Loading...
HomeMy WebLinkAboutH 500F. INTERIOR DESIGN AREA FOR LAB SPACE OFFICE SPACE AIR HANDLING UNIT SYSTEM INDEX SCHEDULE HVAC DESIGN DATA OUTSDIE DESIGN 92 DEG. F DB SUMMER TEMPERATURES 79 DEG. F WB SUMMER 2 DEG. F DB WINTER DESIGN ALTITUDE: 715 FT. INDIANAPOLIS, INDIANA 70 40-50 sfi-70 40-50 sfi-7o 40-w sfi-70 40-50 74 NIA 70 NIA 74 NIA 70 NIA 2. EXTERNAL STATIC PRESSURE OF UNIT TO BE TING MIN, ELECTRICAL DATA FINAL OPERATING DESIGN REFERENCE INLET SOUND POWER LEVELS OUTLET SOUND POWER LEVELS AREA TYPE OF AIR SUPPLY EXHAUST RETURN PRE -HEAT COOLING EMERGENCY PRE -FILTER FILTER MINIMUM WEIGHT 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 TAG LOCATION SERVED SYSTEM BLENDER FAN NO. FAN 40. FAN NO. COIL NO. COIL NO. FLA MCA MOP VOLT PHASE CYCLE POWER NO. NO. O.A. (LBS.) MANUFACTURER MODEL HZ HZ HZ HZ HZ HZ HZ HZ HZ HZ HZ HZ HZ HZ HZ HZ NOTES AHU-1 OUTSDE LAB CV NONE $F-1. $F-2 EF-7 NONE HGRC CC 66.7 71 30 460 3 6o YES PF FF WID 6500 45EASONS SA01513SFC25019z-XX)OOF06HG 84 1 84 1 86 1 92 1 84 1 84 1 80 75 87 90 1 90 1 94 1 91 1 90 1 85 1 80 1.2 COIL SCHEDULE 1. PROVIDED BY AHU MANUFACTURER. 2. HOTGAS REHEAT COIL OF CC. SHALL NOT EXCEED 50%OF COOLING COIL CAPACITY PER ASHRAE 90.1 .2007. TAG SYSTEM CFM CAPACITY (MBH) MAX. FACE VELOCITY (FPM) MIN. FACE VELOCITY (FPM) # OF ROWS # OF COILS MAX. FINS PER INCH ENTERING AIR TEMPERATURE LEAVING AIR TEMPERATURE REFRIGERATIO N FLUID NOTES TOTAL SENSIBLE l0 (°F) WB (°F) l0 (°F) WB (°F) REFRIGERANT TYPE CC AHU-1 6,000 230 159 500 350 6 2 10 73.3 B 49.9 49.5 410A 1 HGRC AJI 6,000 117 117 750 350 2 2 9 49.9 49.5 70.9 58.1 410A 7,2 FAN SCHEDULE 1) ECM WITH 0-10VDC INPUT 4 PROVIDED BY AHU MANUFACTURER. SOUND POWER (MAX. DB) PER OCTAVE BAND (NOTE: N INLET SOUND FOR RETURN AND EXHAUST FANS; a, z y WHEEL MOTOR OUTLET SOUND FOR SUPPLY FANS) LU g DESIGN REFERENCE F u3i z LU o O N 0 ID z ID 0 F O Z O U 0 K O ¢ 0 t7 M LU K Z O O G j VSC U) K 0 U) ly K 7 O F K a 2 � s SPEED AT U) 0 0 y~j Z U. U. 4 ~ T.S.P. FAN MIN. DIA. FAN MAX. DESIGN EMERGENCY 63 125 250 500 1000 2000 4000 8000 V lu 0 F Q J w WEIGHT TAG LOCATION AREA SERVED CFM (IN. ill FAN TYPE CLASS ARRANGEMENT TYPE (IN.) RPM FAN SONES BHP FLOW HP RPM VOLTS PHASE CYCLE POWER Hz Hz Hz Hz Hz Hz Hz Hz Q O O O 0 i K 7 Q (LBS) MANUFACTURER MODEL NOTES UP BI 11' m M M 5;K ran 3 EF-0 ROOF LAB EXHAUST 800 0.8 UPBLASTPOWER 1 1626 10 0.2 1626 114 1725 