HomeMy WebLinkAbout19020100 Building PlansPROJECT TEAM RAYMOND JAMES RENOVATION ZELLER REALTY GROUP 11611 N MERIDIAN STREET, SUITE 600 CARMEL, INDIANA 46032 VICINITY MAP s M RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/06/19 r�q 16111 N MERIDIAN ST. KEY PLAN 0 SIXTH FLOOR IV LEASING DIRECTOR ZELLER REALTY GROUP NICK TRIMPE 11611 N MERIDIAN STREET- SUITE 120 CARMEL, IN 46032 PHONE: (317)580-2415 EMAIL: NTIMPE@ZELLERREALTY.COM VICE PRESIDENT OF CONSTRUCTION ZELLER REALTY GROUP JESSICA SMITH 11611 N MERIDIAN STREET- SUITE 120 CARMEL, IN 46032 PHONE: (317)580-2430 EMAIL: JSMITH@ZELLERREALTY.COM TFNANT RAYMONDJAMES STEPHEN K. HALL 12800 N MERIDIAN STREET, SUITE 100 CARMEL, IN 46032 PHONE: (317)848-4610 EMAIL: STEPHEN.HALL@RAYMONDJAMES.COM INTERIOR DESIGNER Ift MITSCH DESIGN COURTN EY ROESSLER- SENIOR PROJECT DESIGNER 200 SOUTH RANGELINE ROAD, SUITE 226 CARMEL, IN 46032 PHONE: (317) 573-222 FAX: 573-2230 m i t s c h EMAIL:L: CROESSLER@MITSCHDESIGN.COM E)ESIGN 200 s rangeline road INTERIOR DESIGNER suite 226 MITSCH DESIGN ca"el, indiana46032 ERIN SANFORD - DESIGN DIRECTOR ph 317.573.2222 200 SOUTH RANGELINE ROAD, SUITE 226 fx 317.573.2230 CARMEL, IN 46032 PHONE: (317) 573-222 www.mitschdesign.com FAX: (317) 573-2230 EMAIL: ESANFORD@MITSCHDESIGN.COM ARCHITECT MITSCH DESIGN SALIL NAIR- PRINCIPAL ARCHITECT 200 SOUTH RANGELINE ROAD, SUITE 226 CARMEL, IN 46032 " - ' ' PHONE: (317) 573-2222 FAX: (317) 573-2230 EMAIL: SNAIR@MITSCHDESIGN.COM W Q 0 z O LL_ Z Q J n LU U a. U) O O J LL SHEET LIST G000 COVER SHEET €• No'MisSODale G001 LIFE SAFETY PLAN G002 GENERAL NOTESANDWALL & DOORTYPES eT/IEaF' G003 ACCESSIBILITY DETAILS'• D101 DEMOLITION PLAN CHI D201 REFLECTED CEILING DEMOLITION PLAN A101 CONSTRUCTION PLAN `LiFI A102 ENLARGED CONSTRUCTION PLANS A201 REFLECTED CEILING PLAN A601 INTERIOR ELEVATIONS A602 INTERIOR ELEVATIONS A603 INTERIOR SECTIONS w A700 INTERIOR ROOM FINISH SCHEDULE 6 injp w A701 INTERIOR FINISH PLAN g�JSO r w F¢ — AE101 ELECTRICAUDATA PLAN y�'�ww MW yw — _ mN�Qy mr E w m ZNjj w i ft t = mFwr� WUWW l� ¢¢ in e$$_$$D_$$$Q $$$N Ludo %yo Lum iF##iF O Oil 0 iG II#iG it aaa#R aia JU WK O Z DRAWN BY: CR/ME CHECKED BY: ES MD PROJECT#: 18043 COVER SHEET G000 SCALE: 112"=1'-0" �l SHRED BIN SCALE: 112"=1T' 3'-0" 3'-0" 3'-W PL-2 1/4" COPPER WATER LINE COFFEE MAN P VIDEDB' N PLA PL-2 EI I 'ILI I T-0" T-0" T-0" 9 BREAK ROOM ELEVATION B SCALE: I12' = T-0" rE III IIIII�" °Ill -r" °11 "xr Pt-2 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ��GGs B DATE: 03/06/19 PL-3 41 L 14 SCALE: R"=1'-0' PLA oDoo e 2 NORTH COPY ROiO'M ELEVATION B SCALE: 112"=1'-0" —� PL-2 EQ EQ EQ EQ PL-2 o ` 17 VIF PLA IN PL-2 r/M SCALE: 112"= T-T EQ PLA PL-2 SHRED BIN i PLA PL-2 2 1 A603 A803 PLA a e o0 0 L- - OU OUT TRA H TRASH BIN BIN 3'-0" 3'-0" T-11/2" 01- 4 LARGE CONF. ROOM ELEVATION B SCALE: 112"=1'-0" V-111/4" 1 4' - 1 1 /4" +/- L P' 9" P' P' —_ P' 1'- 1/2• 3•-0. NGLED ANGLE 6 SOUTH COPY ROOM ELEVATION A 7 SOUTH COPY ROOM ELEVATION B 8 COPY ROOM ISLAND BACK SCALE: 112=T-0" 3'-0" 3'-0" Y w 3-0"1 1'-71/2" 3'-0" 3'-0" A Mu SCALE: 112"=1'-0" SS-1 WATERFALL EDGE SCALE: 112' = T-T SCALE: 11T =1T' 3 OOUG MOCKETT 6" DIAMETER TRASH CHUTE LOCKING 3 2 1 11W COPPER (2 DRAWERS) AfiO3 AfiO3 A603 WATER LINE FOR COFFEE MAKER PROVIDED BY GC SS-1 SS-1 FILE DRAWER PI-4 e o e UNDER COUNTER REF. PULL-OUT TRASH BIN 2' 11/4" 3'-0" EQ EQ PT-1 PLA SCALE: 11T= 1T' 0" COUNTERTOP: PL-1 T MAXIMUM RADIUSED CORNERS, ALL CORNERS PL-2 ALL SIDES ON BACK AND SIDES (WHERE NO TOE KICK) UTILIZE VB-1, TYPICAL SCALE: 112' =1T' 2 1 AfiO3 AfiO3 114' PT-1 COPPER WATER LINE FOR COFFEE TRASH CHUTE, MAKER PROVIDED RECESSED IN BY GC COUNTERTOP 5FL Oe L RED WATER CA ON �� L-2 37-0" P-3" 12 COFFEE ROOM ELEVA SCALE: 11T=T-T EQ. EQ. TELEVISION P OVIDED BY 2 1 TENANT A603 A603 00 00' Ll LID T-0" T-0' T-6112' 1616 SMALL CON SCALE: 112'=1'-0" PT-3 DUPLEX RECEPTABL E, TEUDATA & HDMI/VGA PORTS PROVIDED BY GC AT 66" A. SS-1 1 PUL LeL7 H PLC T-61/2" T-0" T-0" ROOM ELEVATION ' mitsch IDESIGN 200 s rangeline road suite 226 carmel, indiana 46032 ph 317.573.2222 fx 317.573.2230 www.mitschdesign.mm Z ^J LL UJ U < p (D !^^ Vl !a!^. Vl F LU Q F- M O LU CN L.L z V r� v' Z Q LC Z O EE o LLJ �? l0/� VJ G Z w W G CO �U xxxnx,.rxy .``�x5 p\STfq ° -g_ w � N Wk 00 o €w zww 0 og wo ��dWRQN in m�� wfi p xA� P 4 o 0 i zwo� <wz 6 n DRAWN BY: CR/ME CHECKED BY: ES MD PROJECT#: 18043 INTERIOR ELEVATIONS A601 SS-1 PL-3 4 SCALE: 11T =1W 2'-0" RECCEPTION INS SCALE: 112' =1'-a' 4 COPY ROOM ISLAND ELEVATION B 0 _RNMEN N 0" GLE ELEVATION :aTa1ph11q:7D79A94 3" MAXIMUM RADIUSED CORNERS, ALL CORNERS PL-2 3 COPY ROOM ISLAND ELEVATION A RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/06/19 SCALE: 11T =1W COPY AREA ISLAND SCALE: 112"=140" 1 1 1 HQIPIIq:7P7994: 3" MAXIMUM RADIUSED CORNERS, ALL CORNERS PL-2 COUNTERTOP; PL-1 Pt-2 r mitsch IDESIGN 200 s rangeline road suite 226 Carmel, indiana 46032 ph 317.573.2222 fx 317.573.2230 wwW.mitschdesign.mm Z Q J n W U Q co U) W 0� �O QO LL Z = O� G G W W M F— CD Cn CO Q Z OQ W Z J Z LLI O Q �0 No.uanaoaceo s*Area �,k w 8� m u au,mm - o KK ' q z3°OoG v 'uw ZW77 m m �Epia wZZ €oyoo rcrcoQ ,°-� aa¢y > 00 mNyw ozm po o 0 w3 owa 6 n z DRAWN BY: CRIME CHECKED BY: ES MD PROJECT#: 18043 INTERIOR ELEVATIONS A602 RELEASED FOR Subject to complier of State an City e DATE: 0 PLASTIC LAMINATE PLASTIC LAMINATE b HARDWARE ADJUSTABLE SHELF N HARDWARE SINK AND FAUCET — 2-O" V-0" TRANSACTION TOP 2-0" COUNTERTOP W/4" 2—O" COUNTERTOP BACKSPLASH COUNTERTOP W/4" AN04"BACKSPLASH COUMERTOP BACKSPLASH 2 _0. HARDWARE FALSE FRONT I I HARDWARE ADJUSTABLE SHELF CAVITY FOR / UNDERCOUNTER REI PLASTIC LAMINATE z� I I _ I I I I I I PLASTIC LAMINATE VINYL BASE b 4" BASE b 12 TYP SINK/UPPER SECTION 9 RECEPTION DESK DETAIL 3 6 TRASH CHUTE WITH UPPERS DETIAL 3 UNDERCOUTER REF. DETAIL SCALE: 314" =1'-0" SCALE: 314"=1'-0" SCALE: 314"=1'-0" SCALE: 314"= Vill 1d_3. ADJUSTABLE SHELF PLASTIC LAMINATE PLASTIC LAMINATE PLASTIC LAMINATE N V I HARDWARE N ADJUSTABLE SHELF ADJUSTABLE SHELF HARDWARE HARDWARE D u 2-0" COUNTERTOP W/4" BACKSPLASH d 2.0" 2'-6' 2'-0" 2—Oil COUNTERTOP Will COUNTERTOP W/4" COUNTERTOP COUNTERTOP W/4" BACKSPLASH BACKSPLASH BACKSPLASH PLASTIC LAMINATE r HARDWARE DRAWER CAVITY FOR DISHWASHER r - ---, IMPRINTER ON / ROLL OUT SHELF II ADJUSTABLE SHELF HARDWARE ini � ADJUSTABLE SHELF /// b PLASTIC LAMINATE i II PLASTIC LAMINATE I I U I 4" BASE 4" BASE 14 NORTH COPY ROOM ELEVATION C 11 BREAK ROOM ELEVATION A 8 RECEPTION DESK DETAIL 2 5 TYP UPPER AND BASE CAB DETAIL 2 TYP DRAWER/CAB DETAIL 314"=1'-0" SCALE: 314"=1'4" SCALE: 314"=Vill SCALE: 314"=Vill SCALE: SCALE: 314" Ti 1 _3. 