HomeMy WebLinkAbout[1] 181121 LOT 17 HVAC-M001CVAAPnl C ABBREVIATIONS THERMOSTAT AFF ABOVE FINISHED FLOOR ACLU AIR COOLED CONDENSING UNIT ROUND MOTORIZED DAMPER AHU AIR HANDLING UNIT AWH ARCHITECTURAL WALL HEATER SHEET METAL DUCT WIDTH BY DEPTH W/D BDD BACK DRAFT DAMPER BOD BOTTOM OF DUCT LINED SHEET METAL DUCT FREE AREA WIDTH _ ppJD BY DEPTH. _ BOB BOTTOM OF BEAM BTUH BRITISH THERMAL UNIT PER HOUR SQUARE SHEET METAL 90 PROVIDE WITH �L JI CFM CUBIC FEET PER MINUTE DOUBLE THICKNESS TURNING VANES. DEG DEGREES FARENHEIT RADIUS SHEET METAL 90, R=1.5'D \ DB DRY BULB �l-J\ 0 ROUNDDUCT EA EACH OR EXHAUST AIR SQUARE SHEET METAL 90 PROVIDE WITH EG EXHAUST GRILLE DOUBLE THICKNESS TURNING VANES. EADB ENTERING AIR DRY BULB EAWB ENTERING AIR WET BULB ROUND HIGH EFFICIENCY BRANCH DUCT EC ELECTRICAL CONTRACTOR TAKE OFF ON ROUND DUCT. ECH ELECTRIC CEILING HEATER ROUND TAP BRANCH DUCT TAKE OFF ON EF EXHAUST FAN ROUND DUCT. EWH ELECTRIC WALL HEATER ESP EXTERNAL STATIC PRESSURE"W.C. HIGH EFFICIENCY BRANCH DUCTTAKE OFF EUH ELECTRIC UNIT HEATER ON RECTANGULAR. F FURNACE FC FAN COIL MANUAL VOLUME DAMPER LOCKING WITH SHAFT �::p PC rry FD FIRE DAMPER ® FD/SD FIRE AND SMOKE DAMPER CENTERED SQUARE TO ROUND TRANSITION FPM FEET PER MINUTE HORIZONTALLY HUNG FC WITH FPVAV FAN POWERED VAV SECONDARY DRAIN PAN FC FT FEET FSK FOIL SCRIM VAPOR BARRIER Iry GC GENERAL CONTRACTOR ELECTRIC WALL HEATER IJ EWH GPM GALLONS PER MINUTE HD HOOD CEILING MOUNTED EXHAUST FAN EF IN INCHES IR INFRARED LAY -IN EXHAUST GRILLE LAT LEAVING AIR TEMPERATURE LAY -IN SUPPLY AIR DIFFUSER ❑® LS LINEAR SLOT DIFFUSER LAY -IN RETURN AIR REGISTER OR GRILLE MAN MANUAL SURFACE MOUNTED SUPPLY AIR DIFFUSER O MBH 1000 BTU SURFACE MOUNTED SUPPLY AIR DIFFUSER MC MECHANICAL CONTRACTOR MARK MCC MOTOR CONTROL CENTER DIFFUSER TAG X_q CFM MFR MANUFACTURER XXX MUA MAKE UP AIR CA OUTSIDE AIR PC PLUMBING CONTRACTOR DHU DEHUMIDIFICATION UNIT PRV PRESSURE RELIEF VALVE PSI POUNDS PER SQUARE INCH PTAC PACKAGED TERMINAL AIR CONDITIONER RA RETURN AIR RJ ROOF JACK RPM REVOLUTIONS PER MINUTE RTU ROOF TOP UNIT SA SUPPLY AIR TCC TEMPERATURE CONTROL CONTRACTOR TSP TOTAL STATIC PRESSURE UON UNLESS OTHERWISE NOTED VAV VARIABLE AIR VOLUME WC WALLCAP WIC WALK IN COOLER WIF WALK IN FREEZER RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 02/28/19 MECHANICAL SPECIFICATIONS GENERAL CONTAIN DAMPERS WHERE SHOWN ON PLANS. LENGTHS FOR INSTALLATION WITHOUT JOINTS, EXCEPT AT EQUIPMENT CONNECTIONS OR ACCESSIBLE 1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE BASE3. INSULATED FLEXIBLE