HomeMy WebLinkAbout[2] 181121 LOT 17 HVAC-M101LINED RA PLENUM BOX FULL SIZE OF FAN COIL INLET REFRIGERATION PIPING. INSTALL PER MANUFACTURES RECOMMENDATIONS SUPPLY AIR DUCTING 45 DEG RECTANGULAR DUCT BRANCH OCL CONNECTION J/ TAKE OFF. HAMMER LOCKED OR FLANGED AND FULLY SEALED ROUND SHEET METAL DUCT TO DIFFUSER V.D. 45 DEG. HIGH EFFICIENCY TAKE OFF COMPLETELY SEALED FILTER RACK FAN COIL ELECTRIC HEATER SCHEDULE MARK MANUFCTR MODEL NO. HEATING KW VOLTAGE PHASE ACCESSORIESIREMARKS AWH QMARK AWH4407F 3.0 240 1 iO EUH QMARK MUH0381 3.0 240 1 iO O RECESSED WALL HEATER, PROVIDE WI INSULATED OUTSIDE AIR DUCT WITH MOTORIZED AND MANUAL DAMPER.ROUTE TO WALL CAP RETURN AIR DUCTING 20" MIN WORK AREA CAP AND PROVIDE WATER SHUT OFF SWITCH IN DRAIN PAN. j PVC DRAIN FROM TRAP W ITH CLEAN OUT. SLOPE AT MIN'. PER FOOT AND SUPPORT TO STRUCTURE MINIMUM 5' O.C. SECONDARY DRAIN PAN, EXTEND MINIMINUM 6" PAST ENTIRE FAN COIL SUPPORT AT MINIMUM 16" O.C. f�HORIZONTAL FAN COIL DETAIL ~ SCALE: NONE 30° MAX I O rc �_ a 30° MAX ECCENTRIC TRANSITION MAX, 30 DEG. OFFSET. PROVIDE MINIMUM 2" STRAIGHT SECTION AT EACH END. MAX 30 DEG. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 02/28/19 N NOTE: IN GENERAL, ELBOWS TO HAVE FULL TURNING RADIUS (R-A). WHERE "R" IS EQUAL TO OR GREATERTHAN"A" MINIMUM RADIUS (R) = 4 INCHES. CONCENTRIC TRANSITION MAX, 45 DEG. DIVERGING AND 60 DEG. CONVERGING NOTE: DOUBLE THICKNESS TURNING VANES TO BE USED WHERE NORMAL RADIUS ELBOW IS IMPRACTICAL 8 WHERE ELBOW IS WITHIN 5 FT OF A BRANCH TAKE -OFF. DUCT CONSTRUCTION DETAILS B\itvSCALE: NONE HP-1 HP-2 5Ton 5Ton �1 �1 0LEVEL 1 HVAC PLAN SCALE: 1/4" = 1'-0" GOODERUM & ASSOCIATES ENGINEERING MEP Engineer 874Chelenham Way Avon, IN 46123 AL P: 31].506.81506.8151 F: 317.]45.5761 E: dave®gnaengineenng.00m GENERAL NOTES: 1. REFERENCE SHEET M-001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. REFENRENCE SHET M-102 FOR SCHEDULES AND DETAILS. KEY NOTES: O INSTALL ELECTRIC UNIT HEATER IN SPRINKLER RISER ROOM. COORDINATE WITH SPRINKLER CONTRACTOR. O SHELL SPACE HVAC SYSTEM. PROVIDE HORIZONTALLY HUNG FAN COIL AND HEAT PUMP UNIT. STUB OUT RETURN PLENUM TAP AND CONNECT FRESH AIR DUCT TO WALL CAP. STUB OUT SA DUCT AND PROVIDE THERMOSTAT. CHECK TEST AND START SYSTEM FOR FUTURE TENANT BUILD OUT. SEE DETAILS ON SHEET M002. COORDINATE FINAL LOCATION WITH G.C. O INSTALL ARCHITECTURAL ELECTRIC WALL HEATER IN STAIR WELL ENTRY. i nW- L n O M U z V LL J m W LU F� z0 U p LH w w IiUO N LLB � d r r O � � W � Z � O O � z w ~ O O � LL U N r U U w z C � w w u5=z u K O fO uriQ2 �c�Uw o U a4a a z a'u Su Nia 0 w SHEET NO LEVEL HVAC PLAN DATE I2/9/18 M101