Loading...
HomeMy WebLinkAboutP 001VALVE AND FITTING SYMBOLS PLAN VIEW DETAIL VIEW PIPING FLEXIBLE CONNECTION -T7111I -0 PIPE TURNED UP (UNLESS NOTED OTHERWISE) 0 PIPE TURNED DOWN �> PPE OUT TOP ! PIPE OUT BOTTOM THREADED NIPPLE WICAP —� PPE WITH BLIND FLANGE I CONCENTRIC REDUCER J ECCENTRIC REDUCER ISOLATION VALVE CHECK VALVE UNION GATE VALVE BALL VALVE M GLOBE VALVE BUTTERFLY VALVE $ TEMPERATURE CONTROL-2-WAY MODULATING VALVE TEMPERATURE CONTROL - 2-WAY, 2�POSITION ISOLATION VALVE TEMPERATURE CONTROL-3-WAY MODULATING VALVE Is NO 16 TEMPERATURE CONTROL - 3-WAY, 2-POSITION ISOLATION VALVE Bed ! 4NO -4 cr CALIBRATED BALANCE VALVE SAFETY RELIEF VALVE 031 STRAINER �J— FLOW METER ® S ® FLOOR DRAIN By PC $ AUTOMATIC FLOW CONTROL VALVE FLOW MEASURING DEVICE MANUAL AI R RELIEF VENT AUTOMATIC AIR RELIEF VENT J LUBRICATED PLUG VALVE PRESSURE REDUCING VALVE(STEAM, GAS, COMPRESSED AIR) ANGLEVALVE � REFRIGERANT HOT GAS BY-PASS VALVE SHUT-OFF COCK(HYDRONICS) SOLENOIDVALVE REFRIGERANT EXPANSION VALVE WATER PRESSURE REDUCINGIREGULATNG VALVE O —r-- STEAMTRAP DIELECTRIC FITTING BETWEEN STEEL AND COPPER —1H KID STRAINER (STEAM) PRESSURE AND TEMPERATURE PLUG REFRIGERANT SIGHT GLASS THERMOMETER PT.VTT.(P=PRESS V=VAC T=TEMP)GAUGE SENSOR Q-TEMP H-HUMIDITY) 8 FS FLOW SWITCH NCO CLEAN OUT INDICATED EXPANSION LOOP (COLD SPRUNG) ANCHOR GUIDE REFRIGERANT SHUT-OFF VALVE —311111 EXPANSION JOINT TWO I DIFFERENTIAL SWITCH 8wp 8 dNCtl REDUCED PRESSURE BACKFLOWPREVENTER rTn DOUBLE CHECK VALVE ASSEMBLY [� CN FIRE DEPARTMENT CONNECTION (] b3 FIRE PROTECTION CONTROL VALVE FLOOR PLAN SYMBOLS SECTION WITH TOP NUMBER INDICATING 1 TYP SECTION DESIGNATION AND BOTTOM NUMBER A701 INDICATING DRAWING THAT SECTION IS CUT ON OR DRAWING THAT SECTION IS DRAWN ON DETAIL WITH TOP NU MEER I NDICATING DE TAIL DESIGNATION 1 TYP AND BOTTOM NUMBER INDICATING DRAWING THAT DETAIL QA101 IS REFERENCED ON OR DRAWING THAT DETAIL IS DRAWN ON A. GENERAL NOTE 1. PLAN NOTE LIST O PLAN NOTE OT THERMOSTAT O HUMIDISTAT PM PRESSURE MONITOR (FLOOR PLAN) ® Co2 MONITOR (FLOOR PLAN) 51, CONNECTION OF NEW WORK TO EXISTING GENERAL HVAC AND PLUMBING ABBREVIATIONS ABBREV DESCRIPTION ABBREV DESCRIPTION ABBREV DESCRIPTION AIE ARCHITECT AND ENGINEER GPM GALLONS PER MINUTE PC PRESSURE DROP AD ACCESSDOOR GV GAS NATURAL VENT POC POINT OF CONNECTION ADJ ADJUSTABLE OR ADJACENT GW GLASSWAREWASHER PPH POUNDS PER HOUR AFF ABOVE FINISHED FLOOR PPM PARTS PER MILLION