HomeMy WebLinkAboutP70.1 Plumbing Basement 1st FlrJ
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City 9f Carmel (�
�VT�'lmA�(LOAA�
DATE: 02/12/19
N ATU RAL GAS MAIN A,
I
�1 BASEMENT SANITARY -LOT 70
114" = 1'-0"
2^
GIPE WRNIN iNEL
eE wSO TeoWmnoN
TG PROTECT
HE FREEZING IN,xe
wAA DOOR IS DAMAGED
t
2" S
22AA
2
3" S 3"
Q
26
1112 V
2" V
0
2"V 1112^V
I
1 yr2.NES1
4314"
PLAN NOTES
1 DO NOT ROUTE ANY WIRING,PIPING, DUCTWORK, ETC THROUGH LIFTSHAFT.
2 PROVIDE TO 3^ STEEL PIPE BULLARDS TO PROTECT UTILITY GAS METER FROM ACCIDENTAL DAMAGE.
3 UTILITY GAS MAIN. COORDIANTE BOLLARD LOCATION WITH MAIN
4 WATER COMPANY METER PIT WITH TRAFIC RATED LID
5 REFER TO SITE PLANS FOR CONTIN UATION OF 4^S MAIN,
6 REFER TO SITE PLANS FOR CONTI NUATI ON OF III STORM MAIN
7 INSTALLATION OF WATERMAIN SHALL BE PER UTILITY REQUIREMENTS PROTECT FROM DAMAGE DURING
CONSTRUCTION,
B INSTALLATION OF SANITARY MAIN SHALL BE PER STATE AND LOCAL CODE. PROTECT FROM DAMAGE DURING
CONSTRUCTION,
9 INSTALLATION OF DEWATERING MAIN SHALL BE PER STATEAND LOCAL CODES. PROTECT FROM DAMAGE
DURING CONSTRUCTION
10 S SLEEVE THROUGH FOUNDATION WALL AND CAP FOR FUTURE.
11 314' WATER MAIN FIELD COORDINATE LOCATION INTO STRUCTURE,
12 DEWATERING PIT, DESIGNED FOR RADON MITIGATION SYSTEM
13 PASSIVE RADON VENT, DESIGNED ROUTED AND INSTALLED BY OTHERS.
14 ALL VENT PIPE SHALL BE ROUTED THROUGH THE FLOOR SYSTEM.
15 SIFF MAIN, PROTECT FROM DAMAGE DURING CONSTRUCTION.
16 FPMAIN, PROVIDE UNIT ISOLATION VALVE, FLOW AND TAMPER SWITCH AND ALL OTHER REUQIRED ACCESSORIES
TO CREATE A COMPLETE, CODE COMPLIANT AND OPERATIONAL INSTALLATION.
17 2^STORMDRAIN. CONNECT TO SITE STORM DRAINAGE SYSTEM
18 2^ STORM DRAIN LETO POLISHED BRASS AREA DRAIN
19 PROVIDE NATURAL GAS PRESSURE REDUCING 2 PSIG TO I0'WC, VALVE AND ISOLATION VALVE TO SERVE
NATURAL GAS HEADER. CONTRACTOR SHALL FIELD COORDIANTE AND FIELD ROUTE ALL NATURAL GAS PIPES
FROM THIS MANIFOLD TO ALL GAS FIRED APPLIANCES. MINIMUM PIPE DIAMETER SHALL BE 3I4'TO ANY
APPLIANCE. PROVIDE ISOALTION VALVE AND ALL OTHER REUQIRED ACCESSORIES IN ORDER TO MAKE FINAL
CONNECTDIONS TO ALL NATURAL GAS FLED APPLIANCES, FIREPLACES, GRILLES.
20 DOMESTIC WATER HEATER -rV, 2'INTAKE, TERMINATE PER MANUFACTURE REQUIREMENTS, TEMINATEVENT
PER CODE MINIMUM DISTANCES
21 CONTRACTOR SHALL COORDIANTE THE INSTALLATION OF ALL EQUIPMENT WITH CUSTOM LIVING NO EQUIPMENT
SHALL BE INSTALLED WITHOUT FULL COORDIANTION.
