HomeMy WebLinkAboutH 700F. EF-1 HORIZONTAL RUN N BETWEEN BAR JOISTS l 1 fr(r/ 14JX14 RETLRN DDcr Zp CAPPED EXHAUST FAN 1 SECTION iI SAFETY RELIEF VALVE FROM EQUIPMENT SERVED SEE PLANS FOR LINE SIZE. 91 DRAIN FROM VALVE BODY PLAN NOTES: I. LARGER SIZES MAY BE FLANGED VENT PIPE UP THRU ROOF y DRIP PAN ELBOW I—^ "Y"FI—TTING "'�+"'�L RUN 314"DRAIN LINE TO NEAREST UNION (TYPICAL) FLOOR DRAIN SAFETY RELIEF VALVE WITH DRIP PAN ELBOW PIPING DETAIL NO SCALE RELEASED FDR CDN Subject to compliance with of State and local SUPPLYAIR SUPPL LAWN AREAS CONCRETE SUPPORT PAD PAVEMENTAREAS 6' CONCRETE SLAB WIM4 (tg IT EW 1 p4 CENT, N (EPDXY COATED) — (ALL SIDES) FINISHED PROVIDE ISOLATION JOINT GRADE GRADE \ WHEN SUPPORT PAD ABUTS CONCRETEEPAVE PAVEMENT III,I UII II "' II II II 4" COMPACTED, DRAINAGE FILL — • f • �V PLAN NOTES 1. CONTRACTOR TO COORDINATE SIZE,LOCATION, FINISHED GRACE, CURB PENETRATIONS, AND POSITIVE DRAINAGE REQUIREMENTS WITH EQUIPMENT PROVIDER. 2, PROVIDE STEEL TROWEL FINISH ON EXPOSED SURFACES AND SLOPE TOP SURFACE TO PROVIDE POSITIVE DRAINAGE. H1 EQUIPMENT SUPPORT DETAIL NOSCALE 1-12- COPPER TUBE OR SIZE PER MANUFACTURERS RECOMMENDATIONS COVER PLATE AND DUCTWORKOR GASKET (TYPICAL) AHU PLENUM ELECTRIC I 11 r HUMIDIFIER 6" MIN. (TYP), -� U j ` MANIFOLD SUPPORT lku1 u/ (TYPICAL) 12' COPPER PLAN NOTES I, LOCATE DISPERSION TUBE PER MANUFACTURER'S RECOMMENDATIONS 2. CONDENSATE LINE TO GRAVITY DRAIN WITH NO LIFTING. COORDINATE PIPE ROUTING WITH ALL TRADES. INSTALL THIS PIPE PRIOR TO ANY OTHER INSTALLATIONS OF PIPE, CONDUIT, DUCT OR CEILING. SEE PLANS FOR CONDENSATE LINE ROUTED TO CONDENSATE COOLER LIKE DRI-STEEM DRANE-KOOLER. 3. SEE STEAM TRAP DETAIL ELECTRIC HUMIDIFIER PIPING DETAIL NO SCALE UWM77m ACCESS ACCESS I z n ACCESS DOOR DOOR ADOORS DOOR w L__J i HOTGAS DXCOIL REHEAT COIL ® CONTROL PANEL SUPPLYAIR yQO 0 — LL VU o � x RETURNAIR ® �u W w ® Ja z � STRUCTIDN all regulations 99 Codes City of Cannel �VTI�\Dw�1DML DATE: 02/20/19 4 AHU 1 PLAN NOTES I. MOUNT WALL EXHAUST GRILLE WITH BOTTOM 12'A.F.F. �1 LOW EXHAUST/RETURN DETAIL NO SCALE STRAINER CHECKVALVE GATE VALVE Z GATE VALVE CAPPED NIP PLE WITH CNPPLE PLAN NOTES: 1. INSTALL 112' BLOW OFF VALVE ON STRAINER WITH NIPPLE AND CAP. 8 STEAM TRAP DETAIL NO BE ROUND BRANCH DUCT TO MAIN PLENUM TO BE EXTERNALLY INSULATED ,� (SEE SCHEDULE FOR SIZE) —'`J SHEETMETAL PLENUM SHALL BE SUPPORTED INDEPENDENTLY FROM STRUCTURE (NOT SUPPORTED BY CEILING) INSIDEOF PLENUM O INSULATED FLEXIBLE" SHALL BE PAINTED FLAT BLACK DUCTWORK \ DUCTWORKIDIFFUSER SHALL BE %/\\ PLENUM BOXHEIGHT= SUPPORTED INDEPENDENTLY FROM ` > ROUND DUCT DIA+4- STRUCTURE (NOT SUPPORTED BY CEILIN NIDUCTWORKIDIFFUSER SHALL BE SUPPORTED OUTDOOR SQUARE DIFFUSER/GRILLE —" INDEPENDENTLY FROM STRUCTURE AIR (NOT SUPPORTED BY CEILING) INSIDE SQUARE DIFFUSER OBSTRUCTED INSTALLATION OF PLENUM TO BE PAINTED FLAT BLACK. ROUND BRANCH DUCT TO MAIN _ (SEE SCHEDULE FOR SIZE) EXTERNALLY INSULATE PLENUM. INTERNAL INSULATION ISNOTALLOWED. O1 INSULATED FLEXIBLE DUCTWORK / PLENUM BOX ROUND BRANCH C2)-- %j HEIGHT =ROUND AHU 1 SITS ON CONCRETE PAD. DUCT TO MAIN %// DUCT DIAMETER «4' SEE DETAIL (SEESCHEOJLE INSULATED / // ADJUSTAIR IANCHEQUIPMENT ANCHORED AHU TANCHOREO TO PAC. FOR SIZE) FLEXIBLE �.+ �% PER SCHEDULE AND PLANS EDULE AND PLANS DUCTWORK `` SLOT DIFFUSER (THREE SLOT SHOWN) SLOT DIFFUSER INSTALLATION DUCT RADIUS TO DIFFUSER MIN 2 DUCTWORKIDIFFUSER SHALL BE DUCT DIAMETERS SUPPORTED INDEPENDENTLY � FROM STRUCTURE(NOT lam / SUPPORTED BY CEILING) MI'MIN. OUTDOOR AIR SQUARE TO ROUND TRANSITION, EXTERNALLY INSULATE BACK OF DIFFUSER `— SQUARE DIFFUSER PLAN NOTES SQUARE DIFFUSER INSTALLATION 1. AMINIMUM OF FIVE(5) FEET LENGTH OF FLEXIBLE DUCT SHALL BE PROVIDED TO EACH DIFFUSER. DUCTWORKSHALL CONTAIN 180.OF BENDING. FLEXIBLE DUCTWORK LENGTH SHALL NOT EXCEED EIGHT(8) FEET EXCEPT WHERE SPECIFICALLY NOTED. FLEXOUCTSHALLNOT CONTACT CEILING AND SHALL BE PROPERLY SUPPORTED BOAS TO HAVE NO KINKS. 2. TIE-WRAPCONNECT FLEX DUCT HELICAL COIL TO ROUND METAL DIFFUSER NECKAND TO ROUND METAL DUCTWORKAT OTHER END OF FLEX DUCT. PULL FLEX DUCT VAPOR BARRIER OVER LOWER TIE -WRAP AND INSTALL SECOND TIE -WRAP OVER THE VAPOR BARRIER. INSULATEMETAL DUCT OR DIFFUSER OVER TOP OF SECOND TIE -WRAP AND INSTALL INSULATOR'S TAPE ON EDGES. 3. PROVIDE A MINIMUM OF NB'OF STRAIGHT, VERTICALLY ORIENTED, FLEXIBLE DUCT AT THE DIFFUSER NECK. IF UNABLE TO PROVIDE STRAIGHT DUCT RUN THEN PROVIDE OBSTRUCTED INSTALLATION PLENUM IN ACCORDANCE WITH THIS DETAIL, DIFFUSER DETAIL NO SCALE MOTOR DISCONNECT SWITCH BIRDSCREEN / } FOAM RUBBER GASKET � APPLIED TO UNDERSIDE OF FAN CURB CAP FAN CURB CAP SEE ROOF CURB DETAIL ROOF INSULATION SECURE FAN TO CURB WITH SHEET METAL SCREWS IT O.C. ALL AROUND DOME — DISCHARGE APRON CURB O — ROOF INSULATION ROOF DECK ROOFING TO EMEND UP AND OVER TOP OF CURB L CURB FASTENING FLANGE SECURE CURB TO ROOF J ROOFDECK USING FASTENERS AT IT O.C. I SEAL OPENING AIRTIGHT BEFORE APPLYING ROOFING I ROOF OPENING INTERNALLY LINE DUCTWORK I WITH 1' FIBERGLASS MINIMUM 18 GAUGE DUCT INSULATION (MIN R-3 WIN OR _ J HVAC INSULATION SPEC, WHICHEVER IS HIGHER) DAMPER O PLAN NOTES 1. CURB AND EXHAUST FAN SHALL BE FROM SAME MANUFACTURER. 