HomeMy WebLinkAboutA 001R
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City
ooffl Cannel (�
�VT \DwV.'A1DA�L
DATE: 02/20/19
REFLECTED CEILING SYMBOLS
SUSPENDED LAY IN CEILING SYSTEM
ROOM NUMBER
ACOUSTICAL CEILING TILE TYPE
CEILING HEIGHT ABOVE FINISH FLOOR
RECESSED CAN LIGHT FIXTURE OR PENDANT
CEILING MOUNTED EXIT LIGHT
CUBICLE CURTAIN TRACK AND CURTAIN
2'x4' LIGHTING FIXTURE
2'x2' LIGHTING FIXTURE
VxC LIGHTING FIXTURE
RETURN AIR GRILLE
EXHAUST AIR GRILLE
SUPPLY AIR GRILLE
12" DEEP SOUNDSTAR CEILING
SYSTEM (DC2)
GYPSUM CONTROL JOINT
ACCESS PANEL
GYPSUM WALLBOARD BULKHEADICEILING
WOOD CEILING CC1)
GENERAL REFLECTED CEILING NOTES
A, ALL LAY IN ACOUSTICAL CEILINGS SHALL BE INSTALLED TO
MATCH EXISTING HEIGHT, UNLESS NOTED OTHERWISE.
B. ALL LAY IN ACOUSTICAL CEILINGS SHALL BE TYPE ACTT,
UNLESS NOTED OTHERWISE,
C. ALL GYPSUM WALLBOARD BULKHEADS SHALL BE INSTALLED
AT 9' 0" ABOVE FINISH FLOOR, UNLESS NOTED OTHERWISE.
D, REFER TO SHEET At 30 FOR TYPICAL BULKHEAD DETAIL,
E. INSTALL CONTROL JOINTS IN GYPSUM BOARD WALLS,
CEILINGS AND BULKHEADS AS INDICATED ON THE
DIMENSION, REFLECTED CEILING PLANS, INTERIOR
ELEVATIONS AND PER SPECIFICATION DIVISION 09.
ELEVATION SYMBOL LEGEND
XX
NEW COLUMN LINE
SIM
SECTION INDICATOR
101
AREA
DETAIL INDICATOR
rA
DE I
DETAIL NUMBER
1 BIM
SIMILAR
101
SHEET NUMBER
1
402 2
ELEVATION TAG
3
00
ELEVATION NOTE DESIGNATION
GENERAL ELEVATION NOTES
A. REFER FLOOR PLANS 6 THE EQUIPMENT SCHEDULE FOR EQUIPMENT
TYPES. REFER TO MiEIP DRAWINGS TO COORDINATE CONNECTIONS.
B. REFER TO PLU MBI NG PLAN S FOR S IN K TYPES.
C. ALL DIMENSIONS ARE TAKEN TO THE FACE OF FINISHED MATERIAL.
D. INSTALL BLOCKING TO STUDS TO SUPPORT ALL WALL MOUNTED
CABINETRY AND EQUIP ME NT AS REQUIRED.
E, C ONTRACTOR TO F IELD VER IFY A ILL DI MEN S ION S PRI OR TO
CONSTRUCTING CABINETRY.
F. COORDINATE BULKHEAD HEIGHTS INDICATED HERE WITH THAT
SHOWN ON THE REFLECTED CEILING PLAN. CONFIRM ANY
DISCREPANCIES WITH THE ARCHITECT PRIOR TO CONSTRUCTION.
G. COORDINATE ALL WALL OUTLETS TO AVOID CONFLICT WITH
CASEWORK B COUNTERTOPS,
H. COORDINATE SUPPORT BRACKET LOCATIONS WITH INDICATED
UNDER COUNTER EQUIPMENT.
ALL PATTERNED LAMINATES SHALL RUN VERTICAL. (UNO(
J. ALL NON LAB BASE CABINETS SHALL BE 2' 0" DEEP UNLESS NOTED
OTHERWISE.
K. ALL NON LAB CASEWORK SHALL BE FINISHED IN PLASTIC LAMINATE
UNLESS NOTED OTHERWISE. REFER TO LAB SHEETS FOR LAB
CASEWORK.
