Loading...
HomeMy WebLinkAbout[3] 181121 LOT 17 HVAC-M102FAN COIL SCHEDULE ELECTRIC HEAT MARK MANUFACTURER FCU MODEL HEAT KIT MODEL HEATING CAPACITY COOLING ELECTRICAL SPECIFICATIONS ELEC. MCA MOCP (V-Ph-Hz) CIRCUIT CIRCUIT /2 2 70TAL CFM OA CFM STATIC PRESS. NOTES: KW @240 BTUH @240 NOMINAL TONS REFS. FC-1,2 TRANE TEM6AOC6OD60 BAYHTR1522BRKA 1 20 1 66,240 5 1 R410A 240-60-1 1 59/50 1 61 1 1950 1 200 1 .5 1) O SINGLE PHASE CEILING HUNG HORIZONTAL FAN COIL, PROVIDE WITH MANUFACTURERS ELECTRIC HEATING KIT AS SPECIFIED. HEAT PUMP SCHEDULE MARK MANUFACTURER MODEL COOLING HEATING ELECTRICAL SPECIFICATIONS NOMINAL TONS FETE. KBTU SEER BTUH HIGH BTUH LOW IELEC. (V-Ph-Hz) MCA MOCP NOTES: HP-1,2 TRANE 4TWR406OD1000AA 5 R410A 60 14 1 56,000 1 23,600 1 7.7 240-1-60 1 36 1 60 (O O3 O ALL HVAC EQUIPMENT TO BE FIELD LABELED TO IDENTIFY WHICH UNIT OF TF O2 PROVIDE CYCLE PROTECTOR, MOUNTING PAD WITH LEGS, OA THERMOSTAT DIFFUSER, REGISTE TAG DESCRIPTION MFR M S-1 LAY -IN 6" NECK 3 CONE DIFFUSER TRUAIR 2( S-2 LAY-IN6" NECK 4 CONE DIFFUSER TRUAIR 2( R-1 LAYIN BAR FACE OR ALUMINUM EGG CRATE TRUAIR 1-1/2" FSK R-3.5 DUCT WRAP. TYPICAL IN ATTIC CAULK AIR TIGHT TYPICAL REFRIGERATION LINE SET INSTALLED PER MANUFACTURERS \ RECOMMENDATIONS. FAN PROVIDE OPEN SITE TEE WITH COIL UNIT MOISTURE SWITCH ON SECONDARY DRAIN CONNECTION. INTERLOCK WITH ACCU. 3/4" PVC DRAIN LINE ROUTE TO HUB DRAIN. MINIMUM 1/4" PER MANUFACTURERS 2" FILTER RACK FOOT, PROVIDE REMOVABLE CAP WITH MEW 7 FILTER. ON CLEAN OUT TEE FOR LINE 18"MIN. BLOW OUT. LJ PROVIDE LINED SHEET METAL RETURN AIR BOX UNDER FCU. NO SIDE CONNECTIONS ALLOWED. FAN COIL INSTALLATION DETAIL ASCALE: NONE RELEASED FOR CONSTRUCTION NON RATED DRYWALL CEILING. FRESH AIR DUCT WITH MOTORIZED SHUT OFF AND MANUAL BALANCING DAMPER ROUTE TO WALL CAP PER PLANS. LINED RETURN AIR RISER. Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 02/28/19 LEVEL 2 HVAC PLAN SCALE: 1/4"=1'-0" GOODERUM & ASSOCIATES ENGINEERING MEP Engineer AL 874 Cheltenham Way Avon, IN 46123 P: 317.745.5761 F: da%te@5.5761 E: tlave@gnaengineenng.wm GENERAL NOTES: 1. REFERENCE SHEET M-001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. REFENRENCE SHET M-101 FOR FAN COIL MOUNTING DETAILS. KEY NOTES: 1O INSTALL EXHAUST FANS PROVIDE BY OTHERS AND DUCT THROUGH STRUCTURE TO WALL CAPS AS SHOWN. 2O FULLY FINISHED TENANT SPACE. PROVIDE FULLY DUCTED HVAC SYSTEM AS SHOWN. SEE FAN COIL MOUNTING DETAIL ON SHEET M002. COORDINATE CEILING HEIGHT IN ROOM 213 WITH G.C. 3O ROUTE DUCTWORK MAINS SHALL BE ROUTED BETWEEN WOOD ROOF TRUSSES. BRANCHS SHALL BE ROUTED THROUGH WEBS AND THEN STRAIGHT DOWN TO DIFFUSERS IN ACT CEILING BELOW. W n o 77 z V J � m J LU F p U p H w w IiUO w N W dG- r Ul w O w � z � O O � z w ~ O O � w U N U Z � �wr O n v U U w z C � w w v5=z ]2 K O fO uriQ2 �c�Uw SHEET NO LEVEL2 HVAC PLAN DATE I2/9/18 L fi[IYI