1 ADJUSTABLE SHELF I II PLASTIC LAMINATE II I � HARDWARE p O. 2'-0" COUNTERTOP W/4" BACKSPLASH 11-0" TRANSACTION TOP 2'"6" 2'-0" COUNTERTOP W/4"BACKSPLASH 2-O. COUNTERTOP Wit 4" BACKSPLASH COUNTERTOP COUNTERTOP HARDWARE PLASTIC LAMINATE 2'-0' DRAWER p HARDWARE HARDWARE ADJUSTABLE SHELF wO ADJUSTABLE SHELF I I PLASTIC LAMINATE '° CONSTRUCTION PLASTIC LAMINATE DRAWERS O PLASTIC LAMINATE :e with all regulations 4" BASE 4" BASE;, 4" BASE I local Codes -,. � _ a Camel °^ RTH COPY ROOM ELEVATION B 10 RECEPTION DESK DETAIL 4 7 RECEPTION DESK DETAIL 4 FILE CABINET DETAIL 1 TRASH CHUTE DETAIL 3/06/19 E: 314"=III SCALE: 314"=1'-0" SCALE: 314"=1'-0" SCALE: 314"=III SCALE: 314"=Vill r mitsch IDESIGN 200 s rangeline road suite 226 cannel, indiana 46032 ph 317.573.2222 fx 317.573.2230 w✓✓ W. m itschdesign.com ra.annelgmo e*Area � npE N z PH% � pv 3 Ro ZV)7J U'ow t �ZZF Ezllwza wUo asOQN Al-°'02 - K i2�t;X0 gg m yy Sp i6wrc it II # iG h #Ra#R Z DRAWN BY: CRAZE CHECKED BY: ES MD PROJECTk: 18043 INTERIOR SECTIONS A603 FINISH SCHEDULE - PLAIN ROOM FINISH SCHEDULE NUMBER NAME WALL FINISH FLOOR FINISH BASE FINISH CEILING FINISH COMMENTS 184 MEDIUM OFFICE PT-1, PT CPT VB-1, VB-2 ACT 185 MEDIUM OFFICE PT-1, PT CPT VB-1, VB-2 ACT 186 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 187 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 188 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 189 MEDIUM OFFICE PT-1, PT CPT VB-1, VB-2 ACT-1 193 MEDIUM OFFICE PT-1, PT CPT VS-1, VS-2 ACT-1 194 MEDIUM OFFICE PT-1, PT CPT VS-1, VS-2 ACT-1 195 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 196 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 197 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 198 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-0 199 LARGE OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-0 210 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 211 MEDIUM OFFICE PT-1, PT CPT4 VB-1, VB-2 ACT4 213 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 215 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 227 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-7 230 CONFERENCE ROOM PT-1, PT-2, PT-3 CPT-1 VB-1, VB-2, VBJ ACT-1 231 LARGE OFFICE PT-1, PT-3 CPT-1 VB-1, VB-3 ACT-1 233 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 235 LARGE OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 238 STORAGE PT-1 VCT-1 VB-1 ACT-1 239 LARGE OFFICE PT-1, PT CPT-1 VB-1, VB-2 ACT-1 240 HUDDLE ROOM PT-1, PT CPT-1 VB-1, VB-3 ACT-1 241 MEDIUM OFFICE PT-1, PT CPT-1 VB-1, VB-2 ACT-1 242 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 243 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 244 COAT CLOSET PT-1, PT-2 VCT-1 VB-1, VB-2 ACT-1 245 LARGE OFFICE PT-1, PT-2 CPT-1 VB-1, VS-2 ACT-1 248 MEDIUM OFFICE PT-1, PT-2 CPT-1 VS-1, VB-2 ACT-1 249 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 250 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 251 HUDDLE ROOM PT-1, PT-3 CPT-1 VS-1, VS-3 ACT-1 252 MEDIUM OFFICE PT-1, PT CPT-1 VS-1, VS-2 ACT-1 253 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 264 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 255 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 256 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 257 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 258 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 259 LARGE OFFICE PT-1, PT-2 CPT4 VB-1, VB-2 ACT4 260 LARGE OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 262 MEDIUM OFFICE PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 264 CONFERENCE ROOM PT-1, PT-3 CPT-7 VB-1, VB-3 GYP 266 MOTHER'S ROOM PT-1 CPT-1 VB-1 ACT-1 267 LARGE OFFICE PT-1, PT-2 CPT4 VB-1, VB-2 ACT-0 268 LARGE OFFICE PT-1, PT-2 CPT4 VB-1, VB-2 ACT-0 269 BREAKROOM PT-1, PT-2, PT-3 -VT-1 VB-1, VB-2, VBJ ACT-1 270 SERVER PT-1 VCT-1 VB-1 ACT-1 271 HUDDLE PT-1, PT-3 CPT-1 VB-1, VB-3 ACT-1 272 COFFEE PT-1 -VT-1 VB-1 ACT-1 274 COPYROOM PT-1, PT-2 CPT-1 VB-1, VB-2 ACT-1 275 RECEPTION PT-1,PT-2, PT-3 T-2 WB-1 GYP 276 COPY AREA PT4,PT-2 CPT-1 VB-1,VB-2 ACT-0 277 CIRCULATION PT- -2 CPT-1 VB-1, VB-2 ACT-0 278 WOMEN'S RESTROO WC-1,WT-1, WT-2 T-1 WT-1 ACT-1 279 MENS RESTROOM WC-1,WT-1, T-2 T-1 WT-I ACT-1 280 MEDIUM OFFICE I RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/06/19 �- zL- WALL FINISH SCHEDULE CODE MATERIAL MANUFACTURER PATTERN/STYLE COLOR NUMBER COMMENTS PT4 PAINT SHERWIN WILLAIMS EGGSHELL INTELLECTUAL GRAY SW7045 GENERAL PAINT PT-2 PAIN WIL GG MOU ENT PA T NT LLA HEL EA T SW INT A;;E715l W -0 WA LCOVERIN D.L. P7D TOWER EXCEP ONAL VALUES 6 TOWER E CEPTIONAL VAL ES6 TEV- 13 1 LLT RTIL LO B LOSS F31 030NS TION; WITH GR-1 WT-2 WALLTILE A MOSAIC AR IGCON BISCU - FINISH CEILING SCHEDULE C RIAL U ATTE E OLO MBE COMMENTS 71 ACT-1 I ACOUSTIC CEILING TILE ARMSTRONG DUNE/SECOND LOOK FINISH FLOOR SCHEDULE CODE MATERIAL MANUFACTURER PATTERN/STYLE COLOR NUMBER COMMENTS CARPET SHAW ENTWINE WINCE INSTALL MONOLITHIC; CONTACT CORPORATE ACCOUNTREP, PAUL 91-1 go 3) 0 TILE ATLASCONCOR E PA WHITE 12X24 THE;USE WITH GR-1 LTT2 TILE DALTILE YACHT CLUB SEE ANCHOR YC04 BX24 TILE; USE WITH GR-2 VVI E SHAW HAZ V-03 OMIL ,18" STA LAR; ACT AA NTR AULCL ND13)760- VINYL COMPOSITION TILE ARMSTRONG RAFFIA SMOKE 55804 FINISH BASE SCHEDULE CODE MATERIAL MANUFACTURER PATTERN/STYLE COLOR NUMBER COMMENTS VB-1 VINYL BASE JOHNSONITE 4-COVE PEARL 22 USE WITH PT-1 VB-2 VINYL BASE JOHNSONITE 4-COVE GRIZZLEV 281 USE WITH PT-2 VB-3 VINYL BASE JOHNSONITE 4-COVE BLUE LAGOON 92 1 USE WITH PT-3 W BA WOOD BASE MATCH TO T-2 MATCH TO T-2 FINISH MILLWORK SCHEDULE CODE MATERIAL MANUFACTURER PATTERN/STYLE COLOR NUMBER COMMENTS PL-1 PLASTIC LAMINATE WILSONART LUNA FROST PL-2 PLASTIC LAMINATE WILSONART COCOBALA 7924 PLJ SNA FORMI BLACK 9-TU PLA IN MCAR 7 1 FIN PL-5 PE WART ILSONART - VETEAK 8209-28 T LET PART IONS SS-1 SOLID SURFACE VIATERA - EVEREST - TRANSACTION TOPS S -2 SO D SURFAA CORIAN QUARTZA A VAL TE PEAR R STROOM UNTERTCYPS GROUT SCHEDULE CODE MATERIAL MANUFACTURER PATTERWSTYLE COLOR NUMBER COMMENTS R-1 GROUT TEC - LIGHTPE R 927 l GR-2 GROUT TEC I ESPRESSO 1 958 FINISH DOOR SCHEDULE CODE [�ST-2 MATERIAL MANUFACTURER PATTERWSTYLE COLOR NUMBER COMMENTS ST-1 TO MATCH T-2 I TO MATCH PL-2 Ift mitsch DESIGN 200 s rangeline road suite 226 carmel, indiana 46032 ph 317.573.2222 fx 317.573.2230 www.m itschdesign. com Z J LU U O � a. O �/l V�U) LU LU LL (n LU r M Q O W LU N J F LLJ 0 ILL z ¢ C0 Z ¢z Z O aZ o �- C0 } - ZLu � w �U No.ABneoroeo sTArea w S opw o =wbw N Wr E„w S wmN¢ )FNm w 75 m>W> 23§0 ZN7m 2OKFK zu t m ms W W cau ¢ i45 ixoz 6o in $$QN R o zw �0$[_$$W S## O 0f N N Ow 0z o 0 0 giE w3 4U444 Q,pu <°9a Z N O DRAWN BY: CR/ME CHECKED BY: ES MD PROJECT#: 18043 INTERIOR ROOM FINISH SCHEDULE A700 1111111111 I� ELECTRICAL LEGEND GENERAL ELECTRICAL/DATA NOTES ALTERNATE PRICE- FLOORCORES IN HUDDLE ROOMS. 4D STANDARD DUPLEX RECEPTACLE STANDARD QUAD DUPLEX RECEPTACLE STANDARD DUPLEX RECEPTACLE (DEDICATED) G STANDARD RECEPTACLE(VOICE/DATA) Ox STANDARD FLOOR RECEPTACLE (POWER) ® STANDARD FLOOR RECEPTACLE (VOICE/DATA) GFI DENOTES GROUND FAULT INTERRUPTER N DENOTES ITEM FOR TENANT PROVIDED N +44 DENOTES CENTERLINE MOUNTING HEIGHT OF OUTLET/RECEPTACLE NOTE: ELECTICAL ITEMS FOR LOCATION PURPOSES ONLY. L I- FS��'1 1 [rjxJ'I V_ I: 1 _ Im �. • m � `� m • Of i��l ———— -- 1 ———— II owIaw IIt ICE- ®I I®I m m l®I®I®I®I m m I®I®I ®I®I®I®I SA ' SA ¢ SA SA c ] xEaux OFFICE Pq CON NECTTO 2' EXISTING VENT 3 TOEXISTING M ENS ESTROOD 4"EXISTING WOMENS RESTROOM SEWER LINE � '+ /^ DIW SINK V 99 4 2 2 PLUMBING RISER DIAGRAM RELEASED FOR CONSTRUCTION 'LEI NTS Subject to compliance with all regulations of State and meal Codes City of Camel �1�f6��FI�Fk6�R—EI DATE: 03/06/19 SCALE: 116'=f-Y' Ti r— SERVER L — �\Tx 9 IDS OFFICE �• \JI g9 0 03 .. 4�.. 8 02 9 vRW ORCE ID' \o aCm G IN I ZREAKR:OOM GFI GFI _4 ff SA SA 10 11 ..m 5 5 SA 12 A. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION. B. ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS AS INDICATED ON DRAWINGS OR AS REQUIRED BY TENANT. VERIFY ACTUAL REQUIREMENTS WITH DESIGNER PRIOR TO INSTALLATION. C. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT TELEPHONE/DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS MATERIAL AND LABOR) TO BE PROVIDED O THE TENANT UNLESS OTHERWISE NOTED. D. ELL TRICA CONTRACTY SYSTEMS R COORDINE PROVIDED BY ATE NANT ALL E ECTRICNLESS LAND OTHERWISE E. MILLWORK AND CONTRACTOR SHALL ITHCONTRACTOR AS ELECTRICAL CAL AND LIGHTING REQUIREMENTS FOR M ILLWOR KANDCABINETRYWITHCONTRACTOR E NECESSARY. F. ALL WALL MOUNTED OUTLET, UNLETOBEMOUNTED VERTICALLY AT TO MEET CODE REQUIREMENTS i0 CENTERLINE OF OUTLET, UNLESS OTHERWISE NOTED. G. SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE BUILDING STANDARDS COLOR. H. ALL OTHERWISE NOTED. WARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS, UNLESS OTHERWISE NOTED. I. DO NOT LOCATEBOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRE TO MINIMIZE SOUND TRANSMISSION. J. ADJACENT OUTLETS SHALL BEA CE BET WHEN IF THEY CANNOT BE GANGED, THEY SHALL BE INSTALL WITH A MIN. DISTANCE BETWEEN UNITS. K. CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE AND LOCAL BUILDING CODES. L. ELECTRICAL CONTRACTOR TO EMERGENCY LIGHTS TS AND WORKING CONDITION LACE IF NECESSARY. LIGHT FIXTURES, BALLASTS, EXIT AND EMERGENCY LIGHTS AND OUTLETS, REPLACE IF NECESSARY. DO CAL G DIM S Ei0 HER UN ETI CO NDITIO S EEM O HE WISE. ANV CON IC STHA AV EXIS H NE ON TION MUS BE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OR WORK O NOTCIRCUMVENT DIMENSIONS BYATTACHED RECEPTACLES TO NEAREST STUD. N. THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. O. ELECTRICAL/DATA OUTLET LOCATION TO BEVERIFIED WITH TENANT PRIOR TO ROUGH -IN. ALL LOCATIONSTO BEVERIFIED WITH FURNITURE PLACEMENT. P. SYSTEMS FURNITURE TO BE DRAWING ON FLOOR PRIOR TO PLACEMENT OF FLOOR CORE AND JUNCTION BOXES. DESIGNER TO APPROVE LOCATIONS PRIOR TO CORING/PLACEMENT. Q. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONNECTING DEALER PROVIDED FURNITURE SYSTEMS POWER IN-FEEDTOBUILDINGJ-BOX WHERE INDICATED PLAN. R. REUSE EXISTING DEVICEVICESS N WHERE POSSIBLE, UNLESS OTHERWISE NOTED. PROVIDE NEW AS REQUIRED TO MEET STANDARD QUANTITIES LISTED, AND i0 ACCOMMODATE FURNITURE AND EQUIPMENT SHOWN ON PLAN. S. ASSUME I.L CON DUITTO CONNECTFLOOROUTLET iONRCUIT. IN WALL. T. ELECTSTANDARD CON TENANT WORKSTATIONS REQUIRED. 4/1 CIRCUIT. V. DAN INCLUDNVENIEN RINGAND DA REQUIRED. V. CABLING AND DTERES MUD IONGAN PLAT TO IN THEWALLTHATEXTENDSABOVE THE CEILING. DATA CABLING AND TERMINATION TO A PLATE TO BE COORDINATED BY TENANT. «« ELECTRICAL/DATA KEYNOTES 01 DUPLEX RECEPTABLE LOCATED UNDER COUNTER 02 TENANT WORKSTATIONS,COORDINATE WITH FURNITURE PROVIDER ON POWER &DATA NEEDS. 03 N OUTLETS TO BE LOCATED AT 66'A.F.F, INCLUDE I POWER OUTLET, I HDMI OUTLETAND I COAX OUTLET 04 CONFERENCE ROOM FLOOR DUPLEX OUTLET TO INCLUDE DATA, VOICE AND HDMINGA INPUTS. 05 FOLLOW TENANT GUIDELINES FOR SERVER ROOM POWER CONSUMPTION O6 PROVIDE POWER,DATANOICE, AND HDMI AT 18' A.F.F. RIGHT BELOW N OUTLETS 0] PROVIDE POWER FOR CARD READER OB PROVIDE POWER FOR DOOR HARDWARE 09 CONTRACTOR TO COORDINATE WITH TENANT'S AV PROVIDER ON FLOORCORE CONNECTIONS 10 PROVIDE GROUND POST FROM BUILDING GROUND CONTRACTOR TO COORDINATE FLOORCORE WORK W/ LANDLORD FOR WORK DONE IN FLOOR 1I,QVf.PROYJ9E-CpNDIl17F0 MATCH OPEN TO DECK FINISH TO DISGUISE. BE IN THIS LOCATION. WM I® VAGE OFFICE _mllwl Ift mitsch DESIGN 200 s rangeline road suite 226 ca"el, Indiana 46032 ph 317.573.2222 fx 317.573.2230 www.m itschdesign,com Z Q J n W U QQ �1 O C0 V J F LU 10� U) C 0 w M Q p WN M � LL co 7 C0 Z z Q a Z O K0 O S G` W z 2 l^ 0 / J ? N2 �I CC G t LL rU LU +^OFWI . PF' fQ. €x ; No. M11iWLEU G, 'gR11CHI a Op3 WILL T�09 W i y wlzowot i� ot zn mN¢ ` �FW� — H>W> orcarc ado§$� z,WW,M v Ulu t w N mFwi C=C V W W W 00Q N= Q�LL aa¢ m Vis mew wz$Ozergw e o W itgg o00 Hicz g< gM3 6 z DRAWN BY CR/ME CHECKED BY ES MD PROJECT k: 18N3 ELECTRICAL/DATA PLAN AE101 MEDIUM OFFICE MEDIUM OFFICE 185 DIUM MEDIUM MEDIUM MEDIUM MEDIUM MEDIUM OFFICE 11 OFFICEOII 0FFICF188E II OF ICE 280 II OFFICEOI OFFICETTJ FEC MEDIUM Q OFFICE 1g aICE �\ 1 01 LIFE SAFETY PLAN SCALE: 3192" =1'-)" RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/06/19 --- +--------- vaICE OFFICE wa a \ CnNFFRENCE ROOM a ` O , MAXIMUM PATH OF EGRESS TRAVEL= 106' - 2" MAXIMUM PATH F EGRESS TRAVEL 133' - 3" 1-------- - TF aFrlcE O LARGE MEDIUM MEDIUM OFFICE OFFICE OFFICE D ccE1 xsa 12E71 MEDIUM OFFICE 315 mmum ARGF OFFICE OFF CF 156 Q MEDIUM OFFICE NEDIUN OFFICE A9 ENUM FFICE R11 LARGE MEDIUM MEDIUM MEDIUM OFFC OFFICE OFFICE OFFICE ® 254 p MEDIUM OFFICE 21311 MEDIUM OFFICE OFFICE OFFICE gas LIFE SAFETY LEGEND L�FEC FIRE EXTINGUISHER CABINET 0FEB FIRE EXTINGUISHER AND WALL BRACKET DENOTES DIRECTION OF EGRESS DENOTES 1-HR RATED WALL DENOTES 2-HR RATED WALL NOTE: COORDINATE FINAL FIRE EXTINGUISHER LOCATIONS WITH LOCAL FIRE CHIEF. CODE ANALYSIS 1. BUILDING CONSTRUCTION TYPE I-B 2. OCCUPANCY CLASSIFICATION B- BUSINESS 3. FIRE SUPPRESSION SYSTEM FULLY SPRINKLED 4. BUILDING HEIGHT 10 STORIES 5. BUILDING AREA (IBC TABLE 503) 23,459 SQUARE FEET (23,459 SF TOTAL) 6.00CUPANTLOAD AREA 23,459 SF FACTOR 100 = LOAD 235 7. PROPOSED USE OF FACILITY OFFICE 8. EXITS REQUIRED 2 9. RATED STORAGE ROOMS NO 10. RATED CORRIDORS NO (SPRINKLER SYSTEM) 11. OCCUPANCY SEPARATIONS REQUIRED NO 12. EXIT ACCESS TRAVEL DISTANCE LESS THAN ALLOWABLE 250'(FULLY SPRINKLED) LIFE SAFETY GENERAL NOTES A. RELOCATE/ADD SPRINKLER HEADS FOR NEW WALL LAYOUT TO MEET CODE REQUIREMENTS. B. TURN SPRIKLERS UP WHERE CEILING IS OPEN TO DECK, PER CODE. C. RELOCATE HORNS AND STROBES TO MEET CODE REQUIREMENTS. D. ADDITIONAL DEVICES TO BE INSTALLED BY BUILDING FIRE LIFE SAFETY VENDOR(KOORSEN). E. FIRE EXTINGUISHERS TO BE PROVIDED BY TENANT. F. INSTALL REQUIRED QUANTITY, PER CODE, OF INSET FIRE EXTINGUISHER CABINETS WITH ALUMINUM TRIM. APPLICABLE CODES CODE DESCRIPTION COMPRISED OF GENERAL ADMINISTRATION RULES GENERAL ADMINISTRATION RULES 675 IAC 12 (GAR) (UPDATED 08.01.2014) (AMENDED 12.01.2014) 2012 INTERNATIONAL BUILDING CODE 2014 INDIANA BUILDING CODE (INDIANA AMENDMENTS) (675 IAC 13-2.6) EFFECTIVE BUILDING CODE 675 IAC 12.01.2014 13-2.6 FIRE CODE 2014 INDIANA FIRE CODE (IFC) 2012 INTERNATIONAL FIRE CODE (INDIANA AMENDMENTS) EFFECTIVE 12.01.2014 675 IAC 22-2.5 PLUMBING CODE 2012 INDIANA PLUMBING CODE (IPC) 2006 INTERNATIONAL PLUMBING (INDIANA AMENDMENTS) EFFECTIVE 12.24.2012 CODE 675 IAC 16-1.4 ELECTRICAL CODE 2009 INDIANA ELECTRICAL 2008 NFPA 70675IAC 17-1.8 (INDIANA AMENDMENTS) CODE(IEC) EFFECTIVE 08.26.2009 MECHANICAL CODE 2014 INDIANA MECHANICAL 2012 INTERNATIONAL (INDIANA AMENDMENTS) CODE (675IAC 18-1.6)EFFECTIVE MECHANICAL CODE 676 LAC 18-1.6 12.01.2014 HANDICAP ACCESSIBILITY CODE 2008 INDIANA BUILDING CODE 6761AC 13-2.5-12 CHAPTER II (INDIANA AMENDMENTS) CHAPTER 11 ACCESSIBILITY ENERGYCODE 2010 INDIANA ENERGY ASHRAE STANDARD 90.1, 2007 LAC (INDIANA AMENDMENTS) CONSERVATION CODE (IECC) 19-4 EFFECTIVE 05.07.2010 ELEVATOR SAFETY CODE 2011 INDIANA ELEVATOR SAFETY 675 LAC 21 -ANSI/ASMEA17.1,2007 CODE CONSERVATION CODE ANSI/ASME A90.1,2003 (IESC) (UPDATED 09.28.2011) ANSI/A10.4, 2004 ASME/ A18.1, 2005 r mitsch IDI-SIGN 200 s rangeline road suite 226 carmel, Indiana 46032 ph 317.573.2222 fx 317.573.2230 wW Anitschdesign.corn Z Q /J1 I . LU Q^ LL o O Ffl IL 1�r' Q Q r LU M 0 J W cN,1 F-(COD W LL a z = z aZ C z O EEOn O LU ZjjU C LQ �0 W �$ at 6\STfq �k w 00 xw O N Q O W W m 2o�w'Fw m <j Z050 D �i 3ii0% i"FLE U' C OI �zWW y KKOF aa¢ur - v ow .. jaw 4m< Crc3 Az DRAWN BY: CR/ME CHECKED BY: ES MD PROJECT#: 18043 SAFETY PLAN LIFE G001 NO. SIZE DOOR FRAME A HARDW ARE REMARKS MADEfHGT F T Y P E FINIS N RTG FIN N RTG TY P E FINI SH 412 3'-0" 6'-0" 0'-13/4" 3 ST-1 NR ST-1 NR 420 3'-0" 8'-0" 0'-13/4' 1 ST-2 NR 2 AL TONE NR 1 B.S. 421 T-0" 8'-0" 0'-13/4" 1 ST-2 NR 1 ALUMATONE NR 1 B.S. 423 T-0" 8'-0" 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 424 T-0" 8'-0" 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 425 X-0" 8'-0" 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR Ill B.S. 426 X-0' 8'-0" 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 427 T-D' 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 430 T- 0- 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 431 T.0' 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 432 T-0' 8'-0' 0'-13/4' 1 ST-2 INR 12 ALUMATONE NR 1 B.S. 433 X-0" 8'-0" 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 434 X-0" 8'-0" 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 435 T-V 8'-0" 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 443 X-0" 8'-0" 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 444 X-0" 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 445 T- IT 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 446 T-V 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUIii NR 1 B.S. 447 3'-V 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 448 T-V 8'-0' 0'. 