115 1 60 YES 74 72 74 69 64 63 58 51 No No Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes 40 GREENHECK CUE4099VG 1 VENTILATOR 1n5 9 0.12 1n5 1110 1725 115 1 60 NO 79 77 71 65 61 57 54 47 No No Yes No Ves Ves Ves Yes Yes Yes Yes Yes Yes Yes No Yes 33 GREENHECK CUEJI9DVG 1 EF.E ROOF CAFE 500 0.8 UPBLAST POWER I UP BI 11' VENTILATOR SF1 AHU-1 LAB SUPPLY 4,500 6.5 PLENUM II 4 PF 16' 2976 SEE OCTAVE BAND 9.6 2676 10 3500 460 3 60 YES 87 90 90 54 91 90 85 80 ND No Yes NO No Yes No No Yes No Yes No No No No No 300 GREENHECK APH PLENUM SWSI 2 SF2 AHU-1 LAB SUPPLY 4.500 6.5 PLENUM II 4 PF i6' 2916 SEE OCTAVE HAND 9.6 2676 10 3500 460 3 60 VES 87 90 90 94 91 90 85 80 No No Ves No No Ves No No Ves No Ves No No No No No 300 GREENHECK APH PLENUM SWSI 2 HUMIDIFIER SCHEDULE 1. PROVIDE WITH CONTROLLER INTERFACE CAPABLE OF CONNECTING TO ETHERNET ACCESS. EC TO PROVIDE DISCONNECT TO 2. PROVIDE WITH STEAM CONTROL VALVE AND CONDENSATE CONDENSER. SEE DETAIL 5ON SHEET H700. HUMIDIFIER. TAG LOCATION 100°/w 0 A ECONOMIZER DESIGN CFM HEATING DESIGN CONDITIONS DESIRED ROOM CONDITIONS CAPACITY (#/HR.) DUCT SIZE MANIFOLD MAX. ABSORPTION DISTANCE ON.) ELECTRICAL DATA DESIGN REFERENCE NOTES ENTERING AIR LEAVING AIR DB (°F) RH (°/w) WIDTH (IN.) HEIGHT (IN.) NUMBER LENGTH (IN.) HEIGHT (IN.) KW VOLT PHASE FLA EMERGENCY POWER MANUFACTURER MODEL DB (°F) WB (°F) DB (°F) RH (%) H1 WATER ROOM 61D0 54 47 74 1 50 70 50 36 76' 1 14' 1 70' 2' 20' 12.0 1 2W 3 46.7 I YES DRISTEEM LOW MAINTENANCE HUMIDIFIER 1,2 ROOFTOP MINISPLIT SYSTEM 1. MINIMUM EER OF 12.2. PROVIDE WITH COMPATIBLE THERMOSTAT WITH WIRELESS CAPABILITIES (PREFERENCE TO SENSI PRODUCT) 2, UNIT TO MODULATE TO KEEP ELECTRICAL ROOM AT 80 DEG(ADJ) INDOOR UNIT TO BE POWERED BY OUTDOOR UNIT. TAG AREA SERVED DESIGN REFERENCE COOLING CAPACITY PHASE VOLTAGE NOTES MANUFAC TURER MODEL RTU-17 EV-1 ELECTRICAL ROOM MITSUBISHI PUY-A24NHA7 24000 Btu 1 208V 1 1.2 TAG SYSTEM CFM I(IN.) COIL SIZE WIDTH HEIGHT (IN.) EAT (°F) DUCT -MOUNTED ELECTRIC COIL SCHEDULE MAX, ELECTRICAL HEAT LAT A.P.D. (°F) (IN. W.G.) kW VOLT PHASE SCR ELECTRICAL DATA EMERGENCY POWER DESIGN REFERENCE MANUFACTURER MODEL NOTES DC-1 AHU4 3,000 32.6 W Or 65 75 0.5 9.4 1 208 1 3 YES YES PRICE EC DC-2 AHU4 285 Si LP LP 65 75 0.6 0.9 1 208 1 3 YES YES PRICE EC DC-3 AHU4 360 S9 iP iP 65 75 0.6 1.1 208 3 YES YES PRICE EC DU AHU4 2,136 23.2 20H 12H 65 75 0.6 