HomeMy WebLinkAbout19020081 Building PlansMECHANICAL & ELECTRICAL NOTES I. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO BASIC DESIGN -BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE DESIGN -BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL, ELECTRICAL AND PLUMBING DESIGN -BUILD CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN -BUILD CONTRACTOR AND MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM DESIGN -BUILD CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS, 2. MECHANICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED, ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED: MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES, 3, VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED, DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING OWNER/LANDLORD. 4. RELOCATE AIR -SUPPLY DIFFUSERS AND RETURN -AIR GRILLES AS REQUIRED. PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. LOCATION OF DIFFUSERS SHOWN ON PLAN IS FOR REFERENCE ONLY. CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY CODE. 5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR OTHER CONFLICTS. PROVIDE BALANCE REPORTS TO OWNER UPON COMPLETION OF PROJECT, 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS, PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED. 9. ALL ELECTRICAL OUTLETS WITHIN 6-0 OF OF WATER ARE TO BE G.F.C.I. 10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE, 11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCH PLATES TO MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE. 12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN. REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM WORKSTATION WHIP TO JUNCTION BOX, THE FURNITURE VENDOR IS TO BE RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS. 13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL CONDUITS TO JUNCTION BOXES. 14. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. 15. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A. REQUIREMENTS AND ARE CONSISTENT THROUGHOUT, 16. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE(1) GANG BOX WITH SINGLE COVER PLATE. 17. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOW NLIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXT SIGNS UNLESS OTHERWISE NOTED. 18. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER IT AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE, FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 19. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPAI. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION, FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 20, COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT -INSTALLED ITEMS (I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS). 21, IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING SPACES. CONSULT WITH LANDLORD. ALL LAMPS ARE TO BE MATCHING IN CRI AND MANUFACTURER. 22. NEW AND EXISTING PLUMBING LINES IN CEILING ARE TO TO BE INSULATED. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City d Camel �NI��V'�TI*r41rPML DATE: \ 03/04/19 GENERAL PROJECT NOTES I. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE. 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES, CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK. 3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. 4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE. 5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SC HOYT DESIGN, INC. 6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON-STE ACTIVITIES: SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. 7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING HOLIDAYS, LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. 