MECHANICAL
AND PLUMBING ABBREVIATIONS
ABBREV.
DESCRIPTION
ABBREV. DESCRIPTION
ABBREV.
DESCRIPTION
AIE
ARCHITECT AND EN GI NEE R
FHC
F I RE H OSE CABINET
OC
ON CENTER
AC OR AGO
AIR CONDITIONING UNIT OR AIR COMPRESSOR
FIN
FINISH
00
OUTS IDE DIAMETER
ACCU
AIR COOLED CONDENSING UNIT
FLA
FULL LOAD AMPS
OFCI
OWNER FURNISHEDICONTRACTOR INSTALLED
ADD
AIR CONDITIONING CONDENSATE DRAIN
FUR
FLOOR
OFOI
OWNER FURNISHEDIOWNER INSTALLED
AD
ACCESS DOOR
FOOT
FUEL OIL DAY TANK
OM
OXYGEN MANIFOLD
ADJ
ADJUSTABLE OR ADJACENT
FOP
FUEL OIL PUMP
OPER
OPERATOR
AFCV
AIRFLOW CONTROLVALVE
FOR
FUEL OIL RETURN
GOING
OPENING
ACE
ABOVE FINISHED FLOOR
FOS
FUEL OIL SUPPLY
OSD
OPEN SITE DRAIN
ARMS
AIR FLOW MEASURING STATION
COST
FUEL OIL STORAGE TANK
AHU
AIR HANDLING UNIT
FOV
FUEL OIL VENT
P
PUMP, PNEUMATIC OR PRESSURE
APD
AIR PRESSURE DROP
FP
FIRE PROTECTION
PC
PLUMBING CONTRACTOR
APPROX
APPROXIMATE
FPB
FAN POWERED BOX
PO
PRESSURE DROP OR PERFORATED DIFFUSER
AR
AIR RECEIVER
FPC
FIRE PROTECTION CONTRACTOR
PE
PNEUMATIC ELECTRIC
ARCH
ARCHITECT
FPM
FEET PER MINUTE
OF
PREFILTERS
AS
AIR SEPARATOR
FPS
FEET PER SECOND
PG
PROPYLENE GLYCOL
ATM
ATMOSPHERE
FAST
FIRE PROTECTION STORAGETANK
PHC
PREHEAT COIL
AV
ACIDVENT
FS
FLOW SWITCH
FIN
POST INDICATOR VALVE
AVMS
AIR VOLUME MEASURING STATION
FT
FEET OR FLASH TANK
PLT
PLASTER TRAP
AW
ACID WASTE
FTG
FOOTING OR FITTING
POC
POINT OF CONNECTION
FTR
FIN TUBE RADIATION
PPH
POUNDS PERHOUR
B
BOILER
PPM
PARTS PER MILLION
BCU
BLOWER COILUNIT
G
GAS,NATURAL
PRO
PRESSURE RELIEF DOOR
BOO
BACKDRAFTDAMPER
GA
GAUGE
PREFAB
PREFABRICATED
BHP
BRAKE HORSEPOWER
GAL
GALLON
PEES
PRESSURE
BI
BACKWARD INCLINED
CALM
GALVANIZED
PRV
PRESSURE REDUCING VALVE
BLDG
BUILDING
GC
GENERAL CONTRACTOR
PSI
POUNDS PER SQUARE INCH
BOT
BOTTOM
GH
GRAVITY HOOD
PSIG
POUNDS PER SQUARE INCH GAUGE
BE
BRINE PUMP
GPH
GALLONS PER HOUR
PVC
POLYVINYL CHLORIDE
BST
BULK SALT STORAGE
GPM
GALLONS PER MINUTE
BTU
BRITISH THERMALUNIT
GV
GAS NATURALVENT
RA
RETURN AIR OR RELIEF AIR
BTUH
BTU PER HOUR
RAD
RADIATED
H
HUMIDIFIER, HUMIDITY OR HEIGHT
RAT
RETURN AIR TEMPERATURE
CA
COMPRESSED AIR
HC
HEATING COIL
FIR
REHEAT
CAP
CAPACITY
HCP
HEATING COIL PUMP (HOT WATER)
RD
ROOF DRAIN
