ELECTRICAL NOTES
I. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE
LIMITED TO BASIC DESIGN -BUILD ALTERATIONS WHICH ARE OUTLINED IN
THESE PLANS. THE DESIGN -BUILD CONTRACTORS FOR EACH TRADE MUST
NOTIFY THE ARCHITECT IF THEY FIND THAT THE SCOPE OF WORK EXCEEDS
THE LEVEL OF MECHANICAL, ELECTRICAL OR PLUMBING WORK INDICATED
ON THESE DRAWINGS SO THAT ANY NECESSARY ENGINEERING CAN
OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL
INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE
MECHANICAL, ELECTRICAL AND PLUMBING DESIGN -BUILD CONTRACTORS
SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING
CODES. FIRE SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED
BY THE APPROPRIATE DESIGN -BUILD CONTRACTOR AND MUST COMPLY
WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE
SUPPRESSION AND FIRE ALARM DESIGN -BUILD CONTRACTORS ARE
RESPONSIBLE FOR COMPLETING AND FILING THEIR PLANS AND OBTAINING
THEIR PERMITS,
2. MECHANICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES
OR MAIN EQUIPMENT ARE BEING PROVIDED, ALL MECHANICAL WORK IS
LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL
LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED:
MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF
ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED
AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL
OTHER APPLICABLE CODES,
3, VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE,
AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER
PRIOR TO ANY PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF
REQUIRED, DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE ON A SPLIT
ZONE UNLESS APPROVED BY BUILDING OWNER/LANDLORD.
4. RELOCATE AIR -SUPPLY DIFFUSERS AND RETURN -AIR GRILLES AS REQUIRED.
PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM
RETURN AIR GRILLES. LOCATION OF DIFFUSERS SHOWN ON PLAN IS FOR
REFERENCE ONLY. CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS
AND RETURN AIR GRILLES AS REQUIRED BY CODE.
5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER
MECHANICAL DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER
FOR FURNITURE PANEL OR OTHER CONFLICTS. PROVIDE BALANCE REPORTS
TO OWNER UPON COMPLETION OF PROJECT,
6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED
IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR
RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO
NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE
BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF
ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED
AND MUST COMPLY WITH ALL APPLICABLE CODES.
7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND
ALL OTHER APPLICABLE CODES.
8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS, PROVIDE OR REUSE
ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED.
9. ALL ELECTRICAL OUTLETS WITHIN 6-0 OF OF WATER ARE TO BE G.F.C.I.
10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE
CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR
PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT
FACE PLATE,
11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCH
PLATES TO MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO
FIELD VERIFY PRIOR TO PURCHASE.
12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE
SHOWN. REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA
WILL BE RUN BY THE TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL
CONNECTION FROM WORKSTATION WHIP TO JUNCTION BOX, THE
FURNITURE VENDOR IS TO BE RESPONSIBLE FOR WIRING THE BASE PANELS
OF THE WORKSTATIONS.
13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION
FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR
TO RUNNING ELECTRICAL CONDUITS TO JUNCTION BOXES.
14. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED.
PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT
FIXTURES.
15. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET
A.D.A. REQUIREMENTS AND ARE CONSISTENT THROUGHOUT,
16. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE(1) GANG BOX WITH
SINGLE COVER PLATE.
17. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED
DOW NLIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXT SIGNS
UNLESS OTHERWISE NOTED.
18. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
IT AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO
AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS
50 PERSONS OR MORE, FIXTURES SHOWN ON PLAN ARE FOR REFERENCE
ONLY.
19. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER
REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL
APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL
FIRE CODE, NFPAI. IN RECEPTION AREAS, CONFERENCE ROOMS AND
OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH
DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION,
FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS
AT THEIR EXPENSE.
20, COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE
DETECTION DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID
CONFLICT WITH FEATURE WALLS (CONFERENCE ROOMS AND RECEPTION
AREAS) AND TENANT -INSTALLED ITEMS (I.E. PRESENTATION BOARDS, A/V
EQUIPMENT AND PROJECTION SCREENS).
21, IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN
ALL LIGHTS IN EXISTING SPACES. CONSULT WITH LANDLORD. ALL LAMPS
ARE TO BE MATCHING IN CRI AND MANUFACTURER.
22. NEW AND EXISTING PLUMBING LINES IN CEILING ARE TO TO BE INSULATED.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City d Camel
�NI��V'�TI*r41rPML
DATE: \ 03/04/19
GENERAL PROJECT NOTES
I. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING
CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING
CODE.
2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE
AND LOCAL BUILDING CODES, CONTRACTORS ARE RESPONSIBLE FOR
VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR
RESPECTIVE SCOPE OF WORK.
3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE
DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING
CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE
THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY
AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK.
4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL
CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING
CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT
SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE.
5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT
ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SC HOYT
DESIGN, INC.
6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER
REGARDING ALL ON-STE ACTIVITIES: SUCH AS, BUT NOT LIMITED TO, WORK
SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE
WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES
DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE
WORK BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE
THE OVERALL PROJECT SCOPE.
7. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY
WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR
TO AND DURING HOLIDAYS, LANDLORD RESERVES THE RIGHT TO RESTRICT
CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS
DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS.
8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR
SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND
COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN
DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE
PROJECT SCHEDULE, THE OWNER,TENANT, OR DESIGNER/ARCHITECT IS NOT
RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO
COMMUNICATE MATERIAL LEAD TIMES.
9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED
WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR
SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER.
ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE
REQUEST AND RENDER A DECISION.
10. SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE
OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION
MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS
SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR
WORKERS AND THE PUBLIC AT ALL TIMES.
11. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP
PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER
TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT.
12, THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN
AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER
AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING
REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE
DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS,
13. THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE
DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND
CONSTRUCTION WORK, DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4
WOOD STUDS ® 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH
SIDE,
14. CONTACTTHE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE
DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT
THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS.
Q.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE
INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN(.
15. SCHOTT DESIGN,INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION,
DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE
TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE
PROJECTSTE,
16. PROVIDE FIRE -TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG
ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC.
FINISH NOTES
I. ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE
INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS.
2. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE
GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS,
TAPING DETAILS, CORNER BEADS, ETC.)
3. REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF
ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE
PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM
DESIRED COLOR PRIOR TO PURCHASING NEW.
4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2)
FINISH COATS.
5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR
OPENINGS AS NOTED ON FINISH PLAN Q.E. WHERE VCT MEETS CARPET).
6. WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING
WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE
SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR
TENANT AND BUILDING OWNER.
7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED.
B. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT
TO MATCH ADJACENT WALL FINISH.
9. SUBMIT FINISH SAMPLE OF MILLWORK(STAINED OR PAINTED AS SPECIFIED) TO
SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS
OF ALL MILLWORK,
10. REFERENCE INTERIOR ELEVATION& SECTIONS WHERE PROVIDED FOR
ADDITIONAL FINISH INFORMATION.
11. ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT.
12. ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT
MANUFACTURER.
17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN,
INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR
CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE
DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL
NUMBER.
18, EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW
SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND
DELIVERY OF MATERIALS AND EQUIPMENT.
19, ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST
QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR
NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL
WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING
CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL
CONSTRUCTION.
20. ALL DETAILS,MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST
APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER,
21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH
ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE
APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN
ACCOUNTED FOR BY THE BIDDER DURING PRE BID FIELD INSPECTION AND
AFTER AWARD OF CONTRACT.
22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS,
VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS
DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY
AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY
STATED TO BE PROVIDED.
23. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT
REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION.
PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR
ADJOIN TO EXISTING CORE WALLS.
24. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND
SWITCH DEVICES BEING REMOVED, PATCH HOLE WITH DRYWALL, TAPE,
SPACKLE AND PREPARE FOR FINISH.
25. ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT
ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS OR
INSTRUCTIONS.
26. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON
COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT
SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A
CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND
PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED
APPLIANCE S WORK & DO NOT LEAK,
27. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS,
OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF
THE PROJECT.
28. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW
GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL.
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN.
29. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING
WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS
WITH NEW TO MATCH BUILDING STANDARD.
30. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS,
AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE
LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED
LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS
STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT.
31, FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS
WITH APPROVED FIRE -RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS.
32. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE
RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT,
CAULKED AND FIRE DAMPERED IF REQUIRED.
33. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT
NECESSARILY AN INDICATOR OF BUILDING TYPE, BUILDING TYPE LISTED ON
LI OO IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION.
34. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING
FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED
TO RECEIVE NEW CONSTRUCTION AND FINISHES, ADJUST DOORS AND FRAMES
AS REQUIRED.
FIRE PROTECTION NOTES
weleal
I. FIRE EXTINGUISHERS: CONTRACTORTO ENSURE ALL NEWAND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING, MAXIMUM TRAVEL
DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
DEMOLITION NOTES
I. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER
TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE
ITEMS.
2. NO STRUCTURAL OR LOAD -BEARING CONSTRUCTION SHALL BE REMOVED,
DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY
NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS
DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD,
PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT
STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE
FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL
OR OTHERWISE LOAD -BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS
THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL.
EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS
ADJACENT TO OR AROUND STRUCTURAL MEMBERS, THE CONTRACTOR IS SOLELY
RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM.
3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING
THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER
THOSE ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS
OF WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S
REQUESTS.
4. WHERE EQUIPMENT,FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF
THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE
IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE
REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE
DIRECTED BY OWNER.
5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR
DASHED LINES. NOTE THATSOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION
PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION.
6. REMOVE ALL CARPEL VINYL BASE,VCT, WALL FABRIC, AND ANY OTHER FINISHES AS
REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING
CONDITIONS, REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING
FINISHES TO REMAIN.
7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED.
SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION.
S. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING
GRID INSTRUCTIONS.
9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS
TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE
SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND
FINISHES. THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S
COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE
OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION
FOR THE OWNER'S USE IN THE PROJECT.
10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF
COMBUSTION( REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND
WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING,
FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC
CABLES/RACEWAYS,AND PLTC CABLES. REFER TO SECTION 300.21.
11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING,
MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE
CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND
GOVERNING SAFETY REGULATIONS OR PROCEDURES, TAKE BACK TO SOURCE IF NOT
BEING REUSED. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE
REFERENCE. CONTRACTOR TO PROVIDE AN AS -BUILT SET INDICATING THE LOCATION
OF ALL PERMANENTLY ABANDONED SYSTEMS.
12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING
OW NER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS,
DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY.
MILL/CASEWORK NOTES
I. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE
PROVIDED UNDER THE GENERAL CONTRACT.
2. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE
(A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK.
3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE
TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION.
4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON
PLANS AGAINST DIMENSIONS OF AS -BUILT CONDITIONS IN FIELD. REPORT ANY
DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR, MAKE
ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING
50 WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS.
5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION
DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY
REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL
CONTRACTOR.
6. REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC
LAMINATE CLAD, COUNTERTOPS WITH 4' BACKSPLASHES WHERE INDICATED.
BACKSPLASHES TO BE FIELD APPLIED,
2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE
7.
EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC
GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT
LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED OTHERWISE.
DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR
IF PVC EDGING IS BEING PROPOSED BY FABRICATOR FOR EDGES OF CABINETS AND
RENOVATION OF THE FIRE SPRINKLER SYSTEM.
DRAWERS, FABRICATOR MUST PROVIDE SAMPLE OF COLOR MATCHING SPECIFIED
PLASTIC LAMINATE FOR APPROVAL.
3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING
CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES
8.
REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS
AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FI RE
(CUSTOM PLASTIC LAMINATE OR PRE -MANUFACTURED STOCK CABINETRY).
SPRINKLER/FIRE SUPPRESSION SYSTEMS,
9.
TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS,
CABINETRY WHERE SPECIFIED, ALL WOOD BLOCKING TO BE FIRE RATED,
AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE
AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT,
5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE
MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE.
FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK.
6, FIRE STOP ANY EXISTING DECK PENETRATIONS.
DOCUMENT APPROVAL
TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS.
TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME DATE
ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN -OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANpCLIENT,
THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.
T.
.I..,,i
.w.,
..,w..
me O
+fie
....
Carmel
,....
....
^ee,u
➢
n
„ram.
P
nTr NOMM1
3
t6eMmmr lrtel a,
,,....,,
-
WooalamOwmryGlU4
.i,.,,1
®
,,,.��.
- aim.rnoro�m ®,�,-
lock Golf Nub
a
3
e 9
a
Qswnys Go'
.. rai,rvr- e
rn9WOA
x-un
me
a
oli
MaIImK¢ynon¢Oam
i'd.ol
VICINITY MAP
KEY PLAN - I FLOOR
NOT TO SCALE
INDEX OF DRAWINGS
TIII COVER SHEET AND GENERAL PROJECT NOTES
LI00 LIFE SAFETY PLAN
DIII DEMOLITION PLAN
AIII ARCHITECTURAL FLOOR PLAN
AI21 REFLECTED CEILING PLAN
A131 FINSH PLAN
A211 DOOR SCHEDULE/ INTERIOR DETAILS
El II ELECTRICAL PLAN
NOT TO SCALE
H
THIS Di AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
W
~
J
LLJ
Q
5
Z
--Q
LU
-
U
Z
Y
~
I_
Q
Q
Z
�Q
2
Zz
o
`L
-
L`LJ
L
Ly
z
C
C
all
ISSUE
wall
DALE DESCRIPTION
12.21.18
PERMIT SET
01.15.19
CONSTRUCTION SET
REVISIONS
ARK DATE I DB DESCRIPTION
01.15.19
CRB
CHECKSET UPDATE
01.23.19
SLF
REVISION2
01.30.19
AS
REVISION 3
PROJECT NUMBER
2018.467
PROJ. MGR DRAWN BY
AS SLF
4TH FLOOR
COVER SHEET AND
GENERAL NOTES
T111
2
3
4
5
6
7
6
9
10
11
12
13
14
15
16
CODE SUMMARY
SCOPE OF WORK
OFFICE REMODEL OF PREVIOUSLY OFFICE SPACE
PREVIOUS USE OF SPACE
BUSINESS)
OCCUPANCY CLASSIFICATION
BUSINESS)
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
VARIES SF/FLOOR
X
1 8STORIES
-
214,546 SF
TOTAL PROJECT AREA
5793 SF
SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD
OCCUPANCY CALCULATIONS
NUMBER OF EXITS
GEN.OFFICE
5793 SF
100
58
TOTAL OCCUPANTS IN PROJECT AREA 58
REQUIRED:2 PROVIDED:2
SPRINKLER SYSTEM (YES/NO)
YES- EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTALAREA ON THE FLOOR
22,478 SF
ACCESSORYAREA EXCEEDS 10%
NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
ASHRAE 90.1 SUMMARY
REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 1978?
NO
BUILDING CONSTRUCTION TYPE
1-9
LEGEND
Ep EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT. BUILDING STAIR LOCATION
�I®
FIRE EXTINGUISHER
EXIT SIGN - LED EDGE LIT
q®
®
EMERGENCY LIGHT
— — —
TRAVEL DISTANCE
NIGHT LIGHT/EMERGENCY LIGHTING
Nut (NIGHT LIGHTS ARE HOOKED UP TO
BUILDINGS EMERGENCY GENERATOR)
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
�TG'UB*S41WML
DATE: \ 03/04/19
® AREA NOT IN CONTRACT
❑ AREA OF WORK
LIFE SAFETY NOTES
I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
ELECTRICIAN TO RELOCATE EXISTING. ANY NEW FIXTURES TO BE
ADDED BY OWNER'S LIFE SAFETY VENDOR ONLY.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING, MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER. FIRE EXTINGUISHERS PROVIDED BY
TENANT.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
GENERAL NOTES
LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS
REQUIRED TO MEET ALL LOCAL AND STATE CODES.
LIFE SAFETY PLAN
0 4' 8' 16'
H
)ESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLFCTUAL PROPERTY OFTT T TOO DESIGN, INC.. AND ARE NOT TO BE
15E OR REPRODUCED IN WHOLE. OR I
C PARE TWITHOUT THE
OF SCHOTT WRITTEN
CONSENT OF SCHOTT DESIGN.
