HomeMy WebLinkAboutP70.1 Plumbing Basement 1st FlrJ RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City 9f Carmel (� �VT�'lmA�(LOAA� DATE: 02/12/19 N ATU RAL GAS MAIN A, I �1 BASEMENT SANITARY -LOT 70 114" = 1'-0" 2^ GIPE WRNIN iNEL eE wSO TeoWmnoN TG PROTECT HE FREEZING IN,xe wAA DOOR IS DAMAGED t 2" S 22AA 2 3" S 3" Q 26 1112 V 2" V 0 2"V 1112^V I 1 yr2.NES1 4314" PLAN NOTES 1 DO NOT ROUTE ANY WIRING,PIPING, DUCTWORK, ETC THROUGH LIFTSHAFT. 2 PROVIDE TO 3^ STEEL PIPE BULLARDS TO PROTECT UTILITY GAS METER FROM ACCIDENTAL DAMAGE. 3 UTILITY GAS MAIN. COORDIANTE BOLLARD LOCATION WITH MAIN 4 WATER COMPANY METER PIT WITH TRAFIC RATED LID 5 REFER TO SITE PLANS FOR CONTIN UATION OF 4^S MAIN, 6 REFER TO SITE PLANS FOR CONTI NUATI ON OF III STORM MAIN 7 INSTALLATION OF WATERMAIN SHALL BE PER UTILITY REQUIREMENTS PROTECT FROM DAMAGE DURING CONSTRUCTION, B INSTALLATION OF SANITARY MAIN SHALL BE PER STATE AND LOCAL CODE. PROTECT FROM DAMAGE DURING CONSTRUCTION, 9 INSTALLATION OF DEWATERING MAIN SHALL BE PER STATEAND LOCAL CODES. PROTECT FROM DAMAGE DURING CONSTRUCTION 10 S SLEEVE THROUGH FOUNDATION WALL AND CAP FOR FUTURE. 11 314' WATER MAIN FIELD COORDINATE LOCATION INTO STRUCTURE, 12 DEWATERING PIT, DESIGNED FOR RADON MITIGATION SYSTEM 13 PASSIVE RADON VENT, DESIGNED ROUTED AND INSTALLED BY OTHERS. 14 ALL VENT PIPE SHALL BE ROUTED THROUGH THE FLOOR SYSTEM. 15 SIFF MAIN, PROTECT FROM DAMAGE DURING CONSTRUCTION. 16 FPMAIN, PROVIDE UNIT ISOLATION VALVE, FLOW AND TAMPER SWITCH AND ALL OTHER REUQIRED ACCESSORIES TO CREATE A COMPLETE, CODE COMPLIANT AND OPERATIONAL INSTALLATION. 17 2^STORMDRAIN. CONNECT TO SITE STORM DRAINAGE SYSTEM 18 2^ STORM DRAIN LETO POLISHED BRASS AREA DRAIN 19 PROVIDE NATURAL GAS PRESSURE REDUCING 2 PSIG TO I0'WC, VALVE AND ISOLATION VALVE TO SERVE NATURAL GAS HEADER. CONTRACTOR SHALL FIELD COORDIANTE AND FIELD ROUTE ALL NATURAL GAS PIPES FROM THIS MANIFOLD TO ALL GAS FIRED APPLIANCES. MINIMUM PIPE DIAMETER SHALL BE 3I4'TO ANY APPLIANCE. PROVIDE ISOALTION VALVE AND ALL OTHER REUQIRED ACCESSORIES IN ORDER TO MAKE FINAL CONNECTDIONS TO ALL NATURAL GAS FLED APPLIANCES, FIREPLACES, GRILLES. 20 DOMESTIC WATER HEATER -rV, 2'INTAKE, TERMINATE PER MANUFACTURE REQUIREMENTS, TEMINATEVENT PER CODE MINIMUM DISTANCES 21 CONTRACTOR SHALL COORDIANTE THE INSTALLATION OF ALL EQUIPMENT WITH CUSTOM LIVING NO EQUIPMENT SHALL BE INSTALLED WITHOUT FULL COORDIANTION. 22 PRIOR TO INSTALLATION OF ANY PLUMBING PIPING SYSTEMS, THE CONTRACTOR SHALL COORDINATE THE PIPE ROUTING WITH ALL OTHER TRADES, INCLUDING CUSTOM LIVING. NO BULKHEADS WILL BE PROVIDED TO CONCEAL PIPING SYSTEMS WITHIN THE STRUCTIRE. 23 ALL DOMESTIC WATER SHALL BE INSULATED TO PROTECT FROM FREEZING. THE CONTRACTOR SHALL INSULATE PIPE WITH ELASTOMERIC INSULATION AND ALSO PROVIDE FIBERGLASS BAT INSULATION UNDER ALL WASTE AND VENT PIPING TO FURTHER ENSURE THAT PIPE DO NOT FREEZE IN THE EVENT THAT THE GARAGE DOORS BECOME DAMAGED. 24 RADON VENT PATHWAY, RADON VENT PROVIDED AND INSTALLED BY OTHERS, 25 CONTRACTOR SHALL PROVIDE WASHER BOX WITH 2' DRAIN, WATER HAMMER ARRESTORS AND ISOLATION VALVES WITH SINGLE HANDLE OPERATION. COORDIANTE THE EXACT LOCATION WITH THE EQUIPMENT TO BE S INSTALLED, PROVIDE DRAIN PAN UNDERCLOTHES WASHER AND PIPE COMPLETE TO THE SANITARY DRAINAGE SYSTEM. PROVIDE FOOD GRADE MINERAL OIL TO SEAL THE PIPE TRAP. 26 PROVIDE FREEZE PROOF EXTERIOR HOSE VALVE, COORDIANTE EXACT LOCATION WITH CUSTOM LIVING PRIOR TOINSTALLATIOtl, 27 PROVIDE 112'NATRUAL GAS CONNECTION WITH ISOLATION VALVE AND PLUG (FOR FUTURE CONNECTION) OCORDIANTE THE EXACT LOCATION WITH CUSTOM LIVING. 