DUCTING SHALL NOT EXCEED 25 LOCATIONS. CONNECTIONS AND WROUGHT -COPPER BID IN STRICT ACCORDANCE WITH DESIGN BASIS FEET. ALL FLEX SHALL BE LISTED FLEXIBLE DUCT, FITTINGS WHERE REQUIRED SHALL BE BRAZED WITH EQUIPMENT AND MATERIALS. PROJECT DOES FLEXIBLE CONNECTORS ARE NOT ACCEPTABLE. FLEXIBLE MINIMUM 8%SIL-FLOS. ENCOURAGE COMPETITIVE PRICING AND ALLOWS FOR DUCT EQUAL TO FLEXIBLE DUCT CLASS I AIR DUCT, B. INSULATION; SUCTION AND ALL DUCTLESS SPLIT OR VRF SUBSTITUTIONS OF EQUAL EQUIPMENT AND MATERIALS DOUBLE LAMINATED POLYESTER FILM ON STEEL WIRE LINES; MINIMUM 1/2" THICK WALL INSULATION SHALL BE AGAINST THE BASIS OF DESIGN. SUBSTITUTE ITEMS WILL REINFORCING, INSULATED WITH SCRIM REINFORCED AFLEXIBLE CLOSED -CELL ELASTOMERIC PIPE BE COMPARED AGAINST DESIGN BASIS DURING METALIZED POLYESTER OUTER FIRE RETARDANT INSULATION, AP ARMAFLEX OR AC ACCOFLEX. ADHESIVE SUBMITTAL PROCESS. ENGINEER RESERVES THE RIGHT JACKET. R4.2 FOR CONDITIONED SPACES AND R-6.0 FOR SHALL BE ARMAFLEX 520,520 BLACK OR 520 BLV TO REJECT SUBSTITUTIONS FOUND NOT TO BE EQUAL TO ANY SPACES OUTSIDE BUILDING THERMAL ENVELOPE. ADHESIVE. THE INSULATION MUST CONFORM TO ASTM ITEMS LISTED IN DESIGN BASIS. FLEX DUCTS SHALL NOT BE RUN THROUGH WALLS OR C534 GRADE 1, TYPE I ARMAFLEX AND BE INSTALLED IN FLOORS. PROVIDE HARD DUCTED SLEEVES AS NEEDED. STRICT ACCORDANCE WITH MANUFACTURERS 2. PRIOR TO PROCUREMENT CONTRACTOR SHALL SUBMIT RECOMMENDATIONS. (3/8"WALL WILL NOT BE TO ARCHITECT FULL SUBMITTALS FOR ALL ENERGY 4. RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED IN ACCEPTED). CONSUMING OR PRODUCING ITEMS AND FOR ALL DUCT ACCORDANCE WITH SMACNA LOW PRESSURE DUCT ACCESSORIES, INSULATION, VAV BOXES, REGISTERS, STANDARDS, +/-1.0" W.C. FROM ASTM A 65NA 653M G-90 C. ALL INSULATION EXPOSED TO OUTDOORS SHALL BE GRILLES, DIFFUSERS AND LOUVERS. SUBMITTALS SHALL COATED GALVANIZED SHEET STEEL. SEAMS SHALL BE EITHER PVC LAGGED OR SHALL BE PAINTED WITH BE DELINEATED WITH TAGS INDICATED ON PRINTS, PITTSBURGH CONSTRUCTION, NO BUTTON PUNCH OR ARMA-FINISH FIR UV PROTECTING PAINT. CONTRACTORS NAME, PROJECT NAME. CLEARLY SNAP LOCK SEAMS ARE ACCEPTABLE. SEAL ALL D. LINES SHALL BE RUN KINK FREE AND GENERALLY INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES TRANSVERSE AND LONGITUDINAL SEAMS WITH WATER CONTINUOUS AND AT 90 DEGREE ANGLES TO AND OPTIONS BEING PROVIDED. SUBMISSIONS SHALL BE BASED DUCT SEALER, SEAL CLASS B. GAUGE AND JOINT STRUCTURE. AVOID JOINTS WHEN POSSIBLE. ALL IN PDF FORMAT. ALL EQUIPMENT AND ITEMS SHALL BE CLASSIFICATIONS ACCEPTABLE ARE