CV
C)
LO
iiz
v-
W
J
~
WC
=
Q
-Q
V=U
Z
Q
Q
Z
ZZo
Li
a
L`LJ
L
z
CIUI
C
E
REVISIONS
MAR
DATE
DB
DESCRIPTION
01.15.19
CRB
%ECKSET UPDATI
01.23.19
1 SIR
1 REVISION2
01,30.19
1 AS
I REVISION 3
PROJECT NUMBER
2018.467
PROD. MGR DRAWN BY
AS SLF
4TH FLOOR
LIFE SAFETY
L 100
ARCHITECTURAL LEGEND
WALL
THICKNESS
NEW CONSTRUCTION
EXISTING TO REMAIN
wwwwiim WALL
WALL
o PARTIAL HEIGHT WALL
O PARTIAL HEIGHT WALL
�o WINDOW/SIDELIGHT
a—¢ WINDOW/SIDELIGHT METALSTUD
DOORANDFRAME
(SEE DOOR SCHEDULE)
DOOR AND FRAME
77
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE W1 UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT/ GREEN BOARD AS REQUIRED IN
RESTROOM Al SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
0 WALL WITH INSULATION
35/"METALSTUDS AT 16" O.C.;
ONE LAYER OF 5/a" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2-0 EACH EACH SIDE OF WALL ABOVE
CEILING
9 STANDARD WALL
35/8" METAL STUDS AT 16" O.C.;
ONE LAYER OF z% TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING
DEMISING WALL TO DECK
WITH INSULATION
3SV" METAL STUDS AT 16" O.C.:
ONE LAYER OF %" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK:
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL
H PARTIAL HEIGHT WALL
35% MRALSTUDS Ai 16" O.C.;
ONE LAYER OF 5%' TYPE "X" GYPSUM BOARD
EACH SIDE;
SEE ELEVATION FOR WALL HEIGHT;
PROVIDE I"STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED:
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City Bf Camel
DATE: 03/04/19
EXISTING WIN
MULLION
PRE -FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
n WALL AT MULLION DETAIL
A I I I NOT TO SCALE
GENERAL NOTES
I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT
2, REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
W ALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
PLAN NOTES
A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
A02 PROVIDE PLYWOOD PHONE BOARD, 4'XB>J, PAINTED WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET
A03 TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE
EXTINGUISHERS ARE TO BE PROVIDED BY TENANT AND INSTALLED
ACCORDING TO NFPA 10.
PROVIDE COAT ROD AND SHELF AT THIS LOCATION; SEE DETAIL
A04 2/A211 FOR MORE DETAILS. PROVIDE (2) BRUSHED CHROME
DOUBLE COAT HOOKS AT MAXIMUM 48" A.F.F. FOR ADA
COMPLIANCE AT THIS LOCATION.
PROVIDE NEW PLASTIC LAMINATE IPL21 ISLAND COUNTER ON
A08 PARTIAL HEIGHT WALL AS SHOWN. ON SOUTHEAST SIDE OF
ISLAND, COUNTER TO BE AT 42" AFF AND OVERHANG PARTIAL
HEIGHT WALL TO ALLOW FOR SEATING. SEE ELEVATION 4/A211
FOR BASE CABINETS ON NORTHWEST SIDE OF ISLAND. SUPPORT
COUNTER AS REQUIRED WITH CENTERLINE BRACKET'S FRONT
MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WITH
WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL
SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS
NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE
APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION
AS NEEDED.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
AOB TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
AO] ALIGN FINISHED WALL SURFACES WITH EDGE OF CONCRETE
COLUMN. COLUMN TO REMAIN UNFINISHED; CLEAN AS MUCH
AS POSSIBLE.
A08 COLUMN TO REMAIN UNFINISHED; CLEAN AS MUCH AS POSSIBLE.
P01 PROVIDE POTABLEHOT AND COLDWATER ANDSANITARY WASTE
AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE
OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING.
PROVIDE A 6GALLON WATER HEATER FOR SINK. REFER TO
ANDLO D FOR XACi LOCATICN.
0
AREA NOT IN CONTRACT ARCHITECTURAL PLAN
❑ AREA OF WORK 0 2' 4' 8' 16' ®N
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH OTT DESIGN.
N
Q
LO
will
W
J
~
W
Z
--Q
LU
Z�cn
N_
Q
<
7
2Z�o
aaa�
Z
ni
LL = W
0 5
5w z
SSU E
DATE DESCRIPTION
12.21.18
PERMITSET
01.15.19
CONSTRUCTION SET
EVISONS
MARK DATE DB DESCRIPTION
01.15.19
CRB
CHECKSET UPDATE
01.23.19
SEE
REVISE ON2
01.30.19
AS
REVISION 3
PROJECT NUMBER
2018.467
PROD. MGR DRAWN BY
AS SLF
4TH FLOOR
ARCHITECTURAL
FLOOR PLAN
A111
LEGEND
NEW OR RELOCATED
EXISTING TO REMAIN
LIGHT FIXTURE, 2'x4',
LIGHT FIXTURE, 2'x4',
BUILDING STANDARD LED
FLUORESCENT, PARABOLIC
LIGHT FIXTURE, 2'x2',
LIGHT FIXTURE, 2'x2',
BUILDING STANDARD LED
FLUORESCENT. PARABOLIC
RECESSED FIGHT
K(
RECESSED LIGHT
FIXTURE
FIXTURE
40
DIRECTIONAL RECESSED
LIGHT FIXTURE
NL
NIGHT LIGHT
3
EXIT LIGHT FIXTURE
®
EXIT LIGHT FIXTURE
EMERGENCY LIGHT
EMERGENCY LIGHT FIXTURE
FIXTURE
INN
LIGHT SWITCH
LIGHT SWITCH
$N3
LIGHT SWITCH, SWAY
Y3
LIGHT SWITCH, SWAY
$ND
LIGHT SWITCH. DIMMER
$D
LIGHT SWITCH. DIMMER
$NP
SWITCH, PROJECTOR SCREEN
'PP
SWITCH. PROJECTOR SCREEN
$NG
SWITCH, GARBAGE DISPOSAL
$G
SWITCH, GARBAGE DISPOSAL
(ABOVE COUNTERTOP)
$NE
SWITCH, EXHAUST FAN
$G
SWITCH, EXHAUST FAN
i —
LIGHTCIRCUR
LIGHTCIRCUR
CEILING GRID, i- CEILING GRID,
SUSPENDED, Zx4' _yr_ SUSPENDED, Zx4'
CEILING GRID, CEILING GRID,
SUSPENDED, Z& _ SUSPENDED, Z&
1
CEILING GRID, SUSPENDED,
GRID ES TO COMPLETE I CEILING GRID.