L, PROVIDE FILLER PANELS AT ALL LOCATIONS WHERE CABINETRY
ABUTS A WALL.
M. PROVIDE A 4" HIGH INTEGRAL BACK SPLASH ON ALL COUNTERS WITH
RECESSED SINKS. INSTALL SIDE SPLASHES WHERE THESE
COUNTERS ABUT A WALL.
N. PROVIDE ADJUSTABLE SHELVING WITHIN ALL WALL AND BASE
CABINETRY AS SHOWN BY DASHED LINE,
0, BOTTOM OF UPPER CABINETS TO BE FINISHED TO MATCH VERTICAL
FACES.
ARCHITECTURAL SYMBOLS LEGEND
XX
— - — - — -
NEW COLUMN LINE
SIM
101
SECTION INDICATOR
a'
AREA
I`
DETAIL INDICATOR
OF
x
DETAIL NUMBER
_DETTAIL
1 SIM
SIMILAR
101
SHEET NUMBER
ROOM
ROOM NA ME DESIGNATION
L22LJ
ROOM NUMBER DESIGNATIi
00
PLAN NOTE DESIGNATION
000
EQUIPMENT DESIG NATION,
REFER
TO EQUIPMENT SCHEDULE.
®
FLOOR DRAIN
1
4 0
2 ELEVATION TAG
3
00 TOILET ACCESSORY
F,E,C,f FIRE EXTINGUISHER AND CABINET
GENERAL ARCHITECTURAL NOTES
A. REFERTO THE EQUIPMENT SCHEDULE ON THIS SHEET FOR
EQUIPMENT INFORMATION. COORDINATE BLOCKING AND MEP
CONNECTIONS AS REQUIRED.
B. PROVIDE 18" MINIMUM ADA REQUIRED CLEARANCE ADJACENT
TO STRIKE OF DOOR.
C. PAINTING CONTRACTOR SHALL LABEL, ABOVE CEILING, ALL
FIRE RATED WALL CONSTRUCTION AND SMOKE BARRIER WALL
CONSTRUCTION IN ACCORDANCE WITH SPECIFICATION.
D. REUSE ALL EXISTING SALVAGED WOOD DOORS FROM
DEMOLITION AS APPLICABLE. REFER TO DOOR SCHEDULE FOR
REUSED LOCATIONS.
E DASHED IN FURNITURE FOR REFERENCE ONLY.
F, EXISTING MINI BLINDS AT EXTERIOR WINDOWS TO REMAIN,
REPLACE ANY DAMAGED BLINDS TO MATCH EXISTING.
DIMENSION PLAN SYMBOLS LEGEND
XX 1
EXISTING COLUMN LINE
BIM
SECTION INDICATOR
101
AREA
DETAILINDICATOR
OF
E AI
DETAIL NUMBER
1 SIM
SIMILAR
101
SHEET NUMBER
ROOM
ROOM NAME DESIGNATION
FO-00-1
ROOM NUMBER DESIGNATION
®
PLAN NOTE DESIGNATION
WALL TYPE
WALL TYPE SUFFIX
U.N.O.
