HomeMy WebLinkAboutA 001R RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City ooffl Cannel (� �VT \DwV.'A1DA�L DATE: 02/20/19 REFLECTED CEILING SYMBOLS SUSPENDED LAY IN CEILING SYSTEM ROOM NUMBER ACOUSTICAL CEILING TILE TYPE CEILING HEIGHT ABOVE FINISH FLOOR RECESSED CAN LIGHT FIXTURE OR PENDANT CEILING MOUNTED EXIT LIGHT CUBICLE CURTAIN TRACK AND CURTAIN 2'x4' LIGHTING FIXTURE 2'x2' LIGHTING FIXTURE VxC LIGHTING FIXTURE RETURN AIR GRILLE EXHAUST AIR GRILLE SUPPLY AIR GRILLE 12" DEEP SOUNDSTAR CEILING SYSTEM (DC2) GYPSUM CONTROL JOINT ACCESS PANEL GYPSUM WALLBOARD BULKHEADICEILING WOOD CEILING CC1) GENERAL REFLECTED CEILING NOTES A, ALL LAY IN ACOUSTICAL CEILINGS SHALL BE INSTALLED TO MATCH EXISTING HEIGHT, UNLESS NOTED OTHERWISE. B. ALL LAY IN ACOUSTICAL CEILINGS SHALL BE TYPE ACTT, UNLESS NOTED OTHERWISE, C. ALL GYPSUM WALLBOARD BULKHEADS SHALL BE INSTALLED AT 9' 0" ABOVE FINISH FLOOR, UNLESS NOTED OTHERWISE. D, REFER TO SHEET At 30 FOR TYPICAL BULKHEAD DETAIL, E. INSTALL CONTROL JOINTS IN GYPSUM BOARD WALLS, CEILINGS AND BULKHEADS AS INDICATED ON THE DIMENSION, REFLECTED CEILING PLANS, INTERIOR ELEVATIONS AND PER SPECIFICATION DIVISION 09. ELEVATION SYMBOL LEGEND XX NEW COLUMN LINE SIM SECTION INDICATOR 101 AREA DETAIL INDICATOR rA DE I DETAIL NUMBER 1 BIM SIMILAR 101 SHEET NUMBER 1 402 2 ELEVATION TAG 3 00 ELEVATION NOTE DESIGNATION GENERAL ELEVATION NOTES A. REFER FLOOR PLANS 6 THE EQUIPMENT SCHEDULE FOR EQUIPMENT TYPES. REFER TO MiEIP DRAWINGS TO COORDINATE CONNECTIONS. B. REFER TO PLU MBI NG PLAN S FOR S IN K TYPES. C. ALL DIMENSIONS ARE TAKEN TO THE FACE OF FINISHED MATERIAL. D. INSTALL BLOCKING TO STUDS TO SUPPORT ALL WALL MOUNTED CABINETRY AND EQUIP ME NT AS REQUIRED. E, C ONTRACTOR TO F IELD VER IFY A ILL DI MEN S ION S PRI OR TO CONSTRUCTING CABINETRY. F. COORDINATE BULKHEAD HEIGHTS INDICATED HERE WITH THAT SHOWN ON THE REFLECTED CEILING PLAN. CONFIRM ANY DISCREPANCIES WITH THE ARCHITECT PRIOR TO CONSTRUCTION. G. COORDINATE ALL WALL OUTLETS TO AVOID CONFLICT WITH CASEWORK B COUNTERTOPS, H. COORDINATE SUPPORT BRACKET LOCATIONS WITH INDICATED UNDER COUNTER EQUIPMENT. ALL PATTERNED LAMINATES SHALL RUN VERTICAL. (UNO( J. ALL NON LAB BASE CABINETS SHALL BE 2' 0" DEEP UNLESS NOTED OTHERWISE. K. ALL NON LAB CASEWORK SHALL BE FINISHED IN PLASTIC LAMINATE UNLESS NOTED OTHERWISE. REFER TO LAB SHEETS FOR LAB CASEWORK. L, PROVIDE FILLER PANELS AT ALL