HomeMy WebLinkAbout19020065 Energy CertificateIECC 2009 Performance Compliance Property 1576 JENSEN DR CARMEL, IN 46032 CCO27 (AS DESIGNED) CLAY CORNER 27 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,299 $217 $385 $1,901 $670 $0 $2,571 Requirements C4405.3 Performance -based compliance passes by 9.8% 402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct. Testing C4 Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation CTSI Energy Solutions As Designed $1,152 $178 $385 $1,715 $670 $0 $2,386 Air sealing is 5.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 9.8%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 1123/19 at 3:05 PM Ekotrope RATER - Version 3.1.0.2094 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 1576 JENSEN DR CARMEL, IN 46032 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.33, SHGC: 0.28 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 150.0 CFM @ 25Pa Total Duct Leakage 240.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 1123/19 at 3:05 PM Ekotrope RATER - Version 3.1.0.2094 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 1576 JENSEN DR CARMEL, IN 46032 CCO27 (AS DESIGNED) CLAY CORNER 27 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 3,074 26,731 7,442 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (2,139 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall El Name: CONDIAMB 2X4 (2,413 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CON DIGAR (180 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (408 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Li Name: BAND CONDIAMB (67 s.f.) 1 R: 13.575 Energy Code Inspection Checklist Property 1576 JENSEN DR CARMEL, IN 46032 CCO27 (AS DESIGNED) CLAY CORNER 27 Name: CONDIATTIC (64 s.f.) R: 13.575 Roof Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES El Name: SECOND (2,139 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (24 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (120 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH El Name: BACK (90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH 11 Name: LEFT SIDE (93 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST 11 Name: LEFT SIDE GD (20 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST Name: BSMT (32 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST E] Name: RIGHT SIDE (73 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST E] Name: BSMT (16 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST Skylight None Present Mechanical Ventilation None Present C-M, Energy Solutions 2 Energy Code Inspection Checklist Property 1576 JENSEN DR CARMEL, IN 46032 CCO27 (AS DESIGNED) CLAY CORNER 27 Mechanical Equipment Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected 0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE M Air conditioner • Electric • 100% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 2,228 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 150.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 240.0 CFM @ 25Pa C", Energy Solutions 3 Energy Code Inspection Checklist Property 1576 JENSEN DR CARMEL, IN 46032 CCO27 (AS DESIGNED) CLAY CORNER 27 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 5N5 4 Building Summary Property 1576 JENSEN DR CARMEL, IN 46032 CCO27 [AS DESIGNED] CLAY CORNER 27 General Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq. ft.] Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Model Community Climate Zone Basement Wall Basement Wall Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 4 2 3:074 Yes 26;731 1 Single family detached PENNINGTON (C) CLAY CORNER 27 5A None Present None Present Inspection Status Results are projected C-M, Energy Solutions Slab Am Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area SLAB R-10, 2'down 217 On Grade 0 0 2.139.0 sq. ft. Exposed Exterior Conditioned Space Slab Library LisOEM" 0 Name Wall Construction Type Slab Completer Llnderslab Insulation Perimeterinsu}ation Perfineterinsu}ation R R-value Insulated . Width [ft] Depth r] Value IR-10, 2'down Woad Frame / Other No 0 2 10 0.00 Framed Floor E None Present 1 Building Summary Property Organization 1576 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons CCO27 [AS DESIGNED] Builder CLAY CORNER 27 LENNAR HOMES Framed Floor Library List Rim Joist Name BAND CONDIAMB CONDIATTIC Rim Joist Library List Name G1 R-13. R-3.0 C-M, Energy Solutions Inspection Status Results are projected G1 R-13, R-3.0 