8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE, THE OWNER,TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. 9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION. 10. SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES. 11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT. 12, THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS, 13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK, DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS ® 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH SIDE, 14. CONTACTTHE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. Q.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN(. 15. SCHOTT DESIGN,INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECTSTE, 16. PROVIDE FIRE -TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC. FINISH NOTES I. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. 2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS, CORNER BEADS, ETC.) 3. REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM DESIRED COLOR PRIOR TO PURCHASING NEW. 4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. 5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN Q.E. WHERE VCT MEETS CARPET). 6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. 7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED. B. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 9. SUBMIT FINISH SAMPLE OF MILLWORK(STAINED OR PAINTED AS SPECIFIED) TO SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK, 10. REFERENCE INTERIOR ELEVATION& SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION. 11. ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT. 12. ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. 17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. 18, EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 19, ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. 20. ALL DETAILS,MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER, 21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. 22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED. 23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED, PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. 25. ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS OR INSTRUCTIONS. 26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCE S WORK & DO NOT LEAK, 27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 29. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD. 30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. 31, FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE -RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. 32. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 33. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN INDICATOR OF BUILDING TYPE, BUILDING TYPE LISTED ON LI OO IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION. 34. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES, ADJUST DOORS AND FRAMES AS REQUIRED. FIRE PROTECTION NOTES weleal I. FIRE EXTINGUISHERS: CONTRACTORTO ENSURE ALL NEWAND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING, MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. DEMOLITION NOTES I. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS. 2. NO STRUCTURAL OR LOAD -BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD -BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR AROUND STRUCTURAL MEMBERS, THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OF WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS. 4. WHERE EQUIPMENT,FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES. NOTE THATSOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION. 6. REMOVE ALL CARPEL VINYL BASE,VCT, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS, REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN. 7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED. SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION. S. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID INSTRUCTIONS. 9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT. 10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION( REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS,AND PLTC CABLES. REFER TO SECTION 300.21. 11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFETY REGULATIONS OR PROCEDURES, TAKE BACK TO SOURCE IF NOT BEING REUSED. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN AS -BUILT SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING OW NER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS, DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY. MILL/CASEWORK NOTES I. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GENERAL CONTRACT. 2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION. 4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS -BUILT CONDITIONS IN FIELD. REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR, MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING 50 WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. 5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. 6. REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4' BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED, 2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE 7. EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED OTHERWISE. DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR IF PVC EDGING IS BEING PROPOSED BY FABRICATOR FOR EDGES OF CABINETS AND RENOVATION OF THE FIRE SPRINKLER SYSTEM. DRAWERS, FABRICATOR MUST PROVIDE SAMPLE OF COLOR MATCHING SPECIFIED PLASTIC LAMINATE FOR APPROVAL. 3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES 8. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FI RE (CUSTOM PLASTIC LAMINATE OR PRE -MANUFACTURED STOCK CABINETRY). SPRINKLER/FIRE SUPPRESSION SYSTEMS, 9. TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, CABINETRY WHERE SPECIFIED, ALL WOOD BLOCKING TO BE FIRE RATED, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT, 5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. 6, FIRE STOP ANY EXISTING DECK PENETRATIONS. DOCUMENT APPROVAL TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS. TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN -OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANpCLIENT, THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. T. .I..,,i .w., ..,w.. me O +fie .... Carmel ,.... .... ^ee,u ➢ n „ram. P nTr NOMM1 3 t6eMmmr lrtel a, ,,....,, - WooalamOwmryGlU4 .i,.,,1 ® ,,,.��. - aim.rnoro�m ®,�,- lock Golf Nub a 3 e 9 a Qswnys Go' .. rai,rvr- e rn9WOA x-un me a oli MaIImK¢ynon¢Oam i'd.ol VICINITY MAP KEY PLAN - I FLOOR NOT TO SCALE INDEX OF DRAWINGS TIII COVER SHEET AND GENERAL PROJECT NOTES LI00 LIFE SAFETY PLAN DIII DEMOLITION PLAN AIII ARCHITECTURAL FLOOR PLAN AI21 REFLECTED CEILING PLAN A131 FINSH PLAN A211 DOOR SCHEDULE/ INTERIOR DETAILS El II ELECTRICAL PLAN NOT TO SCALE H THIS Di AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. W ~ J LLJ Q 5 Z --Q LU - U Z Y ~ I_ Q Q Z �Q 2 Zz o `L - L`LJ L Ly z C C all ISSUE wall DALE DESCRIPTION 12.21.18 PERMIT SET 01.15.19 CONSTRUCTION SET REVISIONS ARK DATE I DB DESCRIPTION 01.15.19 CRB CHECKSET UPDATE 01.23.19 SLF REVISION2 01.30.19 AS REVISION 3 PROJECT NUMBER 2018.467 PROJ. MGR DRAWN BY AS SLF 4TH FLOOR COVER SHEET AND GENERAL NOTES T111 2 3 4 5 6 7 6 9 10 11 12 13 14 15 16 CODE SUMMARY SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY OFFICE SPACE PREVIOUS USE OF SPACE BUSINESS) OCCUPANCY CLASSIFICATION BUSINESS) CHANGE OF OCCUPANCY CLASS? NO TOTAL BUILDING