APPROX APPROXIMATE H HEIGHT PREFAB PREFABRICATED ARCH ARCHITECT HD HEAD PRES PRESSURE ATM ATMOSPHERE HGT HEIGHT PRV PRESSURE REDUCING VALVE HOA HAND -OFF -AUTOMATIC PSI POUNDS PER SQUARE INCH BHP BRAKE HORSEPOWER HORZ HORIZONTAL PSIG POUNDS PER SQUARE INCH GAUGE BLDG BUILDING HOSP HOSPITAL PVC POLYVINYL CHLORIDE GOT BOTTOM HP HORSEPOWER BTU BRITISH THERMAL UNIT AR HOUR REC RECEIVER BTUH BTU PER HOUR HZ HERTZ RECIRC RECIRCULATING REF REFRIGERATOR CAP CAPACITY ID INSIDE DIAMETER OR DIMENSION RLA RUNNING LOAD AMPS CENTRIF CENTRIFUGAL IN INCHES RM ROOM CFH CUBIC FEET PER HOUR INCL INCLUDE RPM REVOLUTIONS PER MINUTE CFM CUBIC FEET PER MINUTE INSUL INSULATED CFOI CONTRACTOR FURNISHEDIOWNER INSTALLED INT INTERIOR SA SUPPLY AIR OR SOUND ATTENUATOR CI CASTIRON INV INVERT SCFM STANDARD CUBIC FEET PER MINUTE CO CLEANOUT I.P.S. INTERNATIONAL PIPE SIZING SCH SCHEDULE COL COLUMN SEC SECTION COMP COMPRESSOR JT JOINT SENS SENSIBLE CONIC CONCRETE SF SQUAREFOOT CONN CONNECTION KAIC SHORT CIRCUIT RATING SHT SHEET CONST CONSTRUCTION KEC KITCHEN EQUIPMENT CONTRACTOR SPEC SPECIFICATIONS CSP CEILING SERVICE PANEL KW KILOWATTS SO SQUARE SOFT SQUARE FEET DEG DEGREE L LENGTH SRV SAFETY RELIEF VALVE DEPT DEPARTMENT LBS ORB POUNDS SS STAINLESS STEEL CIA DIAMETER LF LINEAR FOOT STD STANDARD DISC DISCONNECT LFT LEAVING FLUID TEMPERATURE STIR STARTER OR STRUCTURE DISCH DISCHARGE LOC LOCATION STRUC STRUCTURAL DN DOWN LVG LEAVING SW SWITCH DWG DRAWING LWT LEAVING WATER TEMPERATURE SYS SYSTEM EC ELECTRICAL CONTRACTOR MAX MAXIMUM TCC TEMPERATURE CONTROL CONTRACTOR ECC ENVIRONMENTAL CONTROL CONTRACTOR MBH 1000 BTUIHR TDH TOTAL DYNAMIC HEAD EER ENERGY EFFICIENCY RATING MC MECHANICAL CONTRACTOR TEMP TEMPERATURE ELEC ELECTRIC MCA MINIMUM CIRCUIT AMPACITY TILL TEMPERATURE LOW LIMIT ELEV ELEVATION MCC MOTOR CONTROL CENTER TMBH TOTAL MBH EVER EMERGENCY MFR MANUFACTURER TSP TOTAL STATIC PRESSURE ENCL ENCLOSURE MIN MINIMUM TYP TYPICAL ENTR ENTERING MISC MISCELLANEOUS EQUIP EQUIPMENT MOCP MAXIMUM OVERCURRENT PROTECTION LINO UNLESS NOTED OTHERWISE ET EXPANSION TANK MID MOUNTED UVL ULTRA VIOLET LIGHT FIR EXISTING TO REMAIN (DIFFUSERIGRILLE) EWT ENTERING WATER TEMPERATURE N NORTH VB VACUUM BREAKER EX OR EXIST EXISTING NA NOTAPPLICABLE VEL VELOCITY EXT EXTERIOR NC NORMALLY CLOSED OR NOISE CRITERIA VFC VARIABLE FREQUENCY CONTROLLER NIC NOT IN CONTRACT VSC VARIABLE SPEED CONTROLLER F DEGREES FAHRENHEIT NO NORMALLY OPEN OR NUMBER