13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 449 T-0" 8'-0" 0'-13/4' 1 ST-2 NR 1 ALUMATONE NR 1 B.S. 459 T-0" 8'-0" 0'-13/4' 1 ST-2 NR 1 ALUMATONE NR 1 B.S. PROVIDE CLOSER AND KICKSTAND 1" X 539'WOOD CAP FINISH AND SPECIES AS SPECIFIED, EASE ALL EDGES SEALL JOIN BETWEEN WOOD CAP AND DRYWALL WOOD NAIL BOARD FOR TOP CAP 3 SIT METAL STUDS, IT O.C. WITH 59' BASE- SEE SCHEDULE FOR SPECIFICATIONS FLOORLINE 4 S4.40 PARTIAL HEIGHT WALL SCALE: W = T-T ADD TRANSFER DUCT FOR RETURN AIR CEILING AS SCHEDULED, F REFLECTED CEILING PLAN 3 51METAL STUDS, 1TO.C. WITH 56' GYPSUM BOARD BOTH SIDES INSULATION IN WALL CAVITY _r: BASE- SEE SCHEDULE FOR SPECIFICATIONS CONTINUOUS ACOUSTICAL SEALANT FLOORLINE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/06/19 iDECK(INSULATED) NO. SIZE DOOR FRAME HARDW ARE 1 REM WIDE NGT THICK T Y P E FINIS H RTG TY PE FINISH RTG TY PE FINI SH 4]6 3'-0" 6'-0" 0'-13/4" 1 ST-2 NR 2 ALUMATONE NR 2 B.S. 483 T-0" 8'-D' U-13/4' 1 ST-2 NR 1 ALUMATONE NR 1 B.S. DE CLOSER 489 3'-0" 8'-W U-13/4" 1 ST-2 NR 1 ALUMATONE NR 3 6.5. SCHLAGE CO-100.CV-]D-KP-RH043D 491 T-0" 8'-V 0'-13/4" 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 498 T-0" 8'-V 0'-13/4" 1 ST-2 NR 1 ALUMAJi NR 4 B.S. 499 3'-0" 6'-0" 0'-13/4' 1 ST-2 NR 1 ALUMATONE NR 3 B.S. 502 T-0" 8'-0" 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 505 T-D' 8'-0' U-13/4' 2 ST-2 NR 4 ALUMATONE NR 2 B.S. HARDWARE FOR DOUBLE DOOR 507 3'-0' 8- - W 0'-13/4" 1 ST-2 NR 1 ALUMATONE NR 1 B.S. PROVIDE CLOSER 510 3'-W 8'-W U-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 512 X-0' 8'-0' 0-13/4' 1 ST-2 NR 2 ALUMATONE NR B.S. 1 513 X-0" 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 2 514 X-0" 8'-0" 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 2 S. 515 3'-0" 8'-V Y-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 517 X-0" 8'-0" 0'-13/4' 1 ST-2 NR 1 ALUMATONE NR 1 B.S. PROVIDE CLOSER 518 X-0" 8'-0' 0'-13/4' 3 ST-1 NR 3 ST-1 NR 5 B.S. 519 T-0" 8'-P 0'-13/4' 1 ST-2 NR 1 ALUMATONE NR 1 B.S. 522 T-0" 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 523 V-0" 8'-0' 0'-13/4' 1 ST-2 NR 1 ALUMATONE NR 1 B.S. 525 X-0" 8'.0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 526 T-0" 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 527 IT- 0- 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 528 IT- 0- 8'-0' 0'-13/4' 1 ST-2 NR 2 ALUMATONE NR 1 B.S. NEW OR EXISTING WINDOW MULLION BLACK NEOPRENE SEALADHEARED TO FACE OF MULLION AND SILL CAP ATALL EXPOSED SURFACES ADJACENT TO ALUMINUM CHANNEL ALUMINUM BRAKE METAL CHANNEL W ITH EDGES RETURNED (COLOR TO MATCH WINDOW FRAMING SYSTEM) SILL BELOW - FIELD VERIFY EXACT LOCATION WALL CONSTRUCTION CENTERED ON WINDOW MULLION NOTE: PROVIDE TIGHT FIT WHERE WALL IS COPED AROUND ANY WINDOW SILL CONSTRUCTION. 2 PARTITION TO MULLION DETAIL SCALE: 314" =1'-0" UNDERSIDE OF SLAB OR STRUCTURE MOVE CEILING AS SCHEDULED, REFER TO REFLECTED CEILING PLAN 3 59" METAL STUDS, 1T O.C. WITH 518" GYPSUM BOARD BOTH SIDES INSULATION IN WALL CAVITY BASE- SEE SCHEDULE FOR SPECIFICA CONTINUOUS ACOUSTICAL SEALANT FLOOR LINE S4.10 PARTITION TO CEILING (INSULATED) SCALE: 314" =1T' NO. SIZEJ3/41 DOOR FRAME HARDIN ARE REMARKS WIDE HGT TH T Y P E FINIS RTG TY PE FINISH RTG TY PE FINI SH -0" 0'-1 ST-2 NR 2 ALUMATONE NR 1 6.5. 530 T-IT 8'-0" 0'-1 ST-2 NR 2 ALUMATONE NR 1 B.S. 531 T-V 8'-0" V-1 ST-2 NR 2 ALUMATONE NR 1 B.S. 532 T-V 8'-0" 0'-1 ST-2 NR 2 ALUMATONE NR 1 B.S. 533 T-V 8'-0" 0'-1 ST-2 NR 2 ALUMATONE NR 1 B.S. 534 X-0" 8'-0" U-1 ST-2 NR 2 ALUMATONE NR 1 B.S. 535 3'-T 8'-0" U- 1 ST-2 NR 1 ALUMATONE NR 2 6.5. 536 T-O" 8'-0" 0'- 1 ST-2 NR 2 ALUMATONE NR 1 B.S. 537 3'-0" 8'-0" 0'-1 ST-2 NR 2 ALUMATONE NR 1 B.S. 538 3'-0" 8'-0" Y-1 61-2 NR 1 ALUMATQNE NR 1 B.S. DOOR NOTES A. MATCH EXISTING DOOR MATERIAL IN SPECIES, 8 HARDWARE; REFER TO FINISH LEGEND FOR STAIN DETAILS. Ift B. TIMELY FRAMES TO BE TA-28 ALUMINUM CASING WITH NO REVEAL, ALUMATONE FINISH ALL C. ALL DOOR HARDWARE TO BE LEVER STYLE BUILDING STANDARD. 0. ALL GLASS KITS IN W000 DOORS TO BE 1/4' TEMPERED GLASS. TRIMS TO BE STAINED TO MATCH DOOR, SQUARE PROFILE. FILL NAIL HOLES WITH MATCHING STAINABLE FILLER. E. ALL DOORS TO HAVE FLOOR STOPS. F. ALL O T HAVE TO MUTES. DOORS O U S G. ALL OFFICE DOORS TO RECEIVE COAT HOOKS PROVIDED BY LANDLORD. GC TO INSTALL. H. ALL DOORS TO HAVE DOOR LOCKS 8 PASSAGE SETS PROVIDED 8 KEYED BY LANDLOAD. HINGES 8 DOORSRABY GC. HAI I. DOOR HARDWARE RE8CONNECTIONS FOR SECURITY ACCESS FOR LOCKS AND STRIKE LOCKS NOT INCLUDED. HOWEVER, GC TO PROVIDE ELECTRICAL CON NECTION IF NECESSARY. ESSARY. [DESIGN 200 s rangeline road DEMOLITION NOTES suite 226 carmel, Indiana 46032 A. THE GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND ph 317.573.2222 TEMPORARY DOORS AS INDICATED ON THIS DEMOLITION PLAN, ORAS DEEMED NECESSARY fX 317.573.2230 BY THE ARCHITECT AND OWNER. THEY SHALL BE MAINTAINED AND REPAIRED IMMEDIATELY IF ANY DAMAGE OCCURS. THESE DOOR ARE TO AVOID MIGRATION OF DUST INTO THE ADJOINING AREAS. WW W.Inllschdaslgn.COln B. GENERAL CONTRACTOR TO VERIFY DUCTWORK OR PIPING PENETRATIONS THROUGH WALLS ABOVE CEILING. IF PENETRATIONS OCCUR AND DUCTWORK OR PIPING IS TO BE REMOVED OR RELOCATED, FILL IN OPENINGS TO BE FLUSH WITH AND OF THE SAME MATERIAL AS THE SURROUNDING WALL. C. MAKE ALL DEMOLITION CLEAN AND COMPLETE IN A MANNER SUITABLE TO ACCEPT NEW .. . SPECIFIED FINISHES AND OR SURFACES. REFER TO ARCHITECTURAL PLANS, SPECIFICATIONS, AND DETAILS FOR SPECIFIC INFORMATION REGARDING APPLICATION OF NEW MATERIAL. ARCHITECTURAL NOTES A. ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS AND STANDARDS, INCLUDING, BUT NOT LIMITED TO: THE INDIANA BUILDING CODE, THE INDIANA CODES, THE INDIANA FIRE CODES, THE AMERICANS WITH DISABILITIES ACT (ADA), INTERNATIONAL BUILDING CODE, AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS. B. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR TO BIDDING Al THE START OF WORK. REPORTANY DISCREPANCIES TO THE ARCHITECT/DESIGNER 8 OWNER IMMEDIATELY. C. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALLSTATE AND LOCAL PERMITS REQUIRED FOR COMPLETION OF THIS PROJECT. J D. ALL WORK IS TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE /'� ADEQUATE FIT, FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, LL INCLUDING SERVICE REQUIREMENTS OF THE OWNERS F.F.E. E. ALL DIMENSIONS ARE SHOWN ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED WITH THE ARCHITECT/DESIGNER. DO UJ NOT SCALE DIMENSIONS ON THE DRAWINGS. ALL DIMENSIONS ARE TO THE FACE OF ! , EXISTING GYPSUM BOARD, PROPOSED CENTER OF WALL, MASONRY/CONCRETE WALLS, V OR CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE. F. CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTAL THAT HAS BEEN REVIEWED, O APPROVED, AND THE CONTRACTOR COORDINATION HAS BEEN PERFORMED. rl C:)G. DURING THE ENTIRE PERIOD OF CONSTRUCTION, ALL EXISTING EXITS, EXIT LIGHTING, LL DJ FIRE PROTECTIVE DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED. (/� ! /� LL3 H. FINISHED DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET 4"FROM ADJACENT V/ VJ F PERPENDICULAR PARTITIONS, UNLESS OTHERWISE NOTED. I. ALL FINISH CARPENTRY IS TO BE COMPLETED IN STRICT ACCORDANCE WITH A.W.I. Of) STANDARDS, PREMIUM GRADE. C J. ALL FIRE EXTINGUISHER CABINET LOCATIONS ARE TO BE COORDINATED WITH THE C0 co CONTRACTOR, DESIGNER AND THE LOCAL FIRE OFFICIALS PRIOR TO INSTALLATION. LU K. CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS, AND EQUIPMENT < O LU N FOR THE WORK IN THESE DOCUMENTS, UNLESS CLEARLY NOTED'NOT IN CONTRACT' IY MO (N.I.C.).EXISTING WORK ADJACENT TO OR IN THE AREA OF NEW WORK SHALL BE J F PROTECTED BY ALL SUITABLE MEANS NECESSARY TO PREVENT OR MINIMIZE DAMAGE. Q Cn� WHERE EXISTING WORK IS TO BE REMOVED OR ALTERED, RESTORE ADJACENT FINISH U. TO ORIGINAL CONDITION. EXTEND/REFINISH ALL FRAMES, BASE, AND TRIM WHERE Q Z DOOR TYPES CUTTING HAS EXPOSED ANY UNFINISHED SURFACES. REPAIR ANY DAMAGE TO EXISTING WORK AND RESTORE TO ORIGINAL CONDITION. 0 Q L. CONTRACTORS SHALL KEEP WORKAREASAND ADJACENT PUBLIC CORRIDORSAND O a'� O FACILITIES FREE OF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITY OF LU Z -� THE CONTRACTOR AND SHALL BE STORED IN A LOCATION APPROVED BY THE LY V �/) SEE SCHED SEE SCHED SEE SCHED LANDLORD. J — I�— I� �'I I'• �'1 M. ALL PLUMBING ITEMS AND/OR EQUIPMENT ITEMS ARE TO BE COORDINATED AND } C Z W VERIFIED WITH INTERIOR ELEVATIONS PRIOR TO ROUGH -IN. ANY DISCREPANCIES G �a / O SHALL BE COORDINATED WITH THE DESIGNER. L w i i i N. COORDINATED WITH OWNER AND FACILITY STAFF PROJECT PHASING TO MINIMIZE /A/ C y m m DISRUPTION OF EXISTING FACILITY SERVICES. PHASING TO INCLUDE ASSURANCE FOR LJ_ C 6LL w w w CLEAN AIRFLOW, WRITTEN NOTIFICATION OF INTERRUPTIONS, AND COMMUNICATION y m m AUTHORITY. CONTRACTOR,OWNER, AND FACILITY STAFF TO PLAN FOR PROCEDURES ON THE EFFECTS OF NOISE AND VIBRATION ON HUMAN HEALTH AND SAFETY. THE RENOVATED AREAS SHALL BE ISOLATED FROM THE OCCUPIED AREAS DURING ALL TYPE #1 TYPE #2 TYPE #3 PHASES OF CONSTRUCTION USING AIRTIGHT BARRIERS, AND EXHAUST AIR FLOW SHALL SOLID WOOD SOLID WOOD SOLID WOOD BE SUFFICIENT TO MAINTAIN NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE. DOOR PAIR DOOR PAIR DOOR W/GLASS O. SUBMITTHE PLUS ONE E NUMBER OFORDE SUBMITTALS DESIGNERS RECORD ER REVIEW AND 1' ,pp,6tsTEREQ APPROVAL PLUS ONE EXTRA COPY FOR DESIGNERS RECORDS. FRAME TYPES REFLECTED CEILING NOTES SEE�y 4'-0" SEE SCHED SEE SCHED SEE SCHED a� A. PROVIDE FIRE DAMPERS AT FIRE -RATED PARTITIONS AS REQUIRED PER APPLICABLE BUILDING CODES. w w w w B INSTALLEDCEILING IN ALLAREAS SHALL BE CODES.STRICTACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, AND ALL APPLICABLE BUILDING •" . hU C. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DUCTWORK, SUPPLY AND o as RETURN AIR AND THERMOSTATS. COORDINATE ALL ELEMENTS OF THE HVAC SYSTEM TO w w w w PROVIDE A COMPLETELY BALANCED AND EFFICIENT HEATING AND COOLING SYSTEM. m m w m D. HVAC THERMOSTAT CONTROL FOR ALL ROOMS SHALL BE LOCATED WITHIN DEMISED SUITE.I [7 U ipo m o r ¢ 4 VERIFY AND REWORK EXISTING DUCTWORK AND THERMOSTATS AS REQUIRED. ° $ a TYPE #1 TYPE #2 TYPE #3 rypE #q E. MECHANICAL CONTRACTOR SHALL VERIFY WORKING CONDITION OF ALL EXITING w' 8w y w k w 'c0 HOLLOW METAL SIDELITE GLASS SOLID WOOD HOLLOW METAL THERMOSTATS, VAV BOXES, EXHAUST FANS, AND ANY OTHER DEVICE DIRECTLY RELATED TO �"� c'� r y - TO DOUBLE DOOR THE HVAC SYSTEM. CONTRACTOR TO NOTIFY ENGINEER/DESIGNER IMMEDIATELY UPON zoom"' ¢w2c oof DOUBLE DOOR -3 §86 ZODD $ BE1/4'CLEAR DISCOVERY OF DEFECTIVE DEVICE. �tp€J �00w TEMP. yEwi U r p�off KKOH w m� bon n-iii C > or HARDWARE LEGEND n m 91 PASSAGE LATCH Ai ENTRV/EXIT OR #3 STORAGE #4 PRIVACY LOCKSET #5 DOUBLE BAR ELECTRICAL NOTES a&a83rca 6_ OFFICE LOCKSET 1 LEVER HANDLE 1 STORAGE 1 PRIVACY LOCKSET WI OCCUPANCY 2 BAR PULLS .. . PASSAGE LATCH SET 1 LEVER HANDLE LOCKSET INDICATOR, VIZILOK PRIVACY LOCKING HANDLE SET 1 DOORSTOP (ALL OFFICE LOCKSET 1 CLOSER INDICATOR LOCK AND LEVER OR 2 CONCEALED A. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIALS, OFFICES) 1 DOOR STOP 1 DOOR STOP EQUAL, SATIN NICKEL C5FN CLOSERS EQUIPMENT, AND CONTRACTORS SERVICES NECESSARY TO COMPLETE INSTALLATION OF 3 SILENCERS 3 SILENCERS 3 SILENCERS 1 CLOSER HOLD OPEN HINGES SYSTEMS REQUIRED IN FULL CONFORMITY W ITH APPLICABLE CODES AND ORDINANCES. THE DRAWN BY CRIME 1 DOOR STOP FINISHED JOB SHALL BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND 3 SILENCERS ALL SUCH ITEMS FOR A COMPLETE SYSTEM. CHECKED BY ES B. ALL MATERIALS AND WORKMANSHIP SHALL MEETALL APPLICABLE STATE AND LOCAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY ACCEPTED CODES AND MD PROJECT#: 18043 GLASS TYPE STANDARDS. THE ELECTRICAL CONTRACTOR WILL BEAR ALL COSTS ARISING IN #6 ELECTRIC STRIKE CORRECTING ANY NON COMPLIANCE WITH THE REQUIREMENTS OF APPLICABLE CODES. C. CONTRACTOR TO SUPPLY AND INSTALL ALL JUNCTION BOXTOINDIVIDUALWORKSTATIONUNITSCCONTAL IRACTORTOSUPPLY PLENURING, INCLUDING RUNS OM GENERAL NOTES AND 1 STORAGE LOCKSET RATED BOXES AND PULLS AS REQUIRED TO ACCOMMODATE TENANTS TELEPHONE, DATA 2 CARDRDREADERS & pp GL-1: 1"INSULATED, CLEAR 2CAND SECURITY DEVICES. WALL DOOR TYPES READERS GL-2: 1/4' INTERIOR, CLEAR 3 SILENCERS 1 ELECTRIC STRIKE GL-3: 1/4" INTERIOR, CLEAR, TEMPERED G002 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/06/19 a AR IN 1 b 118"MIN. 12't305)'`d`a -0 \ 6(9M5) r� \ 42'MIN. SI M�) \ a IIMIN 1115) 1954) z "t a \ r--L= \ (C) HINGE APPROACH, PULL SIDE (D) HINGE APPROACH, PULL SIDE \ (A) FRONTAPPROACH, PULL SIDE (B) FRONTAPPROACH, PUSH SIDE FIG. 404.2.4.1 (E) HINGE APPROACH, PUSH SIDE (F) LATCH APPROACH, PULL SIDE MANEUVERING CLEARANCE AT SWINGING DOORS CLEAR FLOOR SPACE 60"MIN1 M5 (1 szs) ()) h zia I �� ��3 _ I- 12"MIN 6"MIN. 0. (305) (915) (3(3U5)5) � z $— L J IVI 30"MIN.. 48"MIN 36"MIN. 60"MIN (760)1 (1220) '� (915) '� _(1525)� (A) FORWARD (B) PARALLEL (A)CIRCULAR (B)T-SHAPED FIG 3043 FIG 405.5 SIZE OF WHEELCHAIR TURNING SPACE POSITION OF CLEAR FLOOR OR GROUND SPACE COMMUNICATION ELEMENTS & FEATURES (A) FORWARD APPROACH (B) PARALLEL APPROACH FIG 3057 MANEUVERING CLEARANCE IN AN ALCOVE CEILING�CEILINGbm F) � o A NM A �S iZO 0o Z R z o �wWo U- FLOOR OR GROUND FLOOR OR GROUND 15' MA% I, 50'-100' S0'-100' I, �15' MAX. (A) WALL ALAW6) WALL ALARM WITH (4570)'r—T(15-30m) (15-30m4-4(45]0) SMOKE DETECTOR FIG 702.3.5.1 FIG. 702.3.31 FIG. 7023.32 APPLIANCE SPACING IN CORRIDORS LOCATION OF WALL -MOUNTED APPLIANLOCATION OF CEILING- MOUNTED APPLIANCES 8' MIN f. (205) 1(2 0)N. N 1 ]"(COO)). I, I, FIG 3063 FIG. 30602 KNEECLEARANCE TOE CLEARAP LIBRPAV FIG 7032.4.4 CHARACTER HEIGHT L IL J ye I, �18" MIN. 7(455) FIG. 703 2 8 MOUNTING LOCATION AT DOORS PLUMBING ELEMENTS AND FACILITIES 12'max 54 42"min E 36'min (915) 31/2" max. *36" (915)mm MII 24" min. (90) f WHEN thin) 5"max. .15"max. p, WALL SPACE -(125) 136n) . PERhTRANSF r ER� Ee 16"-15" L �fA (405-455) LL11 � L__L__ 39"-41" (A) PARALLEL APPROACH (B) FORWARD APPROACH 60"min. p 525) FIG. 604.4/604.5.1 FIG 60452 FIG 