CAV
CONSTANT AIR VOLUME
HO
HEAD
REC
RECEIVER
CC
COOLING COIL
HE
HEAT EXCHANGER
RECIR
RECIRCULATING
CCP
COOLING COIL PUMP
HGT
HEIGHT
REF
REFRIGERATOR
COS
CONDENSATE PUMP DISCHARGE
HO
HUB OUTLET
RE
RETURN AIR FAN
CENTRIF
CENTRIFUGAL
HOA
HAND -OFF -AUTOMATIC
RG
RETURN GRILLE
CFM
CUBIC FEET PER MINUTE
HORZ
HORIZONTAL
PH
RELIEF HOOD OR RELATIVE HUMIDITY
CFOI
CONTRACTOR FURNISHEDIOWNER INSTALLED
HOSE
HOSPITAL
END
REHEAT COIL
CH
CHILLER
HE
HORSEPOWER OR HEATPUMP
RLA
RUNNING LOAD AMPS
Cl
CASTIRON
HER
HIGH PRESSURE CONDENSATE RETURN
RM
ROOM
CO
CLEAN OUT
HP$
HIGH PRESSURE STEAM
ROM
REVERSE OSMOSIS VENT
CO2
CARBON DIOXIDE
HR
HOUR
ROP
REVERSE OSMOSIS PUMP
COL
COLUMN
HRC
HEAT RECOVERY COIL
ROST
REVERSE OSMOSIS STORAGE TANK
COM
CARBON DIOXIDE MANIFOLD
HTR
HEATER
RP
RADIANT PANELS
COMP
COMPRESSOR
HVAC
HEATING, VENTILATION AND AIR CONDITIONING
RPG
RETURN PERFORATED GRILLE
CONC
CONCRETE
HIM
DOMESTIC HOT WATER
RPM
REVOLUTIONS PER MINUTE
CONN
CONNECTION
HAD
DOMESTIC HOT WATER RECIRC
RPZ
REDUCED PRESSURE BACKFLOW
CONST
CONSTRUCTION
HWCP
HOT WATER CIRCULATING PUMP
REDID
REQUIRED
CONT
CONTINUOUS
HAS
HEATING HOT WATER PUMP
RV
ROOF VENTILATOR
CP
CONDENSATE PUMP
HAIR
HEATING HOT WATER RETURN
CPO
CONDENSATE PUMP DISCHARGE
HAS
HEATING HOT WATER SUPPLY
S
SANITARY OR SEWER
OUR
CABINET UNIT HEATER
HX
HEAT EXCHANGER
SA
SUPPLY AIR OR SOUND ATTENUATOR
CV
CENTRAL VACUUM
HZ
HERTZ
SB
STEAM BOILER
CW
COLD WATER
SC
STEAM COIL
CAM
COLD WATER MAKE-UP
IA
INSTRUMENT AIR
$CC
STEAM CONDENSATE COOLER
CAP
CHILLED WATER PUMP
LAC
INSTRUMENT AIR COMPRESSOR
SCCH
SUBCOOLED CHILLER
CAR
CHILLED WATER RETURN
LAD
INSTRUMENT AIR DRYER, EQAD
SCFM
STANDARD CUBIC FEET PER MINUTE
CAS
CHILLED WATER SUPPLY
ID
INSIDE DIAMETER OR DIMENSION
SCH
SCHEDULE
IFB
INTEGRAL FACE AND BYPASS
SCW
SOFT COLD WATER (DOMESTIC)
D
DIFFUSER OR DAMPER
IHOM
IN-HOUSE OXYGEN MANIFOLD
ED
SUPPLY DIFFUSER OR SMOKE DAMPER
DB
DECIBELS OR DRY BULB
IN
INCHES
SEC
SECTION
DC
DUCT COIL
INCL
INCLUDE
SENS
SENSIBLE
DCV
DOUBLE CHECK VALVE
WELL
INSULATED
SEP
SEWAGE EJECTOR PUMP
DCWBP
DOMESTIC COLD WATER BOOSTER PUMP
INT
INTERIOR
SC
SUPPLY AIR FAN
DD
DUALDUCT
INV
INVERT
SG
SUPPLY GRILLE
DOC
DIRECT DIGITAL CONTROL
I.P.S.