VTR VENT THROUGH ROOF FC FLEXIBLE CONNECTION NOM NOMINAL FH FUME HOOD NTS NOT TO SCALE W WATTS OR WI DTH FIN FINISH WI WITH FLA FULL LOAD AMPS OC ON CENTER WIO WITHOUT FLR FLOOR OD OUTSIDE DIAMETER WC WATER COLUMN FPC FIRE PROTECTION CONTRACTOR OFCI OWNER FURNISHEDICONTRACTOR INSTALLED WFMD WATER FLOW MEASURING DEVICE FT FEET OFOI OWNER FURNISHEDIOWNER INSTALLED DUNG WATER GAUGE OPER OPERATOR WET WEIGHT G GAS,NATRUAL OPNG OPENING AM WATER METER GA GAUGE ORD ORIGINAL WP WEATHERPROOF GAL GALLON WPD WATER PRESSURE DROP GALV GALVANIZED P PUMP, PNEUMATIC OR PRESSURE WTR WATER GC GENERAL CONTRACTOR PC PLUMBING CONTRACTOR GH GRAVITY HOOD PLUMBING ABBREVIATIONS ABBREV. DESCRIPTION ABBREV. DESCRIPTION ABBREV. DESCRIPTION Al AIR INTAKE FOS FUEL OIL SUPPLY PIV POST INDICATOR VALVE AR AIR RECIEVER FOST FUEL OIL STORAGE TANK PPM PARTS PER MILLION AV ACID VENT FOV FUEL OIL VENT PT PLASTER TRAP AN ACID WASTE PW PURE WATER GI GREASE INTERCEPTOR PAID PURE WATER PUMP BP BRINE PUMP GFH GALLONS PER HOUR PAR PURE WATER RETURN BST BULK SALT STORAGE GT GREASETRAP PWS PURE WATER SUPPLY PAST PURE WATER STORAGE TANK CA COMPRESSED AIR NO HUB OUTLET CO2 CARBON DIOXIDE HWC HOT WATER RECIRC RB REFRIGERATOR BOX HWCP HOT WATER CIRCULATING PUMP RD ROOF DRAIN DCV OR DCVA DOUBLE CHECK VALVE ASSEMBLY ROM REVERSE OSMOSIS MACHINE DCW DOMESTIC COLD WATER IA INSTRUMENTAIR ROP REVERSE OSMOSIS PUMP DCWBP DOMESTIC COLD WATER BOOSTER PUMP IAC INSTRUMENT AIR COMPRESSOR ROST REVERSE OSMOSIS STORAGE TANK DHWBP DOMEPC HOT WATER BOOSTER PUMP IAD INSTRUMENT AIR DRYER RPZ REDUCED PRESSURE BACKFLOW PREVENTER CHI DOMESTIC HOT WATER DHWR DOMESTIC HOT WATER RETURN JP JOCKEY PUMP SOR SAN SANITARY OR SEWER DI DEIONIZED WATER JPC JOCKEY PUMP SCW SOFT COLD WATER DS DOWNSPOUT SO SCUPPERDRAIN DSWBP DOMESTIC SOFT WATER BOOSTER PUMP LA LABAIR SEP SEWAGE EJECTOR PUMP DIN DISTILLED WATER LAC LABAIR COMPRESSOR SK SINK DWBP DOMESTIC WATER BOOSTER PUMP LAD LABAIR DRYER SP STORM PUMP OR SUMP PUMP DWH DOMESTIC WATER HEATER LAV LAVATORY ST STORM LV LABVACUUM STIR STARTER OR STRUCTURE ECO EXTERIOR CLEANOUT LVP LAB VACUUM PUMP STRUC STRUCTURAL EGA EQUIPMENTAIR SV SPECIALVENT EQAC EQUIPMENT AIR COMPRESSOR MA MEDICAL AIR SW SPECIALWASTE EQAI EQUIPMENT AIR INTAKE MAC MEDICAL AIR COMPRESSOR EQV EQUIPMENTVACUUM MAD MEDICAL AIR DRYER EQVP EQUIPMENT VACUUM PUMP MAI MEDICAL AIR INTAKE TMY THERMOSTATIC MIXING VALVE COW EQUIPMENT VACUUM VENT MAM MEDICAL AIR