f�
101
DOOR NUMBER DESIGNATION
PUSH PLATE FOR AUTO
IPP
DOOR OPERATOR
CARD READER FOR ELECTRIC
CR —
DOOR LATCH
BOTTOM OF STRUCTURE
BOTTOM OF STRUCTURE
BOTTOM OF STRUCTURE
DEFLECTION TRACK
_T
112" SEALANT SPACE
DEFLECTION TRACK
112" SEALANT SPACE
(FIRESTOP SYSTEM AT
RATED PARTITIONS(
FASTEN GYPSUM BOARD
FASTEN GYPSUM BOARD
TO STUDS NOT TO THE
TO STUDS NOT TO THE
TOPTRACK
TOP TRACK
FINISH CEILING
(REFER TO REFLECTED CEILING
PLAN(
HEAD SECTION DETAIL
HEAD SECTION DETAIL
HEAD SECTION DETAIL
VARIES —
VPRIES�
VARIES
�VARIE
F1 1112"WALL
F2 2118"WALL
32 2 112" METAL STUDS
VARIES
62 3314"WALL
A2 .2 112" METAL STUDS VARIES
A3 3 518" METAL STUDS
8. A2.3118"WALL
A3 4114"WALL
B3 3518"METAL STUDS
B3-4718"WALL
Ft 718" FURRING CHANNEL
F3 2118 WALL
B6 6"METALSTUDS 518'
8' Be 7114"WALL
A6 6"METAL STUDS
A6 6518"WALL
F2 1 1I2" "Z" FURRING CHANNEL
F3 1 112" FURRINGCHANNEL
GYPSUM BOARD
GYPSUM BOARD
ADJACENT WALL CONSTRUCTION
BASE
BASE
BASE
((RpEpFEER�TT;OG FINISH
STEEL STUD RUNNER
(REFERTO FINISH DRAWINGS)
STEEL STUD RUNNER
(REFERTO FINISH DRAWINGS)
F LOOR SLAB
TRACK . STUDS SCREWED
TRACK STUDS SCREWED
FINIBH FCObRING
ON EA. SIDE AT BOTTOM
FINISH FLOORING
AT BOTTOM
FINISH FLOORING
(REFERTO FINISH
(REFERTO FINISH DRAWINGS(
REFERTO FINISH DRAWINGS(
D2S
SEAL"EALA TSPACE
FLOOR SLAB
1I2"SEALANT SPACE
FLOOR SLAB
112"SEALANT SPACE
RESTOAT RATED
PARTITIONS)
S(
BASE SECTION DETAIL
BASE SECTION DETAIL
BASE SECTION DETAIL
FURRING CHANNEL
METALSTUDS
ALSTUDS
(REFER TO BASE SECTION DETAIL(
(REFER TO BASE SECTION
ERTO BASE SECTION DETAIL(
GYPSUMBOARD
DETAIL(
*��OEU
GYPSUM BOARD ON
NO ATTENUATION
EACH SIDE OF STUDS
BATTS
ADJACENT WALL
SOUND ATTENUATION BATTS
PLAN DETAIL
CONSTRUCTION
PLAN DETAIL
PLAN DETAIL
Fx
NONRATED
BX
MINIMUM STC
1HOUR
RATED PARTITION (WHERE NOTED ON PLANK.
AX
NONRATED
B2 UL#V401
I B3 UI#U465 I B6 UL#U425
B2 45 1 B3 45 1 B6 45
DEMOLITION SYMBOLS LEGEND
XX EXISTING COLUMN LINE
00 DEMOLITION NOTE DESIGNATION
EXISTING WALL TO REMAIN
EXISTING WALL TO BE REMOVED
of is EXISTING DOOR AND FRAME TO
REMAIN
EXISTING DOOR AND FRAME TO BE REMOVED
1�
WALL TYPE SYMBOL
x1Ax ~ SUFFIX INDICATES HORIZONTAL
MODIFICATIONS
SUFFIXINDICATESI NTEATION (CATIONS TO WALL
CONSTRUCTION HEIGHT
NUMERISTUDIMCALINDICZE OF
STUDIMASONRY SIZE
INDICATES CONSTRUCTION TYPE
GENERAL WALL TYPE NOTES
EXIST I NG WIN DOW AND FRAME TO IA'
REMAIN
OMMMUMI -- EXISTING WINDOW AND FRAME TO BE REMOVED
B
GENERAL DEMOLITION NOTES
A. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY
PARTITIONS AND TEMPORARY DOORS AS DEEMED
NECESSARY BY THE ARCHITECT, ENGINEER AND OWNER.
THEY SHALL BE WELL MAINTAINED AND ANY DAMAGE
REPAIRED IMMEDIATELY TO AVOID MIGRATION OF DUST
INTO ADJOINING AREAS.
B, EXISTING WALL, FLOOR, CEILINGS, AND CASEWORK
FINISHES TO REMAIN SHALL BE PROTECTED AND ANY
DAMAGE RESULTING FROM DEMOLITION WORK SHALL BE
REPAIRED.
C. WHEN DEMOLITION CAUSES DAMAGE TO FLOOR, WALL OR
CEILING SURFACES THAT WILL REMAIN EXPOSED IN THE
FINISHED WORK, SUCH DAMAGE SHALL BE REPAIRED AS
REQUIRED TO RECEIVE NEW FINISHES.