INTERNATIONAL PIPE SIZING
BHT
SHEET
DE
DEAERATOR
ISOL
ISOLATION
SHW
SOFT HOT WATER
DEFL
DEFLECTION
SK
SINK
DEG
DEGREE
JT
JOINT
SMBH
SENSIBLE MEN
DEPT
DEPARTMENT
SKID
SHEET METAL CONTRACTOR
DHWBP
DOMESTIC HOT WATER BOOSTER PUMP
KAIC
SHORT CIRCUIT RATING
SO
STATIC PRESSURE OR STORM PUMP
DI
DEIONIZED WATER
KEC
KITCHEN EQUIPMENT CONTRACTOR
SPEC
SPECIFICATIONS
CIA
DIAMETER
KW
KILOWATTS
SQ
SQUARE
DISC
DISCONNECT
SQFT
SQUARE FEET
DISCH
DISCHARGE
L
LENGTH
SRV
SAFETY RELIEF VALVE
DS
DOWNSPOUT
LAC
LAB AIR COMPRESSOR
ST
STEAM TRAP
CEASE
DOMESTIC SOFT WATER BOOSTER PUMP
LAD
LAB AIR DRYER
STO
STANDARD
DUD
DOOR UNDER CUT
LAN
LOCAL AREA NETWORK
STM
STORM
GAS
DRAWING
LAT
LEAVING AIR TEMPERATURE
STIR
STARTER
DW
DISTILLED WATER
LAV
LAVATORY
STRUCT
STRUCTURAL
OWES
DOMESTIC WATER BOOSTER PUMP
LBO
LINEAR BAR DIFFUSER
Sit
STEAM VENT
OWH
DOMESTIC WATER HEATER
IRS
POUNDS
SW
SWITCH
LO
LINEAR DIFFUSER
SYS
SYSTEM
EA
EXHAUST AIR
LF
LINEAR FOOT
SZ
SPRINKLER ZONE
EAT
ENTERING AIRTEMPERATURE
LED
LAMINAR FLOWDIFFUSER
EBH
ELECTRIC BASEBOARD HEATER
LET
LEAVING FLUID TEMPERATURE
T
THERMOSTAT
EC
ELECTRICAL CONTRACTOR
DOC
LOCATION
TB
TERMINAL BOX
ECC
ENVIRONMENTAL CONTROL CONTRACTOR
LPR
LOW PRESSURE CONDENSATE RETURN
TCC
TEMPERATURE CONTROL CONTRACTOR
ECG
EGG CRATE GRILLE
LEE
LOW PRESSURE STEAM
TDH
TOTAL DISCHARGE HEAD
ED
EXHAUST DIFFUSER
LVG
LEAVING
TOV
TRIPLE DUTY VALVE
EDC
ELECTRIC DUCT COIL
LIVE
LAB VACUUM PUMP
TEMP
TEMPERATURE
EER
ENERGY EFFICIENCY RATIO
LWT
LEAVING WATER TEMPERATURE
THIN
TEMPERED HOT WATER
EF
EXHAUST AIR FAN
TILL
TEMPERATURE LOW LIMIT
EFT
ENTERING FLUID TEMPERATURE
MA
MEDICALAIR
TMV
THERMOSTAT MIXING VALVE
EG
EXHAUST GRILLE OR ETHYLENE GLYCOL
MAC
MEDICAL AIR COMPRESSOR
TMBH
TOTAL MBH
ELEC
ELECTRIC
MAD
MED ICAL AIR DRYER
TSP
TOTAL STATIC PRESSURE
ELEV
ELEVATION
MAI
MED ICAL AIR INTAKE
TW
TEMPERED WATER
EMER
EMERGENCY
MAT
MIXED AIR TEMPERATURE
TYP
TYPICAL
EMG
EXTRUDED METAL GRILLE
MAX
MAXIMUM
ENCL
ENCLOSURE
MB
MOP BASIN
UH
UNIT HEATER
ENTR
ENTERING
MBH
BTUIHRX 1000
ONO
UNLESS NOTED OTHERWISE
EOM
END OF MAIN DRIP
MC
MECHANICAL CONTRACTOR
OR
URINAL
EQA
EQUIPMENT AIR
MCA
MINIMUM CIRCUIT AMPACITY
UVL
ULTRA VIOLET LIGHT
EQAC
EQUIPMENT AIR COMPRESSOR
MCC
MOTOR CONTROL CENTER
EQAI
EQUIPMENT AIR INTAKE
MD
MOTORIZED DAMPER
V
VENT
EQUIP
EQUIPMENT
MECH
