10 FIRST FLOOR LIFE SAFETY PLAN
A009 1/8" = 114"
CODE INFORMATION
Applicable Codes:
2012 International Building Code
2014 Indiana Building Code (IBC)
2014 Indiana Mechnical Code (IMC)
ICC/ANSI A-117.1 Standard, 2009 Edition
Scope of Project:
Renovtion of existing community
clubhouse.
Occupancy Classifications:
Business
B Occupancy [304.1]
Construction Type:
Type VA combustile - non sprinklered
construction.
[Table 601]
Allowable Area:
Existing Structure
Allowable Height:
Existing Structure
Building Elements -
Building elements, including structural frame,
Fire -Resistive
exterior walls, floors and roof are permitted to be
Requirements:
of combustible construction with 1-hour fire
rating.
[Table 601]
Floor Openings,
N/A Single Story
Penetrations and
Shafts:
Incidental Use
None applicable to this project. [fable 509]
Separations:
Means of Egress:
2 means of egress are required from rooms with
a calculated occupant load of 50 or more, or
where exceeding 100 feet in B, M and S-1
Occupancy Spaces. [1014.3, 1015.1]
Illumination required and emergency power for
illumination required for extis. [1006.1,1006.3]
Occupant Load Factors:
Business 100sf per occupant
Exercise 50sf per occupant
Corridors:
Corridors are permitted to be of 1-hour fire resistance
rating construction throughout based occupancy type
and load
[1018.1]
Exit Access Travel
The maximum travel distance to an exterior exit is
Distance:
permitted to be a maximum of 200 feet for B
Occupancy.
[1016.11
Panic Hardware:
Panic hardware not required in areaswith an
occupancy less than 50. [1008.1.9.4 Exception
Item 3]
Automatic Sprinklers:
Building is not equiped with automatic sprinklers
Fire Alarm Systems:
Fire alarm system not required. [907.2.21
Smoke Detectors:
Smoke detectors are required for HVAC shutdown
for systems delivering in excess of 2, 000cfm.
[606. 1, IMC]
FIRE LEGEND
MAJOR EXITING ROUTE
1 HR. RATED CONSTRUCTION
IF( OWLAND I DESIGN
ARCHITECTURE INTERIORS GRAPHICS
702 North Capitol Avenue
Indianapolis, Indiana 46204
p 317 6363980
f 317 263-2073
www.rowlanddesign.com
BUCKI NGHAM
COMPANIES
f Na. "1..
ARI9S000Ba
° STAT0' g
A'YDIq;r
ggCH
VILLAGE ON
SPRINGMILL
14637 HANDEL DR.
CARMEL IN 46032
1/10/19
PERMIT SET
NO. DESCRIPTION DATE
PERMIT SET 1/7/2019
PROJECTNUMBER
18.085
SHEET ISSUE DATE
1/1049
DRAWN BY
RB
CHECKED BY
NH
LIFE SAFETY PLAN