2B FIELD ROUTE III FROM NATURALA GAS HEADER TO FIRE PLACE AND CONNECT III TO NATURAL GAS FIRE PLACE, INSTALL PER CODE AND MANUFACTURES RECOMMENDATIOtlS, CONTRACTOR SHALL COORDINATE THE 'V LOCATION OF THE NATURAL GAS SHUT-OFF VALVE WITH CUSTOM LIVING. 29 ROUTE 11I FROM NATURAL GAS HEADER TO STOVEIOVEN. INSTALL PER CODE AND EQUIPMENT MANUFACTUREREQURIEMENTS. COORDIANTE WITH CUSTOM LIVING THE EXACT REQUIREMENTS FOR THE APPLIANCE, 30 ROUTE 1RANG FROM HEADERTO CLOTHES DRYER. CONNECT PER CODE AND MANUFACTURES REQUIREMENTS. OCORDIANTE WITH CUSTOM LIVING THE EXACT MODEL OF EQUIPMENT TO BE INSTALLED. 31 ROUTE 30'NG FROM HEADER AND CONNECT PER CODE AND MANUFACTURES REQUIREMENTS. 32 DOMES TIC WATER PIPE ROUTED THROUGH PIPE SLEEVE ACROSS SANITARY MAIN 33 ROUTE CONDENSATE DRAIN AND FURNACE CONDENSATE TO FLOOR DRIAN I OPEN STE DRAIN. PROVIDEDRAIN PAN UNDER ALL MECHANICAL EQUIPMENT AND ROUTE DRAIN TO FLOOR DRAIN. COORDIANE THE INSTALLATION OF THE FURNACE WITH THE DRAIN. NO EQUIPMENT OR PIPE SHALL BE INSTALLED WITHOUT COORDIANTION WITH CUSTOM LIVING. 34 ROUTE DOMESTIC HOTAND COLD WATER FROM RISERS AT THIS LOCATION TO SERVE ALL PLUMBING FIXTURES. NO WATER PIPE SHALL BE ROUTED IN ANY UN -HEATED SPACE WITHOUT COORDIANTION WTIH CUSTOM LIVING, 35 PROVIDE CHECK VALVE ON DHW RETURN MAIN TO ENSURE NO BACK FLOW HO WATER TOPLUMBINGFIXTURES. CONNECT FIXTURES ON THIRD AND FOURTH LEVELS TO WATER PIPES ON THIS FLOOR 36 INSTALL REFRIGERATOR BOX WITH MINI-ARRSTOR, CONNECT PER MANUFACTURES REQUIREMENTS. COORDINATE THE EXACT LOCATION WITH CUSTOM LIVING, 37 PROVIDE FIXTURE AND INSTALL COMPLETE, PROVIDE FOOD WASTE GRINDER, CONNECT DISHWASHER COMPLETE, COORDIANTE ALL FIXTURES WITH CUSTOM LIVING PRIOR TO THE INSTALLATION OF ANY PIPE, 3B COORDIANTE ALL FIXTURES AND TRIM WTH CUSTOM LIVING, COORDIANTE ALL ROUGH -IN LOCATIONS AND ELEVATIONS WITH CUSTOM LIVING PRIOR TO INSTALLATION OF ANY PIPING. 39 4^ST UP, FOR EXTERIOR DOWNSPOUT 40 COORDINATE THE LOCATION OF THE FREE STANDING TUB 2'VW AND THE SHOWER FLOOR DRAIN LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION OF ANY PIPE. 41 ALL SINKS WITH ADJACENT ICE MACHINES SHALL BE PROVIDED A TAIL PIECE ON THE SECOND BASIN TO ALLOW FOR THE ICE MACHINE PUMP TO PUMP DISCHARGE WATER INTO THE SINK DRAINAGE SYSTEM. COORDIANTE WITH CUSTOM LIVING ALL RECUIREMENTS. 0 — I t 0 t �1 FIRST FLOOR SANITARY PLAN -LOT 70 QUARE DOWNSPOUT I'C'MaeWETRAXSGIOX FIIIIXG SQUARE DOWNSPOUT TO MOUND STORM 9R\HST AGUETLC %1 EMERGENCY DEWATERING OUTLET DETAIL 114" BB 1'-0" IIIIIIIII CERTIFICATION: ALL INFORMATION CONTAINED IN THISCOCUMENT 15 CONSIDERED US BE ROT" CORI AGO PROPRIETARY INTELLECTUAL PROPERTY OF MACHINE STUDIO AND SMALL NOT BE COINED BEHOLDERS DISTRIBUTED OR ASSIGNED TO A LURE PARTY WITHOUT UTHORIZE) USE OF THESE DOCUMENTS 15 ART PERMITTED IIIIIIIIIIA ARCHITECT BLACKLINE I IMERNIUMIN AT MI ADD wiiiiiiiiiw M.E.P. GENESIS ENGINEERING GROUP MIAMI IN Am?? wiiiiiiiiiw STRUCTURAL SCHWARZ ENGINEERING GROUP AT PART N 33 Z J am w O O J LL cN w IIIIIIIIN LL 0 Z Q Z W w W Z ni z N w C3 cUl v W C a w OHE. U W Z G DO c U ) c m O m m � a � ' ad Dd CD N O O JEASE c c 0 J DRAWN. CHECKED. Author Checker REVLSiON Me Motion and Main Brownstone Interior Remodel — Units 90, 60,70,50 111112019 IIIIIIIIIIA (+ P70-1