HomeMy WebLinkAboutH 001K HVAC SYMBOLS ® SUPPLY DIFFUSER OR SUPPLY GRILLE INSULATED METAL PANEL (NO AIRFLOW IN SHADED REGION RETURN DIFFUSER OR RETURN GRILLE BOOT TAP OR 45 DEGREE ENTRY FITTING ® EXHAUST DIFFUSER OR EXHAUST GRILLE RUED R (RISE), D (DROP) ARROW IN DIRECTION OF AIR FLOW MANUAL VOLUME DAMPER ACCESS DOOR 'ED FIRE DAMPER WITH ACCESS DOOR., 90 DEGREE ELBOW WITH TURNING VANES 'SO SMOKE DAMPER WITH ACCESS DOOR Q f�•l/ STANDARD RADII US ELBOW WITH CE NTE R RADII US EQUAL TO I-ift TIMES WIDTH OF DUCT. 'FISD FIREISMOKE DAMPER WITH ACCESS DOWR aMD AUTOMATIC MOTOR OPERATED DAMPER INTERNALL Y LINED DUCTWORK O BDD BACKDRAFT DAMPER 207(72'0 FLAT OVAL DUCT (WIDTH X HEIGHT) AD AFMS AIR FLOW MEASURING STATION 18'0 ROUND DUCT MID20'X12' RETANGULAR DUCT (WIDTH X HEIGHT) DUCT TURNED UP (SOLID LINES) SPIN -IN FITTING WITH MANUAL VOLUME DAMPER AND FLEXIBLE DUCT CONNECTION 7-I'C7 DUCT TURNED DOWN (DASHED LINES) MD PLAN VIEW RETURN BRANCH DUCT SECTION FUIFR RETURNG DIFFUSER TA DESIGNATION 'Rp-CFM' CONICAL FITTING 7 GRILLEERTAGNATIO 'RU-CFM' GRILLE TAG DESIGNATION 12'0 ZL'X12' SQUARE -TO -ROUND TRANSITION ®WITH FLEX DUCT PLAN VIEW SUPPLY BRANCH DUCT TO SUPPLY GRI LLEIDI FELBER SECTION 'S#-CFM' DIFFUSER TAG DESIGNATION WITH FLEX S#-CFM' GRILLE TAG DESIGNATION 90 DEGREE TEE (ROUND OR FLAT OVAL ONLY) -'�����I�I DUCT PLAN VIEW EXHAUST BRANCH DUCT TO SECTION EXHAUST GRILLEIDIFFUSER 'ER-CFM' DIFFUSER TAG DESIGNATION TAG DESIGNATION WITH FLEXmE#-CFM'GRILLE =uuuEADUCT >�I SIDWALL SUPPLY, RETURN, OR EXHAUST GRILLE SUPPLY, RETURN, OR EXHAUST SLOT DIFFUSER CONTROLSYMBOLS Tn ORTTT AIRFLOW MEASURING STATION HH HUMIDITY TRANSMITTER TM TURBINEMETER FFS AIRFLCWSWITCH El LOW LIMIT EC El VARIABLE FREQUENCY CONTROLLER THERMOS THERMOSTAT FORMOTOR AL ALARM MS 12016011 MAGNETIC INDUCTIVE FLOW METERSENSOR UPS (SUPPL��UPTED POWER R BACKDRAFT DAMPER (GRAVITY) VP VELOCITY PRESSURE SENSOR BY EC (ELECTRONIC) CO CO2SENSOR El MANUAL SWITCH(ELECTRIC) VS VIBRATION SWITCH 120116011 BY EC ©D MODEM VD VOLUME DAMPER (MANUAL) CS CURRENT SENSOR ®C MOTOR CONTROL CENTER VXT FLOW HNNSMDTTEAIR DISCONNECT SWITCH - FUSED '1 MOTOR STARTER $ 12NN1 BY EDY EC VORTEX SHEDDING FLOW METER DISCONNECT SWITCH - NON -FUSED C OCCUPANCY SENSOR DD DUCT DETECTOR ® OPERATOR'S WORK STATION p0 20 PSIG MAIN CONTROL AIR VS CURRENTTO PNEUMATIC TRANSDUCER ®p OUTDOOR AIR DAMPER PRESSURE