HomeMy WebLinkAbout19020065 Energy CertificateIECC 2009 Performance Compliance
Property
1576 JENSEN DR
CARMEL, IN 46032
CCO27 (AS DESIGNED)
CLAY CORNER 27
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,299
$217
$385
$1,901
$670
$0
$2,571
Requirements
C4405.3
Performance -based compliance passes by 9.8%
402.4.1.2
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U-Factor
40322
Duct. Testing
C4
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
CTSI
Energy Solutions
As Designed
$1,152
$178
$385
$1,715
$670
$0
$2,386
Air sealing is 5.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 9.8%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
1123/19 at 3:05 PM
Ekotrope RATER - Version 3.1.0.2094
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
1576 JENSEN DR
CARMEL, IN 46032
LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 5 ACH50
Window U-Value: 0.33, SHGC: 0.28
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 150.0 CFM @ 25Pa
Total Duct Leakage 240.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 1123/19 at 3:05 PM
Ekotrope RATER - Version 3.1.0.2094
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
1576 JENSEN DR
CARMEL, IN 46032
CCO27 (AS DESIGNED)
CLAY CORNER 27
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
3,074
26,731
7,442
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identity any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (2,139 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB 2X4 (2,413 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CON DIGAR (180 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (408 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Li Name: BAND CONDIAMB (67 s.f.) 1
R: 13.575
Energy Code Inspection Checklist
Property
1576 JENSEN DR
CARMEL, IN 46032
CCO27 (AS DESIGNED)
CLAY CORNER 27
Name: CONDIATTIC (64 s.f.)
R: 13.575
Roof
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
El Name: SECOND (2,139 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (24 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
El Name: FRONT (120 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH
El Name: BACK (90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH
11 Name: LEFT SIDE (93 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST
11 Name: LEFT SIDE GD (20 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST
Name: BSMT (32 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST
E] Name: RIGHT SIDE (73 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST
E] Name: BSMT (16 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
None Present
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property
1576 JENSEN DR
CARMEL, IN 46032
CCO27 (AS DESIGNED)
CLAY CORNER 27
Mechanical Equipment
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE
M Air conditioner • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 2,228 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 150.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 240.0 CFM @ 25Pa
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property
1576 JENSEN DR
CARMEL, IN 46032
CCO27 (AS DESIGNED)
CLAY CORNER 27
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
5N5
4
Building Summary
Property
1576 JENSEN DR
CARMEL, IN 46032
CCO27 [AS DESIGNED]
CLAY CORNER 27
General Building Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq. ft.]
Unconditioned, attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Model
Community
Climate Zone
Basement Wall
Basement Wall Library List
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
4
2
3:074
Yes
26;731
1
Single family detached
PENNINGTON (C)
CLAY CORNER 27
5A
None Present
None Present
Inspection Status
Results are projected
C-M,
Energy Solutions
Slab Am
Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
SLAB R-10, 2'down
217 On Grade 0
0 2.139.0 sq. ft. Exposed Exterior
Conditioned
Space
Slab Library LisOEM"
0
Name Wall Construction Type
Slab Completer Llnderslab Insulation
Perimeterinsu}ation Perfineterinsu}ation R
R-value
Insulated . Width [ft]
Depth r] Value
IR-10, 2'down Woad Frame / Other
No 0
2 10
0.00
Framed Floor E
None Present
1
Building Summary
Property
Organization
1576 JENSEN DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
CCO27 [AS DESIGNED]
Builder
CLAY CORNER 27
LENNAR HOMES
Framed Floor Library List
Rim Joist
Name
BAND CONDIAMB
CONDIATTIC
Rim Joist Library List
Name
G1 R-13. R-3.0
C-M,
Energy Solutions
Inspection Status
Results are projected
G1 R-13, R-3.0 67.0 sq.ft. Exposed Exteror
G1 R-13, R-3.0 64.0 sq. ft. Attic
■
R-value
13.575
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB 2X4
Exposed Exterior
G1 R-13 BATT, R-3.0
Medium
2,413.0 sq. ft.
CONDIATTIC
Attic
G1 R-13 BATT, R-3.0
Medium
408.0 sq. ft.
CONDIGAR
Unconditioned, attached garage
G1 R-13 Gar Walls
Medium
180.0 sq. ft.