AS FOLLOWS, ALL REQUIRED JOINTS SHALL BE MADE IN ACCESSIBLE PER DESIGN BASIS ORAPPROVED EQUAL. ENGINEER SECTION LENGTHS ARE 48" MAXIMUM, REFER TO SMACNA LOCATIONS OR M.C. SHALL PROVIDE ACCESS PANELS AS RESERVES THE RIGHT TO REJECT ANY SUBSTITUTE ITEM. RIGIDITY TABLES FOR GAUGES ON LONGER SECTIONS IF NEEDED. ALL BENDS SHALL BE MADE WITH LONG RADIUS REQUIRED: FITTINGS OR WITH MECHANICAL BENDING TOOL TO 3. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE PROVIDE SMOOTH LONG RADIUS TURNS. SUPPORT ALL ALL REQUIRED ELECTRICAL SUPPORT NEEDED FROM THE <12" 26 GAUGE, FLAT S AND DRIVE PIPING WITHOUT CRUSHING OR DEPRESSING ELECTRICAL CONTRACTOR. ENSURE ALL SUBMITTALS 12"-24" 24 GAUGE, FLAT S AND DRIVE INSULATION. USE REFRIGERATION STYLE CUSH CLAMPS FOR POWERED COMPONENTS AND CONTROLS ARE 25"-34" 22 GAUGE, STANDING S AND FLAT DRIVE MOUNTED TO STRUT, DO NOT LAY PIPING ON PROVIDED AND FULLY COORDINATED WITH ELECTRICAL 34"-40" 22 GAUGE, STANDING SAND STANDING STRUCTURAL BUILDING MEMBERS. SLEEVE ALL CONTRACTORS. DRIVE PENETRATIONS AND SEAL WATER TIGHT. >40" REFER TO SMACNA FOR STANDARDS. E. PRESSURE TEST, TRIPLE EVACUATE AND PREPARE ALL 4. CONTRACTOR SHALL BE RESPONSIBLE TO VISIT THE SITE PIPING IN STRICT ACCORDANCE WITH MANUFACTURERS TO EXAMINE ALL CONDITIONS THAT MAY IN ANY WAY 5. DUCT HANGERS: COMPLY WITH SMACNA'S"HVAC DUCT RECOMMENDATIONS. AFFECT THE EXECUTION OF HIS WORK. HE SHALL ALSO CONSTRUCTION STANDARDS- METAL AND FLEXIBLE," EXAMINE THE DRAWINGS AND SPECIFICATIONS FOR CHAPTER 5,"HANGERS AND SUPPORTS."PROVIDE OTHER BRANCHES OF WORK MAKING REFERENCE TO GALVANIZED MINIMUM 22 GAUGE I"WIDE STRAP TO HANGS. CONDENSTATE PIPING THEM FOR DETAILS OF EXISTING BUILDING CONDITIONS. RECTANGULAR DUCTWORK SMALLER THAN 30" WIDE. NO EXTRAS WILL BE ALLOWED FOR FAILURE TO INCLUDE DUCT HANGERS FOR RECTANGULAR SHEET METAL A PROVIDE TRAPS BUILT FROM INDIVIDUAL FITTINGS ON ALL REQUIRED WORK IN THE BID. CONTRACTOR SHALL DUCTS 30" AND LARGER SHALL BE TRAPEZE STYLE USING ALL EVAPORATOR DRAIN PANS MINIMUM DEPTH 1.5 TIMES GUARANTEE ALL LABOR AND MATERIALS ENTERING INTO UNI-STRUT AND W8" OR 1/2" ROD. PROVIDE GRIPPLE, BLOWER BLOCKED TIGHT STATIC PRESSURE. ALL TRAPS CONTRACT FOR A PERIOD OF ONE (1) YEAR FROM DATE DURODYNE OR EQUAL CABLE HANGERS FOR HANGING SHALL BE CONSTRUCTED WITH PVC 90S OF ACCEPTANCE. ROUND DUCTWORK. SUPPORT ALL HANGERS FROM (MANUFACTURED RUNNING TRAP FITTINGS ARE NOT STRUCTURE PER SMACNA STANDARDS.HANGERS FOR ACCEPTABLE). PROVIDE ALL TRAPS WITH CLEAN OUTS 5. THE DRAWINGS IN THIS SECTION ARE DIAGRAMMATIC SPIRAL