GAUGE ES DAMPER END SWITCH (BINARY) p$ OUTDOOR AIR VOLUME PROBE, TRANSDUCER AND MONITOR HC HOLDING COIL DP DIFFERENTIAL PRESSURE pR PNEUMATICRELAY HO HUMIDISTAT(SPACE) SENSOR(ANALOG) pS DIFFERENTIAL PRESSURE SWITCH SENSOR (BINARY) El PRESSURE -ELECTRIC SWITCH SO SWITCH(PHEUMATIC) ES (HL) DIFFERENTIAL PRESSURE SWITCH EC PRESSURE CONTROLLER O THERMOSTAT OR TEMPERATURE (HIGH LIMIT) (BINARY) (PNEUMATIC) SENSOR(SPACE) PS ILL) (LOW LIMIT) (BINARY) ❑p PRESSURE SENSOR THERMOSTAT (SPACE) (ELECTRONIC) NIGHT CYCLE EP ELECTRPPNEUMATIC SWITCH El PRESSURE TRANSMITTER (PNEUMATIC) Q 0.30 PSIG AR GAUGE El El TRANSDUCER TRANSDUCER ®p RETURN AIR DAMPER LAN LOCAL AREA NETWORK READ EXHAUST AIR DAMPER SD SMOKE DETECTOR TCC TEMPERATURE CONTROL CONTRACTOR FBD FACE B BY-PASS DAMPER HIS STARTISTOP SWITCH (NOTE. TCCB ECC ARE USED INTERCHANGEABLY) FDD FAN DISCHARGE DAMPER 04EECC ENVIRONMENTAL CONTROL 12016011 BY EC STEAM FLOW MEASUREMENT ORIFICE PLATE B MASS FLOW COMPUTER CONTRACTOR FID FAN INLET DAMPER EC ELECTRICAL CONTRACTOR FC FLOWCONTROLLER R SUPPLY AIR DAMPER —P— OR PNEUMATIC FS FLOWSENSOR TC OVERRIDE TIMER FOR ELECTRICAL WIRING ®0 HAND -OFF -AUTO SWITCH TC TEMPERATURE CONTROLLER AI-X ANALOGINPUT (PNEUMATIC) (DDC CONTROLLER) TC El HUMIDITY CONTROLLER 0 TEMPERATURE SENSOR AOX ANALOG OUTPUT (PNEUMATIC) (ELECTRONIC) (DDC CONTROLLER) El El(ELECTRIC) HIGH LIMIT TT TEMPERATURE TRANSMITTER BI O BINARY INPUT (ELECTRIC) (PNEUMATIC) (DDC CONTROLLER) HUMIDITYSENSOR TERMINAL BOX ACTUATOR BO-X BINARY OUTPUT (ELECTRONIC) (DDC CONTROLLER) VALVE AND FITTING SYMBOLS PLAN VI EW DETAIL VI EW PIPING FLEXIBLE CONNECTION —0 ---- 0 PIPE TURNED UP (UNLESS NOTED OTHERWISE) D PIPE TURNED DOWN 3& j} �l PIPE OUT TOP A PIPE OUT BOTTOM ,. THREADED NIPPLE WICAP PIPE WITH BLIND FLANGE �I CONCENTRIC REDUCER --11'-- J� ECCENTRIC REDUCER ISOLATION VALVE CHECKVALVE UNION GATE VALVE BALL VALVE GLOBE VALVE BUTTERFLY VALVE $ TEMPERATURE CONTROL-2-WAY MODULATING VALVE TEMPERATURE CONTROL-2-WAY, 2-POSITION ISOLATION VALVE NO TEMPERATURE CONTROL- SWAY MODULATING VALVE TEMPERATURE CONTROL-3-WAY, 2-POSITION ISOLATION VALVE PeA INQ —64— CALIBRATED BALANCE VALVE ( SAFETY RELIEF VALVE V m STRAINER --- N FLOWMETER ® EE ® FLOOR DRAIN BY PC AUTOMATIC FLOW CONTROL VALVE FLOW MEASURING DEVICE MANUAL AIR RELIEF VENT 4' AUTOMATIC AR RELIEF VENT ]— LUBRICATED PLUG VALVE PRESSURE