E 001
t ELECTRICAL EQUIPMENT SYMBOL DESCRIPTION MOLDED CASE CIRCUIT BREAKER CURRENTTRANSFORMER dil, GROUND CONNECTION • GROUND POINT ® GROUND ROD O' LIGHTNING PROTECTION AIR TERMINAL ❑X PAD MOUNTED TRANSFORMER('X' DENOTES KVA SIZE) tat BRANCH PANELBOARD AND CABINET - RECESSED MOUNT BRANCH PANELBOARD AND CABINET - SURFACE MOUNT DISTRIBUTION PANELBOARD AND CABINET - SURFACE MOUNT O ELECTRIC THERMOSTAT .O' MOTOR('X' DENOTES HORSEPOWER) PF CAPACITOR(�X' DENOTES KVAR) x 0' DISCONNECT SWITCH - FUSED O' DISCONNECT SWITCH -NON-FUSED ® MOTOR CONTROLLER ®' COMBINATION MOTOR CONTROLLER O JUNCTION OR PULL BOX CH0 PUSHBUTTON OR PUSH PLATE O GENE RATORIALTE RNATOR AUTOMATIC TRANSFER SWITCH SYMBOL DESCRIPTION DUPLEX RECEPTACLE - NORMAL CIRCUIT ('X' DENOTES AS FOLLOWS:) pp DUPLEX RECEPTACLE - EMERGENCY 4 CIRCUIT('X' DENOTES AS FOLLOWS:) ,µ QUADRAPLEX RECEPTACLE - NORMAL F CIRCUIT('%' DENOTES AS FOLLOWS:) QUADRAPLEX RECEPTACLE - EMERGENCY CIRCUIT('X' DENOTES AS FOLLOWS:) SIMPLEX RECEPTACLE - NORMAL CIRCUIT('X' DENOTES AS FOLLOWS:) SIMPLEX RECEPTACLE - EMERGENCY CIRCUIT('X' DENOTES AS FOLLOWS:) NONE -20 AMP, 125VAC GFCI -20 AMP, 125VAC, GROUND FAULT CURRENT INTERRUPTER TYPE HIM -20 AMP, 125VAC, HORIZONTAL MOUNT TYPE IG - 20 AMP, 125VAC, ISOLATED GROUND TYPE S -20 AMP, 125VAC, SURGE GUARD PROTECTION TYPE ST- 20 AMP, 125VAC, SAFETY TYPE WP -20 AMP, 125VAC, WEATHERPROOF TYPE SPECIAL RECEPTACLE -NORMAL CIRCUIT (SEE DRAWINGS AND SPECIFICATIONS) SPECIAL RECEPTACLE - EMERGENCY CIRCUIT (SEE DRAWINGS AND SPECIFICATIONS) ®M ® DUPLEX -CEILING MOUNTED WW QUADRAPLEX-CEILING MOUNTED ® [j] FLOOR BOX (DUPLEX) ® ® FLOOR BOX (QUADRAPLEX) FLOOR BOX (BLANK) ® FLOOR BOX (POWER AND DATA) WvVvW PLUGSTRI P(POWE R AND/OR DATA) $ TOGS LE SWITCH- 20 AMP, 120277VAC 3$ TOGS LE SWITCH - &WAY 4$ TOGO LE SWITCH-4-WAY P $ TOGG LE SWITCH - PI LOT LIG HT K $ TOGS LE SWITCH - KEY OPERATED D$ I NDIVIDUAL LI GHT DI MMER $a LETTER DESIGNATION INDICATES SWITCH LEG $T HORSEPOWER RATED MANUAL MOTOR STARTER TOGGLE SWITCH WITH THERMAL OVERLOAD PROTECTION TELEVISION SYSTEM SYMBOL DESCRIPTION © TV SYSTEM OUTLET ® AUDIO/VISUAL CONTROLLER FP FLAT PANEL TV WITH RECESSED WALL BOX CLOCK SYSTEM SYMBOL DESCRIPTION 'V WALL MOUNTED CLOCK FO DI GITAL TIME CLOCKIE LAPSE D TIME SYSTEM OUTLET RACEWAY SYSTEM SYMBOL DESCRIPTION PHASE q�tDl9liF TpRs c6 D L-GROUND QUANTITY OF CONDUCTORS OR CABLES IN CONDUIT `NEUTRAL FIRE ALARM SYSTEM SYMBOL DESCRIPTION SO SMOKE DETECTOR("(' DENOTES AS FOLLOWS) x R - RE JAY BASE HD HEAT DETECTOR FD FLAME DETECTOR DO DUCT DETECTOR('X' DENOTES AS FOLLOWS) S-SUPPLY R-RETURN AR ADDRESSABLE RELAY RI REMOTE INDICATOR STATION RT REMOTE TEST STATION BD BEAM DETECTOR ❑M MANUAL PULL STATION FS FLOW SWITCH TS TAMPER SWITCH IT�n� HORN ONLY - WALL MOUNT Ls HORN STROBE -WALL MOUNT C❑J CHI ME ONLY - WALL MOUNT DO CHI ME STROBE - WALL MOUNT M SPEAKER ONLY - WALL MOUNT E10 SPEAKER STROBE -WALL MOUNT BELL ONLY - WALL MOUNT M11 BE LL STROBE - WALL MOUNT IEY VISUAL ON LY - WALL MOUNT H HORN ONLY -CE I LI NO MOUNT H HORN STROBE -CE I LING MOUNT C CHIME ONLY -CEI LI NG MOUNT C CHI ME STROBE -CE I LING MOUNT S SPEAKER ONLY -CEI LI NG MOUNT SPEAKER STROBE -CE I LING MOUNT BE LL ONLY -CEILING MOUNT B B BELL STROBE - CEILING MOUNT V VISUAL ON LY -CE ILI NG MOUNT DH DOOR HOLD OPEN I] ADDRESSABLE MODULE FFkpl FIRE ALARM CONTROL PANEL EFMP1 FIRE ALARM ANNUNCIATOR PANEL FANP FIRE ALARM NOTIFICATION APPLIANCE PANEL FFATC51 FIRE ALARM TERMINAL CABINET FGC_d FIRE ALARM GRAPHICS COMMAND CENTER FT FIREMEN'S TELEPHONE ® RESCUE ASSISTANCE STATION (AREA OF REFUGE) SYMBOL DESCRIPTION '® MICROPHONE INPUT RECEPTACLE - WALL MOUNTED 0 MICROPHONE INPUT RECEPTACLE - FLOOR MOUNTED ® MICROPHONE INPUT RECEPTACLE - CEILING MOUNTED ® WALL MOUNTED PAGING HORN SPEAKER (ROUGH -IN) © LOUDSPEAKER - CEILING MOUNTED ©v LOUDSPEAKER- CEILING MOUNTED WITH VOLUME CONTROL LOUDSPEAKER - WALL MOUNTED ❑V VOLUME CONTROL FLOOR PLAN SYMBOLS SYMBOL DESCRIPTION O PLAN NOTE A. GENERAL NOTE LIGHTING SYMBOL DESCRIPTION 12N48' LIGHT FIXTURE IIIIII� HALF SHADED INDICATES UNSWITCHED NIGHT LIGHTS 24'A24' LIGHT FIXTURE 24' WALL LIGHTS Q WALL MOUNTED SCONCE LIGHT 24t48' FIXTURE 0 DOWN LIGHT WALL AND CEILING MOUNTED EMERGENCY BATTERY LIGHT } } EXIT LIGHT DIRECTIONAL ARROWS ■ CEILING MOUNTED EXIT LIGHT (DUAL FACED) CEILING MOUNTED EXT LIGHT HO WALL MOUNTED EXIT LIGHT -0 EXTERIOR POLE LIGHTS (SINGLE HEADS) O.O EXTERIOR POLE LIGHTS (DOUBLE HEADS) OW EXTERIOR POLE LIGHTS (THREE HEADS) + EXTERIOR POLE LIGHTS (FOUR HEADS) 0 EXTERIOR POLE LIGHTS (POLE TOP MOUNT) } EXTERIOR LIGHTS (BOLLARDS) GROUND FLOOD LIGHT 0 EXTERIOR FLOOD LIGHT LC LIGHTING CONTROLLER O MOTION DETECTOR (LIGHT SWITCH) ® OCCUPANCY SENSOR -WALL MOUNTED © OCCUPANCY SENSOR -CEILING MOUNTED VS VACANCY SENSOR - WALL MOUNTED Q VACANCY SENSOR -CEILING MOUNTED © PHOTOCELL -WALL MOUNTED © PHOTOCELL -CEILING MOUNTED TELECOMMUNICATION SYSTEM SYMBOL DESCRIPTION • LIFE SAFDETY TELEPHONE LINE (POTS) vW VOICE ONLY OUTLET (WALL OUTLET) 0 DATA ONLY OUTLET WAP v WIRELESS ACCESS POINT 71 FLOOR BOX (VOICE, DATA, VOICEIDATA) ®PRO) AP ® CEILING MOUNTED (DATA, VOICEIDATA) TELECOMMUNICATIONS EQUIPMENT RACK SECURITY SYSTEM SYMBOL DESCRIPTION MTV CCTV MONITOR OUTLET % DOOR BUZZER ® ELECTRIC DOOR RELEASE BUTTON ES ELECTRIC DOOR STRIKE IC INTERCOM UNIT FLUSH MOUNTED © INTERCOM -CEILING MOUNTED MI MASTER INTERCOM