DUCTS GREATER THAN 28" IN DIAMETER SHALL AND REMOVABLE CAPS AS NEEDED FOR MAINTAINING AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, BE HUNG WITH ROD AND DUCT CLAMP. FLEXIBLE LINES. LOCATIONS OR CODIFIED REQUIREMENTS. DRAWINGS DUCTING SHALL BE SUPPORTED USING MINIMUM 2"WIDE SHOW GENERAL INTENT OF SYSTEMS. M.C. SHALL NYLON STRAP. ALL INTERVALS ARE PER SMACNA. B. HVAC CONTRACTOR SHALL COORDINATE CONDENSATE PROVIDE AND PAY FOR ALL REQUIRED PERMITS. DISPOSAL POINTS WITH P.C. HVAC CONTRACTOR IS DUCTACCESSORIES RESPONSIBLE FOR PIPING FROM EVAPORATOR COILS TO 6. PRIOR TO WORK COORDINATE ALL OPENINGS AND DISPOSAL POINT. P.C. IS RESPONSIBLE FOR STAND INSTALLATIONS OF DUCT, PIPING, EQUIPMENT, PIPES, FLOOR AND HUB DRAINS AS NEEDED. CONTROLS, DIFFUSERS AND GRILLES WITH G.C. AND 1. COORDINATE WITH ARCHITECTURAL DRAWINGS AND C. MATERIALS: POLYVINYL CHLORIDE DRAIN, WASTE AND OTHER TRADES. PROVIDE INSTALLATIONS WITH PROPER PROVIDE FIRE AND FIRE AND SMOKE DAMPERS AT FIRE VENT PIPE (PVC) SCHEDULE 40 MINIMUM SIZE 3/4" MANUFACTURERS RECOMMENDED CLEARANCES. RATED ASSEMBLY PENETRATIONS IN ACCORDANCE WITH .WRAPPED IN RETURN AIR PLENUMS WITH RA RATED THE INTERNATIONAL BUILDING CODE AND WHERE MATERIAL. 7. UPON COMPLETION OF THE MECHANICAL INSTALLATION, SHOWN ON PLANS. D. PROVIDE CONDENSATE PUMPS AS REQUIRED WITH HIGH DEMONSTRATE TO THE ENGINEER AND THE OWNER'S LEVEL SHUT DOWN SWITCHES INTERLOCKED TO A/C SATISFACTION THAT THE SYSTEMS HAVE BEEN 3. PROVIDE FLASHING MATERIALS AND OR SLEEVES AS UNITS. INSTALLED IN ACCORDANCE WITH THE DRAWINGS, REQUIRED FOR ALL DUCT PENETRATIONS OF NON RATED E. PITCH ALL PIPING MINIMUM }'PER FOOT. SUPPORT SPECIFICATIONS AND APPLICABLE CODES. ELEMENTS.EXPOSED PENETRATIONS SHALL BE FLASHED DEMONSTRATE THE DYNAMIC OPERATION OF EACH WITH SHEET METAL TIGHT TO WALLS. PIPING AT MINIMUM 5'-0"INTERVALS. SECURE FINAL SYSTEM. VERIFY PROPER OPERATION OF EQUIPMENT, CONNECTION AT SEWER WITH MINIMUM I-1/2"AIR GAP FILTERS ARE CLEAN AND COMPONENTS OF THE SYSTEM CONNECTION. ARE INSTALLED AND ADJUSTED IN FULL ACCORDANCE 4. REGISTERS, GRILLES AND DIFFUSERS SHALL BE F. INSULATE ALL PIPING IN RA PLENUMS AND ABOVE HARD WITH MANUFACTURER RECOMMENDATIONS. EQUIVALENT TO SCHEDULED PRODUCTS. CEILINGS WITH MINIMUM 3/8"WALLARMAFLEX INSULATION. B. ALL WORK SHALL BE IN FULL ACCORDANCE WITH 2O14 DUCT INSULATION CHECK TEST AND START UP REQUIREMENTS INDIANA MECHANICAL CODE (2 MECHANICAL MECHANICAL CODE), INDIANA ENERGY CODE (ASHRAE 90.1-2007)PERTINENT STATE, COUNTY, CITY CODES AND 1. ORDINANCES AND INDIANA AMENDMENTS. 