LOCATIONS WHERE CABINETRY ABUTS A WALL. M. PROVIDE A 4" HIGH INTEGRAL BACK SPLASH ON ALL COUNTERS WITH RECESSED SINKS. INSTALL SIDE SPLASHES WHERE THESE COUNTERS ABUT A WALL. N. PROVIDE ADJUSTABLE SHELVING WITHIN ALL WALL AND BASE CABINETRY AS SHOWN BY DASHED LINE, 0, BOTTOM OF UPPER CABINETS TO BE FINISHED TO MATCH VERTICAL FACES. ARCHITECTURAL SYMBOLS LEGEND XX — - — - — - NEW COLUMN LINE SIM 101 SECTION INDICATOR a' AREA I` DETAIL INDICATOR OF x DETAIL NUMBER _DETTAIL 1 SIM SIMILAR 101 SHEET NUMBER ROOM ROOM NA ME DESIGNATION L22LJ ROOM NUMBER DESIGNATIi 00 PLAN NOTE DESIGNATION 000 EQUIPMENT DESIG NATION, REFER TO EQUIPMENT SCHEDULE. ® FLOOR DRAIN 1 4 0 2 ELEVATION TAG 3 00 TOILET ACCESSORY F,E,C,f FIRE EXTINGUISHER AND CABINET GENERAL ARCHITECTURAL NOTES A. REFERTO THE EQUIPMENT SCHEDULE ON THIS SHEET FOR EQUIPMENT INFORMATION. COORDINATE BLOCKING AND MEP CONNECTIONS AS REQUIRED. B. PROVIDE 18" MINIMUM ADA REQUIRED CLEARANCE ADJACENT TO STRIKE OF DOOR. C. PAINTING CONTRACTOR SHALL LABEL, ABOVE CEILING, ALL FIRE RATED WALL CONSTRUCTION AND SMOKE BARRIER WALL CONSTRUCTION IN ACCORDANCE WITH SPECIFICATION. D. REUSE ALL EXISTING SALVAGED WOOD DOORS FROM DEMOLITION AS APPLICABLE. REFER TO DOOR SCHEDULE FOR REUSED LOCATIONS. E DASHED IN FURNITURE FOR REFERENCE ONLY. F, EXISTING MINI BLINDS AT EXTERIOR WINDOWS TO REMAIN, REPLACE ANY DAMAGED BLINDS TO MATCH EXISTING. DIMENSION PLAN SYMBOLS LEGEND XX 1 EXISTING COLUMN LINE BIM SECTION INDICATOR 101 AREA DETAILINDICATOR OF E AI DETAIL NUMBER 1 SIM SIMILAR 101 SHEET NUMBER ROOM ROOM NAME DESIGNATION FO-00-1 ROOM NUMBER DESIGNATION ® PLAN NOTE DESIGNATION WALL TYPE WALL TYPE SUFFIX U.N.O. f� 101 DOOR NUMBER DESIGNATION PUSH PLATE FOR AUTO IPP DOOR OPERATOR CARD READER FOR ELECTRIC CR — DOOR LATCH BOTTOM OF STRUCTURE BOTTOM OF STRUCTURE BOTTOM OF STRUCTURE DEFLECTION TRACK _T 112" SEALANT SPACE DEFLECTION TRACK 112" SEALANT SPACE (FIRESTOP SYSTEM AT RATED PARTITIONS( FASTEN GYPSUM BOARD FASTEN GYPSUM BOARD TO STUDS NOT TO THE TO STUDS NOT TO THE TOPTRACK TOP TRACK FINISH CEILING (REFER TO REFLECTED CEILING PLAN( HEAD SECTION DETAIL HEAD SECTION DETAIL HEAD SECTION DETAIL VARIES — VPRIES� VARIES �VARIE F1 1112"WALL F2 2118"WALL 32 2 112" METAL STUDS VARIES 62 3314"WALL A2 .2 112" METAL STUDS VARIES A3 3 518" METAL STUDS 8. A2.3118"WALL A3 4114"WALL B3 3518"METAL STUDS B3-4718"WALL Ft 718" FURRING CHANNEL F3 2118 WALL B6 