6.7 208 3 YES YES PRICE EC DC5 RTU49 37D 12.0 12" 12" 55 85 0.5 3.5 120 1 YES NO PRICE EC DC6 RTU-09 3ID II.0 12" 1F 55 85 0.5 3.5 12D 1 YES NO PRICE EC DC-1RTU-1 555 18.1 Ir 12" 55 85 0.5 5.1 120 1 1 YES NO PRICE EC AIR FILTER SCHEDULE FACE MAX. A.P.D. CARTRIDGES EFFICIENCY VELOCITY HOUSING ARI TAG SYSTEM CFM MERV (FPM) INITIAL FINAL FILTERTYPE TYPE QUANTITY SIZE ON.) 4 a NOTES 7 1 DIFFUSER/ GRILLE SCHEDULE 1)(4)WSLOTS 3) REFER TO DETAIL 41HM1 5) PROVIDE WITH INTEGRAL DAMPER THAT MAY BE ADJUSTED FROM FACE OF GRILLE. 2) INTEGRAL BUTTERFLY DAMPER 4) REFERENCE DETAIL I ON SHEET H701. 6) ALL GRILLES AND DI FFUSERS TO BE SELECTED FOR APPROPRIATE MOUNTING METHOD: SURFACE MOUNT, LAY -IN, ETC. Type Mark NECK SIZE FACE SIZE MATERIAL FINISH CFM RANGE MAX NC MAX THROW (FT) MAX TOTAL ADP (IN WG) MANUFACTURER MODEL NOTES ECG1 24X24 24)(24 ALUMINIUM B12. WHITE 0.750 28 PRICE 80SR ECG2 6 12X24 ALUMINIUM 812-WHITE 0-20U 28 PRICE 80SR EGGS 48)(6 48X6 ALUMINIUM B12-WHITE 0-1000 32 PRICE 85 ECG4 36X6 36X6 ALUMINIUM B12-WHITE 0-800 32 PRICE 85 3A ECRG 24)(24 24)(24 ALUMINIUM B12. WHITE 0.1500 32 PRICE 85 EPD1 8 24X24 STEEL B12-WHITE D135 20 0.05 PRICE SPD EPD2 10 24)(24 STEEL B12-WHITE 136380 20 0.09 PRICE SPD LBG1 10 48X3 STEEL B12. WHITE 0.300 25 28 0.08 PRICE So$ a SDB PLENUM 1 LF1 10 24X24 ALUMINIUM 812. WHITE 0-MID 12 0.10 PRICE LED 2 IF2 12 24X48 ALUMINIUM B12-WHITE 200-600 26 6 0.10 PRICE LED 2 RG2 1SX12 1SX12 STEEL B12-WHITE 236-350 25 PRICE BDDAL 5 RG3 24X12 24X12 STEEL B12-WHITE 236.350 25 PRICE MDAL 5 RPD1 8 24)(24 STEEL all 2-WHITE D135 20 0.05 PRICE SPD RPD2 10 24)(24 STEEL B12-WHITE 136380 20 0.09 PRICE SPO RPD3 12 24)(24 STEEL B12-WHITE 381.550 22 0.13 PRICE SPD RPD4 14 24)24 STEEL B12-WHITE 55D750 22 0.15 PRICE SPD SPD1 8 24)(24 STEEL 812-WHITE 0-135 15 6 0.05 PRICE SPD SPD2 70 24)24 STEEL 812-WHITE 135-380 20 10 0.09 PRICE SPD BPD3 12 24X24 STEEL 312-WHITE 1 381-5W 1 22 1 12 1 0.13 PRICE SPD BSA BSA LifeStructures 9365 Counselors Row Suite 300 Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www. tIsal'Ifestructures.00m VISIONFIRST Indiana Lions Eye Bank OFFICE AND LAB RENOVATION CLIENT PROJECT NO. - 21160001 CONSTRUCTION DOCUMENTS MARK I DATE I DESCRIPTION HVAC SCHEDULES RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Racal Codes City of Carmel ' VPAGIDI DATE: 02/20/19 DATE DEC. 19, 2018 BSALS PROJECT NO. 21160001 H500