22 PRIOR TO INSTALLATION OF ANY PLUMBING PIPING SYSTEMS, THE CONTRACTOR SHALL COORDINATE THE PIPE
ROUTING WITH ALL OTHER TRADES, INCLUDING CUSTOM LIVING. NO BULKHEADS WILL BE PROVIDED TO
CONCEAL PIPING SYSTEMS WITHIN THE STRUCTIRE.
23 ALL DOMESTIC WATER SHALL BE INSULATED TO PROTECT FROM FREEZING. THE CONTRACTOR SHALL INSULATE
PIPE WITH ELASTOMERIC INSULATION AND ALSO PROVIDE FIBERGLASS BAT INSULATION UNDER ALL WASTE AND
VENT PIPING TO FURTHER ENSURE THAT PIPE DO NOT FREEZE IN THE EVENT THAT THE GARAGE DOORS
BECOME DAMAGED.
24 RADON VENT PATHWAY, RADON VENT PROVIDED AND INSTALLED BY OTHERS,
25 CONTRACTOR SHALL PROVIDE WASHER BOX WITH 2' DRAIN, WATER HAMMER ARRESTORS AND ISOLATION
VALVES WITH SINGLE HANDLE OPERATION. COORDIANTE THE EXACT LOCATION WITH THE EQUIPMENT TO BE
S INSTALLED, PROVIDE DRAIN PAN UNDERCLOTHES WASHER AND PIPE COMPLETE TO THE SANITARY DRAINAGE
SYSTEM. PROVIDE FOOD GRADE MINERAL OIL TO SEAL THE PIPE TRAP.
26 PROVIDE FREEZE PROOF EXTERIOR HOSE VALVE, COORDIANTE EXACT LOCATION WITH CUSTOM LIVING PRIOR
TOINSTALLATIOtl,
27 PROVIDE 112'NATRUAL GAS CONNECTION WITH ISOLATION VALVE AND PLUG (FOR FUTURE CONNECTION)
OCORDIANTE THE EXACT LOCATION WITH CUSTOM LIVING.
2B FIELD ROUTE III FROM NATURALA GAS HEADER TO FIRE PLACE AND CONNECT III TO NATURAL GAS FIRE
PLACE, INSTALL PER CODE AND MANUFACTURES RECOMMENDATIOtlS, CONTRACTOR SHALL COORDINATE THE
'V LOCATION OF THE NATURAL GAS SHUT-OFF VALVE WITH CUSTOM LIVING.
29 ROUTE 11I FROM NATURAL GAS HEADER TO STOVEIOVEN. INSTALL PER CODE AND EQUIPMENT
MANUFACTUREREQURIEMENTS. COORDIANTE WITH CUSTOM LIVING THE EXACT REQUIREMENTS FOR THE
APPLIANCE,
30 ROUTE 1RANG FROM HEADERTO CLOTHES DRYER. CONNECT PER CODE AND MANUFACTURES REQUIREMENTS.
OCORDIANTE WITH CUSTOM LIVING THE EXACT MODEL OF EQUIPMENT TO BE INSTALLED.
31 ROUTE 30'NG FROM HEADER AND CONNECT PER CODE AND MANUFACTURES REQUIREMENTS.
32 DOMES TIC WATER PIPE ROUTED THROUGH PIPE SLEEVE ACROSS SANITARY MAIN
33 ROUTE CONDENSATE DRAIN AND FURNACE CONDENSATE TO FLOOR DRIAN I OPEN STE DRAIN. PROVIDEDRAIN
PAN UNDER ALL MECHANICAL EQUIPMENT AND ROUTE DRAIN TO FLOOR DRAIN. COORDIANE THE INSTALLATION
OF THE FURNACE WITH THE DRAIN. NO EQUIPMENT OR PIPE SHALL BE INSTALLED WITHOUT COORDIANTION
WITH CUSTOM LIVING.
