HomeMy WebLinkAboutA401 First floor Reflected CeilingNEW GYP. BULKHEAD T-I A ABOVE CABINETS. REFER T( PLAN FOR MORE INFORMAT NEW GYP. CEILING. CEILING P6, REFER TO FINISH PLAN. CONTRACTOR TO PROVIDE ALARMS WHERE REQUIF INTO EXIST LIGHT FIXTURE SCHEDULE TYPE MNFR MOUNTING ITEM # SIZE FINISH DEGREE K. DIMMING DESCRIPTION C1 SHADES OF CEILING FAN FA16032 13.5H X 60" DIA. BRONZE 3000K NO CONTRACTOR TO VERIFY MOUNTING HEIGHT WITH BLADE CLEARANCES IN VAULTED CEILING. LIGHT BZ M1 SHADES OF FLUSH MOUNT FMIS041S &H X 13" DIA. BRONZE & GLASS 3000K NO MODERN RIBBED CEILING LIGHT -SMALL. MAX- (2) 60 WATT LAMPS LIGHT P1 CIRCA LIGHTING PENDANT TOB-5303B 26.75"H X 45" DIA BRONZEIBRASS & 3000K NO MARAIS LARGE CHANDELIER. MAX - (12) 60 WATT E12 LAMPS. OVERALL HEIGHT TO BE 8'-0" Z/HAB-WG WHITE GLASS FROM CEILING TO BOTTOM OF FIXTURE. CIRCA TO PROVIDE EXTRA ROD EXTENSIONS AND CHAIN AS REQUIRED. P2 LBL LIGHTING PENDANT LP1071 BZL 16"H X 16" DIA. PERAL BUBBLE 2700K NO MALENA LARGE. MOUNTING HEIGHT 66" A.F.F. ED927 P3 LBL LIGHTING PENDANT LP7720PG 14.2"H X 5.4" DIA. OPAL & GRAY 2700K NO MEZZO PENDANT. MAX (1) 100 WATT LAMP. MOUNTING HEIGHT 66" A.F.F. COORDINATE DEPTH YLED827 OF FIXTURE LOCATION WITH SINK LOCATION. R1 HALO RECESSED DOWNLIGHT LT460WH6 4 INCH LED WHITE 3000K NO INSTALL INTO EXISTING CAN HOUSING. CONTRACTOR TO VERIFY SIZE OF EXISTING CANS RETROFIT 930 RETROFIT AND COMPATABILITY WITH SPECIFIED RETROFIT. CONTACT TRACI ASHCRAFT OF SPECIFIED LIGHTING FOR MORE INFORMATION 317.863.7024 R2 HALO RECESSED DOWNLIGHT LT460WH6 4 INCH LED WHITE 3000K NO INSTALL WITH HALO H245RICAT REMODELER HOUSING. CONTACT TRACI ASHCRAFT OF 930 SPECIFIED LIGHTING FOR MORE INFORMATION 317.863.7024 R3 ALO RECESSED DOWNLIGHT- RA406930 4" ADJUSTABLE WHITE 3000K NO INSTALL WITH HALO H245RICAT REMODELER HOUSING. CONTACT TRACI ASHCRAFT OF WALL WASH WH DOWN SPECIFIED LIGHTING FOR MORE INFORMATION 317.863.7024 W1 ENATION [REJ WALL SCONCE A6505 5"W X 9.75"H - ORB &ORB 3000K NO CYPRESS ARTICULATING SCONCE. MAX (1) 40 WATT LAMP. OIL RUBBED BRONZE FIXTURE 1 1 AND SHADE Subject to compliance with all regulatims of State and Local Codes City of Camuell �VT�t�G*T41WML DATE: 02/18/19 THEN ENLARGED RCP 0 0 0 U 1 FIRST FLOOR REFLECTED CEILING PLAN Aao1 1/8" = 1'-0" GENERAL REFLECTED CEILING NOTES A. THESE GENERAL NOTES APPLY TO SERIES 400 CEILING SHEETS. B. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL CHECK ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, FIRE PROTECTION, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. PLAN LOCATIONS SHOWN FOR LIGHTING, DIFFUSERS, SPRINKLER HEADS, ETC. ARE TO ILLUSTRATE DESIGN INTENT. GENERAL CONTRACTOR SHALL COORDINATE FINAL LOCATIONS. ANY CHANGES OR DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECT'S/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR TO THE COMMENCEMENT OF NEW WORK. C. ALL GWB CEILING BULKHEADS AND SOFFITS TO BE LEVEL 5 FINISH. PROVIDE CONTROL JT. WHERE NEW CEILING. WORK ABUTS EXIST'G PLASTER. D. PROVIDE CONSTRUCTION