9. MECHANICAL CONTRACTOR SHALL ENSURE EMPLOYEES ARE MEETING AND DOCUMENTING ALL OSHA AND JOB SPECIFIC SAFETY REQUIREMENTS AS REQUIRED BY LAW AND BY CONTRACT. PERSONAL PROTECTIVE EQUIPMENT SHALL BE PROVIDED AND UTILIZED AS REQUIRED. MECHANICAL CONTRACTOR SHALL PAY ALL FINES LEVIED BY OSHA FOR FAILURE TO COMPLY WITH OSHA REQUIREMENTS. 10. INSTALL ALL EQUIPMENT, DUCTWORK AND PIPING AS HIGH AS POSSIBLE. PRIOR TO ROUGH -IN COORDINATE 2. ELEVATIONS WITH OTHER TRADES. WHERE VISIBLE, ORIENT PERPENDICULAR AND/OR PARALLEL TO STRUCTURE. EQUIPMENT ALL DUCT INSULATION MATERIALS SHALL HAVE A FLAME 1. SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES AND LOCAL AUTHORITIES HAVING 2 JURISDICTION. DUCT WRAP SHALL BE FIBERGLASS MATERIAL PER ASTM C-411,ASTM C-1104,ASTM C665, ASTM C-1338, ASTM E-84, UL723, NFPA 90A,CAN/ULC S102-1188,ASTM C1290, ASTM C553, ASTM C1136. INSULATION: INSTALL ALL INSULATION IN STRICT ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS IN 3 A TIGHT AND NEAT MANOR. NO SAGGING, FRAYED OR TORN INSULATION WILL BE EXCEPTED. UNLESS OTHERWISE NOTED ON PLANS DUCTWORK SHALL BE INSULATED AS FOLLOWS: SNOA- 1-1/2"FIBERGLASS DUCTWRAP WITH FSK 1. PROVIDE SUBMITTALS TO ELECTRICIAN AS REQUIRED FACING, ➢5 FOR COORDINATION OF ALL ELECTRICAL POWER WIRING. WITH INSTALLED IN STRICT ACCORDANCE WITH IN STRUT ACCORDMUM ANCE INCLUDE WIRING DIAGRAMS AND CABLING MANUFACTURERS REQUIREMENTS. REQUIREMENTS FOR REFERENCE. COORDINATE ALL INTERLOCKS AS NEEDED. PROVIDE SINGLE POINT RA NONE REQUIRED UNLESS NOTED ON PLANSA. CONNECTION KITS AS NEEDED. SA IN UNCONDITIONED OR ATTIC SPACES OUTSIDE THE BUILDING INSULATION 2. INSTALL ALL EQUIPMENT IN FULL ACCORDANCE WITH ENVELOPE; 2"MINIMUM R-6 AS APPLIED FSK MANUFACTURERS RECOMMENDATIONS AND CLEARANCE DUCTWRAP. REQUIREMENTS. PROVIDE ALL REQUIRED MOUNTING OR EA- NONE REQUIRED UNLESS NOTED ON PLANS. HOUSEKEEPING PADS. G.C. SHALL PROVIDE LEVEL GRADE FOR EXTERIOR MOUNTED EQUIPMENT. M.C. PIPING SHALL PROVIDE ALL HOISTING AND RIGGING NEEDED TO 5 SET ALL HVAC EQUIPMENT. 1. PIPING SLEEVES; INTERIOR OR EXTERIOR ABOVE GRADE; DUCTWORK GALVANIZED -STEEL -PIPE SLEEVES OR PVC -PIPE SLEEVES. VERIFY, WITH FIRE AUTHORITIES HAVING JURISDICTION, THAT PVC MATERIALS ARE ALLOWED FOR 1. CONCEALED ROUND DUCTWORK SHALL BE SLEEVES. BELOW GRADE; ALL; MECHANICAL CONSTRUCTED PER SMACNA LOW PRESSURE GALVANIZED -STEEL PIPE SLEEVE SYSTEM LIKE STANDARDS I" PRESSURE CLASS, TMAXIMUM JOINT LINK -SEAL ALL SLEEVES SHALL BE FIRE STOPPED OR LENGTHS, SEAL CLASS B LONGITUDINAL SEAM SNAP . CAULKED. EXTERIOR SLEEVES SHALL PROVIDE LOCK PIPE AND ADJUSTABLE FITTINGS. WATER/AIR TIGHT PENETRATION SYSTEM. 