19020018 Building Plans
MECHANICAL & ELECTRICAL NOTES I. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO BASIC DESIGN -BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE DESIGN -BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL, ELECTRICAL AND PLUMBING DESIGN -BUILD CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES, FIRE SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN -BUILD CONTRACTOR AND MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM DESIGN -BUILD CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS. 2. MECHANICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES, 3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE OF NEW EQUIPMENT, REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING OWNER/LANDLORD. 4. RELOCATE AIR- SUPPLY DIFFUSERS AND RETURN- AIR GRILLES AS REQUIRED, PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES, LOCATION OF DIFFUSERS SHOWN ON PLAN IS FOR REFERENCE ONLY. CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY CODE. 5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR OTHER CONFLICTS. PROVIDE BALANCE REPORTS TO OWNER UPON COMPLETION OF PROJECT. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. COMPLY WITH THE I NDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED. 9. ALL ELECTRICAL OUTLETS WITHI N 6'-O'OF WATER ARE TO BE G.F.C.I. 10. AT EACH PHONE AN D DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AN D PROVIDING APPROPRIATE TERMINALS AT FACE PLATE. 11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCH PLATES TO MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE. 12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN. REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FI NAL CONNECTION FROM WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS. 13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RU NNING ELECTRICAL CONDUITS TO JUNCTION BOXES. 14. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. 15. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A. REQUIREMENTS AN D ARE CONSISTENT THROUGHOUT. 16. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE) GANG BOX WITH SINGLE COVER PLATE. 17. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED. 18. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMAANDIBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 19, PROVIDE ALARM NOTIFICATION APPLIANCES HORNS STROBES EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM &DETECTION SYSTEMS AS NECESSARY i0 MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION, FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE, 20, COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DEFECTION DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT -INSTALLED ITEMS (I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS), 21. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING SPACES. CONSULT WITH LANDLORD. ALL LAMPS ARE TO BE MATCHING IN CRI AND MANUFACTURER. 22. NEW AND EXISTING PLUMBING LINES IN CEILING ARE TO TO BE INSULATED. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 02/18/19 GENERAL PROJECT NOTES I. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE. 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK. 3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. 4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE. 5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC. 6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON -SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION, THE CONTRACTOR SHALL ALSO COORDINATE WORK 'BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. 7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. B. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AN D COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. 9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION. 10. SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING ASAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES. 11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT. 12. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DEMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. 