6025 DRINKING FOUNTAN SPOUT LOCATION ACCESSIBLE ROUTES 24"max 481min 24"max. (1220)_rT(610) �s E� E� �z FIG 403.5 CLEAR WI DTH OF AN ACCESSIBLE ROUTE FIG. 604 2/604 3 1 WATER CLOSET LOCATION/ SIZE CLEARANCE IL ft xv FIG 403.5.1 CLEAR WIDTH ATTURN HEIGHT OF WATER CLOSET/ REAR WALL GRAB BAR FOR WATER CLOSET SIDE WALL GRAB BAR FOR WATER CLOSET I�y332' min 'I (815) t2-min 5) 96 (B) SLIDING DOOR i 2" min. (A) HINGED DOOR (815) a— (C) FOLDING DOOR FIG 40423 CLEAR WIDTH OF DOORWAYS --- 4" 61 u) �o (G) LATCH APPROACH, PUSH SIDE t48" MIN 48" MIN (1220) '� (1220)'� P===p ,� L (A) (B) FIG 404.2.6 TWO DOORS IN A SERIES FIG 307 4 REDUCED VERTICAL CLEARANCE (100) 0 � R x x 12" 12" x Zc, x Z5 (305) (305) FIG 307,2 LIMITS OF PROTRUDING OBJECTS FIG 6047 (A) WALLHUNGWATER CLOSET DISPENSER LOCATION y 54"MIN (1370) Fa-1 t --- I t �_ F----, I=_� d zN zN a 24" MIN (A) FRONT APPROACH (B) POCKET OR HINGE APPROACH (C) STOP OR LATCH APPROACH FIG 40424.2 MANEUVERING CLEARANCE AT SLIDING AND FOLDING DOORS REACH RANGES Z' 3 2(5 MA%. �i (510) (510-635) (255) (610) FIG. 308.,71 FIG. 308.2.2 FIG, 308.3A FIG. 308.3.2 UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTEEOBSTRUCTED HIGH SIDE REACH PROTRUDING OBJECTS FIG 3073 POST -MOUNTED PROTRUDING OBJECTS (B) FLOORMOUNTEDWATER CLOSET FIG 604811 FIG 60483 FIG 6063 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS TOILET COMPARTMENT DOORS HEIGHT OF LAVATORIES AND SINKS r mitsch DESIGN 200 s rangeline road suite 226 camlel, Indiana 46032 ph 317.573.2222 fx 317.573.2230 v Ww.mitschdesign.com LLJ Q LL LU ^U I . lc. O J LL 1 fC— G �k 5�omtQ � pJEW WE0 W o ¢Ro 0 ga8°we < DRAWN BY: CHECKED BY: MD PROJECT#: w W N F M F- O rn V Q Z � Q � O W z ZW (D Q �U No. M1t6W9ee e*Area w w a o m w c of w ZNDD azi t EJ ca0WW y W UOQ o > It I O CR/ME ES 18043 M rLJ VJ Z O ACCESSIBILITY DETAILS G003 I I I I I I I I L_J U 1 L 111 {� XiIlI��03 IIL 03 �TII 03 ��, ,�\ ,�\ \ L___�❑/ ^II O I 03 II 11111 II I11 II II II 01 �❑1=4❑�III� 3 II1I �II1 03 OC — 02 02 JI 03 �_—__C_______, O IL - ❑�} ❑� �03 II 03 II 03 \\\ 07 F �I II I�o3 Il \\ / li �_U II ❑ iT11 01 rF /vm IL JL 0TT7 JL _ r_ \ 03� /// `03 �03 i01 0J61�J/ 01 I I I F—�� I 0 i 01 Ed / 0 � 3 6— r 03 a 01 01 C — 03 � % F \\ \ 9 \ �v 03 II �X� m A 03 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/06/19 Tol DEMOLITION LEGEND - EiiiiiiiiiiE — — = EXISTING WALL OR ITEM TO BE REMOVED COMPLETE — EXISTING WALL OR ITEM TO REMAIN GENERAL DEMOLITION NOTES A. ALL DEMOLITION ITEMS SHALL BE CONSIDERED PROPERTY OF THE OWNER UNTIL SUCH TIME VERIFICATION HAS BEEN MADE AS TO ITEMS NOT TO BE RETAINED BY THE OWNER PRIOR TO REMOVAL FROM THE SITE. ALL ITEMS NOT TO BE RETAINED SHALL BE REMOVED COMPLETELY FROM THE SITE BY THE GENERAL CONTRACTOR. B. ANY ABANDONED ELECTRICAL OR COMMUNICATIONS BOXES REMAINING IN WALLS TO BE REMOVED & INFILLED. C. REMOVE UNUSED PLUMBING LINES & CAP AT SOURCE. D. DEMOLISH EXISTING DATA CABLING IN PLUNUM. E. DEMOLISH ALL EXCESS ELECTRICAL, DUCTING, LOW VOLTAGE WIRING NO LONGER IN USE; REMOVE EXISTING FLOOR & WALL FINISHES, PREP SURFACECS TO RECEIVE NEW FINISHES. F. EXISTING WINDOW BLINDS TO BE REMOVED AND SENT OUT FOR CLEANING. EXISTING BLINDS WILL BE REINSTALLED IN CONSTRUCTION. G. CONTRACTOR TO VERIFY ALL CASEWORK AND PLUMBING LOCATIONS; INCLUDE IN DEMOLITION. H. REMOVE AND REPLACE ANY DAMAGED WINDOW SILLS. I. COIL AND BAG THERMOSTATS ABOVE CEILING DURING CONSTRUCTION. J. ANY "T'S" TO BE REPLACED THAT ARE DAMAGED, MAINS TO BE CAULKED ® DEMOLITION KEYNOTES 01 REMOVE DOOR & FRAME COMPLETE 02 DEMOLISH ALL EXCESS ELECTRICAL, DUCTING, LOW VOLTAGE WIRING NO LONGER IN USE. REMOVE EXISTING FLOOR& WALL FINISHED, PREP SURFACES TO RECEIVE NEW FINISHES. 03 REMOVE WALL COMPLETE 04 REMOVE CASEWORK COMPLETE O5 REMOVE MOBILE PARTITION AND TRACK COMPLETE O6 REMOVE FLOOR, WALL FINISHES, TOILET PARTITIONS, COUNTERTOPS, SINK&FAUCETS, MIRRORS, ACT TILE, AND LIGHTING IN THEIR ENTIRETY IN THIS LOCATION; TOILETS, URINAL, AND ACT GRID TO REMAIN. \� LL 03 /%��07,1A 03 \\\\ \ \\ /> F �'e t 03 ( ^\ 01 r 01 / _iL--------_��_�\��/__—----_� ----------- // u1 N - los �03 fT 02 ------------ 03 JII—__�__ 11 II II II II II ---fir —, II II II I l j1 02 11� 11 II it 11 1l 11 11� p3 1I i 03 11 IC�I,, 1l 03 II 1 03 11 0a IL--- I� II IIe-� II ® /T IIF II 03 II �C,�-03 11�03 11 03 m 11 Jill \ 11 / 11 111 L= JL=----_—_ --``— \\ ❑ L ____ 01--JL _� 01--�L ``O�J��03 ❑ `03 \\`�_ 01 O01❑�L---Jr — 1 ❑ /!• II�I-Idll/ -q;;\ 03 p \�� i o1 —� II TE li// Oa 11� 11 ii li gill / \\ 11 II II 1�03 II Os II � 11i 1"03 1"03 ll`03 11 01 DEMOLITION PLAN SCALE: 118" =1'-U' 0 J Iiiiiiiiin mitsch IDESIGN 200 s rangeline road suite 226 ca"el, Indiana 46032 ph 317.573.2222 fx 317.573.2230 www.m itschdesign. com LLI M o mom S�gmi2Q iEwI> MRM WMOQOQ y0m�MEw a AWE <ia erc3 DRAWN BY: CHECKED BY: MD PROJECT#: W W N � M �o U) O V QZ pQ LL W Z J Z W O < Q �U rao.cnnemmo e*Area w w w a o 0 uc� c OZ is WWw RO 0 dRQv~ 'S CRRAE ES 18043 DEMOLITION PLAN D101 REFLECTED CEILING DEMOLITION LEGEND ALTERNATE PRICE: DEMO/REMOVAL OF EXISTING GRID COMPLETE E ■ �■■■, ■■■■■■l ■■■■■■l �■�•yy■•yy��■■■■o�1� ■■■■■■l ■■■■■■l ■■■■■■l M■■gIl ■■■■■■■■■■■■■■l �IMERIN ■■■■. E{I■y�■■. ■f 7 ■� x, „ RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/06/19 IMMMMEM4 m Mmml m■■■� iiiiiiis"Imil ►mil■■■■■■�■■■■I��■r e MEMO NEE MMMMMMM M■■ ■■■■■■■ E�II■ ■■■■■■■ NE: ! I ■`■`■■■ ,■■■m■`9 1■ ■■■s ■■■■R ■■■ ■ ■■■ ■o■o■ ■■wII■■■■■■■■■■■■L ■■■ ■■■ ■■n■■, ■►" ' 11■mi.\1_Il■■■■IEQI■■■g ■■■L ■ \■■■■■■■■■■■■rkc ■■■■■ ■■■l1 ■Sa ■■ \■IffiI■■■■■■■■■i MEON OEMOVE■ ■■w��MEN �■■■■■IffiI■■■m ■■■■■ . ■■■■IIIt■■■■■, ■■■■■ ■ I I�i � � �. ■■■■■imp■■� nonpmrmilmlpm No" ■■■MOON —� II ■ ■NEON 01511111111111 1 01 FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN SCALE:10 1'-0" x DENOTES EXISTING ACOUSTICAL CEILING GRID TO REMAIN. TILE TO BE REMOVED, UNLESS NOTED OTHERWISE DENOTES EXISTING ACOUSTICAL CEILING GRID TO BE REMOVED, UNLESS NOTED OTHERWISE e y 2'X2' LIGHTING FIXTURE TO BE REMOVED 0 2k4' LIGHTING FIXTURE TO BE REMOVED EXISTING CAN LIGHT TO BE REMOVED GENERAL REFLECTED CEILING NOTES A. REMOVE EXISTING SWITCHES THAT ARE NOT RE -USED. REMOVE CONDUIT AND WIRING BACK TO NEAREST BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH. B. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT ER'SATTTION PRIOR TO PERFORMING ANY W ORK. 1 C. EXISTING CEILING HEIGHT THROUGHOUT THE SPA IS+/-V-4"AFF, EBB NOTED OTHERWISE. V.I.F. D. EXISTING CEILING GRID TO REMAIN AND TILE TO BE SS NOTED OTHERWISE. E. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6'-9' FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. F. LIMITED CEILING SURVEY COMPLETED. CONTRACTOR TO VERIFY LOCATION OF GRIDS AND FIXTURES PRIOR TO START OF WORK. G. REMOVE ALL EXISTING LIGHT FIXTURES H. REPLACE ALL CEILING T-BARS THAT ARE DAMAGED. CAULK ALL MAINS THAT HAVE HOLES OR ARE DAMAGED. 07 DEMOLITION CEILING EXISTING BREMOVED. 02 FIXTURES TO BE REMOVED, VIF 03 EXISTING BULKHEAD TO BE REMOVED. 