GRID i i SUSPENDED, 4'x4'
I I
GYPSUM BOARD GYPSUM BOARD CEILING
CEILING
1-1 EXPOSED TO DECK
RELOCATED
DIFFUSER, LAY IN, Z&
RELOCATED
® DIFFUSER, LAY IN, IX4'
RELOCATED
DIFFUSER, LAY IN, 4'k4'
® EXHAUST FAN, 2 x2'
® EXISTING DIFFUSER, LAYLI 2'x2'
® EXISTING DIFFUSER, LAY- IN, IX4'
EXISTING DIFFUSER, LAY -IN,
m 4'M4
Fol EXISTING EXHAUST FAN, ZX2
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NONEW
HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
RELOCATE DIFFUSERS &
GENERAL NOTES
PROVIDE NEW BUILDING STANDARD 2X2CEILING GRID AND
TILE INSTALLED AS HIGH AS POSSIBLE FOR UNIFORM HEIGHT ON
ENTIRE 4TH FLOOR. CONFIRM EXACT SPECIFICATIONS WITH
LANDLORD.
2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS
REQUIRED PER NEMA AND IBC. LIGHTS CONNECTED TO AN
EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE
CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN
ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS
WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE
APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE
TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE
ITEMS ATTHEIR EXPENSE,
3. LAYOUT SHOWN IS INTENDED TO MEETASHRAE 90.1
STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO
MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER
50%OF THE LIGHTING WILL BE REPLACED WITH NEW, SO
ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET.
4. UNLESS NOTED OTHERWISE, ALL NEW SWITCHES MUST BE AN
OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC
AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE.
OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT
OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS
DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY
SENSORS IN OPEN AREAS AS REQUIRED,
5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE
WHITE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTISWITCHPLATE WHEN SWITCHES ARE SHOWN ADJACENT
ON PLAN.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND
IS OUTLINED IN THESE DRAWINGS, ALL ELECTRICAL WORK IS
LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL
OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE
CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE
BUILDING, ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE
PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES,
nMECHANICAL DIFFUSER RELOCATION
RELEASED FOR CONSTRUCTION `REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
Subject to compliance with all regulations
of State and Local Codes
City of Camel /�
�ja GsUDaS41WML_
DATE: \ 03/04/19
MECHANICAL NOTES
I. M EC HA N ICA L WO R K IS LIMITED TO A DESIGN -BUILD SCOPE
AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN
MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING
PROVIDED. ALL MECHANICAL WORK IS LIMITED TO
RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL
LAYOUT. NO NEW HARD DUCDNORK OR EQUIPMENT IS BEING
ADDED: MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY
WITH THE IN DIANA MECHANICAL CODE AND ALL OTHER
APPLICABLE CODES.
2. HVAC LAYOUT TO BE APPROVED PRIOR TO WORK BEING
COMPLETED. FILTERS MUST BE CHANGED AT CLOSE OF
PROJECT AND ALL THERMOSTATS MUST BE CALIBRATED AND
AIR BALANCED. PROVIDE REPORT TO OWNER.
PLAN NOTES
R01 CONTROL ENTRY, CORRIDOR, BREAK AND OPEN OFFICE LIGHTING
WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE
SWITCHES AS REQUIRED.
4'X4' CEILING GRID TO BE INSTALLED THROUGHOUT ENTIRE 4TH
R02 FLOOR. COORDINATE EXACT REQUIREMENTS WITH LANDLORD.
® AREA NOT IN CONTRACT REFLECTED CEILING PLAN
❑ AREA OF WORK 0 2 4 B 6' N
THIS DRAWING. AND THE IDEAS.
DESIGNS AND
CONCEPTS CONTAINED
HEREIN,
ARE THE EXCLUSIVE
INTELLECTUAL
PROPERTY OF SCHOTF
DESIGN. INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART.
WITHOUT THE
WRITTEN
CONSENT OF SCH 07 DESIGN.
CV
0
Nq
Z
W
J
~
LLJ
Z
--Q
Z
i
V)
2
Z
o_
II•
aaaaaa�
Zz
/
ll/
Li Q lu-
L
SIuI z
L
SSUE
DATE DESCRIPTION
12.21.18
PERMITSET
01.15.19
CONSTRUCTION SET
EVISONS
ARK DATE I DB IDESCRIPTION
01,15.19
CRB
CHECKSET UPDATE
01.23.19
SELF
REVISION2
01.30.19
AS
REVISIONS
PROJECT NUMBER
2018.467
PROD. MGR DRAWN BY
AS SLF
4TH FLOOR
REFLECTED
CEILING PLAN
JAl21
LEGEND
FLOOR COVERINGS
CARPET
MFG: SHAW
CONTRACT
DPTt
TYPE:
BROADLOOM
PATTERN:
TONE5AI52
COLOR:
METAL GREY 51585
1VT1 MFG: MANNINGTON COMMERCIAL
SIZE: 3" X 36'
PATTERN: AMTICO WOOD
COLOR: QUILL GESSO
NOTE: PROVIDE SKIMCOAT OF ARDEX LEVELING LATEX
AS NEEDED FOR SMOOTH SUBFLOOR THAT WILL NOT
ALLOW FOR TELEGRAPHING OF IMPERFECTIONS IN THE
FLOOR
INSTALL: STAGGER PLANKS. LENGTH OF PLANKS TO RUN
IN DIRECTION OF ARROWS ON PLAN.