MANFOLD TW TEPID OR TEMPERED WATER ES EMERGENCYSHOWER MB MOP BASIN ESP ELEVATOR SUMP PUMP MH MANHOLE UR URINAL EW EMERGENCY EYEWASH MV MEDICAL VACUUM EWC ELECTRIC WATER COOLER MVP MEDICAL VACUUM PUMP V VENT VAC VACUUM FCO FLOOR CLEANOUT N NITROGEN VV VACUUM VENT FD FLOOR DRAIN NM NITROGEN MANIFOLD FDC FIRE DEPARTMENT CONNECTION NOM NITROUS OXIDE MANIFOLD W WASTE FH FIRE HOSE WAGD WASTE ANESTHESIA GAS DISPOSAL FHC FIRE HOSE CABINET WB WALL BOX FO FUEL OIL 0 OXYGEN WC WATER CLOSET FORT FUEL OIL DAY TANK OD OR ORD OVERFLOW DRAIN WCO WALL CLEANOUT FOP FUEL OIL PUMP OM OXYGEN MANIFOLD WH WALL HYDRANT FOR FUEL OIL RETURN OSD OPEN SITE DRAIN INS WATER SOFTENER OR WASTE STACK NOTE: ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT PLUMBING PIPING SYMBOLS ncW DOMESTIC COLD WATER —DHW— DOMESTIC HOT WATER DI WR— DOMESTIC HOT WATER CIRCULATION �CWN— SOFTCOLDWATER —TW— TEMPERED WATER �40 DHW— 140 DEG REE DOMESTIC HOT WATER CIRCULATION —140 DHWR— 140 DEG REE DOMESTIC HOT WATE R SUPPLY ------ _S SANITARY SOIL, WASTE SEWER �W SPECALWASTE VENT �V— SPECLALVENT �T STORM SEWER —FF— FIRE PROTECTION ------- PI PURE WATER LNG GAS,NATURAL —GV— GAS VENT CFO FUEL OIL �OV— FUEL OIL VENT -A— LABORATORYAIR ------- LV— LABORATORY VACUUM �QA— EQUIPMENT AIR �QV— EQUIPMENT VACUUM —CA— COMPRESSED AIR LINE SYMBOLS -- — LIGHTISCREENED SOLID OR DASHED LINES INDICATE EXISTINGTOREMNN — — — — HEAVYDASHED LINES INDICATE EXISTING TOBE REMOVED HEAVY CONTINUOUS LINES INDICATE NEW WORK LIGHT DOT LINES INDICATE FUTURE WORK PLUMBING DEMOLITION GENERAL NOTES A. IN EXISTING AREAS, EXISTING SYSTEMS SHOWN ARE BASED ON EXISTING DRAWINGS AND FIELD VERIFIED TO THE EXTENT POSSIBLE. CONTRACTOR SHALL VERIFY THAT SERVICES INDICATED FOR REMOVAL DO NOT SERVE SPACES OUTSIDE THE PROJECT AREA. CONTRACTOR SHALL FIELD VERIFY THAT EXISTING SYSTEMS SHOWN ARE REPRESENTATIVE OF THE INSTALLED SYSTEMS AND REPORT MAJOR DISCREPANCIES TO ENGINEER OF RECORD. B. FOR PHASED SCOPE OF WORK, REFERENCE ARCHITECTURAL PHASING PLANS FOR AREAS OF THE BUILDING INCLUDED IN THE SCOPE OF WORK AND THE CONSTRUCTION PHASING. CONTRACTOR SHALL VERIFY THE FIXTURES, EQUIPMENT AND PIPING TO REMAIN ACTIVE WHERE REQUIRED BY THE PROJECT PHASING AS REQUIRED TO AVOID REMOVAL OF SYSTEMS TO REMAIN. C. INACTIVE, ABANDONED SYSTEMS NOT SHOWN ARE TO BE REPORTED TO THE ENGINEER OF RECORD. D. CONTRACTOR IS TO COORDINATE ALL SERVICE INTERRUPTIONS WITH OWNER REPRESENTATIVES, MAINTENANCE