HomeMy WebLinkAboutA401 First floor Reflected CeilingNEW GYP. BULKHEAD T-I A
ABOVE CABINETS. REFER T(
PLAN FOR MORE INFORMAT
NEW GYP. CEILING. CEILING
P6, REFER TO FINISH PLAN.
CONTRACTOR TO PROVIDE
ALARMS WHERE REQUIF
INTO EXIST
LIGHT FIXTURE SCHEDULE
TYPE
MNFR
MOUNTING
ITEM #
SIZE
FINISH
DEGREE K.
DIMMING
DESCRIPTION
C1
SHADES OF
CEILING FAN
FA16032
13.5H X 60" DIA.
BRONZE
3000K
NO
CONTRACTOR TO VERIFY MOUNTING HEIGHT WITH BLADE CLEARANCES IN VAULTED CEILING.
LIGHT
BZ
M1
SHADES OF
FLUSH MOUNT
FMIS041S
&H X 13" DIA.
BRONZE & GLASS
3000K
NO
MODERN RIBBED CEILING LIGHT -SMALL. MAX- (2) 60 WATT LAMPS
LIGHT
P1
CIRCA LIGHTING
PENDANT
TOB-5303B
26.75"H X 45" DIA
BRONZEIBRASS &
3000K
NO
MARAIS LARGE CHANDELIER. MAX - (12) 60 WATT E12 LAMPS. OVERALL HEIGHT TO BE 8'-0"
Z/HAB-WG
WHITE GLASS
FROM CEILING TO BOTTOM OF FIXTURE. CIRCA TO PROVIDE EXTRA ROD EXTENSIONS AND
CHAIN AS REQUIRED.
P2
LBL LIGHTING
PENDANT
LP1071 BZL
16"H X 16" DIA.
PERAL BUBBLE
2700K
NO
MALENA LARGE. MOUNTING HEIGHT 66" A.F.F.
ED927
P3
LBL LIGHTING
PENDANT
LP7720PG
14.2"H X 5.4" DIA.
OPAL & GRAY
2700K
NO
MEZZO PENDANT. MAX (1) 100 WATT LAMP. MOUNTING HEIGHT 66" A.F.F. COORDINATE DEPTH
YLED827
OF FIXTURE LOCATION WITH SINK LOCATION.
R1
HALO
RECESSED DOWNLIGHT
LT460WH6
4 INCH LED
WHITE
3000K
NO
INSTALL INTO EXISTING CAN HOUSING. CONTRACTOR TO VERIFY SIZE OF EXISTING CANS
RETROFIT
930
RETROFIT
AND COMPATABILITY WITH SPECIFIED RETROFIT. CONTACT TRACI ASHCRAFT OF SPECIFIED
LIGHTING FOR MORE INFORMATION 317.863.7024
R2
HALO
RECESSED DOWNLIGHT
LT460WH6
4 INCH LED
WHITE
3000K
NO
INSTALL WITH HALO H245RICAT REMODELER HOUSING. CONTACT TRACI ASHCRAFT OF
930
SPECIFIED LIGHTING FOR MORE INFORMATION 317.863.7024
R3
ALO
RECESSED DOWNLIGHT-
RA406930
4" ADJUSTABLE
WHITE
3000K
NO
INSTALL WITH HALO H245RICAT REMODELER HOUSING. CONTACT TRACI ASHCRAFT OF
WALL WASH
WH
DOWN
SPECIFIED LIGHTING FOR MORE INFORMATION 317.863.7024
W1
ENATION
[REJ
WALL SCONCE
A6505
5"W X 9.75"H -
ORB &ORB
3000K
NO
CYPRESS ARTICULATING SCONCE. MAX (1) 40 WATT LAMP. OIL RUBBED BRONZE FIXTURE
1
1
AND SHADE
Subject to compliance with all regulatims
of State and Local Codes
City
of Camuell
�VT�t�G*T41WML
DATE: 02/18/19
THEN ENLARGED RCP
0 0 0 U
1 FIRST FLOOR REFLECTED CEILING PLAN
Aao1 1/8" = 1'-0"
GENERAL REFLECTED CEILING NOTES
A. THESE GENERAL NOTES APPLY TO SERIES 400 CEILING SHEETS.
B. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL CHECK ALL CEILING
HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, FIRE
PROTECTION, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT
INDICATED. PLAN LOCATIONS SHOWN FOR LIGHTING, DIFFUSERS, SPRINKLER HEADS, ETC. ARE
TO ILLUSTRATE DESIGN INTENT. GENERAL CONTRACTOR SHALL COORDINATE FINAL
LOCATIONS. ANY CHANGES OR DISCREPANCY SHALL BE BROUGHT TO THE
ARCHITECT'S/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR TO THE COMMENCEMENT OF NEW
WORK.
C. ALL GWB CEILING BULKHEADS AND SOFFITS TO BE LEVEL 5 FINISH. PROVIDE CONTROL JT.
WHERE NEW CEILING. WORK ABUTS EXIST'G PLASTER.