13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK, DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24" O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH SIDE, 14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS, (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN). 15. SCHOTT DESIGN,INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE. 16. PROVIDE FIRETREATEDWOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC. FINISH NOTES I. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. 2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. )SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS, CORNER BEADS, ETC.) 3. REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM DESIRED COLOR PRIOR TO PURCHASING NEW. 4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. 5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN Q.E. WHERE VCT MEETS CARPET), 6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. 7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED. 8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 9. SUBMIT FI NISH SAMPLE OF MILLWORK(STAINED OR PAINTED AS SPECIFIED) TO SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 10. REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION, 11, ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT, 12. ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. 17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. 18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 19, ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT, THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. 20. ALL DETAILS,MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER, 21, REVIEW AND COORDINATE ALL NEW WORK AN D EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE -BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. 22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AN D ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED. 23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. 25, ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCE S WORK & DO NOT LEAK. 27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 29, CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD. 30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT, 31. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE -RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. 32. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FITTIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 33. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON LIDO IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION. 34. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES, ADJUST DOORS AND FRAMES AS REQUIRED. FIRE PROTECTION NOTES I, FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE W ITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING, MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT, DEMOLITION NOTES I. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS. 2. NO STRUCTURAL OR LOAD -BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS DURING DEMOLITION CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S)IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD -BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING THOSE ITEMS THAT MAYBE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OF WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS. 4. WHERE EQUIPMENT,FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHEDLINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION. 6. REMOVE ALL CARPET, VINYL BASE,VCT, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN. 7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED. SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION. 8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID INSTRUCTIONS. 9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES, THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT. 10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION) REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PUTS CABLES. REFER TO SECTION 300.21. 