REDUCING VALVE(STEAM, GAS, COMPRESSED AIR) ANGLE VALVE REFRIGERANT HOT GAS BY-PASS VALVE SHUT-OFF COCK(HYDRONICS) SOLENOID VALVE REFRIGERANT EXPANSION VALVE WATER PRESSURE REDUCINGI REGULATING VALVE O STEAM TRAP DIELECTRIC FITTING BETWEEN STEEL AND COPPER to STRAINER (STEAM) P PRESSURE AND TEMPERATURE PLUG REFRIGERANT SIGHT GLASS THERMOMETER P V T (P=PRESS V=VAC T=TEMP)GAUGE QP SENSOR(T-TEMP HHUMIDITY) 8 f FS4 FLOWSWITCH ----390 CLEAN OUT INDICATED EXPANSION LOOP (COLD SPRUNG) ANCHOR GUIDE REFRIGERANT SHUT-OFF VALVE $ EXPANSION JOINT FWrLI DIFFERENTIAL SWITCH peep a*� W�hW REDUCED PRESSURE BACKFLOW PREVENTER O r+1 DOUBLE CHECK VALVE ASSEMBLY [� N FIRE DEPARTMENT CONNECTION f] FIRE PROTECTION CONTROL VALVE FLOOR PLAN SYMBOLS SECTION WITH TOP NUMBER INDICATING 7 TYP SECTION DESIGNATION AND BOTTOM NUMBER A707 INDICATING DRAWING THAT SECTION IS CUT ON OR DRAWING THAT SECTION IS DRAWN ON DETAIL WITH TOP NUMBER INDICATING DETAIL DESIGNATION 7 TYP AND BOTTOM NUMBER INDICATING DRAWING THAT DETAIL A707 IS REFERENCED ON OR DRAWING THAT DETAIL IS DRAWN ON A. GENERAL NOTE 1. PLAN NOTE LIST O PLAN NOTE TO THERMOSTAT HO HUMIDISTAT ® PRESSURE MONITOR (FLOOR PLAN) ®0 CO2 MONITOR (FLOOR PLAN) CONNECTION OF NEW WORK TO EXISTING GENERAL HVAC AND PLUMBING ABBREVIATIONS ABBREV DESCRIPTION ABBREV DESCRIPTION ABBREV DESCRIPTION A/E ARCHITECT AND ENG I NEER GPM GALLONS PER MINUTE PC PRESSURE DROP AD ACCESS DOOR GV GAS, NATURAL VENT POC POINT OF CONNECTION ADJ ADJUSTABLE OR ADJACENT GIN GLASSWARE WASHER PPH POUNDS PER HOUR AFF ABOVE FINISHED FLOOR PPM PARTS PER MILLION APPROX APPROXIMATE H HEIGHT PREFAB PREFABRICATED ARCH ARCHITECT HD HEAD PRIES PRESSURE ATM ATMOSPHERE HGT HEIGHT PRV PRESSURE REDUCING VALVE HOA HAND -OFF -AUTOMATIC PSI POUNDS PER SQUARE INCH BHP BRAKE HORSEPOWER HORZ HORIZONTAL PSIG POUNDS PER SQUARE INCH GAUGE BLDG BUILDING HOSP HOSPITAL PVC POLYVINYL CHLORIDE BOT BOTTOM HE HORSEPOWER BTU BRITISHTHERMAL UNIT HR HOUR RED RECEIVER BTUH BTU PER HOUR HZ HERTZ RECIRC RECIRCULATING REF REFRIGERATOR CAP CAPACITY ID INSIDE DIAMETER OR DIMENSION RLA RUNNING LOAD AMPS CENTRE CENTRIFUGAL IN INCHES RM ROOM CFH CUBIC FEET PER HOUR INCL INCLUDE RPM REVOLUTIONS PER MINUTE CFM CUBIC FEET PER MINUTE INSUL INSULATED CFOI CONTRACTOR FURNISHEDIOWNER INSTALLED INT INTERIOR SA SUPPLY AIR OR SOUND ATTENUATOR CI CASTIRON INV INVERT SCFM