6"METALSTUDS 518' 8' Be 7114"WALL A6 6"METAL STUDS A6 6518"WALL F2 1 1I2" "Z" FURRING CHANNEL F3 1 112" FURRINGCHANNEL GYPSUM BOARD GYPSUM BOARD ADJACENT WALL CONSTRUCTION BASE BASE BASE ((RpEpFEER�TT;OG FINISH STEEL STUD RUNNER (REFERTO FINISH DRAWINGS) STEEL STUD RUNNER (REFERTO FINISH DRAWINGS) F LOOR SLAB TRACK . STUDS SCREWED TRACK STUDS SCREWED FINIBH FCObRING ON EA. SIDE AT BOTTOM FINISH FLOORING AT BOTTOM FINISH FLOORING (REFERTO FINISH (REFERTO FINISH DRAWINGS( REFERTO FINISH DRAWINGS( D2S SEAL"EALA TSPACE FLOOR SLAB 1I2"SEALANT SPACE FLOOR SLAB 112"SEALANT SPACE RESTOAT RATED PARTITIONS) S( BASE SECTION DETAIL BASE SECTION DETAIL BASE SECTION DETAIL FURRING CHANNEL METALSTUDS ALSTUDS (REFER TO BASE SECTION DETAIL( (REFER TO BASE SECTION ERTO BASE SECTION DETAIL( GYPSUMBOARD DETAIL( *��OEU GYPSUM BOARD ON NO ATTENUATION EACH SIDE OF STUDS BATTS ADJACENT WALL SOUND ATTENUATION BATTS PLAN DETAIL CONSTRUCTION PLAN DETAIL PLAN DETAIL Fx NONRATED BX MINIMUM STC 1HOUR RATED PARTITION (WHERE NOTED ON PLANK. AX NONRATED B2 UL#V401 I B3 UI#U465 I B6 UL#U425 B2 45 1 B3 45 1 B6 45 DEMOLITION SYMBOLS LEGEND XX EXISTING COLUMN LINE 00 DEMOLITION NOTE DESIGNATION EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED of is EXISTING DOOR AND FRAME TO REMAIN EXISTING DOOR AND FRAME TO BE REMOVED 1� WALL TYPE SYMBOL x1Ax ~ SUFFIX INDICATES HORIZONTAL MODIFICATIONS SUFFIXINDICATESI NTEATION (CATIONS TO WALL CONSTRUCTION HEIGHT NUMERISTUDIMCALINDICZE OF STUDIMASONRY SIZE INDICATES CONSTRUCTION TYPE GENERAL WALL TYPE NOTES EXIST I NG WIN DOW AND FRAME TO IA' REMAIN OMMMUMI -- EXISTING WINDOW AND FRAME TO BE REMOVED B GENERAL DEMOLITION NOTES A. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND TEMPORARY DOORS AS DEEMED NECESSARY BY THE ARCHITECT, ENGINEER AND OWNER. THEY SHALL BE WELL MAINTAINED AND ANY DAMAGE REPAIRED IMMEDIATELY TO AVOID MIGRATION OF DUST INTO ADJOINING AREAS. B, EXISTING WALL, FLOOR, CEILINGS, AND CASEWORK FINISHES TO REMAIN SHALL BE PROTECTED AND ANY DAMAGE RESULTING FROM DEMOLITION WORK SHALL BE REPAIRED. C. WHEN DEMOLITION CAUSES DAMAGE TO FLOOR, WALL OR CEILING SURFACES THAT WILL REMAIN EXPOSED IN THE FINISHED WORK, SUCH DAMAGE SHALL BE REPAIRED AS REQUIRED TO RECEIVE NEW FINISHES. D. THE CONTRACTOR SHALL COVER AND PROTECT OWNER'S EQUIPMENT WHICH CANNOT BE REMOVED FROM THE PROJECT AREA. E. WHERE EXTERIOR WALLS, DOORS ANDIOR WINDOWS ARE TO BE REMOVED