2. PROVIDE MANUAL BALANCING DAMPERS FOR ALL SUPPLY AIR RUNS. ROUND DAMPERS SHALL BE SECURED2. REFRIGERATION PIPING; ON BOTH SIDES OF DUCTAND SHALL CONTAIN LOCKING HANDLE. DO NOT INSTALL DAMPERS IN NON ACCESSIBLE LOCATIONS. PROVIDE INTEGRAL DAMPERS WITH A. SYSTEMS 5 TONS OR LESS; MANUFACTURED DIFFUSER IN NECK IF NO ACCESSIBLE LOCATION IS REFRIGERANT LINE SETS: ANNEALED -COPPER SUCTION POSSIBLE. ALL SUPPLY AIR RUNS SHALL HAVE MEANS OF AND LIQUID LINES FACTORYCLEANED, DRIED, BALANCE. RETURN AND EXHAUSTAIR RUNS SHALL PRESSURIZED WITH NITROGEN, SEALED, AND WITH SUCTION LINE INSULATED. PROVIDE IN STANDARD ALL HVAC EQUIPMENT INSTALLATIONS SHALL BE VERIFIED AND STARTED UP PER MANUFACTURERS RECOMMENDATIONS. VERIFY ALL MODES OF OPERATION. CONFIGURE ALL CONTROLS AND PROGRAM OCCUPANCIES PER OWNER PROVIDED SCHEDULES. LABEL ALL MAJOR PIECES OF EQUIPMENT WITH LAMACOID PLASTIC, BLACK WITH WHITE LETTERS. SIZE TO BE CONSISTENT WITH EQUIPMENT BEING LABELED. LENGTH AND WIDTH VARY FOR REQUIRED LABEL CONTENT. THERMOSTAT AND SENSOR LABELS SHALL BE ADJUSTED TO PROVIDE ESTHETIC APPEARANCE. PROVIDE AIR BALANCE BY CONTRACTOR. CONTRACTOR SHALL BALANCE SUPPLY, RETURN, OUTSIDE, RELIEF AND EXHAUST AIR SYSTEMS IN ACCORDANCE WITH CURRENT SMACNA, NEEB OR AABC STANDARDS TO DESIGN VALUES AND PROVIDE WRITTEN REPORT TO ARCHITECT. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL DEVICES, DRIVES, SHEAVES, MOTOR CHANGES AND REWORK AS REQUIRED TO MEET DESIGN REQUIREMENTS. TEMPERATURE CONTROL WORK SHALL BE THE RESPONSIBILITY OF THE HVAC CONTRACTOR. PROVIDE ALL COMPONENTS INCLUDING T/S, T/S WIRE (PLENUM RATED IN RA PLENUMS), SWITCHES, ACTUATORS ETC. AS REQUIRED FOR A COMPLETE SYSTEM. PRIOR TO ROUGH -IN COORDINATE FINAL LOCATION FOR ALL CONTROLS WITH OWNERS REPRESENTATIVE. CLOSE OUT: PROVIDE MANUFACTURERS OPERATION AND MAINTENANCE MANUALS, AIR BALANCE REPORTAND AS BUILT DRAWINGS. PROVIDE (1) TRAINING SESSION TO OWNER SELECTED PERSONNEL AS REQUESTED AND PROVIDE WARRANTY INFORMATION FOR ALL MANUFACTURERS WARRANTED EQUIPMENT. GOODERUM & ASSOCIATES ENGINEERING MEP Engineer 874 7.606. 161 Way Avon, IN 46123 P: 317.746.6761 F: 31T.T45.5T61 E: dave@gnaengineenng.com Cn LLU IL LL M U S z � V Z LL W LU i F� z0 U W z LH W wU UWJ4 Y oUON LLB w W r r O � W c� � O O � z w ~ O O � w U N U z r �wr U U w z C � w w v5=z ]2 K O fO uriQ2 �c�Uw rZ V x 0 J as w a�� F _ u nw ~ Su >�ia � o W 0 J w w 3 V/ SHEET NO HVAC ABBREVIATIONS, SYMBOLS,& SPECIFICATIONS DATE I2/9/18 M001