D. THE CONTRACTOR SHALL COVER AND PROTECT OWNER'S
EQUIPMENT WHICH CANNOT BE REMOVED FROM THE
PROJECT AREA.
E. WHERE EXTERIOR WALLS, DOORS ANDIOR WINDOWS ARE
TO BE REMOVED OR MODIFIED, THE CONTRACTOR SHALL
TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THAT THE
EXISTING BUILDING REMAINS SECURE, WEATHER -TIGHT,
AND WITHOUT DRAFTS,
F. MAKE ALL DEMOLITION CLEAN AND COMPLETE AND IN
MANNER SU (TABLE TO ACCEPT NEW FINISHES ANDIOR
SURFACES.
G. REMOVE ALL EXISTING WALL MOUNTED ITEMS WITHIN THE
PROJECT LIMIT AREA WHICH ARE NOT NOTED TO REMAIN.
THE CONTRACTOR SHALL DISPOSE OF THESE ITEMS AFTER
INSPECTION BY THE OWNER FOR FUTURE USE, IF ITEMS
ARE REMOVED FROM WALLS THAT ARE TO REMAIN, THE
CONTRACTOR SHALL PATCH WALLS AS REQUIRED TO
RECEIVE NEW FINISHES ANDIOR SURFACES.
H. DEMOLITION FOR BUILDING SERVICES AND UTILITIES SHALL
BE PERFORMED BY THE TRADE RESPONSIBLE FOR THAT
UTILITY, FOR EXAMPLE, PLUMBING FIXTURES SHALL BE
DEMOLISHED BY THE MECHANICAL CONTRACTOR.
OPENINGS FOR DEMOLISHED UTILITIES SHALL BE INFILLED
BY TRADE RESPONSIBLE FOR PIPING, DUCT OR CONDUIT
DEMOLITION. OPENINGS THROUGH FIRE RATED
CONSTRUCTION SHALL BE PATCHED TO MATCH EXISTING
CONSTRUCTION OR BE FIRESTOPPED.
I. REMOVE EXISTING FLOOR AND BASE MATERIALS IN ALL
AREAS SCHEDULED TO RECEIVE NEW FLOOR AND BASE.
REFER TO FINISH DRAWINGS OR SCHEDULES. REMOVE
FLOOR AND BASE ADHESIVES AND PREPARE SURFACES AS
REQUIRED TO RECEIVE NEW FINISHES. MAKE DEMOLITION
CLEAN AND COMPLETE INA MANNER SUITABLETO ACCEPT
NEW FINISHES ANDIOR SURFACES.
J. REMOVE EXISTING WALL FINISHES ON ALL WALLS
SCHEDULED TO RECEIVE NEW FINISHES, REFERTOFINISH
DRAWINGS FOR LOCATIONS OF NEW FINISHES. REMOVE
EXISTING WALL COVERINGS AND ADHESIVES. PREPARE
WALL SURFACES AS DETAILED IN SPECIFICATIONS.
K. EXISTING MINI BLINDS TO REMAIN. PROTECTAS
NECESSARY TO PREVENT DAMAGE. REFERTO GENERAL
FINISH NOTES ON SHEET IF001.
C.
D.
E.
F.
G
H
DIMENSIONS IN PLAN AND ELEVATION ARE TAKEN TO THE FACE OF
FINISH GYPSUM WALLBOARD, FACE OF EXPOSED MASONRY,
CONCRETE, OR CENTER LINE OF COLUMN, UNLESS NOTED
OTHERWISE.
ALL INTERIOR WALLS SHALL BE TYPE'BT UNLESS NOTED
OTHERWISE, ALL COLUMN SURROUNDS SHALL BE WALL TYPE'AZ
UNLESS NOTED OTHERWISE.
PROVIDE FULL HEIGHT STRUCTURAL STUDS TO THE STRUCTURE
ABOVE AT ALL CORNERS, AT DOOR AND BORROWED LIGHT FRAMES,
ANDJAMBS.
FURNISH AND INSTALL FIRE STOP SEALANT WHERE GYPSUM WALL
BOARD MEETS FIREPROOFING ON COLUMNS, BEAMS, AND METAL
DECK AT FIRE RATED PARTITIONS.