AND DIRECTORY UNIT SCP SECURITY CONTROL PANEL © SECURITY MAGNETIC DOOR LOCK ® SECURITY CARD READER ®K COMBINATION CARD READERWITH KEYPAD ® MOTION DETECTOR -WALL MOUNTED MO MOTION DETECTOR -CEILING MOUNTED ® SECURITY DOOR CONTACTS p6 SECURITY EXIT PUSH BUTTON ® SECURITY MONITOR REX SECURITY DOOR REQUEST TO EXIT MOTION DETECTOR KP SECURITY KEYPAD IS S BIOSCAN ACCESS PAD DURESS ALARM (HOLD UP BUTTON) ® ELECTRIC POWER TRANSFER © PUSH PLATE TA TOUCHLESS ACTUATOR PB DOOR RELEASE PUSH BUTTON PB DOOR POWER SUPPLY =33 CAMERA CAMERA - EXTERIOR EXT CAMERA. PANITILT200M PTZ DO AUTO DOOR OPERATION LINE SYMBOLS —/— LIGHTISCREENED SOLID OR DASHED LINES INDICATE EXISTING TO REMAIN — — — HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED HEAVY CONTINUOUS LINES INDICATE NEW WORK —SZ— HEAVY CONTINUOUS LINES INDICATE SPRINKLERZONE ELECTRICAL ABBREVIATIONS ABBREV. DESCRIPTION ABBREV. DESCRIPTION A orAMP AMPERE HZ HERTZ AC ALTERNATING CURRENT IC INTERCOMMUNICATION A/C AIR CONDTIONING ID INSIDE DIAMETER ACP ACCESSPANEL INCAN INCANDESCENT ACU AIR CONDITIONING UNIT INCL INCLUDE ADD ADDTION ISG ISOLATED GROUND SURGE GUARD ADJ ADJUSTABLE JB JUNCTION BOX AF AMPERE FRAME JT JOINT AFC ABOVE FINISHED CEILING KEC KITCHEN EQUIPMENT CONTRACTOR AFF ABOVE FINISHED FLOOR KT KITCHENETTE AFG ABOVE FINISHED GRADE KVA KILOVOLT AMPERE AHU AIR HANDLING UNIT KVAR KILOVOLT AMPERE REACTIVE AIC AMPERE INTERRUPTING CAPACITY KW KILOWATT AL ALUMINUM LAB LABORATORY AM AMMETER LB POUND AMB AMBIENT LF LINEAR FEET APPROX, APPROXIMATELY LOC LOCATION ARCH ARCHITECT LS LIFE SAFETY ATS AUTOMATIC TRANSFERSWITCH LT LIGHT AUTO AUTOMATIC LTG LIGHTING AVG AVERAGE LV LOWVOLTAGE BC BARE COPPER MATV MASTER ANTENNA TELEVISION BKR BREAKER MAX MAXIMUM BHP BRAKE HORSEPOWER MC MECHANICAL CONTRACTOR BL BUILDING LINE MCB MAIN CIRCUIT BREAKER BLDG BUILDING MCC MOTOR CONTROL CENTER BR BRANCH MDP MAIN DISTRIBUTION PANEL BTM BOTTOM MECH MECHANICAL C CONDUIT MH MANHOLE °C DEGREES CELSIUS MIN MINIMUM CAB CABINET MISC MISCELLANEOUS CB or CIB CIRCUIT BREAKER MLO MAIN LUGS ONLY CJC CENTER TO CENTER MTD MOUNTED CCTV CLOSED CIRCU IT TELEVISION MTG HT MOUNTING HEIGHT CKT CIRCUIT MU MEDICINE UNIT CL CENTERLINE OD OUTSIDE DIAMETER CLG CEILING OFCI OWNER FURNISHED -CONTRACTOR INSTALLED COL COLUMN OFOI OWNER FURNISHED -OWNER INSTALLED Comm COMMUNICATION OPNG OPENING COMP COMPRESSOR OPP OPPOSITE CONIC CONCRETE OR OPERATING ROOM CONST CONSTRUCTION P POLE CONT CONTINUOUS PB PUSHBUTTON CONTR CONTRACTOR PBOX PULL BOX CR CRITICAL PE PNEUMATIC ELECTRIC CONVERTER CT CURRENT TRANSFORMER PF POWER FACTOR CU COPPER PH or PHASE DB DIRECT BURIAL PV POST INDICATORVALVE DC DIRECT CURRENT PNL PANELBOARD DEPT