WALL BASE
VBt MFG: JOHNSONITE
TYPE: 4" VINYL COVEY' GAUGE
COLOR: 63 BURNT UMBER
PAINT / WALLCOVERING
Rt MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: SW7056 RESERVED WHITE
FINISH: EGGSHELL
O MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: SW9163 TI N LIZZIE
FINISH: EGGSHELL
PT3 MFG: SHERWIN WILLIAMS
TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX
COLOR: SW2839 ROYCROFT COPPER RED
FINISH: EGGSHELL
PLASTIC LAMINATE / SOLID SURFACE
PLi MFG: NEVAMAR ICOUNTERTOPI
COLOR: SMOKY WHITE #S70D1
®MFG: WILSONARi ICABINETRYI
COLOR: STH AVE. ELM #7966
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City d Camel
�VT�LJ'�B*S41WML_
DATE: \ 03/04/19
GENERAL NOTES
PLAN NOTES
I. REFER TO LEGEND FOR ALL ACCENTOPECIALTY PAINT OR PROV I DE JOHNSON UE SLIM LINES LT-63-F PROFILE TRANSITION STRIP
F01
WALLCOVERING THAT REQUIRES LEVEL 4OR LEVEL 5 DRYWALL AT FLOORING TRANSITION; COLOR: BURNT UMBER. CONTRACTOR
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. MUST PROVIDE LEVELING LATEX SUCH THAT HEIGHTS OF MATERIALS
ARE APPROPRIATE FOR USE WITH SPECIFIED PROFILE TRANSITION.
BE AWARE TRANSITION STRIP MUST BE ORDERED IN A TIMELY
MANNER AS IT IS NOT ALWAYS IMMEDIATELY AVAILABLE.
NO FINISHED FLOORING IN THIS ROOM UNLESS OTHERWISE NOTED;
F02 PROVIDE APPROPRIATE TRANSITION STRIP WITH CARPET.
DPTt
STG. Vlit �1
AREA NOT IN CONTRACT
AREA OF WORK
FINISH PLAN
0 24' 8' 16'
%M11611111010I
THIS DRAWING, ANDTHE IDEAS,
DESIGNS AND CONCEPTS CON INED
HEREIN. ARE THE EXCLUSIVE
IMELLECTUAL PROPERTY OF SCH07
DESIGN, INC.. AND ARE NOTTO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
CV
Q
U
W
J
~
W
Z
--Q
LUVY�
Z
V)
_
�QQ7
2Zzo
�
Z
ni
Li = III J
LU z
C
SSUE
DATE DESCRIPTION
12.21.18
PERMITSET
01.15.19
CONSTRUCTION SET
EVISONS
ARK DATE I DB DESCRIPTION
01.15.19
CRIB
CHECKSETUPDATI
01.23.19
SLF
REVISION2
01.30.19
AS
REVISION3
NUMBER
2018.467
PROJ. MGR DRAWN BY
AS SLF
4TH FLOOR
FINISH PLAN
(>N (Al 31
o
TO IXLSTNG
STACK
Kx
P
s7CENTERSUPPORTRACKET.
.)...,'
ucK UEwnrvesHEv
cLG.
difv_�E i
i pp. MCI
END)
I )
�IXIS(
INK
yW.
E: WHERESPAN
RI(
EEW 4'L'. EA
FF. )
NOTE: REFERW FLOORPLAN
AND CASEWORK ELEVATIONS
MR SINK LOCATIONS.E
FROVOE(So
PUSHT DOUBLE
OOFSAT
TIIOOUATUAKIUIx,.FFNEnon
MrIIANCE.
—+ TO
4'W.
BUILDING
DRNN
RISER
DIAGRAM
DETAIL
(2)COAT/ROD
A211 TYPICAL ALL SINGLE LOCATIONS, NOT TO SCALE
7T2"
0 3" 6"
1' 2'
3'3"
33
33 33 33
1'7
WALLCA&NEE
(SEE CASEWORK NOTE I
—
SINGLE BOWL SINK: 18 GAUGE
----�I
KOHLER TOCCATA (OR EQUAL)
REFRIG. BY
WITH MOEN AWN FAUCET
LID TENANT II
#7se5SRS (OR EQUAL
IF—
—1I
-
24" DEEP PLASTIC LAMINATEIrILO
II
II
(PI21 COUNTERTOP WRH 4"
HIGH BACK "L.