AREA VARIES SF/FLOOR X 1 8STORIES - 214,546 SF TOTAL PROJECT AREA 5793 SF SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD OCCUPANCY CALCULATIONS NUMBER OF EXITS GEN.OFFICE 5793 SF 100 58 TOTAL OCCUPANTS IN PROJECT AREA 58 REQUIRED:2 PROVIDED:2 SPRINKLER SYSTEM (YES/NO) YES- EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTALAREA ON THE FLOOR 22,478 SF ACCESSORYAREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO BUILDING CONSTRUCTION TYPE 1-9 LEGEND Ep EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT. BUILDING STAIR LOCATION �I® FIRE EXTINGUISHER EXIT SIGN - LED EDGE LIT q® ® EMERGENCY LIGHT — — — TRAVEL DISTANCE NIGHT LIGHT/EMERGENCY LIGHTING Nut (NIGHT LIGHTS ARE HOOKED UP TO BUILDINGS EMERGENCY GENERATOR) RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes �TG'UB*S41WML DATE: \ 03/04/19 ® AREA NOT IN CONTRACT ❑ AREA OF WORK LIFE SAFETY NOTES I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. ELECTRICIAN TO RELOCATE EXISTING. ANY NEW FIXTURES TO BE ADDED BY OWNER'S LIFE SAFETY VENDOR ONLY. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING, MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. FIRE EXTINGUISHERS PROVIDED BY TENANT. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING GENERAL NOTES LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. LIFE SAFETY PLAN 0 4' 8' 16' H )ESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLFCTUAL PROPERTY OFTT T TOO DESIGN, INC.. AND ARE NOT TO BE 15E OR REPRODUCED IN WHOLE. OR I C PARE TWITHOUT THE OF SCHOTT WRITTEN CONSENT OF SCHOTT DESIGN. CV C) LO iiz v- W J ~ WC = Q -Q V=U Z Q Q Z ZZo Li a L`LJ L z CIUI C E REVISIONS MAR DATE DB DESCRIPTION 01.15.19 CRB %ECKSET UPDATI 01.23.19 1 SIR 1 REVISION2 01,30.19 1 AS I REVISION 3 PROJECT NUMBER 2018.467 PROD. MGR DRAWN BY AS SLF 4TH FLOOR LIFE SAFETY L 100 ARCHITECTURAL LEGEND WALL THICKNESS NEW CONSTRUCTION EXISTING TO REMAIN wwwwiim WALL WALL o PARTIAL HEIGHT WALL O PARTIAL HEIGHT WALL �o WINDOW/SIDELIGHT a—¢ WINDOW/SIDELIGHT METALSTUD DOORANDFRAME (SEE DOOR SCHEDULE) DOOR AND FRAME 77 NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE W1 UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT/ GREEN BOARD AS REQUIRED IN RESTROOM Al SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. 0 WALL WITH INSULATION 35/"METALSTUDS AT 16" O.C.; ONE LAYER OF 5/a" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2-0 EACH EACH SIDE OF WALL ABOVE CEILING 9 STANDARD WALL 35/8" METAL STUDS AT 16" O.C.; ONE LAYER OF z% TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING DEMISING WALL TO DECK WITH INSULATION 3SV" METAL STUDS AT 16" O.C.: ONE LAYER OF %" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK: FIBERGLASS SOUND BATT INSULATION INSIDE WALL H PARTIAL HEIGHT WALL 35% MRALSTUDS Ai 16" O.C.; ONE LAYER OF 5%' TYPE "X" GYPSUM BOARD EACH SIDE; SEE ELEVATION FOR WALL HEIGHT; PROVIDE I"STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED: RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City Bf Camel DATE: 03/04/19 EXISTING WIN MULLION PRE -FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT n WALL AT MULLION DETAIL A I I I NOT TO SCALE GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT 2, REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR W ALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. PLAN NOTES A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. A02 PROVIDE PLYWOOD PHONE BOARD, 4'XB>J, PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET A03 TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE PROVIDED BY TENANT AND INSTALLED ACCORDING TO NFPA 10. PROVIDE COAT ROD AND SHELF AT THIS LOCATION; SEE DETAIL A04 2/A211 FOR MORE DETAILS. PROVIDE (2) BRUSHED CHROME DOUBLE COAT HOOKS AT MAXIMUM 