STANDARD CUBIC FEET PER MINUTE CO CLEANOUT I.P.S. INTERNATIONAL PIPE SIZING SCH SCHEDULE COL COLUMN SEC SECTION COMP COMPRESSOR JT JOINT SENS SENSIBLE CONC CONCRETE SF SQUARE FOOT CONN CONNECTION KAIC SHORT CIRCUIT RATING BHT SHEET CONST CONSTRUCTION KEC KITCHEN EQUIPMENT CONTRACTOR SPEC SPECIFICATIONS CSP CEILING SERVICE PANEL KW KILOWATTS SO SQUARE SOFT SQUAREFEET DEG DEGREE L LENGTH SRV SAFETY RELIEF VALVE DEPT DEPARTMENT LBS ORR POUNDS SS STAINLESS STEEL DIA DIAMETER LF LINEAR FOOT STD STANDARD DISC DISCONNECT LET LEAVING FLUID TEMPERATURE STR STARTER OR STRUCTURE DISCH DISCHARGE LOC LOCATION STRUC STRUCTURAL DN DOWN LVG LEAVING SW SWITCH DWG DRAWING LWT LEAVING WATER TEMPERATURE SYS SYSTEM EC ELECTRICAL CONTRACTOR MAX MAXIMUM TCC TEMPERATURE CONTROL CONTRACTOR ECC ENVIRONMENTAL CONTROL CONTRACTOR MBH 1000 BTUIHR TDH TOTAL DYNAMIC HEAD EER ENERGY EFFICIENCY RATING MC MECHANICAL CONTRACTOR TEMP TEMPERATURE ELEC ELECTRIC MCA MINIMUM CIRCUIT AMPACITY TILL TEMPERATURE LOW LIMIT ELEV ELEVATION MCC MOTOR CONTROL CENTER TMBH TOTAL MBH EMER EMERGENCY MFR MANUFACTURER TSP TOTAL STATIC PRESSURE ENCL ENCLOSURE MIN MINIMUM TYP TYPICAL ENTR ENTERING MISC MISCELLANEOUS EQUIP EQUIPMENT MODE MAXIMUM OVERCURRENT PROTECTION UNO UNLESS NOTED OTHERWISE ET EXPANSION TANK MTD MOUNTED UVL ULTRA VIOLET LIGHT ETR EXISTING TO REMAIN(DIFFUSEWGRILLE) EMIT ENTERING WATER TEMPERATURE N NORTH VB VACUUM BREAKER EX OR EXIST EXISTING NA NOTAPPLICABLE VEL VELOCITY EXT EXTERIOR NC NORMALLY CLOSED OR NOISE CRITERIA VFC VARIABLE FREQUENCY CONTROLLER NIC NOT IN CONTRACT VSC VARIABLE SPEED CONTROLLER F DEGREESFAHRENHEIT NO NORMALLY OPEN OR NUMBER VTR VENT THROUGH ROOF FC FLEXIBLE CONNECTION NOM NOMINAL FH FUME HOOD NTS NOTTOSCALE W WATTS OR WDTH FIN FINISH Al WITH FLA FULL LOAD AMPS OC ON CENTER NO WITHOUT FLR FLOOR OD OUTSIDE DIAMETER WC WATERCOLUMN FPC FIRE PROTECTION CONTRACTOR OFCI OWNER FURNISHEDICONTRACTOR INSTALLED WFMD WATER FLOW MEASURING DEVICE FT FEET OFOI OWNER FURNISHEDIOWNER INSTALLED WG WATERGAUGE OPER OPERATOR NOT WEIGHT G GAS,NATRUAL DENG OPENING AM WATER METER GA GAUGE ORIG ORIGINAL AP WEATHERPROOF GAL GALLON WPD WATER PRESSURE DROP GALV GALVANIZED P PUMP, PNEUMATIC OR PRESSURE WTR WATER GC GENERAL CONTRACTOR PC PLUMBING CONTRACTOR GH GRAVITY HOOD HVAC ABBREVIATIONS ABBREV. DESCRIPTION ABBREV. DESCRIPTION ABBREV. DESCRIPTION