STAFF, AND END -USERS. CONTRACTOR SHALL PROVIDE SUFFICIENT ADVANCE NOTICE TO ALL AFFECTED PARTIES OF IMPENDING OUTAGE. E. SYSTEMS INDICATED BY DASHED LINES OR RENDERED OBSOLETE BY CONSTRUCTION ARE TO BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE DESCRIBED BY PLAN NOTE(S). THIS INCLUDES THE REMOVAL OF EXISTING HANGERS, INSULATION, AND ASSOCIATED CONTROLS AND ACCESSORIES. ALL PIPING TERMINATIONS NOT SHOWN AS BEING REUSED SHALL BE CAPPED. CONTRACTOR SHALL PATCH INSULATION DAMAGED DURING DEMOLITION AND WHERE PIPING IS SHOWN TO BE CAPPED. F. WHEN EQUIPMENT REQUIRING ELECTRICAL POWER IS REMOVED, CONTRACTOR SHALL ALSO DEMOLISH EXISTING POWER WIRING AND CONDUIT. A LICENSED ELECTRICIAN SHALL BE RESPONSIBLE FOR REMOVING ALL POWER WIRING AND CONDUIT. G. WHERE MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE PROTECTION WORK PENETRATES EXISTING WALLS OR FLOORS TO REMAIN, THE OPENING CREATED MUST BE REPAIRED TO MATCH THE EXISTING CONSTRUCTION AND FIRE RATING BY THE GENERAL CONSTRUCTION TRADE SKILLED IN THE WORK TO BE PERFORMED. H. IF THE WORK OF OTHER TRADES IS CURRENTLY SUPPORTED BY WORK TO BE DEMOLISHED, CONTRACTOR SHALL FURNISH AND INSTALL NEW SUPPORTS. 1. UNUSED HANGERS FOUND WITHIN THE PROJECT SCOPE AREA SHALL BE REMOVED. J. THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL FOR ANY ITEMS REMOVED FROM THE PROJECT SCOPE AREA. ALL ITEMS NOT CLAIMED BY OWNER SHALL BE REMOVED FROM PREMISES. A. NEW WORK SHOWN ON DRAWINGS IS CONCEPTUAL IN NATURE. CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL TRADES. CONTRACTORSHALL PERFORM FINAL COORDINATION OF ALL TRADES AFTER CEILING REMOVAL ALLOWS FURTHER SITE INVESTIGATION ON EXISTING BUILDINGS. B. UNLESS NOTED OTHERWISEON THE DRAWINGS, REFER TO SCHEDULES FOR PIPE SIZES TO PLUMBING FIXTURES, DRAINS, AND EQUIPMENT. C. WHERE EQUIPMENT REQUIRING ACCESS MUST BE INSTALLED ABOVE GYPSUM CEILING, CONTRACTOR SHALL COORDINATE ADEQUATE ACCESS WITH ALL TRADES AND PROVIDE THE REQUIRED ACCESS PANELS. Q WHERE EQUIPMENT REQUIRING ACCESS IS INSTALLED BY PLUMBING CONTRACTOR OR OTHER TRADES, ACCESS SHALL BE COORDINATED AND SYSTEMS ROUTED TO ALLOW ACCESS TO EQUIPMENT. E. FOR PHASED SCOPE OFWORK, CONTRACTOR SHALL COORDINATE PHASING REQUIREMENTS WITH ARCHITECTURAL PHASING PLANS. F. CONTRACTOR TO COORDINATEWITH CONSTRUCTION SCHEDULE FORALL WORK PERFORMED. G. ALL PIPE PENETRATIONS SHALL BECOORDINATED WITH STRUCTURAL DRAWINGS AND EXISTING