48" A.F.F. FOR ADA COMPLIANCE AT THIS LOCATION. PROVIDE NEW PLASTIC LAMINATE IPL21 ISLAND COUNTER ON A08 PARTIAL HEIGHT WALL AS SHOWN. ON SOUTHEAST SIDE OF ISLAND, COUNTER TO BE AT 42" AFF AND OVERHANG PARTIAL HEIGHT WALL TO ALLOW FOR SEATING. SEE ELEVATION 4/A211 FOR BASE CABINETS ON NORTHWEST SIDE OF ISLAND. SUPPORT COUNTER AS REQUIRED WITH CENTERLINE BRACKET'S FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR AOB TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. AO] ALIGN FINISHED WALL SURFACES WITH EDGE OF CONCRETE COLUMN. COLUMN TO REMAIN UNFINISHED; CLEAN AS MUCH AS POSSIBLE. A08 COLUMN TO REMAIN UNFINISHED; CLEAN AS MUCH AS POSSIBLE. P01 PROVIDE POTABLEHOT AND COLDWATER ANDSANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PROVIDE A 6GALLON WATER HEATER FOR SINK. REFER TO ANDLO D FOR XACi LOCATICN. 0 AREA NOT IN CONTRACT ARCHITECTURAL PLAN ❑ AREA OF WORK 0 2' 4' 8' 16' ®N THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC.. AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH OTT DESIGN. N Q LO will W J ~ W Z --Q LU Z�cn N_ Q < 7 2Z�o aaa� Z ni LL = W 0 5 5w z SSU E DATE DESCRIPTION 12.21.18 PERMITSET 01.15.19 CONSTRUCTION SET EVISONS MARK DATE DB DESCRIPTION 01.15.19 CRB CHECKSET UPDATE 01.23.19 SEE REVISE ON2 01.30.19 AS REVISION 3 PROJECT NUMBER 2018.467 PROD. MGR DRAWN BY AS SLF 4TH FLOOR ARCHITECTURAL FLOOR PLAN A111 LEGEND NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 2'x4', LIGHT FIXTURE, 2'x4', BUILDING STANDARD LED FLUORESCENT, PARABOLIC LIGHT FIXTURE, 2'x2', LIGHT FIXTURE, 2'x2', BUILDING STANDARD LED FLUORESCENT. PARABOLIC RECESSED FIGHT K( RECESSED LIGHT FIXTURE FIXTURE 40 DIRECTIONAL RECESSED LIGHT FIXTURE NL NIGHT LIGHT 3 EXIT LIGHT FIXTURE ® EXIT LIGHT FIXTURE EMERGENCY LIGHT EMERGENCY LIGHT FIXTURE FIXTURE INN LIGHT SWITCH LIGHT SWITCH $N3 LIGHT SWITCH, SWAY Y3 LIGHT SWITCH, SWAY $ND LIGHT SWITCH. DIMMER $D LIGHT SWITCH. DIMMER $NP SWITCH, PROJECTOR SCREEN 'PP SWITCH. PROJECTOR SCREEN $NG SWITCH, GARBAGE DISPOSAL $G SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) $NE SWITCH, EXHAUST FAN $G SWITCH, EXHAUST FAN i — LIGHTCIRCUR LIGHTCIRCUR CEILING GRID, i- CEILING GRID, SUSPENDED, Zx4' _yr_ SUSPENDED, Zx4' CEILING GRID, CEILING GRID, SUSPENDED, Z& _ SUSPENDED, Z& 1 CEILING GRID, SUSPENDED, GRID ES TO COMPLETE I CEILING GRID. GRID i i SUSPENDED, 4'x4' I I GYPSUM BOARD GYPSUM BOARD CEILING CEILING 1-1 EXPOSED TO DECK RELOCATED DIFFUSER, LAY IN, Z& RELOCATED ® DIFFUSER, LAY IN, IX4' RELOCATED DIFFUSER, LAY IN, 4'k4' ® EXHAUST FAN, 2 x2' ® EXISTING DIFFUSER, LAYLI 2'x2' ® EXISTING DIFFUSER, LAY- IN, IX4' EXISTING DIFFUSER, LAY -IN, m 4'M4 Fol EXISTING EXHAUST FAN, ZX2 NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NONEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELOCATE DIFFUSERS & GENERAL NOTES PROVIDE NEW BUILDING STANDARD 2X2CEILING GRID AND TILE INSTALLED AS HIGH AS POSSIBLE FOR UNIFORM HEIGHT ON ENTIRE 4TH FLOOR. CONFIRM EXACT SPECIFICATIONS WITH LANDLORD. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS ATTHEIR EXPENSE, 3. LAYOUT SHOWN IS INTENDED TO MEETASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50%OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 4. UNLESS NOTED OTHERWISE, ALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, 5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTISWITCHPLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS, ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES, nMECHANICAL DIFFUSER RELOCATION RELEASED FOR CONSTRUCTION `REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION Subject to compliance with all regulations of State and Local Codes City of Camel /� �ja GsUDaS41WML_ DATE: \ 03/04/19 MECHANICAL NOTES I. M EC HA N ICA L WO R K IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCDNORK OR EQUIPMENT IS BEING ADDED: MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE IN DIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. 