OR MODIFIED, THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THAT THE EXISTING BUILDING REMAINS SECURE, WEATHER -TIGHT, AND WITHOUT DRAFTS, F. MAKE ALL DEMOLITION CLEAN AND COMPLETE AND IN MANNER SU (TABLE TO ACCEPT NEW FINISHES ANDIOR SURFACES. G. REMOVE ALL EXISTING WALL MOUNTED ITEMS WITHIN THE PROJECT LIMIT AREA WHICH ARE NOT NOTED TO REMAIN. THE CONTRACTOR SHALL DISPOSE OF THESE ITEMS AFTER INSPECTION BY THE OWNER FOR FUTURE USE, IF ITEMS ARE REMOVED FROM WALLS THAT ARE TO REMAIN, THE CONTRACTOR SHALL PATCH WALLS AS REQUIRED TO RECEIVE NEW FINISHES ANDIOR SURFACES. H. DEMOLITION FOR BUILDING SERVICES AND UTILITIES SHALL BE PERFORMED BY THE TRADE RESPONSIBLE FOR THAT UTILITY, FOR EXAMPLE, PLUMBING FIXTURES SHALL BE DEMOLISHED BY THE MECHANICAL CONTRACTOR. OPENINGS FOR DEMOLISHED UTILITIES SHALL BE INFILLED BY TRADE RESPONSIBLE FOR PIPING, DUCT OR CONDUIT DEMOLITION. OPENINGS THROUGH FIRE RATED CONSTRUCTION SHALL BE PATCHED TO MATCH EXISTING CONSTRUCTION OR BE FIRESTOPPED. I. REMOVE EXISTING FLOOR AND BASE MATERIALS IN ALL AREAS SCHEDULED TO RECEIVE NEW FLOOR AND BASE. REFER TO FINISH DRAWINGS OR SCHEDULES. REMOVE FLOOR AND BASE ADHESIVES AND PREPARE SURFACES AS REQUIRED TO RECEIVE NEW FINISHES. MAKE DEMOLITION CLEAN AND COMPLETE INA MANNER SUITABLETO ACCEPT NEW FINISHES ANDIOR SURFACES. J. REMOVE EXISTING WALL FINISHES ON ALL WALLS SCHEDULED TO RECEIVE NEW FINISHES, REFERTOFINISH DRAWINGS FOR LOCATIONS OF NEW FINISHES. REMOVE EXISTING WALL COVERINGS AND ADHESIVES. PREPARE WALL SURFACES AS DETAILED IN SPECIFICATIONS. K. EXISTING MINI BLINDS TO REMAIN. PROTECTAS NECESSARY TO PREVENT DAMAGE. REFERTO GENERAL FINISH NOTES ON SHEET IF001. C. D. E. F. G H DIMENSIONS IN PLAN AND ELEVATION ARE TAKEN TO THE FACE OF FINISH GYPSUM WALLBOARD, FACE OF EXPOSED MASONRY, CONCRETE, OR CENTER LINE OF COLUMN, UNLESS NOTED OTHERWISE. ALL INTERIOR WALLS SHALL BE TYPE'BT UNLESS NOTED OTHERWISE, ALL COLUMN SURROUNDS SHALL BE WALL TYPE'AZ UNLESS NOTED OTHERWISE. PROVIDE FULL HEIGHT STRUCTURAL STUDS TO THE STRUCTURE ABOVE AT ALL CORNERS, AT DOOR AND BORROWED LIGHT FRAMES, ANDJAMBS. FURNISH AND INSTALL FIRE STOP SEALANT WHERE GYPSUM WALL BOARD MEETS FIREPROOFING ON COLUMNS, BEAMS, AND METAL DECK AT FIRE RATED PARTITIONS. ALL PENETRATIONS THROUGH FIRE AND SMOKE RATED WALLS SHALL BE FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS. AT FIRE RATED WALLS, PROVIDE TESTED FIRE