AC OR ACU AI R CONDITION ING UNIT OR Al R COMPRESSOR EG EXHAUST G RI LLE OR ETHYLENE GLYCOL PO PERFORATED DIFFUSER ACCU AIRCOOLED CONDENSING UNIT EMG EXTRUDED METAL GRILLE PE PNEUMATIC ELECTRIC AFCV AIR FLOW CONTROL VALVE ERP ELECTRIC RADIANT PANEL PF PREFILTER$ AIMS AIR FLOW MEASURING STATION ESP EXTERNAL STATIC PRESSURE PG PROPYLENE GLYCOL AHU AIR HANDLING UNIT EUH ELECTRIC UNIT HEATER PHC PREHEAT COIL APO AIR PRESSURE DROP EXH EXHAUST PRO PRESSURE RELIEF DOOR AR AIR RECIEVER PUH PROPELLER UNIT HEATER AS AIRSEPARATOR F&B FACE B BYPASS AVMS AIR VOLUME MEASURING STATION F&T FLOAT AND THERMOSTATIC TRAP RA RETURN AIR OR RELIEF AIR FISD FIRE AND SMOKE DAMPER FAD RADIATED FCU FAN COIL UNIT RAT RETURN AIR TEMPERATURE B BOILER FD FIRE DAMPER FIT REHEAT BCU BLOWER COIL UNIT RF RETURN AIR FAN ROD BACKDRAFT DAMPER H HUMIDIFIER OR HUMIDITY RG RETURN GRILLE BI BACKWARD INCLINE HC HEATING COIL RH RELIEF HOOD OR RELATIVE HUMIDITY BOD BOTTOM OF DUCT HCP HEATING COIL PUMP (HOT WATER) RHC REHEAT COIL HE HEAT EXCHANGER RP RADIANT PANELS CAV CONSTANT AIR VOLUME HP HEAT PUMP RED RETURN PERFORATED GRILLE CC COOLING COIL HER HIGH PRESSURE CONDENSATE RETURN RV ROOF VENTILATOR CCP COOLING COIL PUMP HPS HIGH PRESSURE STEAM CO CONDENSATE DRAIN HRC HEAT RECOVERY COIL SA SUPPLY AIR OR SOUND ATTENUATOR CH CHILLER HTR HEATER SB STEAM BOILER CHIN CHILLED WATER HVAC HEATING, VENTILATION AND AIR CONDITIONING SC STEAM COIL CHAP CHILLED WATER PUMP HIM HOT WATER SCC STEAM CONDENSATE COOLER CP CONDENSATE PUMP HAP HEATING HOT WATER PUMP SCCH SUBCOOLED CHIILER CPD CONDENSATE PUMP DISCHARGE HAP HEATING HOT WATER RETURN SO SUPPLY DIFFUSER OR SMOKE DAMPER CUT CABINET UNIT HEATER HWS HEATING HOT WATER SUPPLY SF SUPPLYAIR FAN CHAR CHILLED WATER RETURN HX HEAT EXCHANGER SG SUPPLY GRILLE CHAS CHILLED WATER SUPPLY SMBH SENSIBLE MBH IFS INTEGRAL FACEAND BYPASS SMC SHEET METAL CONTRACTOR D DIFFUSEROR DAMPER SP STATIC PRESSURE DE DEAERATOR LAN LOCAL AREA NETWORK ST STEAM TRAP DB DECIBELS OR DRY BULB LAT LEAVING AIR TEMPERATURE SV STEAM VENT DC DUCT COIL LBD LINEAR BAR DIFFUSER DD DUAL DUCT LD LINEAR DIFFUSER T THERMOSTAT DDC DIRECT DIGITAL CONTROL LED LAMINAR FLOW DIFFUSER TB TERMINAL BOX DEFL DEFLECTION LET LEAVING FLUID TEMPERATURE TOY TRIPLE DUTYVALVE DUC DOOR UNDER CUT LPR LOW PRESSURE CONDENSATE RETURN TILL TEMPERATURE LOW LI MIT LPS LOW PRESSURE STEAM