DEPARTMENT PL PILOT LIGHT DF DRINKING FOUNTAIN PREFAB PREFABRICATED DIST DISTRIBUTION PRIES PRESSURE DM DEMAND METER PT PNEUMATIC TUBE DO DRAWOUT PTS PNEUMATIC TUBE STATION DRS DOCTORS PW PART WINDING DWG DRAWING PWR POWER EC ELECTRICAL CONTRACTOR RACU ROOM AIR CONDITIONING UNIT EF EXHAUST FAN RAD RADIATION ELEC ELECTRIC RECEPT RECEPTACLE ELEV ELEVATOR REF or REFR REFRIGERATOR ELV ELEVATION REINF REINFORCED EMER EMERGENCY RGIP REMOTE GROUND INDICATING PANEL ENCL ENCLOSURE RM ROOM EP ELECTRIC PNEUMATIC RPM REVOLUTIONS PER MINUTE EQUIP EQUIPMENT SA SUPPLYAIR EWC ELECTRIC WATER COOLER SC SHORT CIRCUIT EX EXPLOSIONPROOF SG SURGE GUARD PROTECTION EXH EXHAUST BHT SHEET EXP EXPANSION SIG SIGNAL EXT EXTERIOR SN SOLID NEUTRAL OF DEGREES FAHRENHEIT SPEC SPECIFICATIONS FA FIRE ALARM SO SQUARE FAAP FIRE ALARM ANNUNCIATOR PANEL SS SAFETY SWITCH FACP FIRE ALARM CONTROL PANEL SSSS SOLID STATE SOFT START PC FLAT CABLE STD STANDARD FCU FAN COIL UNIT STN STATION FFC FOOD FACILITY CONTRACTOR STR STRUCTURAL FFS FOOD FACILITY SUPPLIER SUSP SUSPENDED FHC FIRE HOSE CABINET SW SWITCH FIN FINISH SWBD SWITCHBOARD FIXT FIXTURE SWGR SWITCHGEAR FL FLOOR TCC TEMPERATURE CONTROL CONTRACTOR FLUOR FLUORESCENT TELE TELECOMMUNICATION FLEX-CONN FLEXIBLE CONNECTION TEMP TEMPERATURE FPC FIRE PROTECTION CONTRACTOR TMH TOP OF MANHOLE FSS FUSED SAFETY SWITCH TV TELEVISION FTG FOOTING TYP TYPICAL FVR FILMVIEWER UC UNDER CARPET FV FULL VOLTAGE UIC UNDER CABINET or UNDER COUNTER FVNR FULLVOLTAGE NON REVERSING UH UNIT HEATER G or GND GROUND UV UNITVENTILATOR GALV GALVANIZED V VOLT GC GENERAL CONTRACTOR VAC VACUUM GEN GENERATOR VB VACUUM BREAKER GFCI GROUND FAULT CKT. INTERRUPTER VC VACUUM CLEANING GFI GROUND FAULT INTERRUPTER VEL VELOCITY GFP GROUND FAULT PROTECTION VFD VARIABLE FREQUENCY DRIVE HGT HEIGHT VM VOLTMETER HH MNDHOLE VOL VOLUME HID HIGH INTENSITY DISCHARGE VP VAPORPROOF HO HAND OPERATED VSDNFC VARIABLE SPEED DRIVE/CONTROLLER HOA HAND -OFF -AUTOMATIC WI WITH HORZ HORIZONTAL WIO WITHOUT HP HORSEPOWER WTR WATER FPS HIGH PRESSURE SODIUM WP WEATHERPROOF HTR HEATER WT WEIGHT HV HIGH VOLTAGE XFMR TRANSFORMER Z IMPEDANCE NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT A. REFER TO SHEET HPE SERIES DRAWINGS FOR ADDITIONAL ELECTRICAL SCOPE. B. ALL CONDUITS SHALL BE RUN ABOVE FINISHED FLOOR OF WHICH IT IS SERVING UNLESS OTHERWISE NOTED. CONDUITS ARE NOT PERMITTED TO BE RUN IN CONCRETE SLAB. C. REFER TO ARCHITECTURAL ELEVATIONS AND DETAILS ON ARCHITECTURAL SERIES DRAWINGS FOR ADDITIONAL INFORMATION ON DEVICE LOCATIONS PRIOR TO ROUGH - IN. ADJUST ROUGH -IN LOCATIONS ACCORDINGLY. D. ALL INTERRUPTIONS OF ELECTRICAL SYSTEMS SHALL BE COORDINATED AND SCHEDULED