STOPPING SYSTEM AT HEAD OF WALL. AT ALL NON FIRE RATED WALLS, INCLUDING SOUND RESISTANT WALLS, SMOKE PARTITIONS AND CORRIDOR WALLS, PACK VOID SPACE BETWEEN METAL DECK FLUTES AND TOP OF PARTITION WITH FIRE SAFING AND SEAL GAP AT GYPSUM WALLBOARD WITH ACOUSTICAL SEALANT. ALL WALLS SHALL BE TREATED AS SOUND RESISTANT WALLS (UNLESS NOTED OTHERWISE(. SEAL AROUND ALL PENETRATIONS AND INSTALL SOUND ATTENUATION BATTS FULL HEIGHT, FIT INSULATION TIGHT AROUND DUCT AND PIPE PENETRATIONS. ALL SOUND RESISTANT WALLS WITH SOUND ATTENUATION BATTS SHALL HAVE ACOUSTICAL SEALANT UNDER BOTTOM RUNNER TRACK. INSTALL CONTROL JOINTS IN GYPSUM BOARD WALLS, CEILINGS AND BULKHEADS AS INDICATED ON THE DIMENSION, REFLECTED CEILING PLANS, INTERIOR ELEVATIONS AND PER SPECIFICATION DIVISION 09, ALL STUDS SHALL BE AT 16" O.C. UNLESS NOTED OTHERWISE. WALL TYPES SUFFIX 1. INDICATES GYPSUM WALL CONSTRUCTION TO STOP 6" ABOVE FINISHED CEILING, STUD CONSTRUCTION TO CONTINUE TO DECK. 2. INDICATES GYPSUM BOARD ON ONE SIDE TO STOP 6" ABOVE FINISHED CEILING. 3. INDICATES ENTIRE WALL CONSTRUCTION TO STOP 6" ABOVE FINISHED CEILING, 4. INDICATES PARTIAL HEIGHT WALL. a. INDICATES NO SOUND ATTENUATION BLANKETS c. INDICATES 112" 4'x8' SHEETS OF FIRE RETARDANT PLYWOOD APPLIED TO TELECOM. SIDE OFROOM. APPLY TO A HEIGHT OF 3'-0" A.F.F. d INDICATES ADDITIONAL LAYER OF 518" GYPSUM BOARD OVER WALL. e. INDICATES FOIL FACED GYPSUM BOARD. PARTITION PRIORITY LEGEND PARTITION FIRE RATING (AS NOTED( PRIORITY i7:U1T1:�71:7i8:\:7:71i:�5g:111 2 HOUR FIRE BARRIER WALL 2 1 HOUR FIRE BARRIER WALL 3 SMOKE BARRIER 4 SMOKE PARTITION 5 NON RATED PARTITION 6 PARTITION PRIORITY DIAGRAMS G YPSUM BOARD CONTINUES THROUGH STUD SPACE OF HIGHER LOWER PRIORITY 1 PRIORITY PARTITION \: PARTITION BSA BSA LifeStructures 9365 Counselors Row Suite 300 Indianapolis, IN 46240.1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com VISIONFIRST Indiana Lions Eye Bank OFFICE AND LAB RENOVATION CLIENT PROJECT NO. - 21160001 CONSTRUCTION DOCUMENTS LOWER PRIORITY PARTITION EM GYPSUM BOARD CONTINSTUDS ES SPACE STUD SPACE OF LOWER PRIORITY tl KEYPLAN LOWER PRIORITY PARTITION PARTITION I vuNNORTH HIGHER PRIORITY PARTITION GYPSUM BOARD CONTINUES THROUGH HIGHER STUD SPACE OF PRIORITY P LOWER PRIORITY �:- LOWER PRIORITY PARTITION MARK _ DATE I DESCRIPTION 13 No.`° AR10500148 STATE OF GENERAL NOTES & SYMBOLS (DATE DEC. 19, 2018 BSALS PROJECT NO. 21160001 A001