34 ROUTE DOMESTIC HOTAND COLD WATER FROM RISERS AT THIS LOCATION TO SERVE ALL PLUMBING FIXTURES.
NO WATER PIPE SHALL BE ROUTED IN ANY UN -HEATED SPACE WITHOUT COORDIANTION WTIH CUSTOM LIVING,
35 PROVIDE CHECK VALVE ON DHW RETURN MAIN TO ENSURE NO BACK FLOW HO WATER TOPLUMBINGFIXTURES.
CONNECT FIXTURES ON THIRD AND FOURTH LEVELS TO WATER PIPES ON THIS FLOOR
36 INSTALL REFRIGERATOR BOX WITH MINI-ARRSTOR, CONNECT PER MANUFACTURES REQUIREMENTS.
COORDINATE THE EXACT LOCATION WITH CUSTOM LIVING,
37 PROVIDE FIXTURE AND INSTALL COMPLETE, PROVIDE FOOD WASTE GRINDER, CONNECT DISHWASHER
COMPLETE, COORDIANTE ALL FIXTURES WITH CUSTOM LIVING PRIOR TO THE INSTALLATION OF ANY PIPE,
3B COORDIANTE ALL FIXTURES AND TRIM WTH CUSTOM LIVING, COORDIANTE ALL ROUGH -IN LOCATIONS AND
ELEVATIONS WITH CUSTOM LIVING PRIOR TO INSTALLATION OF ANY PIPING.
39 4^ST UP, FOR EXTERIOR DOWNSPOUT
40 COORDINATE THE LOCATION OF THE FREE STANDING TUB 2'VW AND THE SHOWER FLOOR DRAIN LOCATION WITH
CUSTOM LIVING PRIOR TO INSTALLATION OF ANY PIPE.
41 ALL SINKS WITH ADJACENT ICE MACHINES SHALL BE PROVIDED A TAIL PIECE ON THE SECOND BASIN TO ALLOW
FOR THE ICE MACHINE PUMP TO PUMP DISCHARGE WATER INTO THE SINK DRAINAGE SYSTEM. COORDIANTE
WITH CUSTOM LIVING ALL RECUIREMENTS.
0 —
I
t 0
t
�1 FIRST FLOOR SANITARY PLAN -LOT 70
QUARE DOWNSPOUT
I'C'MaeWETRAXSGIOX
FIIIIXG
SQUARE DOWNSPOUT
TO MOUND STORM 9R\HST
AGUETLC
%1 EMERGENCY DEWATERING OUTLET DETAIL
114" BB 1'-0"
IIIIIIIII
CERTIFICATION:
ALL INFORMATION CONTAINED IN THISCOCUMENT 15
CONSIDERED US BE ROT" CORI AGO
PROPRIETARY INTELLECTUAL PROPERTY OF MACHINE
STUDIO AND SMALL NOT BE COINED BEHOLDERS
DISTRIBUTED OR ASSIGNED TO A LURE PARTY WITHOUT
UTHORIZE) USE OF THESE DOCUMENTS 15 ART
PERMITTED
IIIIIIIIIIA
ARCHITECT
BLACKLINE
I IMERNIUMIN AT MI ADD
wiiiiiiiiiw
M.E.P.
GENESIS ENGINEERING GROUP
MIAMI IN Am??
wiiiiiiiiiw
STRUCTURAL
SCHWARZ ENGINEERING GROUP
AT PART N 33
Z
J
am
w
O
O
J
LL
cN
w
IIIIIIIIN
LL
0
Z
Q
Z
W
w
W
Z
ni
z
N
w
C3
cUl
v
W
C
a
w
OHE.
U
W
Z
G
DO
c
U
)
c
m
O
m
m
�
a
�
'
ad
Dd
CD
N
O
O
JEASE
c
c
0
J
DRAWN.
CHECKED.
Author
Checker
REVLSiON
Me
Motion and Main Brownstone
Interior Remodel — Units 90,
60,70,50
111112019
IIIIIIIIIIA
(+ P70-1