Wall Library List
Name
R-value
G1 R-13 BATT, R-3.0
15.12
G1 R-13 Gar Walls
11.141
1
2
Building Summary
Property Organization
Energy
C-M
Solutions
1576 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Inspection Status
CCO27 [AS DESIGNED] Builder
Results are projected
CLAY CORNER 27 LENNAR HOMES
Glazin
Name Library Type Wall Assignment Basement Wall Overhang
Assignment
Depth Overhang Pt
7bp
To Overhang Pt Ta
Bottom
Orientation
Surface Area
BACK 11-.33, SHGG28 CONDIAMB 2X4
❑
❑ ❑
North
90.0 sq. ft
BSMT U-.33, SHGG28
0
0 0
West
32.0 sq. ft
BSMT U-.33, SHGG28 CONDIAMB 2X4
0
0 0
East
16.0 sq. R
FRONT U-.33, SHGG28 CONDIAMB 2X4
0
0 ❑
South
120.0 sq. H.
LEFT SIDE 11-.33, SHGG28 CONDIAMB 2X4
0
0 ❑
West
93.0 sq. ft
LEFT SIDE GD 11-.33, SHGG28 CONDIAMB 2X4
0
0 ❑
West
20.0 sq. fL
RIGHT SIDE 11-.33, SHGG28 CONDIAMB 2X4
0
0 ❑
East
73.0 sq. ft
Glazing Library List
Name Shg c
U factor
U-.33, SHGC-28 028
0.330
Skylight
None Present
Skylight Library List
None Present
Opaque Danr
Name Library Type VhIIAssignmertl
FRONT Fiberglass Door CONDIAMB 2X4
GARAGE Fiberglass Door CONDIGAR
sement Wall Emittance Solar Surface Color Surface Area
Assign ment Absorpta nce
0.9 0.75 Medium 24.0 sq. ft Exposed Exterior
0.9 0.75 Medium 18.0 sq. ft Exposed Exterior
Building Summary
Property
1576 JENSEN DR
CARMEL, IN 46032
CCO27 [AS DESIGNED]
CLAY CORNER 27
Opaque Door Library List
Name
Fiberglass Door
Roof Insulation
Name Library Typ
SECOND R-38 Blown, GR1
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
0.182
krea clay or
Vt.]
Inspection Status
Results are projected
Tiles
C-M,
Energy Solutions
n
2,139 No Medium 2,139.0 sq. fl- Attic
Roof Insulation Library List
Name Has Radiant Barrier R-value
'•0 3 •cr. -I :a l No 38268
Whole House Infiltration +
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
Shelter Class
4
I
Lighting
% Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting
Lighting Lighting Lighting
0 100 0 700 0 100
4
Building Summary
Property
1576 JENSEN DR
CARMEL, IN 46032
CCO27 [AS DESIGNED]
CLAY CORNER 27
Onsite Generation
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Gnsite Generation Library List _
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipmenl
Name
Air conditioner
Fuel4red air
distribution
Water Heatina
C-M,
Energy Solutions
Inspection Status
Results are projected
Heating Percent Load Cooling Percent Load Hot Water
CA13NA042 0% 1 OD%
915SA42060S17 100% 0%
0%
0%
RE350" 0% 0% 100%
Equipment Type: 915SA42060S17
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 95.5 AFUE
Heating Capacity [kBtulh] 58
Use default EAE No
EAE [kWh] 636
5
Building Summary
Property
1576 JENSEN DR
CARMEL, IN 46032
CCO27 [AS DESIGNED]
CLAY CORNER 27
■
Equipment Type: CA13NA042
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
Electric
Forced Air
PSG (Single Speed)
13 SEER
40
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
C-M,
Energy Solutions
Building Summary
Property
Organization
1576 JENSEN DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Inspection Status
CCO27 [AS DESIGNED]
Builder Results are projected
CLAY CORNER 27
LENNAR HOMES
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel-f red air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
3074
# Return Grilles
3
Supply Duct R Value
10
Return Duct R Value
10
Supply Duct Area [sq. ft.]
829.98
Return Duct Area [sq. ft_]
461.1
Duct Leakage to Outdoors (CFM25)
150
Total Leakage
240
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct t
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Ceiling Fan
'
Has Ceiling Fan
No
Cfm Per Watt
101
Water Distribution
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
65
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
34
Drain Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
1576 JENSEN DR
CARMEL, IN 46032
CCO27 [AS DESIGNED]
CLAY CORNER 27
Fuel Type
Cef
Field Utilization
lothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
F5NMO
5
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
Electric
Timer Controls
704 kWh/Year
0.0nWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
C-M,
Energy Solutions
,