ALL PENETRATIONS THROUGH FIRE AND SMOKE RATED WALLS
SHALL BE FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS.
AT FIRE RATED WALLS, PROVIDE TESTED FIRE STOPPING SYSTEM AT
HEAD OF WALL. AT ALL NON FIRE RATED WALLS, INCLUDING SOUND
RESISTANT WALLS, SMOKE PARTITIONS AND CORRIDOR WALLS,
PACK VOID SPACE BETWEEN METAL DECK FLUTES AND TOP OF
PARTITION WITH FIRE SAFING AND SEAL GAP AT GYPSUM
WALLBOARD WITH ACOUSTICAL SEALANT.
ALL WALLS SHALL BE TREATED AS SOUND RESISTANT WALLS
(UNLESS NOTED OTHERWISE(. SEAL AROUND ALL PENETRATIONS
AND INSTALL SOUND ATTENUATION BATTS FULL HEIGHT, FIT
INSULATION TIGHT AROUND DUCT AND PIPE PENETRATIONS. ALL
SOUND RESISTANT WALLS WITH SOUND ATTENUATION BATTS SHALL
HAVE ACOUSTICAL SEALANT UNDER BOTTOM RUNNER TRACK.
INSTALL CONTROL JOINTS IN GYPSUM BOARD WALLS, CEILINGS AND
BULKHEADS AS INDICATED ON THE DIMENSION, REFLECTED CEILING
PLANS, INTERIOR ELEVATIONS AND PER SPECIFICATION DIVISION 09,
ALL STUDS SHALL BE AT 16" O.C. UNLESS NOTED OTHERWISE.
WALL TYPES SUFFIX
1. INDICATES GYPSUM WALL CONSTRUCTION TO STOP 6" ABOVE
FINISHED CEILING, STUD CONSTRUCTION TO CONTINUE TO DECK.
2. INDICATES GYPSUM BOARD ON ONE SIDE TO STOP 6" ABOVE
FINISHED CEILING.
3. INDICATES ENTIRE WALL CONSTRUCTION TO STOP 6" ABOVE
FINISHED CEILING,
4. INDICATES PARTIAL HEIGHT WALL.
a. INDICATES NO SOUND ATTENUATION BLANKETS
c. INDICATES 112" 4'x8' SHEETS OF FIRE RETARDANT PLYWOOD
APPLIED TO TELECOM. SIDE OFROOM. APPLY TO A HEIGHT OF 3'-0"
A.F.F.
d INDICATES ADDITIONAL LAYER OF 518" GYPSUM BOARD OVER WALL.
e. INDICATES FOIL FACED GYPSUM BOARD.
PARTITION PRIORITY LEGEND
PARTITION FIRE RATING (AS NOTED( PRIORITY
i7:U1T1:�71:7i8:\:7:71i:�5g:111
2 HOUR FIRE BARRIER WALL
2
1 HOUR FIRE BARRIER WALL
3
SMOKE BARRIER
4
SMOKE PARTITION
5
NON RATED PARTITION
6
PARTITION PRIORITY DIAGRAMS
G YPSUM BOARD
CONTINUES THROUGH
STUD SPACE OF HIGHER
LOWER PRIORITY 1 PRIORITY
PARTITION \: PARTITION
BSA
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240.1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
VISIONFIRST
Indiana Lions Eye Bank
OFFICE AND
LAB
RENOVATION
CLIENT PROJECT NO. - 21160001
CONSTRUCTION
DOCUMENTS
LOWER PRIORITY
PARTITION EM
GYPSUM BOARD
CONTINSTUDS ES SPACE
STUD SPACE OF
LOWER PRIORITY
tl KEYPLAN
LOWER PRIORITY
PARTITION
PARTITION
I vuNNORTH
HIGHER PRIORITY
PARTITION
GYPSUM BOARD
CONTINUES THROUGH HIGHER
STUD SPACE OF PRIORITY
P
LOWER PRIORITY �:-
LOWER PRIORITY
PARTITION
MARK _ DATE I DESCRIPTION
13 No.`°
AR10500148
STATE OF
GENERAL NOTES &
SYMBOLS
(DATE DEC. 19, 2018
BSALS PROJECT NO. 21160001
A001