JOINTS IN GWB CEILING CONSTRUCTION AT "CJ" AND WHERE INDICATED. CENTER CONSTRUCTION JOINTS ON BUILDING LINES EXCEPT AS INDICATED. WHERE NOT INDICATED, PROVIDE CONTROL JOINTS @ 16'-0" MAX. SPACING. REVIEW FINAL LOCATIONS WITH ARCHITECT BEFORE BEGINNING WORK. E. CENTER AND ORIENT LIGHT FIXTURES IN ROOM AS IMPLIED BY CEILING PLANS EXCEPT AS INDICATED BY DIMENSION OR PLAN NOTE. LIGHTING FIXTURES ARE DIMENSIONED FROM CENTER LINE OF THE FIXTURE. F. CENTER CEILING PENETRATIONS (RECESSED FIXTURES, SPRINKLER HEADS, ELECTRICAL DEVICES, ETC.) IN CEILING PANELS EXCEPTAS INDICATED. G. LOCATE AIR INLETS AND OUTLETS AND CEILING ELECTRICAL IN CEILING AS IMPLIED BY CEILING PLANS. H. PAINT EXPOSED GWB AND PLASTER CEILING, BULKHEAD, AND SOFFIT SURFACES AS INDICATED IN FINISH SCHEDULE. I. CONTRACTOR SHALL PROVIDE AND INSTALL EXIT SIGNS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. CONTRACTOR SHALL COORDINATE THE PLACEMENT OF EXIT LIGHTS WITH ENGINEER, FIRE OFFICIAL, AND ARCHITECT/DESIGNER. ALL EXIT LIGHTS ARE TO BE BUILDING STANDARD. J. PAINT ALL CEILING SURFACES AS INDICATED ON PLAN WHERE EXPOSED TO VIEW. K. PROVIDE MOISTURE -RESISTANT GWB FOR CEILINGS IN ROOMS CONTAINING SHOWERS. L. REFER TO ELECTRICAL DRAWINGS FOR CEILING -MOUNTED LIGHT FIXTURE TYPES AND QUANTITIES. M. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER HEAD TYPES AND QUANTITIES LOCATE SPRINKLER HEADS AS INDICATED ON CEILING OR FIRE PROTECTION PLANS. REFLECTED CEILING PLAN LEGEND NOTE: REFER TO MECHANICAL, ELECTRICAL AND PLUMBING PLANS FOR FIXTURE TYPE AND ACTUAL DIMENSIONS +X'-X" CEILING HEIGHT NEW GYPSUM BOARD CEILING mm ACOUSTICAL PANEL CEILING (GRID) -0w, WALL SCONCE ® 2X4 SURFACE MOUNT FIXTURE Hx i RECESSED DOWNLIGHT FIXTURE # REFLECTED CEILING PLAN KEYNOTES IF( OWLAND I DESIGN ARCHITECTURE INTERIORS GRAPHICS 702 North Capitol Avenue Indianapolis, Indiana 46204 p 317 6363980 f 317 263-2073 www.rowlanddesign.com BUCKI NGHAM COMPANIES INC. n a AR194ODD63 I d STATE OF j' VILLAGE ON SPRINGMILL 14637 HANDEL DR. CARMEL IN 46032 1 NO WORK IN THIS AREA. 1 /1 0/1 9 2 WALLS OF DORMERS TO BE PAINTED P2. TYP. PERMIT SET 3 CEILING TO BE PAINTED P6. REFER TO FINISH PLAN. 4 FIXTURE TO BE MOUNTED 8'-4" A.F.F. TO CENTER OF MOUNTING PLATE NO. DESCRIPTION DATE 1 Revision 1 12.17.18 5 NEW GYP. CEILING. CEILING TO BE PAINTED P6. REFER TO 50% PRICING SET 8/24/2018 FINISH PLAN. PRICING SET 9/5/2018 PERMIT SET 1f7/2019 6 NEW GYP. BULKHEAD 7'-0" A.F.F. ABOVE CABINETS. REFER TO FINISH PLAN AND ELEVATIONS FOR FINISH INFORMATION. 7 FIXTURE TO BE MOUNTED 10-6" A.F.F. TO CENTER OF MOUNTING PLATE PROJECT NUMBER 18.085 8 NEW BULKHEAD TO EXTEND FROM NEW CASEWORK TO SHEET ISSUE DATE 1110119 EXISTING CEILING. DRAWN BY JIs CHECKED BY RB 9 CONTRACTOR TO PATCH AND REPAIR CEILING WHERE WALL WAS REMOVED. FINISH FACE TO BE FLUSH WITH FIRST FLOOR FACES OF THE ADJOINING. REFLECTED CEILING 10 PROVIDE NEW EXTERIOR CARRIAGE LIGHITNG AT THIS PLAN LOCATION. PROVIDE ALLOWANCE FOR $400, CONFIRM FINAL SPECIFICATION WITH DESIGNER. i ,If"