DRYER VENT DUCT UP TO DRYER ON THIRD FLOOR.
?
I.
I III III
CERTIFICATION:uryµ��
g9'�\PM1A. y,�'�Y
#� cs�nrq osi
PE10708732 �jIS
IS xd
fAww pl�
ALL INFORMATION CONTAINED IN HIS DOCUMENT 15
CONSIDERED TO BE ROT" CONFIDENTIAL AND
PROPRIETARY INTELLECTUAL PROPERTY UP BACKING
STUDIO AND SHALL NOT BE EDGED REPRODUCED
PRIOR W AFTER CONSENT OF PIASTRE STUDIO
UNAUTHORIZED USE OF THESE DOCUMENTS 16 NOT
PERMITTED
aaaaaaaa
ARCHITECT
BLAOKLINnEEr
wiiiiiiiiiw
M.E.P.
GENESIS ENGINEERING GROUP
91 SOUTH MAIN STRE IT SUITE 200
VERSATILE INUATT
GENESIS ENGINEERING CON
STRUCTURAL
SCHWARZ ENGINEERING GROUP
5133
v!
Z
J
Na
1.6
O
J
L.L
2
H
0
LL
Z
Q
o W
U
z
= LU z
U) O
J w
V Z O
m U)
Z 0 c c
Q m a6
ad wd
(� CD c c
rn O o
LU c c
J0
DRAWN. CHECKED.
Author Checker
TV RECITARSIN USED,
Monon and Main Brownstone
Interior Remodel — Units 90,
60,70,50
111112019
® M 70.2