TSP TOTAL STATIC PRESSURE EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE MAT MIXED AIR TEMPERATURE UH UN IT HEATER EBH ELECTRIC BASEBOARD HEATER MD MOTORIZED DAMPER ECG EGG CRATE GRILLE MECH MECHANICAL VAV VARIABLE AIR VOLUME ED EXHAUST DIFFUSER MPCR MEDIUM PRESSURE CONDENSATE RETURN VD VOLUME DAMPER (MANUAL) EDC ELECTRIC DUCT COIL MPS MEDIUM PRESSURE STEAM EF EXHAUST AIR FAN WB WET BULB EFT ENTERING FLUID TEMPERATURE CA OUTSIDEAIR OAT OUTSIDE AIR TEMPERATURE NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT HVAC PIPING SYMBOLS HWS HEATING WATER SUPPLY ------ iWR— HEATING WATER RETURN PHWS PERIMETER HEATING WATER SUPPLY ­PHWR PERIMETER HEATING WATER RETURN -----CBHWS— CHILLED BEAM HEATING WATER SUPPLY ­CBHWR CHILLED BEAM HEATING WATERRETURN ­CHWS CHILLED WATER SUPPLY —CHWR— CHILLED WATER RETURN ­CBCWS CHILLED BEAM CHILLED WATER SUPPLY -----CBCWR CHILLED BEAM CHILLED WATER RETURN ----- _CWS— CONDENSER WATER SUPPLY CWR CONDENSER WATER RETURN BPS LOW PRESSUR STEAM —CPR— LOW PRESSURE CONDENSATE RETURN SAPS— MEDIUM PRESSURE STEAM APR— MEDIUM PRESSURE CONDENSATE RETURN SIPS— HIGH PRESSURE STEAM ----HPR HIGH PRESSURE CONDENSATE RETURN TC TRAPPED CONDENSATE IN TUNNEL (SYSTEM PRESSURE) SV— STEAM VENT CPO CONDENSATE PUMP DISCHARGE ------GS GLYCOL SUPPLY GR— GLYCOL RETURN �D CONDENSATE B EQUIPMENT DRAIN VFW— BOILER FEED WATER ----- — BWCF— BOILER WATER CHEMICAL FEED ­CWCF CONDENSER WATER CHEMICAL FEED ECWS EQUIPMENT COOLING WATER SUPPLY -----ECWR— EQUIPMENT COOLING WATER RETURN ----iRS HEAT RECOVERY SUPPLY HRR HEAT RECOVERY RETURN ----- —2HG— REFRIGERANT HOT GAS RL REFRIGERANT LIQUID REFRIGERANT SUCTION `— DIRECTION OF PIPE SLOPE (DOWN) LINE SYMBOLS -- — LIGHTISCREENED SOLID OR DASHED LINES INDICATE EXISTING TO REMAIN ---- HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED HEAVY CONTINUOUS LINES INDICATE NEW WORK LIGHT DOT LINES INDICATE FUTURE WORK A. EXISTING SYSTEMS SHOWN ARE BASED ON EXISTING DRAWINGS AND FIELD VERIFIED TO THE EXTENT POSSIBLE. CONTRACTOR SHALL VERIFY THAT SERVICES INDICATED FOR REMOVAL DO NOT SERVE SPACES OUTSIDE THE PROJECT AREA. CONTRACTOR SHALL FIELD VERIFY THAT EXISTING SYSTEMS SHOWN ARE REPRESENTATIVE OF THE INSTALLED SYSTEMS AND REPORT MAJOR DISCREPANCIES TO ENGINEER OF RECORD. B. INACTIVE, ABANDONED SYSTEMS NOT SHOWN ARE TO BE REPORTED TO THE ENGINEER OF RECORD. C. CONTRACTOR