Loading...
HomeMy WebLinkAboutP 800H TERMINATE SLEEVE FLUSH WITH FINISHED WALL PIPE FIRESTOP EACHSIDE OF SLEEVE AS SPED FED IN DIV 7 FINISHED WALL SURFACE OF RATED ASSEMBLY TERMINATE SLEEVE FLUSH WITH FINISHED WALL RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel �N;1�v�lDw�,DAS� DATE: 02/20/19 PIPE PIPE SLEEVE TO BE SIZED TO PASS PIPE THRU SLEEVE AND ALLOW SPACE FOR SEALANT TO MEET UL-LISTING SLEEVE WATER STC WALL O PIPE SLEEVE TO BE SIZED TO PASS PIPE AND INSULATION THRL AND ALLOW SPACE FOR ED PIPE FIRESTOP EACH SIDE PI PE I NSULATION TO OF SLEEVE AS CONT THRU WALL SPECIFIED IN DIV 7 NONCOMBUSTIBLE FINISHED WALL SURFACE SEALANT OF RATED ASSEMBLY FINISHED WALL SURFACE INSULATED PIPE THROUGH INSULATED OR UNINSULATED PIPE INTERIOR FIRE RATED WALLS THROUGH INTERIOR NON -RATED WALLS NOTES; OR SMOKE -RESISTANT CORRIDOR WALLS O PROVIDE ESCUTCHEON PLATE FLUSH AGAINST WALL AND OF SIZE TO COMPLETELY COVER OPENING IN EXPOSED AREAS ONLY. O2 SEE SPECIFICATION SECTIONS FOR FURTHER REQUIREMENTS INCLUDING FLOOR SLEEVES. O LOCATE FIRESTOP LABEL ON EACH SIDE OF PENETRATION SO THAT IT IS VISIBLE FROM AN ACCESSIBLE LOCATION ABOVE CEILING. O4 INCLUDES FIRE WALLS, FIRE BARRIERS, SMOKE BARRIERS, AND FIRE PARTITIONS, �1 PIPE PENETRATION DETAILS NO SCALE EXTERIORWALLS SEESPECFOR COTYPES CLEANOUT SIZES _III, PIPE SIZE CLEANOUT SIZE = z^ r 3' T 4- 4- IF & LARGER 4- CI EXTENSION; SEE SG-1 FOR SIZE �- CI COMBINATION'N & 118 BEND (USE REDUCING TYPE WHERE REG O) SEWER MATERIAL& SIZE AS SPECIFIED FLOOR CLEANOUT DETAIL NO SCALE EXISTING TO REMAIN - REDUCED PRESSURE EXISTING WATER BACKFLOW PREVENTER METER VAULT r mi INCOMING DOMESTIC WATER L rt J CITY SERVICE EXISTING UTILITY SHUT-OFF SUPPLIED WATER VALVE METER DRAIN LINE AIR GAP FITTING G ILEEVE PIPE 1TIC PIPE ['LINK -SEAL' 9LL ANNULAR GAPS ,ROUND PIPES ON ACH SIDE OF WALL SSEMBLY PLUMBING EQUIPMENT SCHEDULE EQUIPMENT DESIGNATI ON EQUIPMENT NAME MANUFACTURER MODEL LOCATION RATED CAPACITY BUILIDING AUTOMATION CONNECTIONS ELECTRICAL LOAD NOTES INLET OUTLET kW HP VOLTS PHASE EMERGENCY POWER KAIC RATING TMV-1 THERMOSTATIC MIXINGVALVE LAWLER 5701 BIOHAZARD JANRORY WGPM @30 PSI P.D. No 39' 39' No NGM-1 NATURAL GAS METER VECTREN PROVIDED BY UTILITY EXTERIOR OF BUILDING 32M CFH@2 PSIG No 2- 2- No UTILITY SUPPLIED NATURAL GAS METER 2 PSIG SERVICE. DWHI P. O.0 WATER HEATER EEMAX EX3012T VARIOUS LOCATIONS (SEE PLANS) 2GPM No 12' 12' 3 120 1 No MOUNT ON WALL BELOW CASEWORK. DWH-2 DOMESTIC WATER HEATER A . SMITH DEL-20 BIO-HAZARD JANITORY 20 GAL No 3W' 30' 4.5 POB 