MECHANICAL
VAC
VACUUM
EQV
EQUIPMENT VACUUM
MFR
MANUFACTURER
VAV
VARIABLE AIR VOLUME
EQUIP
EQUIPMENT VACUUM PUMP
MH
MANHOLE
VB
VACUUM BREAKER
EQVV
EQUIPMENT VACUUM VENT
MIN
MINIMUM
VD
VOLUME DAMPER (MANUAL)
ERP
ELECTRIC RADIANT PANEL
MISC
MISCELLANEOUS
VEL
VELOCITY
ES
EMERGENCY SHOWER
MOCP
MAXIMUM OVERCURRENT PROTECTION
VSC
VARIABLE SPEED CONTROLLER
ESP
EXTERNAL STATIC PRESSURE OR ELEVATOR SUMP PUMP
MPSR
MEDIUM PRESSURE CONDENSATE RETURN
VTR
VENT THROUGH ROOF
ET
EXPANSION TANK
MPS
MEDIUM PRESSURE STEAM
VV
VACUUM VENT
EUH
ELECTRIC UNIT HEATER
MTD
MOUNTED
EW
EMERGENCY EYEWASH
MV
MED ICAL VACUUM
W
WASTE, WATTS OR WIDTH
EWC
ELECTRI C WATER COOLS R
MVP
MED ICAL VACUUM PUM P
WAGO
WASTE ANESTHESIA G AS D I S POSAL PUMP
EWT
ENTERING WATER TEMPERATURE
WB
WET BULB
EXH
EXHAUST
N
NORTH OR NITROGEN
WI
WITH
EXIST
EXISTING
NA
NOT APPLICABLE
WIO
WITHOUT
EXT
EXTERIOR
NC
NORMALLY CLOSED OR NOISE CRITERIA
WC
WATER CLOSET OR WATER COLUMN
NIC
NOT IN CONTRACT
AGO
WALL CLEAN OUT
F
DEGREES FAHRENHEIT
NM
NITROGEN MANIFOLD
WFMD
WATER FLOW MEASURING DEVICE
FBB
FACE B BYPASS
NO
NORMALLY OPEN, NITROUS OXIDE, OR NUMBER
WG
WATER GAUGE
FBT
FLOAT AND THERMOSTATIC TRAP
NOM
NOMINAL OR NITROUS OXIDE MANIFOLD
AST
WEIGHT
CIA
FIRE ALARM
NTS
NOT TO SCALE
WH
WALL HYDRANT
FISO
FIRE AND SMOKE DAMPER
AM
WATER METER
FC
FLEXIBLE CONNECTION
0
OXYGEN
WP
WEATHERPROOF
FCU
FAN COIL UNIT
CA
OUTSIDE AIR
WPO
WATER PRESSURE DROP
ED
FLOOR DRAIN OR FIRE DAMPER
OAT
OUTSIDE AIRTEMPERATURE
AS
WATER SOFTENER
FH
FIRE HOSE OR FUME HOOD
k
POUND
VALVE AND FITTING SYMBOLS
TAGS
PLAN VIEWS
DETAIL
V1
EW
CALIBRATED BALANCE VALVE
V2
PIPING FLEXIBLE CONNECTION
V3
--0
PIPE TURNED UP (UNLESS NOTED OTHERWISE)
VI
D
PIPE TURNED DOWN
V5
PIPE OUT TOP
V6
=
PIPE OUT BOTTOM
VT
THREADED NIPPLE WICAP
VS
P I PE WITH BLIND FLANGE
V9
CON CENTRI C REDUCER
V10
-JkhF-
ECCENTRIC REDUCER
V11
�ri
CHECK VALVE
V12
UNION
V13
F..a 6 M
GATE VALVE
VI
BALL VALVE
V15
pq
GLOBE VALVE
V16
JIM I
BUTTERFLY VALVE
V17
TEMPERATURE CONTROL- 2 WAY MODULATING VALVE
V16
TEMPERATURE CONTROL- 2 WAY 2 POSITION MODULATING VALVE
V19
C
OC
TEMPERATURE CONTROL- 3 WAY MODULATING VALVE
V20
O
TEMPERATURE CONTROL- 3 WAY 2 POSITION MODULATING VALVE
V21
SAFETY RELIEF VALVE
V22
STRAINER
V23
#
FLOWMETER
V24
® 8
®
FLOOR DRAIN
V25
ZONE CONTROL VALVE(OSBY)