'
MICROWAVE
BOX
! j
DISHWASHER �\
— _
BY TENANT:
.-
`�
_
GEMODEL#
BASECARNETS
��
[SEE CASEWORK NOTE I I
DT22GGLW
L____—.1
3-0 IP)
26
33' 33
2UU 1-3
1-7
n
ELEVATION -
BREAK
418
A211
0 1' 2'
4'
J•J,
I 3 3"
1'7
24" DEEP PLASTIC LAMINATE (PL21 COUMERIOR
SUPPORT COUNTER AS REQUIRED WITH CENTERLINE
BRACKETS FRONT MOUNTING PLUS BRACKET ATTACHED
TO METAL STUDS WITH WOOD BLOCINNG AND DRYWALL
INSTALLED OVER VERTICALSUPPORT. CASEWORK
CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR
TO INSTALLATION OF DRYWALL COORDINATE APPROVAL
OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS
NEEDED, COUNTER TO OVERHANG ON OPPOSITE SIDE OF
BASE CABINETS TO ALLOW MR STOOL SEATING. PARTIAL
HEIGHT WALL ON OPPOSITE SIDE OF BASE CANNED TO BE
PAINTED DRYWALL FlNISH WITH BASE AS SCHEDULED
RPDEEP PLASTIC LAMINATE PL21 COUNTERTOP WITH FULL
HEIGHBACKSPLASH
RASE CABINETS
(SEE CASEWORK NOTE 1)
n ELEVATION - BREAK 418 ISLAND
0 1' 2' 4
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
aT, City of Camel
IVT�L7tBN�SDAAK
DATE: \ 03/04/19
CASEWORK NOTES
GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN
ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF
BASE CABINET PRIOR TO ORDERING,
PROVIDE A.W.I. CUSTOM GRADE, FLUSH -OVERLAY CABINETS. FABRICATE
WITH PLASTIC LAMINATE (PLII COVERED M.D.O. BOARD WITH MOCKETT
DP3B4 PULLS, FINISH: SATIN CHROME, COORDINATE WITH ELEVATIONS
FOR QUANTITIES.
-AT BREAK ROOM PROVIDE:
24" DEEP COUNTERTOPS
23" DEEP BASE CABINETS
I IY" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS
- 4" BASE AT CABINETS TO BE VINYL BASE AS SPECIFIED, UNLESS
NOTED OTHERWISE.
DOOR SCHEDULE
# DIMENSIONS I DOOR FRAME HARDWARE REM.
01
3'-MX8'-0k
TYPE
D3
MATERIAL FINISH
GM
TYPE I MATERIAL I FINISH
ELCR,
02
4
BIRCH VNR.
AL MATONE
03
3'-0'k8'-O'k13/"
D2
ID CORE
BRLCH VNR.
TBD
FI
TIMELY
ALUMATONE
PS
04
3'-0'k8'-O'k13/"
D2
ID CORE
BRLCH VNR.
TBD
F2
TIMELY
ALUMATONE
PS
05
3'-0'k8'-O'k13/"
D2
SOLID
g RCH VNR. E
TBD
F2
TIMELY
ALUMATONE
PS
Ob
3'-0'k8'-O'k13/"
D2
SOLID CORE
BIRCH VNR.
TBD
F2
TIMELY
ALUMATONE
PS
07
3'-0'k8'-O'k13%'
D2
SOLID CORE
BIRCH VNR.
TBD
F2
TIMELY
ALUMATONE
S
08
3'-0'k8'-O'k13%'
DI
SOLID
LCH CORE
TBD
F2
TIMELY
ALUMATON
OL
09
3'-0'k8'-O'k13/"
DI
BRLCH COID RE
TBD
F2
TIMELY
ALUMATO
OL
10
3'-0'k8'-O'k13/"
DI
BRLCH COID RE
TBD
F2
TIMELY
ALUMATON
OL
11
3'-0'k8'-O'k13%'
DI
BRLCH COID RE
TBD
F2
TIMELY
ALUMATON
OL
12
3'-0'k8'-O'k13%'
DI
BRLCH COID RE
TBD
F2
TIMELY
ALUMATO
OL
13
3'-0'k8'-O'k13/"
DI
SO CR
CORE
TBD
I F2
TIMELY
ALUMATO
OL
14
3'-0'k8'-O'k13/"
D1
ID CORE
BRLCH VNR.
TBD
F2
TIMELY
ALUMATON
OL
15
3'-0'k8'-O'k13%'
D1
BRLCH COID RE
TBD
F2
TIMELY
AWMATO
OL
Ib
3'-0'k8'-O'k13/"
SOLID CORE
BIRCH VNR.
TBD
FI
TIMELY
ALUMATONE
L,
17
3'-0'k8'-O'k13%'
D2
OLD CORE
BIRCH VNR.
TBD
FI
TIMELY
ALUMATONE
CR, ES, SL, CL
RI
18
3'-0'k8'-O'k13%'
SOLID CORE
BIRCH R.
TBD
FI
TIMELY
ALUMATONE
P L
19
3'-0'k8'-O'k13W"
D1
BRLCH v�RE
TBD
FI
TIMELY
ALUMATONE
OL
DOOR/FRAME TYPES
D1
D2
VERHEAOC
3'-0" 3'-0"
0 BE DOi
.75 STAINLES
\ SELL TOP RAI
TOP ANDBBOI
PPP
PHNIOIA
IYL' TEMPERED GLASS
ROVIDE ONE PULL ON
EACH SIDE OF DOOR
(TOTAL COUNT 2). PULL
TO BE CR LAURENCE
DLLPA48BS
D3
m
3'4'
F1
F2
F3
REMARKS
RI. SEE DOOR TYPE D3 FOR ALL REQUIRED HARDWARE AT HER CU LITE
ENTRY DOOR SYSTEM, PROVIDE DRYWALL WRAPPED OPENING AT
rHls LocgnoN. p
R2. LANDLORD TO PROVIDE 24-VOLT ELECTRONIC STRIKE WITH WIRING
HARNESS.
HARDWARE LEGEND
CL CLOSER
CH COAT HOOK
CR CARD READER BY TENANT (N.I.C.)