D. PROVIDE CONSTRUCTION JOINTS IN GWB CEILING CONSTRUCTION AT "CJ" AND WHERE
INDICATED. CENTER CONSTRUCTION JOINTS ON BUILDING LINES EXCEPT AS INDICATED.
WHERE NOT INDICATED, PROVIDE CONTROL JOINTS @ 16'-0" MAX. SPACING. REVIEW FINAL
LOCATIONS WITH ARCHITECT BEFORE BEGINNING WORK.
E. CENTER AND ORIENT LIGHT FIXTURES IN ROOM AS IMPLIED BY CEILING PLANS EXCEPT AS
INDICATED BY DIMENSION OR PLAN NOTE. LIGHTING FIXTURES ARE DIMENSIONED FROM
CENTER LINE OF THE FIXTURE.
F. CENTER CEILING PENETRATIONS (RECESSED FIXTURES, SPRINKLER HEADS, ELECTRICAL
DEVICES, ETC.) IN CEILING PANELS EXCEPTAS INDICATED.
G. LOCATE AIR INLETS AND OUTLETS AND CEILING ELECTRICAL IN CEILING AS IMPLIED BY CEILING
PLANS.
H. PAINT EXPOSED GWB AND PLASTER CEILING, BULKHEAD, AND SOFFIT SURFACES AS INDICATED
IN FINISH SCHEDULE.
I. CONTRACTOR SHALL PROVIDE AND INSTALL EXIT SIGNS IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE. CONTRACTOR SHALL COORDINATE THE PLACEMENT OF EXIT
LIGHTS WITH ENGINEER, FIRE OFFICIAL, AND ARCHITECT/DESIGNER. ALL EXIT LIGHTS ARE TO
BE BUILDING STANDARD.
J. PAINT ALL CEILING SURFACES AS INDICATED ON PLAN WHERE EXPOSED TO VIEW.
K. PROVIDE MOISTURE -RESISTANT GWB FOR CEILINGS IN ROOMS CONTAINING SHOWERS.
L. REFER TO ELECTRICAL DRAWINGS FOR CEILING -MOUNTED LIGHT FIXTURE TYPES AND
QUANTITIES.
M. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER HEAD TYPES AND QUANTITIES
LOCATE SPRINKLER HEADS AS INDICATED ON CEILING OR FIRE PROTECTION PLANS.
REFLECTED CEILING PLAN LEGEND
NOTE: REFER TO MECHANICAL, ELECTRICAL AND PLUMBING PLANS FOR FIXTURE TYPE AND ACTUAL
DIMENSIONS
+X'-X" CEILING HEIGHT
NEW GYPSUM BOARD CEILING
mm
ACOUSTICAL PANEL CEILING (GRID)
-0w, WALL SCONCE
® 2X4 SURFACE MOUNT FIXTURE
Hx
i RECESSED DOWNLIGHT FIXTURE
# REFLECTED CEILING PLAN KEYNOTES
IF( OWLAND I DESIGN
ARCHITECTURE INTERIORS GRAPHICS
702 North Capitol Avenue
Indianapolis, Indiana 46204
p 317 6363980
f 317 263-2073
www.rowlanddesign.com
BUCKI NGHAM
COMPANIES
INC. n
a AR194ODD63 I d
STATE OF j'
VILLAGE ON
SPRINGMILL
14637 HANDEL DR.
CARMEL IN 46032
1 NO WORK IN THIS AREA. 1 /1 0/1 9
2 WALLS OF DORMERS TO BE PAINTED P2. TYP. PERMIT SET
3 CEILING TO BE PAINTED P6. REFER TO FINISH PLAN.
4 FIXTURE TO BE MOUNTED 8'-4" A.F.F. TO CENTER OF
MOUNTING PLATE NO. DESCRIPTION DATE
1 Revision 1 12.17.18
5 NEW GYP. CEILING. CEILING TO BE PAINTED P6. REFER TO 50% PRICING SET 8/24/2018
FINISH PLAN. PRICING SET 9/5/2018
PERMIT SET 1f7/2019
6 NEW GYP. BULKHEAD 7'-0" A.F.F. ABOVE CABINETS. REFER
TO FINISH PLAN AND ELEVATIONS FOR FINISH
INFORMATION.
7 FIXTURE TO BE MOUNTED 10-6" A.F.F. TO CENTER OF
MOUNTING PLATE
PROJECT NUMBER 18.085
8 NEW BULKHEAD TO EXTEND FROM NEW CASEWORK TO SHEET ISSUE DATE 1110119
EXISTING CEILING. DRAWN BY JIs
CHECKED BY RB
9 CONTRACTOR TO PATCH AND REPAIR CEILING WHERE
WALL WAS REMOVED. FINISH FACE TO BE FLUSH WITH FIRST FLOOR
FACES OF THE ADJOINING. REFLECTED CEILING
10 PROVIDE NEW EXTERIOR CARRIAGE LIGHITNG AT THIS PLAN
LOCATION. PROVIDE ALLOWANCE FOR $400, CONFIRM
FINAL SPECIFICATION WITH DESIGNER. i