11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL OR VOICE DATA SYSTEMS ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFETY REGULATIONS OR PROCEDURES. TAKE BACK TO SOURCE IF NOT BEING REUSED. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN"AS-BUILT'SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS, DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY. MILL/CASEWORK NOTES I. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GENERAL CONTRACT. 2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION. 4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS -BUILT CONDITIONS IN FIELD, REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE I NTENT OF THE DESIGN SHOWN ON THE DRAWINGS. 5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. 6. REFER TO MILLWORK SECTIONS & ELEVATIONS , UNLESS OTHERWISE SHOWN, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4' BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED. 7. EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED OTHERWISE. IF PVC EDGING IS BEING PROPOSED BY FABRICATOR FOR EDGES OF CABINETS AND DRAWERS, FABRICATOR MUST PROVIDE SAMPLE OF COLOR MATCHING SPECIFIED PLASTIC LAMINATE FOR APPROVAL. B. REFER TO MILLWORK SECTIONS&ELEVATIONS FOR CABINETRY SPECIFICATIONS (CUSTOM PLASTIC LAMINATE OR PRE -MANUFACTURED STOCK CABINETRY). 9. TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND CABIN ETRV WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED. 5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK, 6, FIRE STOP ANY EXISTING DECK PENETRATIONS. DOCUMENT APPROVAL TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS. TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT, THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. ; e El tE. au ND i]No.1F Noryna:© QMeeM1egY 11611 Norlh ,MVIrtnn END Cal B Truck Slits Care Ceei .�awN l Wooala.a Coamry Club Qrxeess%i N, 0 i �``v E,„an O 1 � If NAND E u<LEsl $ '""°"" sl"lyyll IIKQ MI men - ® If 1 115 111,, d ga Lni S VICINITY MAP NOT TO SCALE KEY PLAN - 2ND FLOOR NOT TO SCALE INDEX OF DRAWINGS TIII COVER SHEET AND GENERAL PROJECT NOTES LIDO LIFE SAFETY PLAN Al I I DEMOLITION PLAN /ARCHITECTURAL FLOOR PLAN AI2I ELECTRICAL PLAN / REFLECTED CEILING PLAN: HVAC / LIGHTING A2I I FINISH PLAN / DOOR SCHEDULE / INTERIOR DETAILS N THIS DRAWING, AND THE IDEAS, RESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, IN C_ AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT 0FSCHOTT DESIGN. W (V V 0 Q No O Z Zoz a �- Q J - LU INS N Z V' Q Z--U � Q Z O�7 za WV)Q0 L U Z � w AA LU w �ET� LU z Z - r SSUE DATE DESCRIPTION 11.27.18 REVIEW SET 12.06.18 PERMITSET EVISONS AARK DATE DB DESCRIPTION No. 70 AR10700017 c^ A ST TE OF TIERED PR�� PROJECT NUMBER 2018.415 PROD. MGR DRAWN BY AS CB 2ND FLOOR COVER SHEET AND GENERAL NOTES T111 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CODE SUMMARY SCOPE OF WORK PREVIOUS USE OF SPACE OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE BUSINESS) OCCUPANCY CLASSIFICATION B(USINESS) CHANGE OF OCCUPANCY CUSS? NO TOTAL BUILDING AREA 22,155 SF/FLOOR X 1 8 STORIES = 177,240 SF TOTAL PROJECT AREA 2,020 SF OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD GEN. OFFICE 2020 SF 100 21 TOTAL OCCUPANTS IN PROJECTAREA 21 NUMBER OF EXITS REQUIRED: I PROVIDED: I SPRINKLER SYSTEM(YES/NO) YES- EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 22,155 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A ASHRAE 90.1 SUMMARY EXEMPT (SEE REFLECTED CEILING PLAN) NO BUILT BEFORE 19782 BUILDING CONSTRUCTION TYPE III LEGEND EP EXISTING ELECTRICAL PANEL LOCATION EJ( EXISTING EXIT. BUILDING STAIR LOCATION FE FF FIRE EXTINGUISHER EXITSIGN &® ® EMERGENCY LIGHT — — — TRAVEL DISTANCE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City Bf Camel DATE: 02/18/19 71 AREA NOT IN CONTRACT ❑ AREA OF WORK LIFE SAFETY NOTES I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. ELECTRICIAN TO RELOCATE EXISTING. ANY NEW FIXTURES TO BE ADDED BY OWNER'S LIFE SAFETY VENDOR ONLY. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. FIRE EXTINGUISHERS PROVIDED BY TENANT. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING GENERAL NOTES H. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. LIFE SAFETY PLAN 0 4' 8' 16, N THIS DRAWING, AND THE IDEAS, IESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT 0FSCHOTT DESIGN. W C\J U `Y) a QO Q C*4 N �_-ww ry ZZNU - LL Ex I- Z�Q W Vi Z 0 0 ~ p LU Z _ Cw CL LU LU LU -7 0 Q Z ISSUE DATE DESCRIPTION 11.27.18 REVIEW SET 12.06.18 PERMITSET EVISONS ARK DATE DB DESCRIPTION H 80I �_ No. 70 AR10700017 , STATE OF �. PROJECT NUMBER 2018.415 PROD. MGR DRAWN BY AS CB 2ND FLOOR LIFE SAFETY L100 DEMOLITION LEGEND EXISTING TO BE REMOVED EXISTING TO REMAIN WALL ozoxox PARTIAL HEIGHT WALL DOOR AND FRAME WINDOW/SIDELIGHT --- — IT CEILING GRID AND ------Ir TILES. 2'x4' —� CEILING GRID AND TILES,2'x2' Fri ¢_y SUPPLY AIR DIFFUSERS LIGHT FIXTURE, FLUORESCENT, 2'x4' r - 1 LIGHT FIXTURE, o l FLUORESCENT, 2'x2' 1 11 jj LIGHT FIXTURE, CAN `+ LIGHT FIXTURE, TRACK ttO LIGHT FIXTURE, SCONCE LIGHT FIXTURE, 4"A PENDANT LIGHT SWITCH F EXIT LIGHT L��L6T ELECTRIC CHI 1ell" DATA OR COMMUNICATION OUTLET WALL PARTIAL HEIGHT WALL 7 DOOR AND FRAME x WINDOW/SIDELIGHT NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. AREA NOT IN CONTRACT RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 02/18/19 DEMOLITION PLAN NOTES 001 REMOVE PORTION OF WALL FOR NEW SUITE ENTRY DOOR. SEE DOOR SCHEDULE FOR DIMENSIONS AND MORE INFORMATION. DEMOLITION PLAN 0 2' 4' 8' 16, GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. CONFIRM THAT ALL EXISTING WALLS ARE FULLY INSULATED. IF NOT, PROVIDE NEW INSULATION AS REQUIRED. ARCHITECTURAL LEGEND NEW CONSTRUCTION wwwwiiim WALL ® PARTIAL HEIGHT WALL wa WINDOW/SIDELIGHT DOOR AND FRAME (SEE DOOR SCHEDULE) iiiiiiimm EXISTING TO REMAIN WALL ® PARTIAL HEIGHT WALL > WINDOW/SIDELIGHT 77 DOOR AND FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOUTION CAN BESUBSTITUTED FOR NEW DOORS. WALL TYPES PLAN NOTES ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS (A0), STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. A02 PROVIDE PLYWOOD PHONE BOARD, 4'x8'xy", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. A03 NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE PROVIDED BY TENANT AND INSTALLED ACCORDING TO NFPA 10. PROVIDE3-0 X B'-0" DRYWALL WRAPPED OPENING AT THIS aoa LOCATION. PROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR A05 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. P01 PROVIDE POTABLE HOTAND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. P02 PROVIDE COPPER WATER LINE (POLYTUBE IS NOT PERMITTED) FOR COFFEE AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. P03 PROVIDE 2.5 GALLON WATER HEATER, NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO Ill UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. 9 WALL WITH INSULATION 35% METALSTUDSAT16"O.C.; METALSTUD ONE LAYER OF S/" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATTINSULAION INSIDE W ALL AN D 2'-0" EACH SIDE OF WALL ABOVE CEILING ❑DEMISING WALL TO DECK WITH INSULATION 3y" METAL STUDS AT 16" O.C.; ONE LAYER OR SSB' TYPE "X' GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATTINSULATION INSIDE WALL )(mil ' T ( EXISTING WIN MULLION WALL THICKNESS 7 PRE -FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT A WALL AT MULLION DETAIL NOT TO SCALE AREA NOT IN CONTRACT ARCHITECTURAL PLAN N AREA OF WORK 0 2' 4' 8' 16' THIS DRAWING, AND THE IDEAS, RESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. — LLI c� V 0 Q NED O Z QO Q A/ LU J LLJ LLJ oz Z �? Q Z--J W V) Z Q n_ 0 ~ � ZLu LU 7 ISSUE DATE DESCRIPTION 11.27.18 REVIEW SEF 12.06.18 PERMITSET EVISONS ARK =iiiiiiiim No. 70 AR10700017 , STATE OF �. PROJECT NUMBER 2018.415 PROD. MGR DRAWN BY AS CB 2ND FLOOR DEMOLITION PLAN/ ARCHITECTURAL FLOOR PLAN �A111 ELECTRICAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX MOUNTED OCEILING JUNCTION BOX ® BOX, BLANK COVER PLAT ® BOX, OPEN P POWER POLE FOR 6 ELECTRICAL AND DATA. PROVIDE JUNCTION BOX ABOVE CEILING. FLOOR BOX WITH POWER 0EI® AND DATA, FLUSH MOUNTED FLOOR BOX WITH ® JUNCTION BOX AND DATA, FLUSH MOUNTED DATA/COMMUNICATION q OUTLET (PROVIDE BOX AND PULL STRING ONLY( DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42" HEIGHT OF ELECTRICAL OR DATA DEVICE POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX J O JUNCTION BOX O