2. HVAC LAYOUT TO BE APPROVED PRIOR TO WORK BEING COMPLETED. FILTERS MUST BE CHANGED AT CLOSE OF PROJECT AND ALL THERMOSTATS MUST BE CALIBRATED AND AIR BALANCED. PROVIDE REPORT TO OWNER. PLAN NOTES R01 CONTROL ENTRY, CORRIDOR, BREAK AND OPEN OFFICE LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. 4'X4' CEILING GRID TO BE INSTALLED THROUGHOUT ENTIRE 4TH R02 FLOOR. COORDINATE EXACT REQUIREMENTS WITH LANDLORD. ® AREA NOT IN CONTRACT REFLECTED CEILING PLAN ❑ AREA OF WORK 0 2 4 B 6' N THIS DRAWING. AND THE IDEAS. DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTF DESIGN. INC.. AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART. WITHOUT THE WRITTEN CONSENT OF SCH 07 DESIGN. CV 0 Nq Z W J ~ LLJ Z --Q Z i V) 2 Z o_ II• aaaaaa� Zz / ll/ Li Q lu- L SIuI z L SSUE DATE DESCRIPTION 12.21.18 PERMITSET 01.15.19 CONSTRUCTION SET EVISONS ARK DATE I DB IDESCRIPTION 01,15.19 CRB CHECKSET UPDATE 01.23.19 SELF REVISION2 01.30.19 AS REVISIONS PROJECT NUMBER 2018.467 PROD. MGR DRAWN BY AS SLF 4TH FLOOR REFLECTED CEILING PLAN JAl21 LEGEND FLOOR COVERINGS CARPET MFG: SHAW CONTRACT DPTt TYPE: BROADLOOM PATTERN: TONE5AI52 COLOR: METAL GREY 51585 1VT1 MFG: MANNINGTON COMMERCIAL SIZE: 3" X 36' PATTERN: AMTICO WOOD COLOR: QUILL GESSO NOTE: PROVIDE SKIMCOAT OF ARDEX LEVELING LATEX AS NEEDED FOR SMOOTH SUBFLOOR THAT WILL NOT ALLOW FOR TELEGRAPHING OF IMPERFECTIONS IN THE FLOOR INSTALL: STAGGER PLANKS. LENGTH OF PLANKS TO RUN IN DIRECTION OF ARROWS ON PLAN. WALL BASE VBt MFG: JOHNSONITE TYPE: 4" VINYL COVEY' GAUGE COLOR: 63 BURNT UMBER PAINT / WALLCOVERING Rt MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SW7056 RESERVED WHITE FINISH: EGGSHELL O MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SW9163 TI N LIZZIE FINISH: EGGSHELL PT3 MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SW2839 ROYCROFT COPPER RED FINISH: EGGSHELL PLASTIC LAMINATE / SOLID SURFACE PLi MFG: NEVAMAR ICOUNTERTOPI COLOR: SMOKY WHITE #S70D1 ®MFG: WILSONARi ICABINETRYI COLOR: STH AVE. ELM #7966 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City d Camel �VT�LJ'�B*S41WML_ DATE: \ 03/04/19 GENERAL NOTES PLAN NOTES I. REFER TO LEGEND FOR ALL ACCENTOPECIALTY PAINT OR PROV I DE JOHNSON UE SLIM LINES LT-63-F PROFILE TRANSITION STRIP F01 WALLCOVERING THAT REQUIRES LEVEL 4OR LEVEL 5 DRYWALL AT FLOORING TRANSITION; COLOR: BURNT UMBER. CONTRACTOR FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. MUST PROVIDE LEVELING LATEX SUCH THAT HEIGHTS OF MATERIALS ARE APPROPRIATE FOR USE WITH SPECIFIED PROFILE TRANSITION. BE AWARE TRANSITION STRIP MUST BE ORDERED IN A TIMELY MANNER AS IT IS NOT ALWAYS IMMEDIATELY AVAILABLE. NO FINISHED FLOORING IN THIS ROOM UNLESS OTHERWISE NOTED; F02 PROVIDE APPROPRIATE TRANSITION STRIP WITH CARPET. DPTt STG. Vlit �1 AREA NOT IN CONTRACT AREA OF WORK FINISH PLAN 0 24' 8' 16' %M11611111010I THIS DRAWING, ANDTHE IDEAS, DESIGNS AND CONCEPTS CON INED HEREIN. ARE THE EXCLUSIVE IMELLECTUAL PROPERTY OF SCH07 DESIGN, INC.. AND ARE NOTTO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. CV Q U W J ~ W Z --Q LUVY� Z V) _ �QQ7 2Zzo � Z ni Li = III J LU z C SSUE DATE DESCRIPTION 12.21.18 PERMITSET 01.15.19 CONSTRUCTION SET EVISONS ARK DATE I DB DESCRIPTION 01.15.19 CRIB CHECKSETUPDATI 01.23.19 SLF REVISION2 01.30.19 AS REVISION3 NUMBER 2018.467 PROJ. MGR DRAWN BY AS SLF 4TH FLOOR FINISH PLAN (>N (Al 31 o TO IXLSTNG STACK Kx P s7CENTERSUPPORTRACKET. .)