HomeMy WebLinkAboutA023 - SECTION DETAILS8" 8" 8" 9'-0"3'-0"UNDISTURBED SOIL 16"W X 8"D CONTINUOUS CONCRETE FOOTER TO MIN. 32" BELOW GRADE 8" CONCRETE STEM WALL COMPACTED FILL PAVER STONES TREATED 2X4 WALL FRAMING 1/2" CEMENT BOARD THIN STONE VENEER STONE WALL CAP 1X CEDAR HEADER TRIM 3-PLY 11 7/8" LVL BLOCKING AS NECESSARY SMOOTH VENTED FIBER CEMENT SOFFIT ALUMINUM GUTTER & DRIP EDGE 2X4 SUBFASCIA 2X8 RAFTERS 7/16" OSB DECKING DIMENSIONAL SHINGLES 1X4 CEDAR TRIM 1X6 PINE TONGUE & GROOVE 2X10 CEILING JOISTS COLUMN BEYOND 1'-1 1 /4" 1 0 5/8" 1'-4" 9'-0"3'-4"UNDISTURBED SOIL WIDE CONTINUOUS CONCRETE FOOTER TO MIN. 32" BELOW GRADE WIDE CONCRETE STEM WALL COMPACTED FILL PAVER STONES TREATED 2X4 WALL FRAMING 1/2" CEMENT BOARD THIN STONE VENEER STONE WALL CAP 3-PLY 11 7/8" LVL BLOCKING AS NECESSARY SMOOTH VENTED FIBER CEMENT SOFFIT ALUMINUM GUTTER & DRIP EDGE 2X4 SUBFASCIA 2X8 RAFTERS 7/16" OSB DECKING DIMENSIONAL SHINGLES 1X4 CEDAR TRIM 1X6 PINE TONGUE & GROOVE 2X10 CEILING JOISTS 1X CEDAR HEADER TRIM TREATED 6X6 POST CEDAR 1X2 & 1X4 COLUMN BASE & CROWN TRIM SIMPSON STRONG-TIE (OR EQUIV.) COLUMN BASE BRACKET ANCHORED TO FOUNDATION 1'-4"9'-0"3'-4"TREATED 2X4 WALL FRAMING STONE WALL CAP 3-PLY 11 7/8" LVL BLOCKING AS NECESSARY SMOOTH VENTED FIBER CEMENT SOFFIT ALUMINUM GUTTER & DRIP EDGE 2X4 SUBFASCIA 2X8 RAFTERS 7/16" OSB DECKING DIMENSIONAL SHINGLES 1X4 CEDAR TRIM 1X6 PINE TONGUE & GROOVE 2X10 CEILING JOISTS 1X CEDAR HEADER TRIM TREATED 6X6 POST PAVER STONES COMPACTED FILL CEDAR 1X2 & 1X4 COLUMN BASE & CROWN TRIM 18"ø CONCRETE PIER FOOTER TO MIN. 32" BELOW GRADE UNDISTURBED SOIL 1/2" CEMENT BOARD THIN STONE VENEER SIMPSON STRONG-TIE (OR EQUIV.) COLUMN BASE BRACKET ANCHORED TO PIER #1 of 27 Date: 1.24.19 Sheet: Revision: www.caseindy.com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f) These drawings have been prepared by Case Design & Remodeling solely for its use and should not be reproduced or relied upon by any other parties. Dimensions shown or scaled are subject to change per actual job condition and must be verified. Materials are to be supplied as specified as equal or standard when not uniquely specified. Installed materials may vary in appearance from drawings. Reference manufacturer's product data for actual appearance and specifications.Federici ResidencePavilion & Outdoor LivingJohn & Devana Federici12966 Pontell Pl.Carmel, Indiana 46074Approved By: Date: 23 FINAL Jordan Stocklin Designer jstocklin@caseindy.com Dave Null Lead Designer dnull@caseindy.com SECTION DETAILS SCALE: 1/2" = 1' WALL SECTION AA POST SECTION BB POST SECTIONCC #2 1.29.19 #3 1.31.19 #4 2.11.19 02/13/19 Mike Sheeks