04 ING C G GRI REMA ISTIN USTI LING OBE EMOVED. OS CONTRACTOR TO PROVIDE ALLOWANCE FOR GRID REWORK IN THIS AREA 2N 111112 Li LI_L1J1 -- -- — — I I II I I 2 II II I 2 II II __ I II II 1 IT 1\III 0 IV Iiiiiiiiin mitsch I]ESIGN 200 s rangeline road suite 226 cam -el, indiana 46032 ph 317.573.2222 fx 317.573.2230 www.m itschdesign. com ^J LL LJ Q o Ijo C0 U) LU LU Q O w M O J Of M F �- LLJ LL z a U) Z az Z O ao O u) Zw > < �U LJ WMCF i ) o mom m 1W 9z" awmm v oOf W3X�'a82i Zw» Z�0 wScony L n ZZw 0 UMWH wUo­ ma"zZMR W yyyyy Qp€tfi�OWE ii sh�yy gh�[h�hy OO a 0 K3 3ie Z DRAWN BY CR/ME CHECKED BY ES MD PROJECT#: 18043 REFLECTED CEILING DEMOLITION PLAN D201 m ® FIXTURE AND EQUIPEMENT KEYNOTES CONSTRUCTION LEGEND 1 REF TO BE K RE E 4.1 . BO -FRE REFRIGERATOR, STAINLESS EXISTING WALL OR ITEM TO REMAIN LFI 790 GENERAL CONSTRUCTION NOTES PROPOSED WALL OR ITEM #F O WAS E BE E LT N DI HER, #GD SSLSS Q WAVE BEFIR AIRE, NTER MICRO VE, ST LESS STEEL FINISH, 1 #FFCM0934L/S. A. REFER TO SHEET G-002INDICATED FOR DOOR TYPES AND WALL DETAILS ® UND H, ADA TER REFRIGERATOR TO BE SUMMIT APPLIANCE, AL54 SERIES, STAINLESS STEEL B. DOORS NOT INDICATED BV A DOOR NUMBER DESIGNATION ARE EXISTING. FINISH, ADA COMPLIANT. C. CONTRACTOR TO PROVIDE BLINDSSTANDARD TO ELECTROSTATICALLY WINDOW BLINANED OFF EXISTING WHERE APPLICABLE (EXISTING BLINDS TO BE ELECTROSTATICALLY CLEANED OFF SITE). O UNDERCOUNTER ICE MAKER TO B CE-O-MA C 85 PO NO PEA ICE MA HINE GE f U090. D. PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES. PATCH AND REPAIR AS REQUIRED. E. PRROVVIDEDEBLOCKING IN WALLS BEFORE E ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT. F. SPACE OR E FINAL CLEANED RI OR O CORE D OVER . TENANT. 1 G. ALL FLOORS TO BE SCANNED PRIOR TO CORE DRILLING. H. INSULATE ANY PLUMBING PIPE IN CEILING NOT ALREADY INSULATED. I. ALL WALLS TO EXTEND UNDERSIDE OF DROP CEILING UNLESS OTHERWISE NOTED. WALLS TO DECK TO INCLUDE TRANSFER BOOT TO ALLOW FOR PROPER RETURN AIR -FLOW. J. ALL WALLS HAVE SOUND BAIT INSULATION IN WALL CAVITY, INCLUDING EXISTING. K. WHERE WALLS ALIGN WITH NEW WALLS, MATCH EXISTING STUD SIZE. °g 09 09 °g 09 09 09 CONSTRUCTION KEYNOTES 01 ALIGN 16'-3' 17'-2' 1T-0' 16'-9' 17'-3' 11'-41/2" 17'-11/4' 9'-111/2" 02 3'-0" WIDE X8'-0" HIGH DRYWALL WRAPPED OPENING. 5 S4.10 $4.10 5 05 05 05 05 05 03 PROVIDE CARD READER s4.10 n 54.10 S4.10 xzwux xxxux xxxux MEDIUM MEDIUM mmium MEDIUM MEDIUM $4,1D OFFICE $4'10 OFFICE $4'1° OFFICE yd OFFICE OFFICE OFFICE OFFICE OFF aD w zn ^.(' 04 SERVER ROOM TO RECE ;i P OOD A D CO WIT RE NT P INTTO MATCH 1 DI o 0 0 ❑ ADJACENT WALL COLD GROUND BARON BOARD GROUNDED TO ABOVE CEILING. iG iB5 �� te] O Jl 135� CONFERENCE y+ 05 PROVIDE 2X6 WOOD BLO IN OM FF AF L ON, 2 STUDQ CAVITIEI 538 423 424 425 426 536 427 478 ROOM GALLON WATER HEATER 84d0 491 1 1g S4.10 16'-11/2" 02 5410 5410 >�>O+ [AM-]091 PROVIDE 07 PROVIDE I/4'COPPER WATER LINE UNDER SINK. 01 54.10 512 513 514 a• A601 8 OB PROVIDE KOHLER VERSE UNDER -MOUNT KITCHEN SINK(K-75791-3) B DELTA TRASK SPOT SHIELD MEDIUM�, COFFEE S4.1013 OFFICE 54.10 e. A801 A601 IN 1 "OJ O i6.•O' >O, STAINLESS 1 HANDLE PULL DOWN FAUCET. OF zez la xn 12� 4'-77• n 1 35 '00°O.h+ 2 •m. /� >O� 09 SEE WALL TO MULLION DETAIL ON SHEET G002. S4.10 3,5Po,0713 $4.40 54.10 54.10 54.10 S4.10 16 519 v+ 10'-91/4^ (� � wr ''; S4.10 10 MAIL SLOT LOCATION ABOVE COUNTER SLOTS VERTICAL OR HORIZONTAL TO MAXIMIZE SPACE. MIN 50 \•" °1 ® mmuM �j NCI MEDIUM MEDIUM L�mu J h LMGE b 05 OFFICE OFFICE OFFICE 1• OFFICE d•• 69 11 FOLLOW TENANT SE FIVE R ROOM G U IDELINES FOR M ECHAN ICAL AND At R CONDITION ING SYSTEMS • A 2'-101/2" EXISTING 1 R49 NR 99 y^ $4'10 R31 4� 54.10 6'-3" 11'-81W T-13W 5'-0" 10'-61/4" T-53t4 54d0 08 12 PAINT DOOR TO MATCH NEW STANDARD FINISH, AND PAINT EXISTING FRAMES TO MATCH NEW. S4.10 HUDDLE ELECTRICAL h b S• S• S4.10 ��\ 1'O0° Sq.iO OOM GLAZING MATCH IGHTOF OORS/ERA ES, EQUAL SIZED PANELS WITH GASKET BETWEEN O•l �5p0• x] 12 ? 135� ^a 5 �� S+ /w' 13 50p, 135� b` 73 UTILIAING CRL GLA$$ PARTITION JOINTS. ME UM 537 L 01 3 'l- �\ 14 OFFICE �' 44 A601 A801 5 h ❑ ON ST WI AT FF,T-O'HIGH 4 3 1 S4.10 S4.10 54'70 15 g ^ PROVIDE 2X6 WOOD BLOCKING IN WALL FROM 4'-0' AFF TO 6'-0- AFF FOR WHITE BOARD LOCATION, 2 1J 183 420 T-0' 10 A801R Afi012 A702 .10 m 54.10 pg 15 q $4,1D B -- - _ N MEDIUM STUD CAVITIES. w � BUILT-IN 11 DEFILE ® ® BENCH SEATING 2, y 16 A• S• EXISTING WITH CUSHION TOP •2• z+L IS PROVIDE COAT ROD AND SHELF, PROVIDE HOOK AT ADA HEIGHT S4.10 J •y, ANITO (BRISA FABRIC) !n 10'-612' p, mvr $ 05 17 BENCH BASE AT 18" AFF WITH CUSHION TOP; FABRIC TO BE B O $H OF BASE $4.10 54.10 S� _-----_- • S4d0 � TO BE PL-3 ❑R' RoOii RESTawM - - 517 05 430 MmluM _ �..,.. Og >6, MEDIUM ]� 12 w hI� 19 y �73 OFFICE 1 PRO PAS OUG OOW "AF THT-6" EIGH BE 2'-". ,> OFFICE aE 54.40 _ L_I _ Sq,ip 5(b• >S• 431 ztD '`\b >> tsr J 54.10 1 ❑ 1 0 b 09 TEN NTPROVI EDWATE FILTER, PROVIDE ATERLINE 8Pow HISL CATION. S' � 54.10 uRDE 8�0• S4.10 < F 07 2 F �Siy+ � - OFFILE T-21/2' S4.10 ® 12 RECEnxa 08 5 ry 1 P 54.10 za a W 5 46601 �'S\ aricc CD 12 54.1 CD © �� ceFJamcax 6" ❑® S v o > 09 l� tss "O+ EXISTING 1 $4.40 Ir 1. a 3� ae S4.10 MEdu '01 O• 447 510 S S4.10 ELECOM ® 0 Afi01 J OFFICE 8 WO AGE ROOM DrEME ]d5; z49 09 sa.10 \ti 'az ,nDDn z� n g °o• ^\> O 5 ;b T' 2g A102 - S4,10 N 54.10 '1 g a p7 ____ N{ A S4.10 05 54.10 0 ® ® 4 07 D 459 % 05 MEDIUM •�S ^� p• N DS l IN 70 OFFICE ;� 84.10 - 11'=/•-- 2'-101/T `--- -- 432 >T, ti 49 2-5' 9'-43/4' 507 09 J eu "' S4d1 518 8 -6- w 54.40 '> �. '� s4.10 04 a 'r$ FI lt E > ,0' '\ $ 77 $4.11 r 3'-13/4' 4 54.10 523 )O'O+ 433 OFOFNee?• 09 $4.10 ^\rt• $ERVF'� a A601 0 fv" $ s"a 54.10 >• �$ 54.10 54.10 sod 1 54.10 5 >� 05 a MUDDLE n xmMM ROOM 5 OFFICE 446 NEgYN �• S4.13 $1.16 16. 9 OFFICE I T-4" 13 `13 at 1 >J. W i ,O CONFERENCE S4.1D S410 0t� y\� J MECUM JA .a Q 445 O z•t �P 'tn $4.16 ROOM b` u• R+ q ,?. OFFICE 09Q )p;' m ll 05 Ky 1 .� 4A0 IV S4.10 1S 54.10 -�' 601 1 s4d0 S4d0 8 b` LORGE 's. HUDDLE A601 Bi 5 �� s4.10 OFFICE $ 05 13 A601 08 Q3 wwuMu S4.10 OS mmux I OFFICE Real R°o S4.10 T-21/2" ICE Afi02 5 5 A602 I S OFFla �` 434 >S; 09 JA ® 5 10'-10" 8'-6" T-91/2" 14'311/2" 5'-0" 14'-73/4 ao $ w 435 xmxx Jl'`I'g, •44 S4.iD .10 $4.10 OFFICE S4.10 09 505 54.10 7'-73/4"-51/2"-33/4' N 0 05 483 r3's'00• S4.10 502 ->• s4.10 54.10 03 s4.10 S4AID 54.10 54.10 EXISTING s4.10 14' -1 1/2" 54.10>; YD ELECTRICAL 1 $4.10 6 09 owlee O' 54.40 1 ROOM OFFICCEE N �2, to s4d0 FILES $4.10 Fri ________________ 8'-51/4^1 _33-P9'-01/4' s4S 09 443 xn 1 525 .10 OS 'w 421 iO S4.10 to 18 534 533 532 531 530 529 528 527 526 LARGE 69 OFFICE \•yEJ� LORGE J $] O FICE y >5 $4.10 $4.10 54.10 54.10 $4.10 54.10 54.10 IN 1 LMOE \ MEDIUM MEDIUM mmuM LARGE E OFFICE OFFICE OFFICE 05 $4'1° OFFICE OFFICE OFFICE O5 5 OFFICE OFFICE 05 05 05 05 S4.10 ae ae a] p,G 250 ® ® as 25e 9'-103/4' 11'-6" 11'-31/4- 11'-61/2" 16'-9" 11'-61/2" 11'-13/4' 11'-6" 16'-113W 10'-111/4" RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel DATE: 03/06/19 m n 9 r mitsch ICI -SIGN 200 s rangeline road suite 226 carmel, Indiana 46032 ph 317.573.2222 fx 317.573.2230 W✓✓ W. m itschdesign.com J W a. O ED C:)r^ VJ VJ w F LU �Ny L I_ (N Q p F- w M O wM � LL C/) Z T 1 az ] Q Z w ❑ 0 5O G r_J V\ J / SC G �U LU sTATea i )� s� Raw - M S=wj 0 wk2C 0 a mphp,, �F-N� KK z30amO v �9SL w ZU, mzzw va y F)i� WUpF- o�o& D-Ol 00 WOW ¢ w a m ':CW Dow e O# o 0 aix OWE XZ z n DRAWN BY: CRIME CHECKED BY: ES MD PROJECT#: 18043 CONSTRUCTION PLAN A101 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/06/19 2 ENLARGED RECEPTION DESK SCALE: 318" = T-Cm N 1 ENLARGED PLAN - RESTROOMS SCALE: 318" =1'-T CONSTRUCTION LEGEND EXISTING WALL OR ITEM TO REMAIN PROPOSED WALL OR ITEM GENERAL CONSTRUCTION NOTES A. REFER TO SHEET G-002 FOR DOOR TYPES AND WALL DETAILS B. DOORS NOT INDICATED BY DOOR NUMBER DESIGNATION ARE EXISTING. C. CONTRACTOR TO PROVIDE STANDARD BUILDING WINDOW BLINDS. RE -USE EXISTING WHERE APPLICABLE (EXISTING BLINDS TO BE ELECTROSTATICALLY CLEANED OFF SITE). D. PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES. PATCH AND REPAIR AS REQUIRED. E. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT. F. SPACE TO BE FINAL CLEANED BEFORE TURNING OVER TO TENANT. G. ALL FLOORS TO BE SCANNED PRIOR TO CORE DRILLING. H. INSULATE ANY PLUMBING PIPE IN CEILING NOT ALREADY INSULATED. I. ALL WALLS TO EXTEND TO UNDERSIDE OF DROP CEILING UNLESS OTHERWISE NOTED. WALLS TO DECK TO INCLUDE TRANSFER BOOT TO ALLOW FOR PROPER RETURN AIR -FLOW. J. ALL WALLS TO HAVE SOUND BATT INSULATION IN WALL CAVITY, INCLUDING EXISTING. K. WHERE WALLS ALIGN WITH NEW WALLS, MATCH EXISTING STUD SIZE. CONSTRUCTION KEYNOTES 01 ALIGN 02 3'-0"WIDE X 8'-0' HIGH DRYWALL WRAPPED OPENING. 03 PROVIDE CARD READER 0q SERVER ROOM TO RECEIVE 4'X8' PLYWOOD BOARD COATED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL COLOR. GROUND BAR ON BOARD GROUNDED TO ABOVE CEILING. 05 PROVIDE 2X6 WOOD BLOCKING IN WALL FROM 4'-0" AFF TO 6'-0" AFF FOR TV LOCATION, 2 STUD CAVITIES. Ofi PROVIDE 6 GALLON WATER HEATER UNDER SINK. 07 PROVIDE 114" COPPER WATER LINE OB PROVIDE KOHLER VERSE UNDER -MOUNT KITCHEN SINK(K-75791-3) B DELTA TRASK SPOT SHIELD STAINLESS 1 HANDLE PULL DOWN FAUCET. 09 SEE WALL TO MULLION DETAIL ON SHEET G002. 10 MAIL SLOT LOCATION ABOVE COUNTER SLOTS VERTICAL OR HORIZONTAL TO MAXIMIZE SPACE. MIN 50 17 FOLLOW TENANT SERVER ROOM GUIDELINES FOR MECHANICAL AND AIR CONDITIONING SYSTEMS 72 PAINT DOOR TO MATCH NEW STANDARD FINISH, AND PAINT EXISTING FRAMES TO MATCH NEW. 73 GLAZING TO MATCH HEIGHT OF DOORS/FRAMES, EQUAL SIZED PANELS WITH GASKET BETWEEN UTILIAING CRL GLASS PARTITION JOINTS. 14 CONTINUOUS TRANSOM WINDOWS AT 6'-0"AFF, 2'-0"HIGH 15 PROVIDE 2X6 WOOD BLOCKING IN WALL FROM 4'-0'AFF TO 6'-0"AFF FOR WHITEBOARD LOCATION, 2 STUD CAVITIES. 18 PROVIDE COAT ROD AND SHELF, PROVIDE HOOK ATADA HEIGHT 77 BENCH BASE AT 18" AFF WITH CUSHION TOP; FABRIC TO BE BRISA, COLOR ARCTIC AND FINISH OF BASE TO BE PL-3 18 PROVIDE PASS THROUGH WINDOW AT 34"AFF. WIDTH TO BE 2'-6"AND HEIGHT TO BE 2'-6". TENANT PROVIDEDFILTER, PROVIDE BPOWER AT THIS LOCATION. PLUMBING KEYNOTES BING OTES TOIL IS EXIS G TO R IN, O2 URINAL IS EXISTING TO REMAIN. 1 O3 GRAB BARS SPEC TO BE LANDLORD BUILDING STANDARD ® TOILET PAPER DISPENSER SPEC TO BE LANDLORD BUILDING STANDARD O5 SANITARY NAPKIN DISPOSAL SPEC TO BE LANDLORD BUILDING STANDARD © FAUCET SPEC TO BE LANDLORD BUILDING STANDARD O7 SINK SPEC TO BE LANDLORD BUILDING STANDARD O PAPER TOWEL DISPENSER SPEC TO BE LANDLORD BUILDING STANDARD, PROVIDE POWER IF REQUIRED O9 MIRROR SPEC TO BE LANDLORD BUILDING STANDARD 10 TOILET PARTITIONS TO BE BUILDING STANDARD, FINISH TO BE: WILSONART VERANDA TEAK, 8209K-28 r mitsch IDESIGN 200 s rangeline road suite 226 ca"el, indiana 46032 ph 317.573.2222 fx 317.573.2230 www.m itschdesign. com Z ^J I..L LU U Q^ v / U) LU 2iO QO J LL z = Q GC L"L C W of M rC) rn v ¢z ❑ Q WZ_ Z W c0 Q �U No. M1tRW9RU sTATea SRO gp W of CI =j2 N wk > N� N ° OUTmtv t a� wM Lea MOMS o: oZ8"gow o m lap OEM ETZ Z DRAWN BY: CR/ME CHECKED BY: ES MD PROJECT#: 18043 VJ LU L.L ENLARGED CONSTRUCTION PLANS A102 REFLECTED CEILING PLAN LEGEND ALTERNATE PRICE: ALTERNATE PRICE: ALTERNATE PRICE: RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 03/06/19 PAINT EXISTING GRID PROVIDE NEW CEILING GRID CONTRACTOR TO PROVIDE ALLOWANCE FOR MECHANICAL AND CEILING REQORK TO ACCOMMODATE HIGHER CEILING IN RECEPTION ■nMMEN ■� INE ki■■■■�■■■■ N■■■■� ■p■■ II■IIII■■■N0 ■■■■girl■ ■■�l ®■11 e■■i�■■N■ 1111111011109031 ■■ ■■P� P AA 1=01■I,I ■Mill OAMEMEN uammmFMA■. 01 FIRST FLOOR REFLECTED CEILING PLAN SCALE: 116' =1'-0" DENOTES NEW 2k2' ACOUSTICAL CEILING TILE WITH EXISTING GRID; PATCH GRID WHERE REQUIRED ❑® DENOTES NEW BUILDING STANDARD 2'x2' RECESSED ELECTRICAL FIXTURE DENOTES NEW BUILDING STANDARD 2'x4' RECESSED ELECTRICAL FIXTURE DENOTES RECESSED LINEAR $D DENOTES LIGHT SWITCH WITH DIMMER WITH OCCUPANCY SENSOR DEN�3 WAY HT 3CUPANCY SENSWITCH WITH OCCUPANCY SENSOR WITH OCS Y OR $4 DENOTES AV LIGHT SWITCH WITH OCCUPANCY SENSOR LED EDGE LIGHT SENSOR DENOTES PENDANT LIGHT, P# COORDINATE MOUNTING HEIGHT WI TENANT DENOTES RETURN AIR GRILLE DENOTES DIFFUSER PURPOSES ONLY. FOR LIGHTING PRICING i MARVEL LIGHTING (317-697-8035). 8'-4" vooe�o�o THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFYALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK. CEILING HEIGHT THROUGHOUT THE SPACE IS 8'-6" A.F.F., UNLESS NOTED OTHERWISE. EXISTING CEILING GRID TO REMAIN, UNLESS NOTED OTHERWISE. CONTRACTOR TO REMOVE AND REPLACE ANY CEILING GRID THAT IS DAMAGED. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN TILE, UNLESS NOTED OTHERWISE. COLOR OF LIGHT SWITCH DEVICES AND COVERPLATE TO BE BUILDING STANDARD, UNLESS NOTED OTHERWISE. ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE DEVICE COVERPLATE. ELECTRICAL CONTRACTOR TO PROVIDE INFORMATION, LOCATION AND SPECIFICATIONS ON EXIT SIGNAGE, LIFE SAFETY SYSTEMS, 24 EMERGENCY LIGHTING, VENTILATIONS, HVAC SYSTEMS, CIRCUITING OF LIGHTS AND THERMOSTAT LOCATION ETC. THERMOSTATS SHALL BE LOCATED DIRECTLY ABOVE OR ADJACENT TO LIGHT SWITCH. ALLTHERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE PLACEMENT. SUPPLY AND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE WHITE IN COLOR. ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE. IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE DESIGNER PRIOR TO INSTALLATION. VERIFVALL SPRINKLER HEAD LOCATIONS. NOTIFY DESIGNER IF ANY DISCREPANCIES OCCUR. PROJECT CRITERIA TO MEET INDIANA ASHRAE 90.1 ENERGY CODES. PROVIDE 3WAY SWITCHES AT ENTRVIEXIT DOORS TO COMMON AREAS. PROVIDE EMERGENCY BATTERY PACKS AS NEEDED TO MATCH EXISTING. ALL TO BE AT CONSISTENT HEIGHT. LIGHT FIXTURES PROVIDED BY OWNER. NOTE QUANTITY ELECTRICIAN ASSUMING TO INSTALL. NIGHT LIGHTS TO BE ON EXISTING GENERATOR VERIFY SWITCHING DIAGRAM WITH TENANT PRIOR TO INSTALLATION. MECHANICAL GENERAL NOTES PROVIDE ADEQUATE HEATING/COOLING IN SPACE PER OCCUPANTS IN EACH AREA TO BE ABLE TO MAINTAIN 72 DEGREES YEAR ROUND. HVAC SYSTEM TO BE SEPARATED FROM ADJACENT SUITES SO THAT IT HAS ITS OWN DEVICES & CONTROLS. DESIGN LAYOUT OF RETURN DIFFUSERS SO THEY ARE NOT ADJACENT TO EACH OTHER OR TO ADJACENT WALL TO PREVENT SOUND TRANSFER. SUPPLY DIFFUSERS: 1 PER 200 SF MINIMUM. ADJUST PLAN ACCORDINGLY AND AS NEEDED. INSTALL ONE (1) 2'X2' RAG PER 1,000 SF. INSTALL ONE (1) 6°X2' RAG IN EACH OFFICE. ADJUST PLAN ACCORDINGLY AND AS NEEDED. SUBMIT DESIGN BUILD LAYOUT TO OWNER FOR APPROVAL PRIOR TO COMPLETING. PROVIDE A COPS' OF HVAC-BALANCE REPORT TQOW NER. TO REMAIN. SUPPLYAND REUTRN LOCATION TO A A A ®REFLECTED CEILING PLAN KEYNOTES 01 ALIGN 02 BOTTOM OF DRYWALL HEADER TO BE 8'-6" AFF. PROVIDE ANGLED KICKER STUD AS REQUIRED FOR STABILITY. HIDEyGQKERABOVE DROP CEILING. HEADER TO DECK. HEADER -ON ALL SJOES TO BERA TIE INTO EXISTING CIRCUITS AND SWITCHING IN THIS OS CONTRACTOR TO CONFIRM FEASIBILITY OF NEW CEILING HEIGHT AND FINISH -PROVIDE COST ALLOWANCE AS ALTERNATE FOR MECHANICAL REWORK O6 EXISTING DIFFUSER, RETURN AIR GRILLE, AND EXHUAST TO REMAIN 07 PROVIDE EXHAUST FAN IN SERVER ROOM AND A DEDICATED VAV TO SERVE CONNECTED TO BUILDING SUPPLY UNLESS OTHERWISE NOTED THAT 24f7 COOLING IS REQUIRED. IF 2417 COOLING IS REQUIRED COORDINATE EQUIPMENT WITH OWNER. METER FOR WATERIELECTRICITY REQUIRED. iii immiiioHamon ve■aeeeo■ooee■eeo Ift mitsch DESIGN 200 s rangeline road suite 226 ca"el, indiana 46032 ph 317.573.2222 fx 317.573.2230 www.m itschdesign. com CZI/ J U a ff ^^ fVa.f^ vJ J LU �p Q O J LL Z = Occ Q GC G O O U) UJ F In N w Of M LM r r� v W az Z �o LU �J _O VJ Z UJ LU �U sTArea DRAWN BY CRM1E CHECKED BY ES MD PROJECT#: 18043 N REFLECTED CEILING PLAN A201