HomeMy WebLinkAbout[2] G001_LIFE SAFETY PLAN-Layout1RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of CaRnE�ed
�VT�VH�O*141WML_
DATE: \ 02/28/19
LEVEL TWO LIFE SAFETY
2
SCALE: 114" =1' - 0"
1 LEVEL ONE LIFE SAFETY
SCALE: 114" =1' - 0"
APPLICABLE CODES
CODE
DESCRIPTION
COMPRISED OF
GENERAL ADMINISTRATION
RULES
GENERAL ADMINISTRATION
RULES (GAR) (UPDATED 8.12014)
(AMENDED 12.1.2014)
6751AC 12
BUILDING CODE
(INDIANA AMENDMENTS)
2014 INDIANA BUILDING CODE 1675
HAD 13M)
EFFECTIVE DECEMBER 1, W14
2012 INTERNATIONAL
BUILDING CODE IXB IAD 132.6
FIRE CODE
(INDIANA AMENDMENTS)
2014 INDIANA FIRE CODE(IFC)
EFFECTIVE DECEMBER 1, 2014
2012 INTERNATIONAL FIRE CODE
675INC 22-2S
PLUMBINGCODE
(INDIANA AMENDMENTS)
2012 INDIANA PLUMBING CODE
(IPO)
EFFECTIVE DECEMBER 24,2012
2" INTERNATIONAL PLUMBING
CODE
6751AD 16-IA
ELECTRICAL CODE
(INDIANA AMENDMENTS)
21XA INDIANA ELECTRICAL WDE(IEC)
EFFECTIVE AUGUST 26, 2009
2008 NFPA 70
6751AC 17-1.8
MECHANICAL CODE
(INDIANA AMENDMENTS)
2014 INDIANA MECHANICAL CODE(675
HAD 16-1.6) EFFECTIVE DECEMBER I,
2014
2012 INTERNATIONAL MECHANICAL
CODE
6751AC 181
HANDICAPPED ACCESSIBILITY
CODE (INDIANA AMENDMENTS)
2008 INDIANA BUILDING CODE
CHAPTER 11-ACCESSIBILITY
6751AC 13-2.5-12 CHAPTER II
ENERGY CODE
(INDIANA AMENDMENTS)
2010 INDIANA ENERGY CONSERVATION
CODE(HECC)
EFFECTIVE MAY T, 2010
ASHRAE STANDARD 90A, 2007
6751AC 194
ELEVATOR SAFETY CODE
2011 INDIANA ELEVATOR SAFETY CODE
(IESC)
(UPDATED 42811)
675IAD 21- ANSI I ASMEAIT.1, 2007
ANSI I ASME A90.1, SIAS
ANSI IAIOA, 2004
ASME I At 8.1, W05
BUILDING REHABILITATION
STANDARD
(INDIANA AMENDMENTS)
INDIANA BUILDING REHABILITATION
STANDARD (GAR)
(UPDATED 12.2M)
(REPEALED JUNE 18.2008
6751AC 12-8
SANITARY CODE
(INDIANA AMENDMENTS)
1998 AMERICAN SOCIETY OF
SANITARY ENGINEERS STANDARD
1051
6751AC 16-2
CODE ANALYSIS
CONSTRUCTION TYPE
VB
OCCUPANCY CLASSIFICATION
LEVEL EXISTING -B AND U-PRIVATE GARAGE
LEVEL PROPOSED - AD(SHELL ONLY - FUTURE REST)
LEVEL 2 EXISTING - R2
LEVEL 1 PROPOSED -B -GENERAL OFFICE
AREAS - LEVEL ONE
LEVEL ONE EXISTING 31X)4 SO FT
LEVEL ONE PROPOSED 2350 SF
TOTAL AREA- 5354 SF
ALLOWABLE AREA
A2- MOST RESTRICTIVE- 60005E MAX ALLOWABLE
AREAS - LEVEL TWO
LEVELTWO EXISTING 2798 SO FT
LEVEL TWO PROPOSED 22M BE
TOTAL AREA- 50M SF
FIRE PROTECTION
EXISTING NON -SPRINKLED
PROPOSED -SPRINKLED ( ADDITIONAL STORY ALLOWED)
AREA SEPARATION - FIRE BARRIER
(2) AR WALL TO SEPARATE SPRINKLED FROM NON -SPRINKLED
RATED GO RRI DORS
RATED CORRIDORS NOT REQ'D - SEC 1018 EX
OCCUPANT LOAD -LEVEL ONE
3004 SF 115 = 200 OCCUPANTS -FUTURE
OCCUPANT LOAD -LEVEL TWO
22355E I100 = 23 OCCUPANTS
EXITS REQUIRED LEVEL ONE
2MEANS OF EGRESS- OCCUPANCIES GREATER THAN SO
EXITS REQUIRED LEVEL TWO
SINGLE MEANS OF EGRESS- OCCUPAN CIES LESS THAN
DEAD END CORRIDORS
NONE- BUILDINGS REQUIRING ONLY ONE EXIT
MAX TRAVEL DI STANCE
MEASURED 79- ALLOW . 109-TABLE 1014.3-LESS THAN
STAIRS
NON -ENCLOSED PER 1009.3 EX I
EGRESS DOOR HARDWARE REQUIREMENTS
NO REQUIREMENT PER 1008.1.10
EGRESS DOOR SWING
NO REQUIREMENT PER 10M1.2
MOP SINK -1 PROVIDED PER FLOOR
WATER COOLER - EACH TENANT TO PROVIDE BOTTLED WATER IN LIEU OF
DRINKING FOUNTAINS
U
W
N0
LL
a
(/
fL
1m
am
O
W
Z
W
U
W
J
J
I
Z .
g0
U
K
U
O
N
W
W
III
W
u)
N
o
J
CW
L
Q
W
Z
Z
W
W
M
W
0
U
SRS ARCHITECTS INC
200 S RANGELINE RD , #226
CARMEL, INDIANA 46032
PHONE: 317-989-6248
E-MAIL : sshaAe@mitschAesi9O.com
CERTIFICATION:
24
q MEET FOR USES E V R ESSLY
PERMITTED IN WRITING.
REV 1:
REV 2:
SHEET NUMBER:
CODE AND LIFE
SAFETY PLAN
0001