IS TO COORDINATE ALL SERVICE INTERRUPTIONS WITH OWNER REPRESENTATIVES, MAINTENANCE STAFF, AND END -USERS. CONTRACTORSHALL PROVIDE SUFFICIENT ADVANCE NOTICE TO ALL AFFECTED PARTIES OF IMPENDING OUTAGE. D. SYSTEMS INDICATED BY DASHED LINE ARE TO BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE DESCRIBED BY PLAN NOTE(S). THIS INCLUDES THE REMOVAL OF EXISTING HANGERS, INSULATION, ASSOCIATED CONTROLS AND ACCESSORIES. ALL DUCTWORK AND PIPING TERMINATIONS NOT SHOWN AS BEING REUSED SHALL BE CAPPED. CONTRACTORSHALL PATCH INSULATION DAMAGED DURING DEMOLITION AND WHERE PIPING IS SHOWN TO BE CAPPED. E. WHEN EQUIPMENT REQUIRING ELECTRICAL POWER IS REMOVED, CONTRACTOR SHALL ALSO DEMOLISH EXISTING POWER WIRING AND CONDUIT. A LICENSED ELECTRICIAN SHALL BE RESPONSIBLE FOR REMOVING ALL POWER WIRING AND CONDUIT. F. WHERE REMAINING MECHANICAL,ELECTRICAL, PLUMBING, OR FIRE PROTECTION WORK PENETRATES EXISTING WALLS OR FLOORS, THE OPENING CREATED MUST BE REPAIRED TO MATCH THE EXISTING CONSTRUCTION AND FIRE RATING BY THE GENERAL CONSTRUCTION TRADE SKILLED IN THE WORK TO BE PERFORMED. G. IF THE WORK OF OTHER TRADES IS CURRENTLY SUPPORTED BY WORK TO BE DEMOLISHED, CONTRACTORSHALL FURNISH AND INSTALL NEW SUPPORTS. H. UNUSED HANGERS FOUND WITHIN THE PROJECT SCOPEAREA SHALL BE REMOVED. I. WHERE REQUIRED, PERFORM PREDEMOLITIONSYSTEM TESTING(AIRFLOA, TEMPERATURE, ETC) PRIOR TO BEGINNING ANY DEMOLITION. J. FOR PHASED SCOPE OF WORK, REFER TO ARCHITECTURAL PHASI NG PLANS AND OTHER PROJECT MANUAL REQUIREMENTS. CONTRACTOR IS TO VERIFY THE SPACES TO REMAIN ACTIVE UNDER THERMAL CONTROL AND EXHAUST SYSTEMS TO REMAIN ACTIVE TO SUPPORT THE PHASING. PROVIDE TEMPORARY SYSTEM MODI FICATI OS (BLANKOFFS, CAPS, TEMPORARY DUCT CONNECTIONS, TEMPORARY PIPE CONNECT ON$, ETC) AS REQUIRED TO SUPPORT THE PHASING. HVAC NEW GENERAL NOTES I A. NEW WORK SHOWN ON DRAWINGS IS CONCEPTUAL IN NATURE. CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL TRADES. CONTRACTOR SHALL PERFORM FINAL COORDINATION OF ALL TRADES AFTER CEILING REMOVAL ALLOWS FURTHER SITE INVESTIGATION ON EXISTING BUILDINGS. B. UNLESS NOTED OTHERWISE ON THE DRAWINGS, REFER TO SCHEDULES FOR DIFFUSER, GRILLE, TERMINAL BOX, AND OTHER TERMINAL EQUIPMENT RUNOUT SIZES. C. WHERE EQUIPMENT REQUIRING ACCESS MUST BE INSTALLED ABOVE GYPSUM CEILING, CONTRACTOR SHALL COORDINATE ADEQUATE ACCESS