V26
AUTOMATIC FLOW CONTROL VALVE
V27
FLOW MEASURING DEVICE
V26
MANUAL AIR RELIEF VENT
V29
If
AUTOMATIC AIR RELIEF VENT
VIM
LUBRICATED PLUG VALVE
V31
STEAM PRESSURE REDUCING VALVE
V32
ANGUS VALVE
V33
GAS PRESSURE RELIEF VALVE
V34}
REFRIGERANT HOT GAS BY-PASS VALVE
V35
SHUT-OFF COCK(HYDRONICS)
V36
SOLENOID VALVE
V37
REFRIGERANT EXPANSION VALVE
V36
WATER PRESSURE REDUCINGIREGULATING VALVE
V39
COMBINATION WATER PRESSURE RELIEF AND REDUCING VALVE
V40
0
—FTY
STEAMTRAP
V41
DIELECTRIC UNION BETWEEN STEEL AND COPPER
V42
to
_Eeco�
STRAINER (STEAM)
V43
PRESSURE AND TEMPERATURE PLUG
V44
#
REFRIGERANT SIGHT GLASS
V45
THERMOMETER
V46
(ADDRESS V=VAC T=TEMP)GAUGE
V47
IT]
SENSOR (T-TEMP H-HUMIDITY)
V48
8
FLOW SWITCH
V49
CLEAN OUT
V50
a
WATER HAMMER ARRESTOR OR ALARM PRESSUREVACUUM SWITCH
V51
Zr
INDICATED EXPANSION LOOP (COLD SPRUNG)
V52—
ANCHOR
V53
GUIDE
V54
T
�nI V �y r
REDUCED PRESSURE BACKFLOW PREVENTER
V55
�
ATMOSPHERIC VACUUM BREAKER
V56
p
8-
PRESSUREVACUUM BREAKER
V57
REFRIGERANT SHUT-OFF VALVE
V56
DOMESTIC WATER TEMPERATURE REGULATING VALVE
V59
EXPANSION JOINT
VW
ZIrv'�
DIFFERENTIAL SWITCH
V61
A
CENTRAL VACUUM OUTLET
PLUMBING PIPING SYMBOLS
6'DCW, —
DOMESTIC COLD WATER
GPDHW �j - -
1 DOMESTIC HOT WATER
6" DRAM
- - - DOMESTIC HOT WATER RETURN
6'FPE
FIRE PROTECTION
SIP NG�
NATURAL GAS
EDST
V
LU
I
O
W
am
-----'rv1-----
VENT
60
�� - - DOMESTIC SOFT COLD WATER
■
GENERAL NOTES
(REQUIRED TO COMPLETE THE SCOPE OF WORK)
1. ALL CONTRACT DOCUMENTS (SPECIFICATIONS AND DRAWINGS) ARE COMPLIMENTARY AND
MUST BE USED IN COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION.
2. ALL CONFLICTS SHALL BE BROUGHT TO THE ARCHITECTS OR ENG INEERS ATTENTION IN
ORDER TO ALLOW A CLARIFICATION TO BE ISSUED. ANY WORK COMPLETED WITHOUT THE
CLARIFYING INFORMATION IS AT THE CONTRACTORS FINANCIAL RISK.
3, THE CONTRACTOR SHALL P ROVIDE AND FU RN ISH ALL MATER IALS AND ACCESSORIES TO
CREATE A FULLY OPERATIONAL, CODE COMPLIANT AND TESTED SYSTEM. ALL MATERIALS
AND ACCESSORIES REQUIRED TO CREATE THE FULLY OPERATIONAL SYSTEM SHALL BE
INCLUDED IN THE COST OF THIS PROJECT.
4. THESE DRAWINGS ARE D IAG RAMMAT IC IN NATU RE. THE CONT RACTOR MAY AT THE R OPTI ON
MOD IFY THE PIPE ROUTING IN ORDER TO CREATE A SYSTEM THAT MEETS THE INTENT OF THIS
SET OF CONSTRUCTION DOCUMENTS.