CEILING MOUNTED JUNCTION BOX Q BOX, BLANK COVER PLATE Q BOX,OPEN PO POWER AND DATA POLE FLOOR BOX WITH POWER �q AND DATA, FLUSH MOUNTED FLOOR BOX WITH J q JUNCTION BOX AND DATA, FLUSH MOUNTED q DATA/COMMUNICATION OUTLEr ELECTRICAL PLAN NOTES E01 PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. HARDWARE, CABLING, CONNECTIONS AND ACTIVATION BY TENANTS VENDOR. E02 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE E03 SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET E04 INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 60" A.F.F. E06 PROVIDE POWER AND DATA AT 66" A.F.F. FOR TENANTS WALL MOUNTED TELEVISION. COORDINATE EXACT LOCATION WITH TENANT. E06 PROVIDE POWER FOR UNDER SINK WATER HEATER. AREA NOT IN CONTRACT RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 02/18/19 GENERAL ELEC. NOTES I. TENANTS FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. RELOCATE EXISTING OUTLETS AT SAME HEIGHT AS NEW IF THERE IS A VARIANCE. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAN -LOCKS. ALL ELECTRICAL AND MAGNETIC HARDWARE AND CONNECTIONS i0 BE COMPLETED BY TENANT'S SECURITY VENDOR. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. ELECTRICAL PLAN 0 2' 4' 8' 16, CEILING LEGEND NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 2'x4', M NIGHT FIXTURE, 2'x4', INDIRECT LED INDIRECT LED ® LIGHT FIXTURE, @ NIGHT FIXTURE, PENDANT `LY PENDANT IN INDICATES NIGHT LIGHT INDICATES NIGHT LIGHT LOCATION LOCATION ® JOfEXITUGHTFIXTURE ® EXIT LIGHT FIXTURE ® EMERGENCYLIGHT © EMERGEN CY LIGHT FIXTURE FIXTURE $N LIGHT SWITCH LIGHT SWITCH CEILING GRID, _i I� CEILING GRID, SUSPENDED, 2'x2' - __T__�_ SUSPENDED, 2'#' ❑EXISTING/RELOCATED ® DIFFUSER, LAWN, 2'#' DIFFUSER, LAY IN, 2 x2 EXISIING/RELOCATED ® DIFFUSER, LAY IN, 4'x4' ® DIFFUSER, LAWN, 4Ss4' NOTE: IF IN GOOD CONDITION, EXISTING HN A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET, GENERAL RCP NOTES L REUSE EXISTING CEILING GRID UNLESS OTHERWISE NOTED, EXISTING GRID IS 2x2 AT B'-5" A.F.F. 2. PROVIDE NEW 2X2 ARMSTRONG DUNE ACOUSTICAL LAY IN CEILING TILES THROUGHOUT. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. UNLESS NOTED OTHERWISE. THE LIGHTS SHOWN AS "NEW OR RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATION AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENT IS LESS THAN 50%OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90. 1, CONTRACTOR MUST NOTIFY SDI. 5. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE. 6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTISWITCHPLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL CONTRACTOR IS TO NOTIFY APPUCABLI PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. AREA NOT IN CONTRACT AREA OF WORK MECHANICAL NOTES MECHAN ICAL W ORK IS LIMITED 70 A DESIGN FBUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED: MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 2. HVAC LAYOUT TO BE APPROVED PRIOR TO WORK BEING COMPLETED. FILTERS MUST BE CHANGED AT CLOSE OF PROJECT AND ALL THERMOSTATS MUST BE CALIBRATED AND AIR BALANCED- PROVIDE REPORT TO OWNER. RCP PLAN NOTES R01 CONTROL OPEN OFFICE AREA LIGHTING WITH SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. RELOCATE DIFFUSERS & MECHANICAL DIFFUSER RELOCATION *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION REFLECTED CEILING PLAN 0 2' 4' 8' 16, N THIS DRAWING, AND THE IDEAS, IESIG NS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT 0FSCHOTT DESIGN. W N VQ ZQ aZoz_ Q141 N w w ZN ZU Z��Q W Vi Z Q 0 0 ~ � WZow CL W LU LU 7 ZQ N0. AR10700017 STATE OF PROJECT NUMBER 2018.415 DRAWN BY CB 2ND FLOOR ELECTRICAL PLAN/ REFLECTED CEILING PLAN A121 LEGEND FLOOR COVERINGS CARPET CPT1 MFG: TBD TYPE: PATTERN: — COLOR: -- EDCPT2 MFG: TBD TYPE: PATTERN: — COLOR: -- VINYL COMPOSITION TILE VCTI MFG: TBD SIZE: 12XI2" PATTERN: — COLOR: — LUXURY VINYL TILE LVTI MFG: TBD SIZE: PATTERN: — COLOR: — NOTE: PROVIDE SKIMCOAT OF ARDEX LEVELING LATEX AS NEEDED FOR SMOOTH SUBFLOOR THAT WILL NOT ALLOW FOR TELEGRAPHING OF IMPERFECTIONS IN THE FLOOR VB1 MFG: TBD TYPE: 4" VINYL COVEY" GAUGE COLOR: -- PAINT / WALLCOVERING PTI MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: -- FINISH: EGGSHELL PT2 MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: — FINISH: EGGSHELL PT3 MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: — FINISH: EGGSHELL PLASTIC LAMINATE / SOLID SURFACE pLT I MFG: TBD (COUNTERTOP) COLOR: — pL2 MFG: TBD (CABINETS) COLOR: -- SST MFG: TBD COLOR: — 5S2 MFG TBD COLOR: — ALL FINISHES TO BE SELECTED. FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel DATE: 02/18/19 PLAN NOTES F01 PROVIDE JOHNSONITE SLIMLINE SLT-XX-F PROFILE TRANSITION STRIP AT FLOORING TRANSITION; COLOR: TBD. CONTRACTOR MUST PROVIDE LEVELING LATEX SUCH THAT HEIGHTS OF MATERIALS ARE APPROPRIATE FOR USE WITH SPECIFIED PROFILE TRANSITION. BE AWARE TRANSITION STRIP MUST BE ORDERED IN A TIMELY MANNER AS IT IS NOT ALWAYS IMMEDIATELY AVAILABLE. _ TO EK6PNG STACK I k'I�V CO I �CLC Iy2 v. i I I I I I-EXET NK 4V, T W. NOTE: REFER TO FLOORPLAN �\ \T� AND CASEWORK ELEVATORS FOR SINK LOCATIONS. EXIST Y To 4W, BUILDING DRAIN RISER DIAGRAM A211 TYPICAL ALL SINGLE LOCATIONSMOT TO SCALE FAAREA NOT IN CONTRACT ❑ AREA OF WORK CASEWORK NOTES GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF BASE CABINET PRIOR TO ORDERING. I. PROVIDE A.W.I. CUSTOM GRADE, FLUSH -OVERLAY CABINETS. FABRICATE WITH PLASTIC LAMINATE (PL2) COVERED M.D.O. BOARD WITH MOCKETT DP3B-4 PULLS, FINISH: SATIN CHROME. COORDINATE WITH ELEVATIONS FOR QUANTITIES. -AT BREAK ROOM PROVIDE: 24" DEEP COUNTERTOPS 23" DEEP BASE CABINETS I1� DEEP (INTERIOR CLEAR DIMENSION)UPPER CABINETS FINISH PLAN 0 2' 4' 8' 16, DOOR SCHEDULE NS DOOR FRAME HARDWARE REM. TYPE MATERIAL FINISH TYPE MATERIAL FINISH %y' t3G'x8'-G'x1Yq' D3 SOLID CORE BIRCH VNR. TBD F2 TIMELY ALUMATONE CR, ES, $L, CL R1 %q' D3 SOLID CORE BIRCH VNR. TBD F2 TIMELY ALUMATONE PS D1 SOLID CORE BIRCH VNR. TBD F1 TIMELY ALUMATONE SL 06 3'-0'X8'-9'W%' D3 SOLID CORE BIRCH VNR. TBD F1 TIMELY ALUMATONE PS 07 3'-9'x8'-9'x0%1 D1 SOLID CORE BIRCH VNR. TBD F2 TIMELY ALUMATONE PS REMARKS RI. PROVIDE SEPARATE PRICE FOR DOOR TYPE D3 IN THIS LOCATION. PROVIDE NEW ELECTROMAGNETIC LOCK IF ACCEPTED. INSURE THAT NEW DOOR MATCHES HEIGHT AND FINISH OF EXISTING COMMON CORRIDOR DOORS, DOOR/FRAME TYPES HARDWARE LEGEND U O 0 N 0 y 0 0 O L1_tt D1 8'3ii'iT'll 11�11 a Q / PROVIDE ONE PULL ON h t EACH SIDE OF DOOR BE ��� (TOTAL COUNT 2) i0 O MATCH BUILDING 0 STANDARD D \ \ b D2 FF— REFMG. BY TENANT IL---- F2 3'V' D3 b STAINED TO LAATCH DOOR (SEE CASEWORK NOTE 1) ]a" DEEP PVSTIC IAMINATE (PL_I COUNTERTOP WITH 4" n HIGH BACKSPLASH �� rTT. AAAAAAAY(SEE CASEWORK NOTE 1) 6J 2U 2 V (HOLD) �2 ELEVATION - BREAK ROOM 204 0 1' 2' 4' rRatat✓ CL CLOSER CH COATHOOK CR CARD READER BY TENANT(N.I.C.) DB DEADBOLT DL DUMMY LEVER EL ELECTROMAGNETIC LOCK (PER IBC 2012) ES ELECTRIC STRIKE BY TENANT(N.LC.) H HOLD OPEN KP KICK PLATE KS KICK STOP OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES DOOR/FRAME NOTES I. REUSE DOORS FROM DEMOLITION WHERE POSSIBLE; TOUCH UP EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO MATCH EXISTING. PRE -MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE GRADE MINIMUM BUILDING STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED, 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: • T-0" HT. TO HAVE 3 HINGES • GREATER THAN 70 IN HT. TO HAVE 4 HINGES • FINISH TO MATCH HARDWARE SET 8. PROVIDE(1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE)AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. TO' 1'-7' 24 T < L 2•4 L 2•4' 1 2•"4• (SEE CASEWORK NOTE II SINGLE BOWL SINK: 18 GAUGE STAINLESS STEEL, 25'MI%"WIT H KOHLER SIMPLICE FAUCET #K-597 (OR EQUAL), AND GARBAGE DISPOSAL B 24" DEEP PLASTIC LAMINATE PLI I COUNTERTOP WITH 4" HIGH BACK SPLASH (SEE CASEWORK NOTE II n ELEVATION - BREAK ROOM 204 A211 0 1' 2' 4' mat✓ THIS DRAWING, AND THE IDEAS, RESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PART, WRHOUT THE WR77EN CONSENT OFSCHOTT DESIGN- W (V V0 ZQ azNIT oz aU')- N uJ w ZZNJ Q WV)z0 ZLLJ On= W LU W z L Za aaaaaK ISSUE DATE DESCRIPTION 11.27.18 REVIEW SET 12.06.18 PERMITSET EVISONS ARK DATE DB DESCRIPTION No. 70 AR10700017 , STATE OF TFRED PRD� PROJECT NUMBER 2018.415 PROD. MGR DRAWN BY A�tl — 2ND FLOOR FINISH PLAN DOOR SCHEDULE INTERIOR DETAILS A211