...,' ucK UEwnrvesHEv cLG. difv_�E i i pp. MCI END) I ) �IXIS( INK yW. E: WHERESPAN RI( EEW 4'L'. EA FF. ) NOTE: REFERW FLOORPLAN AND CASEWORK ELEVATIONS MR SINK LOCATIONS.E FROVOE(So PUSHT DOUBLE OOFSAT TIIOOUATUAKIUIx,.FFNEnon MrIIANCE. —+ TO 4'W. BUILDING DRNN RISER DIAGRAM DETAIL (2)COAT/ROD A211 TYPICAL ALL SINGLE LOCATIONS, NOT TO SCALE 7T2" 0 3" 6" 1' 2' 3'3" 33 33 33 33 1'7 WALLCA&NEE (SEE CASEWORK NOTE I — SINGLE BOWL SINK: 18 GAUGE ----�I KOHLER TOCCATA (OR EQUAL) REFRIG. BY WITH MOEN AWN FAUCET LID TENANT II #7se5SRS (OR EQUAL IF— —1I - 24" DEEP PLASTIC LAMINATEIrILO II II (PI21 COUNTERTOP WRH 4" HIGH BACK "L. ' MICROWAVE BOX ! j DISHWASHER �\ — _ BY TENANT: .- `� _ GEMODEL# BASECARNETS �� [SEE CASEWORK NOTE I I DT22GGLW L____—.1 3-0 IP) 26 33' 33 2UU 1-3 1-7 n ELEVATION - BREAK 418 A211 0 1' 2' 4' J•J, I 3 3" 1'7 24" DEEP PLASTIC LAMINATE (PL21 COUMERIOR SUPPORT COUNTER AS REQUIRED WITH CENTERLINE BRACKETS FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCINNG AND DRYWALL INSTALLED OVER VERTICALSUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED, COUNTER TO OVERHANG ON OPPOSITE SIDE OF BASE CABINETS TO ALLOW MR STOOL SEATING. PARTIAL HEIGHT WALL ON OPPOSITE SIDE OF BASE CANNED TO BE PAINTED DRYWALL FlNISH WITH BASE AS SCHEDULED RPDEEP PLASTIC LAMINATE PL21 COUNTERTOP WITH FULL HEIGHBACKSPLASH RASE CABINETS (SEE CASEWORK NOTE 1) n ELEVATION - BREAK 418 ISLAND 0 1' 2' 4 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes aT, City of Camel IVT�L7tBN�SDAAK DATE: \ 03/04/19 CASEWORK NOTES GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF BASE CABINET PRIOR TO ORDERING, PROVIDE A.W.I. CUSTOM GRADE, FLUSH -OVERLAY CABINETS. FABRICATE WITH PLASTIC LAMINATE (PLII COVERED M.D.O. BOARD WITH MOCKETT DP3B4 PULLS, FINISH: SATIN CHROME, COORDINATE WITH ELEVATIONS FOR QUANTITIES. -AT BREAK ROOM PROVIDE: 24" DEEP COUNTERTOPS 23" DEEP BASE CABINETS I IY" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS - 4" BASE AT CABINETS TO BE VINYL BASE AS SPECIFIED, UNLESS NOTED OTHERWISE. DOOR SCHEDULE # DIMENSIONS I DOOR FRAME HARDWARE REM. 01 3'-MX8'-0k TYPE D3 MATERIAL FINISH GM TYPE I MATERIAL I FINISH ELCR, 02 4 BIRCH VNR. AL MATONE 03 3'-0'k8'-O'k13/" D2 ID CORE BRLCH VNR. TBD FI TIMELY ALUMATONE PS 04 3'-0'k8'-O'k13/" D2 ID CORE BRLCH VNR. TBD F2 TIMELY ALUMATONE PS 05 3'-0'k8'-O'k13/" D2 SOLID g RCH VNR. E TBD F2 TIMELY ALUMATONE PS Ob 3'-0'k8'-O'k13/" D2 SOLID CORE BIRCH VNR. TBD F2 TIMELY ALUMATONE PS 07 3'-0'k8'-O'k13%' D2 SOLID CORE BIRCH VNR. TBD F2 TIMELY ALUMATONE S 08 3'-0'k8'-O'k13%' DI SOLID LCH CORE TBD F2 TIMELY ALUMATON OL 09 3'-0'k8'-O'k13/" DI BRLCH COID RE TBD F2 TIMELY ALUMATO OL 10 3'-0'k8'-O'k13/" DI BRLCH COID RE TBD F2 TIMELY ALUMATON OL 11 3'-0'k8'-O'k13%' DI BRLCH COID RE TBD F2 TIMELY ALUMATON OL 12 3'-0'k8'-O'k13%' DI BRLCH COID RE TBD F2 TIMELY ALUMATO OL 13 3'-0'k8'-O'k13/" DI SO CR CORE TBD I F2 TIMELY ALUMATO OL 14 3'-0'k8'-O'k13/" D1 ID CORE BRLCH VNR. TBD F2 TIMELY ALUMATON OL 15 3'-0'k8'-O'k13%' D1 BRLCH COID RE TBD F2 TIMELY AWMATO OL Ib 3'-0'k8'-O'k13/" SOLID CORE BIRCH VNR. TBD FI TIMELY ALUMATONE L, 17 3'-0'k8'-O'k13%' D2 OLD CORE BIRCH VNR. TBD FI TIMELY ALUMATONE CR, ES, SL, CL RI 18 3'-0'k8'-O'k13%' SOLID CORE BIRCH R. TBD FI TIMELY ALUMATONE P L 19 3'-0'k8'-O'k13W" D1 BRLCH v�RE TBD FI TIMELY ALUMATONE OL DOOR/FRAME TYPES D1 D2 VERHEAOC 3'-0" 3'-0" 0 BE DOi .75 STAINLES \ SELL TOP RAI TOP ANDBBOI PPP PHNIOIA IYL' TEMPERED GLASS ROVIDE ONE PULL ON EACH SIDE OF DOOR (TOTAL COUNT 2). PULL TO BE CR LAURENCE DLLPA48BS D3 m 3'4' F1 F2 F3 REMARKS RI. SEE DOOR TYPE D3 FOR ALL REQUIRED HARDWARE AT HER CU LITE ENTRY DOOR SYSTEM, PROVIDE DRYWALL WRAPPED OPENING AT rHls LocgnoN. p R2. LANDLORD TO PROVIDE 24-VOLT ELECTRONIC STRIKE WITH WIRING HARNESS. HARDWARE LEGEND CL CLOSER CH COAT HOOK CR CARD READER BY TENANT (N.I.C.) DB DEADBOLT DL DUMMY LEVER I ES ELECTRICSTRIKE BY CONTRACTOR (SPEC PROVIDED BYTENANTIx KP KICK PLATE KS KICK STOP OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSHI PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES DOOR/FRAME NOTES I. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. PRE -MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. PROVIDE NEW BUILDING STANDARD HARDWARE, FOR NEW DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: 7'-0' Hi, TO HAVE 3 HINGES GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES • FINISH TO MATCH HARDWARE SET 8. PROVIDE (I I SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. THIS DRAWING, AND THE IDEAS, )ESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOTTO BE 1SED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. CV O 10 , ^ LO � � z ~ Wmi J W I N Z -Q ZY V) Q Q Z Z Q C) Li L`LJ L LKi W z SSUE mi DATE DESCRIPTION 12.21.18 PERMITSET 01.15.19 CONSTRUCTIONSET EVISONS ARK DATE I DB DESCRIPTION 01.15.19 CRB CHECKSETUPDATI 01.23.19 SUE REVISION 2 01.30.19 AS REVISION 3 PROJECT NUMBER 2018.467 f'7Zi71ALLC R ;H a 7 7\577�1a AS SLF 4TH FLOOR DOOR SCHEDULE INTERIOR DETAILS A2 1 I LEGEND GENERAL NOTES PLAN NOTES NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, DUPLEX POWER OUTLET, DUPLEX 'N POWER OUTLET, POWER OUTLET, QUADRUPLEX QUADRUPLEX 8 JUNCTION BOX QJ JUNCTION BOX OCEILING MOUNTED CEILING MOUNTED JUNCTION BOX JUNCTION BOX ® BOX, BLANK COVER PLATE ® BOX, BLANK COVER PLATE ® BOX, OPEN QO BOX, OPEN p POWER POLE FOR P POWER AND DATA POLE ■ ELECTRICAL AND DATA. D PROVIDE JUNCTION BOX ABOVE CEILING. FLOOR BOX WITH POWER FLOOR BOX WITH POWER � 44 AND DATA, FLUSH E AND DATA, FLUSH MOUNTED MOUNTED FLOOR BOX WITH FLOOR BOX WITH ® JUNCTION BOX AND J 171 JUNCTION BOX AND DATA, FLUSH MOUNTED DATA, FLUSH MOUNTED DATA/COMMUNICATION DATA/COMMUNICATION 14 OUTLET (PROVIDE BOX IQ AND PULL STRING ONLY( OUTLET DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42' HEIGHT OF ELECTRICAL OR DATA DEVICE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VT�'�B*S41WML_ DATE: 03/04/19 AREA NOT IN CONTRACT AREA OF WORK I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED I B' MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO BE WHITE. RELOCATE EXISTING OUTLETS AT SAME HEIGHT AS NEW IF THERE IS A VARIANCE. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. ALL ELECTRICAL AND MAGNETIC HARDWARE AND CONNECTIONS TO BE COMPLETED BY TENANT'S SECURITY VENDOR. 4. ELECTRICAL WORK IS LIMBED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. E01 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. E02 PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. E03 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO BASE CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 24' A.F.F. E04 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. E05 PROVIDE(1) DEDICATED QUAD IN IT ROOM INSTALLED ON PHONEBOARD. COORDINATE ALL ELECTRICAL REQUIREMENTS AND LOCATIONS WITH TENANT. E06 PROVIDE RIGID CONDUIT ALONG EXPOSED COLUMN FOR POWER AT THIS LOCATION AS REQUIRED. EO] PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE OR MAGLOCK AT DOOR FOR CARD READER (CARD READER BY TENANT(. COORDINATE WITH TENANT'S SECURITY CONTRACTOR. E 9RS6HE�U �F RR 9R D FM OE08 PROVIDE NEW DUPLEX FOR TENANT WATER HEATER AT SINK AND DISHWASHER. 0 ELECTRICAL PLAN 0 2' 4' 8' 16' H IHIS DFAWIND, AND IHE IDEAS, )ESIGNS ANDCONCEPTS CONTAINED HEREIN. ARETHE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOTTO BE 1SED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. CV ri Q NO LO r Z will W J ~ W QtnI -Q U=U 'll Z cn QQZ ZZo LL Q LJL_1 Z CW C E REVISONS MAR DATE DB DESCRIPTION 01.15.19 CRB NECKSET UPDATI 01.23.19 1 SLF REVISION2 01,30.19 1 AS I REVISION 3 PROJECT NUMBER 2018.467 PROD. Mil DRAWN BY AS SLF 4TH FLOOR ELECTRICAL PLAN E111