5. THE CONTRACTOR SHALL INCLUDE ALL ITEMS THAT ARE REQUIRED TO ENSURE THAT THE
ENTIRE SYSTEM IS FUNCTIONING IN COMPLIANCE WITH THE APPLICABLE CODES, AND
MANUFACTURES INSTALLATION RECOMMENDATIONS AND OR REQUIREMENTS.
6, ALL CUTTING, DRILLING AND PATCHING OF WALLS, FLOORS ANDIOR STRUCTURAL MEMBERS
FOR THE INSTALLATION OF THE PLUMBING AND FIRE PROTECTION SYSTEMS SHALLBE
PROVIDED AS PART OF THE SCOPE OF THIS PROJECT.
7. STRUCTURAL COMPONENTS SHALL NOT BE CUT, DRILLED OR MODIFIED IN ANY WAY WITHOUT
THE STRUCTURAL ENGINEERS REVIEW AND PRIOR WRITTEN APPROVAL
S. PROVIDE FIRE STOPPING WHERE PIPES PENETRATE FIRE RATED FLOORS AND WALLS. FIRE
STOPPING MATERIALS AND METHODS SHALL BE PER LOCAL AND STATE CODES AND
REQUIREMENTS.
9. ALL PLUMBING SYSTEMS SHALLBE INSTALLED PER THE CURRENT PLUMBING CODE FOR THE
LOCATION OF THE WORK BEING INSTALLED.
10. ALL PLUMBING EQUIPMENT ,PIPING ,FIXTURES , AND PIPE ACCESSORIES SHALL BE NSF 61,
ANNEX G COMPLIANT.
11. ALL PIPING LOCATED WITHIN A RETURN AIR PLENUM SHALL COMPLY WITH A 25150 FLAME
SMOKE RATING. ANY EXISTING PIPING DISCOVERED WITHIN A RETURN AIR PLENUM THAT
DOES NOT COMPLY WITH THIS REQUIREMENT SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT FOR FURTHER CLARIFICATION.
12. ALLEXTERIOR WALL PENETRATIONS SHALL BE SEALED WATER AND WEATHERTIGHT BY THE
APPROPRIATE TRADE COMPETENT IN COMPLETING THIS WORK. THE COST OF THIS WORK
SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT.
13. ALLVENTTHROUGH ROOF (VTR) LOCATIONS SHALLBE FIELD VERIFIED IN REGARDS TO ANY
OUTDOOR INTAKE. LOCATION OF VTR SHALL BE NO LESS THAN AS REQUIRED BY THE LOCAL
OR STATE CODES.
14. DO NOT ATTACH ANY CONSTRUCTION TO THE ROOF DECK JOIST BRIDGING, JOIST CROSS
BRACING, PIPING, CONDUIT, DUCTWORK OR ANY OTHER NON-STRUCTURAL ITEM.
15. DO NOT WELD OR DRILL INTO STRUCTURAL STEEL OR JOIST', INSTEAD USE CLAMPS, TIE WIRE,
THRU-BOLTS WITH WASHERS
16. DO NOT USE ANY PVC,PLASTIC,ETC. IN PLENUM OR DEMISING WALLS UNLESS FIRE WRAPPED.
ALL WOOD BLOCKING AND NAILER$, CONCEALED OR NOT SHALL BE FIRE RETARDANT
TREATED.
17. DO NOT PENETRATE BUILDING WALLS FOR ANY DUCTING OR VENTING', ROUTE THROUGH ROOF
USING LANDLORDS ROOFING CONTRACTOR.
ie. VENT THROUGH ROOF INSTALLATION ALL ROOFING WORK SHALL BE COMPLETED BY THE
LANDLORDS ROOFING CONTRACTOR. THE COST SHALL BE INCLUDED IN THE SCOPE OF THIS
PROJECT.
19. PIPING BELOW GROUND SHALL BE SERVICE -WEIGHT CAST IRON OR SCHEDULE 40 PVC NO -HUB
PIPING OR FERNCO CONNECTIONS ARE NOT PERMITTED BELOW GRADE.