WITH ALL TRADES AND PROVIDE THE REQUIRED ACCESS PANELS. D. AIRFLOW OFFSETS NOTED ARE INTENDED TO PROVIDE INITIAL VALUES FOR THE TEST AND BALANCE CONTRACTOR. FINAL AIRFLOW OFFSETS ARE TO BE DETERMINED DURING FUNCTIONAL TESTING AND FINAL VOLUMETRIC FLOW RATES SHALL BE DOCUMENTED ON AS -BUILT DRAWINGS. E. COORDINATE WITH ALL TRADES TO PROVIDE THE REQUIRED EQUIPMENT ACCESS. REFER TO SPECIFICATION "COMMON WORK RESULTS FOR HVAC' FOR ADDITIONAL INFORMATION. F. FOR PHASED SCOPE OF WORK, REFER TO ARCHITECTURAL PHASING PLANS AND OTHER PROJECT MANUAL REQUIREMENTS. PROVIDE TEMPORARY SYSTEM MODIFICATIONS AS REQUIRED TO SUPPORT THE PHPSI NG. G. NO PIPING SHALL PASS THROUGH OR BE LOCATED WITHIN ELECTRICAL ROOMS, ELECTRICAL CLOSETS, ELEVATOR MACHINE ROOMS, STAIRWELLS, OR ELEVATOR HOISTWAYS. HVAC-RELATED CODE AND STANDARD INFORMATION MECHANICAL CODE. 2014INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE W TH 675IAD 18-16 IMPLEMENTING AMENDMENTS). FUEL GAS CODE'. 2D14 INDIANA FUEL GAS CODE (2D12 INTERNATIONAL FUEL GAS CODE WITH 6751AD 253 IMPLEMENTING AMENDMENTS). ENERGY CODE'. 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-20W WITH 6751AD 19-4 IMPLEMENTING AMENDMENTS). MECHANICAL SYSTEM DESIGN CRITERIA'. CLIMATEZONE5A. ECONOMIZER DESCRIPTION', SEE TEMPERATURE CONTROL SHEETS. EQUIPMENT AND SYSTEM CONTROL DESCRIPTION. SEE TEMPERATURE CONTROL SHEETS. FAN MOTOR HORSEPOWER(hp) AND CONTROLS. SEE EQUIPMENT SCHEDULE SHEETS FOR MOTOR HORSEPOWER SIZES. SEE TEMPERATURE CONTROL SHEETS FOR MOTOR CONTROL. DUCT SEALING AND DUCT AND PIPE INSULATION INFORMATION', SEE HVAC SPECIFICATIONS 230700 AND 233113. SEE ARCHITECTURAL DRAWINGS FOR THE REQUIRED INFORMATION REGARDING', INSULATION MATERIALS AND THEIR R-VALUE$, FENESTRATION U FACTORS AND $HGC, AREA -WEIGHTED U FACTORS AND SHGC CALCULATIONS, AIR SEALING DETAILS, AND BUILDING THERMAL ENVELOPE DETAILS. NFPA992012'. COMPLIES WITH CHAPTER 9. BSA LifeStructures 9365 Counselors Row Suite 300 Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www. bsal'Ifestructures.00m VISIONFIRST Indiana Lions Eye Bank OFFICE AND LAB RENOVATION CLIENT PROJECT NO. - 21160001 CONSTRUCTION DOCUMENTS MARK I DATE I DESCRIPTION HVAC SYMBOLS, ABBREVIATIONS AND GENERALNOTES RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel ' NPA IDI DATE: 02/20/19 DATE BSALS PROJECT NO. DEC. 19, 2018 21160001 H001