IN ADVANCE WITH THE ARCH ITECTIENG I NEER AND OWNER. REFERTO SPECIFICATIONS FOR RESTRICTIONS AND ADVANCE NOTICE REQUIREMENTS. E. VERIFY TYPE OF CEILING, GRID SYSTEM SPECIFICATIONS(IF APPLICABLE), AND MOUNTING RESTRICTIONS WITH ARCHITECTURAL DISCIPLINE PRIOR TO ORDER FOR LUMINAIRES. F. MOUNTING OF JUNCTION BOXES BACK-TO-BACK IS NOT PERMITTED. G. ELECTRICAL DEVICES INSTALLED ON VERTICAL FIRE RESISTIVE ASSEMBLIES CLASSIFIED AS FIREISMOKE PARTITIONS SHALL BE INSTALLED WITH OPENING ON ONE SIDE ONLY IN EACH FRAMING SPACE, AND THAT OPENING SHALL NOT EXCEED 16 SQUARE INCHES. ALL CLEARANCES BETWEEN SUCH DEVICES AND THE GYPSUM BOARD SHALL BE COMPLETELY FILLED WITH JOINT COMPOUND OR OTHER UL APPROVED MATERIALS. H. WHERE SPACE ALLOCATIONS WITH REGARD TO ELECTRICAL EQUIPMENT ARE NOT ADEQUATE FOR THE SPECIFIED ELECTRICAL EQUIPMENT, THE ENGINEER SHALL BE CONSULTED BEFORE ORDERING THE EQUIPMENT AND ANY INSTALLATION IS PERFORMED. L COORDINATE LOCATIONS OF ALL CEILING MOUNTED ELECTRICAL AND MECHANICAL EQUIPMENT INCLUDING -BUT NOT LIMITED TO -LUMINAIRES, SENSORS, SMOKE DETECTORS, ETC. WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. REFERTO SPECIFICATIONS FOR RESTRICTIONS OF PARTICULAR DEVICE PLACEMENT. J. ALL CONDUIT AND BOXES SHALL BE CONCEALED WITHIN THE WALL CAVITY AND ABOVE THE CEILING SPACE. SURFACE MOUNTED DEVICES WILL NOT BE ALLOWED. K. CONDUIT FLOOR SLEEVES SHALL BE INSTALLED 2-INCHES ABOVE FINISHED FLOOR AND SHALL BE FIRE PROOFED USING APPROVED FIRE RESISTIVE MATERIAL. L. CUTTING AND PATCHING OF WALLSIFLOOR AND CORE DRILL OF WALLIFLOOR FOR ELECTRICAL WORK SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR, DRAB ASSIGNED BY GC. M. CONTRACTOR SHALL BE RESPONSIBLE TO FIREPROOF PENETRATIONS AT SMOKE WALL, FIREISMOKE WALL, AND ROOF PENETRATIONS. N. CONNECT ALL EXIT AND EGRESS LIGHTING WITH 910 WIRING. 0. PROVIDE UNISTRUTANDIOR MISC. IRONIANGLE AS REQUIRED TO INSTAL)/SUPPORT LIGHT FIXTURES, STARTERS, DISCONNECT, PANELBOARD, ETC. P. CONTRACTOR SHALL PROVIDE POWER TO ALL DOORS, SCREENS, SHADES, PROJECTORS, TVS AND OTHER DEVICES REQUIRING POWER FOR OPERATION. REFER TO ARCH ITECTURAL AND SYSTEMS FLOOR PLAN DRAWI NGS FOR LOCATIONS .ALSO REFER TO DOOR HARDWARE SPECIFICATION SECTION AND DRAWINGS FOR DOOR ROUGH -IN DETAILS. BSA BSA LifeStructures 9365 Counselors Row Suite 300 Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www. bsal'rfestructures.00m VISIONFIRST Indiana Lions Eye Bank OFFICE AND LAB RENOVATION CLIENT PROJECT NO. - 21160001 CONSTRUCTION DOCUMENTS F—MARK DATE I DESCRIPTION ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel 1�01NG1 DATE: 02/20/19 DATE DEC. 16, 2013 BSALS PROJECT N0, 21160001 E001