20 DOMEST IC WATER PI P ING ABOVE G RACE SHALL BE TYPE "L"WATER TUBE.
21. ALL PIPING SHALL BE PROPERLY SUSPENDED BY THE STRUCTURE PER THE LOCAL CODES.
22, NO SANITARY WASTE OR VENT, HOT OR COLD WATER SHALLBE ALLOWED TO BE INSTALLED IN
THE DEMISING WALLS.
23. ALL PIPING INSULATED SHALLBE WITH PLENUM RATED MATERIALS.
24. FLOOR DRAINS SHALL BE PROVIDED WITH TRAP PRIMERS.
25, GAS PIPING SUPPORTED ON THE ROOF SHALL BE PROVIDED FREE FLOATING PREFABRICATED
SUPPORTS OR EQUIPMENT SUPPORTS WITH ROLLER ASSEMBLIES. WOOD SUPPORTS WILL
NOT BE PERMITTED.
26. ALL GAS PIPING SHALL BE PROVIDED PIPE LABELS IDENTIFYING THE GAS PRESSURE.
27. ALL G AS P IP ING SHALL BE IN STALLED PER THE LOCAL CODES F OR MATERIALS AND
INSTALLATIONS REQUIREMENTS.
28. ALL SHUT -DOWN OF UTILITIES AND FIRE PROTECTION SYSTEMS SHALL BE ARRANGED WITH NO
LESS THAN SEVEN (7) DAYS NOTICE TO THE LANDLORD. WORK MAY NOT COMMENCE UNLESS
WRITTEN APPROVAL IS PROVIDED BY THE LANDLORD.
29. ALL DOMESTIC WATER BRANCH PIPES SERVING FIXTURES OR EQU IPMENT WITH FAST ACTING
OR ELECTRONIC VALVES SHALL BE PROVIDED WATER HAMMER ARRESTORS.
30, ALL BRANCH PIPES FROM DOMESTIC WATER MAINS SHALL BE PROVIDED QUARTER TURN FULL
PORT BALL VALVES ON THE BRANCH PIPE JUST ADJACENT TO THE MAIN.
FLOOR PLAN SYMBOLS
t TYP SECTION WITH NATI NUMBER INDICATING
SECTION DESIGNATION AND BOTTOM
A101 NUMBER
INDICATING DRAWING THAT SECTION IS CUT
ON
TYP
DETAIL WITH
IO TOP LETTER INDICATING DETAIL
p101 DESIGNATION
AND BOTTOM NUMBER INDICATING DRAWING THAT DETAIL
IS REFERENCED ON OR DRAWING THAT DETAIL IS DRAWN
ON
iO PLAN NOTE
TON THERMOSTAT - "N"INDICATING NIGHT SETBACK THERMOSTAT
O HUMIDISTAT
TO TE
A. GENERAL NOTEHAT SECTION IS DRAWN ON
1 PLAN NOTE UST
CONNECTION OF NEW WORK TO EXISTING
Z
O
10
LU
U
Q
U)
J
MO
5W
I
N
J
J
a
II1IIIII1
1 I
CERTIFICATION
gy'�.�pM 1A. y,('�Y
}#� cs�nrq osi
'A P[NOh9IX1�J1 ¢ s
MAT UP
ALL INFORMATION CONTAINED IN THIS DOC IRAN 19
CONSIDERED MOE HURT CONFIDEMALAND
PROPRIETARY INALLDRIAL PROPERTY UP ATACAMA
STUDINAND SHALLM07 RE COPIED REPRODUCED
DISTRIBUTED OR ASSIGNED TO A MAT RD PARTY WITHOUT
AMUCHORIZED USE Of THESE DOC AMENTS 19 NOR
PERMITTED
ANNINNIN
ARCHITECT
BLACKLINE
AUTONOMOUS INDIANA Pi
M.E.P.
GENESIS ENGINEERING GROUP
91 SOUTH MAIN THREAT MAW TRA
STRUCTURAL
SCHWARZ ENGINEERING GROUP
H CAN Al 33
Z
_O
a_
LLNU
�13./f
IM
W
a
0
Z
♦a
vJ
J UU
O L)
cm W a Z
C y
>NA DO O E
W a
U
Ur Z o
Z m m
_ O C C_
M Y N 6
Od Od
On O O
J O O O
ANNINNIN
DRAWN. CHECKED'.
WAM WAM
Motion and Main Brownstone
Interior Remodel — Units 90,
60,70,50
111112019
® P70.0