2, DAMPER SHALL BE TWO WHEEL DIAMETERS FROM INLET CONE, ALL DUCT CONNECTIONS SHALL BE BELOW BACKDRAFT DAMPER. 3. CHECK SCHEDULE FOR UPBLASTIIDOWNBLAST FAN. i1 POWER ROOF VENTILATOR DETAIL NO SCALE FRAMED WALL OPENI NO OF SIZE TO PASS DUCT FRAMED WALL OPEN ING OF SIZE TO ANDLEAVE ROOM FOR SEALANT TO MEET UL- PASS DUCT AND LEAVE ROOM FOR DUCT DUCT 91810@NR1C1.191 C EACH SIDE OF DUCT ON EACH SIDE OF WALL WITH 1 NONCOMBUSTIBLE S SEALANT. FINISHED WALL FINISHED SURFACE OF WALL UNINSULATEO DUCT THROUGHINTERIOR� RATED SURFACE NON -RATED WALLS OR SMOKE-RESISTAN ASSEMBLY UNINSULATE D DUCT THROUGHO CORRIDORWALLS INTERIOR FIRE RATED WALLS FRAMED WALL OPENING OF OtAND AMED WALL OPENING OF SIZE E TO LEAVE ROOM FOR DUCT PASS DUCT AND INSULATION, AND SEALANT. ULATION LEAVE ROOM FOR ALANT DUCT MEET UL-LISTINOUCT DUCT INSULATION DUCT INSULATION TO BE TO BE CONTINUOUS CONTINUOUS THROUGH WALL. THROUGH WALL. 1 FILL ANNULAR GAPS _— EACH FINISHED 3O FINISHED SIDE OF DUCT ON EACH WALL WALL SIDE OF WALL WITH IL SURFACE OF NONCOMBUSTIBLE RATED SURFACE INSULATED DUCT THROUGH INTERIOR'S OR SEALANT. ASSEMBLY FIRE RESISTANCE RATED WALLS INSULATE WALLS OR SMOHINTER TA NON -RATED WALLS OR SMOKE -RESISTANT PLAN NOTES CORRIDOR WALLS 1. INSTALL FIRESTOP SYSTEM AS SPECIFIED IN DIVISION 7. INSTALL RETAINING ANGLES AS REQUIRED BY SYSTEM LISTING. 2. INCLUDES FIRE BARRIERS, SMOKE BARRIERS, AND FIRE PARTITIONS AS DEFINED IN THE LOCAL APPLICABLE CODES AND ON THE PLANS. 3. LOCATE FIRESTOP LABEL ON EACH SIDE OF PENETRATION SO THAT IT IS VISIBLE FROM AN ACCESSIBLE LOCATION ABOVE CEILING. r <Z DUCT PENETRATION DETAILS NOSCALE DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN CLEAN OUT PITCH DOWN TOWARD DRAIN CLEAN OUT INSULATEENTIRE CRAW ASSEMBLY WITH ELASTOMERIG r GROUND UNIT A B NI IN) AHU I DX COIL 2 85 ENTIRE GRAIN PAN CONDENSATE DRAIN SHALL BE C MINIMUM. 1 INCREASE GRAVEL DEPTH IF NECESSARY TO MEET HEIGHT REQUIREMENTS. CONDENSATE DRAIN TRAP DETAIL NO SCALE BSA BSA LifeStructures 9365 Counselors Row Suite 300 Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www. bsafrfestructures.00m VISIONFIRST Indiana Lions Eye Bank OFFICE AND LAB RENOVATION CLIENT PROJECT NO. - 21160001 CONSTRUCTION DOCUMENTS MARK DATE DESCRIPTION I 01/142019 ADDENDUM I T` No. ' PE10302020 STATE OF HVAC DETAILS DATE BSALS PROJECT NO. DEC. 19, 2018 21160001 H 700