67.0 sq.ft. Exposed Exteror G1 R-13, R-3.0 64.0 sq. ft. Attic ■ R-value 13.575 Name Library Type Surface Color Surface Area Location CONDIAMB 2X4 Exposed Exterior G1 R-13 BATT, R-3.0 Medium 2,413.0 sq. ft. CONDIATTIC Attic G1 R-13 BATT, R-3.0 Medium 408.0 sq. ft. CONDIGAR Unconditioned, attached garage G1 R-13 Gar Walls Medium 180.0 sq. ft. Wall Library List Name R-value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 1 2 Building Summary Property Organization Energy C-M Solutions 1576 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CCO27 [AS DESIGNED] Builder Results are projected CLAY CORNER 27 LENNAR HOMES Glazin Name Library Type Wall Assignment Basement Wall Overhang Assignment Depth Overhang Pt 7bp To Overhang Pt Ta Bottom Orientation Surface Area BACK 11-.33, SHGG28 CONDIAMB 2X4 ❑ ❑ ❑ North 90.0 sq. ft BSMT U-.33, SHGG28 0 0 0 West 32.0 sq. ft BSMT U-.33, SHGG28 CONDIAMB 2X4 0 0 0 East 16.0 sq. R FRONT U-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ South 120.0 sq. H. LEFT SIDE 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ West 93.0 sq. ft LEFT SIDE GD 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ West 20.0 sq. fL RIGHT SIDE 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ East 73.0 sq. ft Glazing Library List Name Shg c U factor U-.33, SHGC-28 028 0.330 Skylight None Present Skylight Library List None Present Opaque Danr Name Library Type VhIIAssignmertl FRONT Fiberglass Door CONDIAMB 2X4 GARAGE Fiberglass Door CONDIGAR sement Wall Emittance Solar Surface Color Surface Area Assign ment Absorpta nce 0.9 0.75 Medium 24.0 sq. ft Exposed Exterior 0.9 0.75 Medium 18.0 sq. ft Exposed Exterior Building Summary Property 1576 JENSEN DR CARMEL, IN 46032 CCO27 [AS DESIGNED] CLAY CORNER 27 Opaque Door Library List Name Fiberglass Door Roof Insulation Name Library Typ SECOND R-38 Blown, GR1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 0.182 krea clay or Vt.] Inspection Status Results are projected Tiles C-M, Energy Solutions n 2,139 No Medium 2,139.0 sq. fl- Attic Roof Insulation Library List Name Has Radiant Barrier R-value '•0 3 •cr. -I :a l No 38268 Whole House Infiltration + Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested Mechanical Ventilation Shelter Class 4 I Lighting % Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting 0 100 0 700 0 100 4 Building Summary Property 1576 JENSEN DR CARMEL, IN 46032 CCO27 [AS DESIGNED] CLAY CORNER 27 Onsite Generation Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Gnsite Generation Library List _ None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipmenl Name Air conditioner Fuel4red air distribution Water Heatina C-M, Energy Solutions Inspection Status Results are projected Heating Percent Load Cooling Percent Load Hot Water CA13NA042 0% 1 OD% 915SA42060S17 100% 0% 0% 0% RE350" 0% 0% 100% Equipment Type: 915SA42060S17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 58 Use default EAE No EAE [kWh] 636 5 Building Summary Property 1576 JENSEN DR CARMEL, IN 46032 CCO27 [AS DESIGNED] CLAY CORNER 27 ■ Equipment Type: CA13NA042 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Electric Forced Air PSG (Single Speed) 13 SEER 40 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 C-M, Energy Solutions Building Summary Property Organization 1576 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status CCO27 [AS DESIGNED] Builder Results are projected CLAY CORNER 27 LENNAR HOMES Distribution System Distribution Type Forced Air Heating Equipment Fuel-f red air distribution Cooling Equipment Air conditioner Sq. Feet Served 3074 # Return Grilles 3 Supply Duct R Value 10 Return Duct R Value 10 Supply Duct Area [sq. ft.] 829.98 Return Duct Area [sq. ft_] 461.1 Duct Leakage to Outdoors (CFM25) 150 Total Leakage 240 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct t Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan ' Has Ceiling Fan No Cfm Per Watt 101 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 65 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 34 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 1576 JENSEN DR CARMEL, IN 46032 CCO27 [AS DESIGNED] CLAY CORNER 27 Fuel Type Cef Field Utilization lothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption F5NMO 5 Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Electric Timer Controls 704 kWh/Year 0.0nWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year C-M, Energy Solutions ,