1 No MOUNT UNIT ON WALL SHELF. TB P RELIEF VALVE ROUTED TO DRAIN. PLUMBING DRAIN SCHEDULE DRAIN DESIGNATION QUANTITY CONNECTIONS NOTES VENTNVET VENT WASTEISTORM 2"FD-1 6 0' 2' SCORIATED BRONZE - TOP (WHEN SPFCI PIP DI CI lyau11014 RONZE TOP RECESSED( THREADED Q PLUG - ADJHEAD ,DED CO PLUG RULE W/CUT- FERRULE WI SECTTIONS CO% CUT-OFF SECTIONS I-114'DIA CCMAF VRPET - CC N� I TERRAZZO OR CERAMIC FINISHED FLOORS TILED FLOORS WASTE LINE OR WET VENT AIR—G NO SCALEAP DRAIN DETAIL DOMESTIC WATER OUT TO SYSTEM PROVIDE NEW PRESSURE REDUCING VALVE SET TO 70 PSI WITH LOW FLOW BY-PASS SET TO 75 PSI. ISOLATION VALVE (TYP) WTER SERVICE ENTRANCE DIAGRAM NOS CALE GAS COCK(TYP) - CARPETED FLOORS 3 FLOOR CLEANOUT DETAIL NO SCALE LANGEP T` P, GAS REGULATOR STRAINER 4 NATURAL GAS PRESSURE REDUCING STATION DETAIL NO SCALE 314' DOW (COPPER) CHECK VALVE (TYP) F Imd CAR PAD :ADED CO PLUG RESILIENT TILED FLOORS TOT AL N.G. CONNECTED LOAD. EXISTING LOAD: 1,500 CFH @2 PSIG. NEW LOAD: 3,600 CFH (rg 2 PSIG. DISTANCE TO FURTHEST RUN: 300 FT. FULL SIZE VENT PIPED TO ATM LNION PRESSURE GAUGE; RANGE APPROPRIATE TO PRESSURE(TYP) GAUGE COCKFYP) 314' T T T ASMEPBT RELIEF VALVE P ♦` 3'4. TEMPERATURE& X PRESSURE GAUGES (TYP) 34' THERMOSTATIC MIXING VALVE OWH-3 I EXPANSIOf4 (TMV-1) TANK ET-1 NT yp ATED ON :ALLHE AIR GAP TO BE SLF,PROVIDED OVER E CEILING FLOORDRAIN i1 DOMESTIC WATER HEATER PIPING NOSCALE PLUMBING FIXTURE SCHEDULE FIXTURE DESIGNATIO N QUANTITY CONNECTIONS REMARKS CW HW VENT WASTE TRAP SIZE EWC-1 1 12' 2- 2- 1112, LAV-1 6 12' 12' 2- 2- 1112' MB.1 1 314' 314' 2- T T SK-1 1 12' 12' 2- 2- 1112 SK-2 5 12' 12' 2- 2- 1112' $K-3 1 12' 12' 2- 2- 1112, UR-1 1 3'4' 2' 2' UR-2 1 314' 2- 2- WC-1 1 1114' 2 4' Elongated floor mount flushometer valve tales less Wemlcan. CLEANOUT SIZES PIPE SIZE CLEANOUT SIZE 4' 4' EXTERIORWALL 6' 4' EXTERIOR CO(TYP) B. 4' 3030- MIN 24'X24'X6' DEEP CONCRETE PAD GRADE FOUNDATION WALL BUILDING FOOTINGS 1 E=IF-`I-I�JIF=11 EXTERIOR TWO—WAY SANITARY CLEANOUT DETAIL NO SCALE — PIPE EXTENSION. SEE SCHEDULE FOR SIZE(TYP) DOUBLE TWO-WAY CLEANOUT SEWER MATERIAL& SIZE AS SPECIFIED REFERTO PLANS FOR INV ELEV BSA BSA LifeStructures 9365 Counselors Row Suite 300 Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www. tIsal'Ifestructures.00m VISIONFIRST Indiana Lions Eye Bank OFFICE AND LAB RENOVATION CLIENT PROJECT NO. - 21160001 CONSTRUCTION DOCUMENTS T KEYPLAN aLAN Nonni MARK DATE DESCRIPTION 2 1 0112Z2019 JADDENDUM2 PLUMBING DETAILS AND SCHEDULES DATE DEC.19,2818 BSALS PROJECT N0. 21160001 P800