CONDITIONS. PIPE PENETRATIONS THROUGH CONCRETE BEAMS, JOISTS, OR COLUMNS ARE NOT ACCEPTABLE UNLESS SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. H. WHERE NEW PIPE PENETRATIONS THROUGH EXISTING CONCRETE SLABSARETO OCCUR, CONTRACTOR SHALL LOCATE ANY EXISTING SYSTEMS OR REINFORCING BY X- RAYISCAN PRIOR TO CORE DRILLING TO AVOID DAMAGE TO SYSTEMS OR REINFORCING. L PROVIDE WATER HAMMER ARRESTORS ATALL FLUSH VALVES AND WHERE INDICATED ON PLANS AND DETAILS IN ACCORDNACE WITH PDI-WH-201 GUIDELINES. J. NO PIPING SHALL PASS THROUGH OR BE LOCATED IN ELECTRICAL ROOMS, TELECOM ROOMS, ELEVATOR EQUIPMENT ROOMS, OR STAIR SHAFTS. A. EXISTING SYSTEMS SHOWN ARE BASED ON EXISTING DRAWINGS AND FIELD VERIFIED TO THE EXTENT POSSIBLE. CONTRACTOR SHALL VERIFY THAT SERVICES INDICATED FOR REMOVAL DO NOT SERVE SPACES OUTSIDE THE PROJECT AREA. CONTRACTORSHALL FIELD VERIFY THAT EXISTING SYSTEMS SHOWN ARE REPRESENTATIVE OF THE INSTALLED SYSTEMS AND REPORT MAJOR DISCREPANCIES TO ENGINEER OF RECORD. B. FOR PHASED SCOPE OF WORK, REFERENCE ARCHITECTURAL PHASING PLANS FOR AREAS OF THE BUILDING INCLUDED IN THE SCOPE OF WORK AND THE CONSTRUCTION PHASING. C. IN AREAS OF RENOVATION, INACTIVE AND ABANDONED SYSTEMS NOT SHOWN ARE TO BE REPORTED TO THE ENGINEER OF RECORD. D. CONTRACTOR IS TO COORDINATE ALL SERVICE INTERRUPTIONS WITH OWNER REPRESENTATIVES, MAINTENANCE STAFF, AND END -USERS. CONTRACTOR SHALL PROVIDE SUFFICIENT ADVANCE NOTICE TO ALL AFFECTED PARTIES OF IMPENDING OUTAGE. E. SYSTEMS INDICATED BY DASHED LINES OR RENDERED OBSOLETE BY CONSTRUCTION ARE TO BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE DESCRIBED BY PLAN NOTE(S). THIS INCLUDES THE REMOVAL OF EXISTING HANGERS, INSULATION, AND ASSOCIATED CONTROLS AND ACCESSORIES. ALL PIPING TERMINATIONS NOT SHOWN AS BEING REUSED SHALL BE CAPPED. CONTRACTOR SHALL PATCH INSULATION DAMAGED DURING DEMOLITION AND WHERE PIPING IS SHOWN TO BE CAPPED. F. WHEN EQUIPMENT REQUIRING ELECTRICAL POWER IS REMOVED, CONTRACTOR SHALL ALSO DEMOLISH EXISTING POWER WIRING AND CONDUIT. A LICENSED ELECTRICIAN SHALL BE RESPONSIBLE FOR REMOVING ALL POWER WIRING AND CONDUIT. G. WHERE MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE PROTECTION WORK PENETRATES EXISTING WALLS OR FLOORS TO REMAIN, THE OPENING CREATED MUST BE REPAIRED TO MATCH THE EXISTING CONSTRUCTION AND FIRE RATING BY THE GENERAL CONSTRUCTION TRADE SKILLED IN THE WORK TO BE PERFORMED. H. IF THE WORK OF OTHER