DB DEADBOLT
DL DUMMY LEVER
I
ES ELECTRICSTRIKE BY CONTRACTOR (SPEC PROVIDED BYTENANTIx
KP KICK PLATE
KS KICK STOP
OL OFFICE LOCKSET
PH PANIC HARDWARE
PL PRIVACY LOCKSET
PP PUSHI
PS PASSAGE LATCHSET
PV PIVOT HINGE
RL ROLLER LATCHES
SL STOREROOM LOCKSET
TS TOP STRIKES
DOOR/FRAME NOTES
I. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER
AS REQUIRED. PRE -MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS.
2. PROVIDE NEW BUILDING STANDARD HARDWARE, FOR NEW DOOR
HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD. PROVIDE
A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS.
3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED.
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL
CORNERS UNLESS OTHERWISE NOTED ON PLAN.
5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND
LOCKSETS.
6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION,
PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED
ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES.
ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE
INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS.
7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
7'-0' Hi, TO HAVE 3 HINGES
GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES
• FINISH TO MATCH HARDWARE SET
8. PROVIDE (I I SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE
NOTED.
9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR
UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL
STOP.
THIS DRAWING, AND THE IDEAS,
)ESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOTTO BE
1SED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
CV
O
10
, ^
LO
�
�
z
~
Wmi
J
W
I
N
Z
-Q
ZY
V)
Q
Q
Z
Z
Q
C)
Li
L`LJ
L
LKi
W
z
SSUE
mi
DATE DESCRIPTION
12.21.18
PERMITSET
01.15.19
CONSTRUCTIONSET
EVISONS
ARK DATE I DB DESCRIPTION
01.15.19
CRB
CHECKSETUPDATI
01.23.19
SUE
REVISION 2
01.30.19
AS
REVISION 3
PROJECT NUMBER
2018.467
f'7Zi71ALLC R ;H a 7 7\577�1a
AS SLF
4TH FLOOR
DOOR SCHEDULE
INTERIOR DETAILS
A2 1 I
LEGEND
GENERAL NOTES
PLAN NOTES
NEW CONSTRUCTION
EXISTING TO REMAIN
POWER OUTLET, DUPLEX
POWER OUTLET, DUPLEX
'N
POWER OUTLET,
POWER OUTLET,
QUADRUPLEX
QUADRUPLEX
8
JUNCTION BOX
QJ
JUNCTION BOX
OCEILING
MOUNTED
CEILING MOUNTED
JUNCTION BOX
JUNCTION BOX
®
BOX, BLANK COVER PLATE
®
BOX, BLANK COVER PLATE
®
BOX, OPEN
QO
BOX, OPEN
p
POWER POLE FOR
P
POWER AND DATA POLE
■
ELECTRICAL AND DATA.
D
PROVIDE JUNCTION BOX
ABOVE CEILING.
FLOOR BOX WITH POWER
FLOOR BOX WITH POWER
� 44
AND DATA, FLUSH
E
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WITH
FLOOR BOX WITH
®
JUNCTION BOX AND
J 171
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
DATA/COMMUNICATION
14
OUTLET (PROVIDE BOX
IQ
AND PULL STRING ONLY(
OUTLET
DED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42'
HEIGHT OF ELECTRICAL
OR DATA DEVICE
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VT�'�B*S41WML_
DATE: 03/04/19
AREA NOT IN CONTRACT
AREA OF WORK
I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED I B' MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
NEW DEVICES AND FACE PLATES TO BE WHITE. RELOCATE EXISTING
OUTLETS AT SAME HEIGHT AS NEW IF THERE IS A VARIANCE.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. ALL ELECTRICAL AND MAGNETIC HARDWARE AND
CONNECTIONS TO BE COMPLETED BY TENANT'S SECURITY VENDOR.
4. ELECTRICAL WORK IS LIMBED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
E01 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
E02 PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE
SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S
FURNITURE VENDOR.
E03 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO BASE CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED
AT 24' A.F.F.
E04 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
LOCATION WITH TENANT.
E05 PROVIDE(1) DEDICATED QUAD IN IT ROOM INSTALLED ON
PHONEBOARD. COORDINATE ALL ELECTRICAL REQUIREMENTS
AND LOCATIONS WITH TENANT.
E06 PROVIDE RIGID CONDUIT ALONG EXPOSED COLUMN FOR POWER
AT THIS LOCATION AS REQUIRED.
EO] PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE OR
MAGLOCK AT DOOR FOR CARD READER (CARD READER BY
TENANT(. COORDINATE WITH TENANT'S SECURITY CONTRACTOR.
E 9RS6HE�U �F RR 9R D FM
OE08 PROVIDE NEW DUPLEX FOR TENANT WATER HEATER AT SINK AND
DISHWASHER.
0
ELECTRICAL PLAN
0 2' 4' 8' 16'
H
IHIS DFAWIND, AND IHE IDEAS,
)ESIGNS ANDCONCEPTS CONTAINED
HEREIN. ARETHE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOTTO BE
1SED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
CV
ri
Q
NO
LO
r
Z
will
W
J
~
W
QtnI
-Q
U=U
'll
Z
cn
QQZ
ZZo
LL
Q
LJL_1
Z
CW
C
E
REVISONS
MAR
DATE
DB
DESCRIPTION
01.15.19
CRB
NECKSET UPDATI
01.23.19
1 SLF
REVISION2
01,30.19
1 AS
I REVISION 3
PROJECT NUMBER
2018.467
PROD. Mil DRAWN BY
AS SLF
4TH FLOOR
ELECTRICAL PLAN
E111