TRADES IS CURRENTLY SUPPORTED BY WORK TO BE DEMOLISHED, CONTRACTOR SHALL FURNISH AND INSTALL NEW SUPPORTS. I. UNUSED HANGERS FOUND WITHIN THE PROJECT SCOPE AREA SHALL BE REMOVED. A. WHERE RENOVATIONS OCCUR, MODIFY EXISTING SPRINKLER COVERAGE TO ACCOMMODATE NEW LAYOUT. REFER TO ARCHITECTURAL PLANS FOR CHANGES TO THE AREA OF SCOPE COORDINATE SYSTEMS WITH EXISTING AND NEW SERVICES. B. WHERE EQUIPMENT REQUIRING ACCESS MUST BE INSTALLED ABOVE GYPSUM CEILING, CONTRACTOR SHALL COORDINATE ADEQUATE ACCESS WITH ALL TRADES AND PROVIDE THE REQUIRED ACCESS PANELS. C. WHERE EQUIPMENT REQUIRING ACCESS IS INSTALLED BY FIRE PROTECTION CONTRACTOR OR OTHER TRADES, ACCESS SHALL BE COORDINATED AND SYSTEMS ROUTED TO ALLOW ACCESS TO EQUIPMENT. D. WHERE PROJECT SCOPE IS PHASED, CONTRACTOR SHALL COORDINATE PHASING REQUIREMENTS WITH ARCHITECTURAL PHASING PLANS. E. CONTRACTOR TO COORDINATE WITH CONSTRUCTION SCHEDULE FOR ALL WORK PERFORMED. F. WHERE NEW WORK IS BEING PERFORMED ON AN EXISTING BUILDING, CONTRACTOR SHALL SCHEDULE SHUTDOWN OF EXISTING FIRE SUPPRESSION SYSTEM WITH OWNER AND NOTIFY LOCAL FIRE DEPARTMENT OF SYSTEM AND AREAS OUT OF SERVICE. PROVIDE FIRE WATCH OF AREAS AND SYSTEMS AFFECTED. G. SPRINKLER PIPING SERVING ELECTRICAL ROOMS, TELECOM ROOMS, AND OTHER SIMILAR SPACES SHALL BE MINIMIZED TO ONLY THE SPRINKLER PIPING AND HEAD THAT SERVES THE SPACE. SPRINKLER PIPING SERVING THESE SPACES SHALL BE ROUTED IN SUCH A MANNER TO MINIMIZE PIPING WITHIN THE ROOM AND SHALL NOT BE ROUTED OVER ELECTRICAL PANELS OR EQUIPMENT WITHIN THE ROOM. H. ALL PIPE PENETRATIONS SHALL BE COORDINATED WITH STRUCTURAL DRAWINGS AND EXISTING CONDITIONS. PIPE PENETRATIONS THROUGH CONCRETE BEAMS, JOISTS, OR COLUMNS ARE NOT ACCEPTABLE UNLESS SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. I. FIRE PROTECTION CONTRACTOR TO PROVIDE A COMPLETE AND OPERABLE SYSTEM IN ACCORDANCE WITH NFPA, STATE, AND LOCAL CODES. COORDINATE WIRING OF FIRE ALARM DEVICES WITH ELECTRICAL CONTRACTOR. BSA LifeStructures 9365 Counselors Row Suite 300 Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www. bsal'Ifestructures.00m VISIONFIRST Indiana Lions Eye Bank OFFICE AND LAB RENOVATION CLIENT PROJECT NO. - 21160001 CONSTRUCTION DOCUMENTS MARK I DATE I DESCRIPTION PLUMBING SYMBOLS, ABBREVIATIONS AND GENERAL NOTES RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel ' V"IDI DATE: 02/20/19 DATE DEC. 19, 2018 EISALS PROJECT NO. 21160001 P001