HomeMy WebLinkAboutLEGACY RIDGE 136 - LR136 (AS DESIGNED)IECC 2009 Performance Compliance Property 14074 LARSON DR CARMEL, IN 46033 Organization TSI Energy Solutions Matthew Timmons LR136 (AS DESIGNED) Builder LEGACY RIDGE 136 LENNAR HOMES Inspection Status Results are projected Annual Energy Cost C-M, Energy Solutions Design IECC 2009 As Designed Performance Heating $1,905 $1,906 Cooling $290 $269 Water Heating $411 $411 SubTotal - Used to determine compliance $2,607 $2,586 Lights & Appliances $959 $959 Onsite generation $0 $0 Total $3,565 $3,545 402.5 405.3 402.4.2.1 Performance-based compliance Air Leakage Testing Area -weighted average fenestration passes by 0.8% SHGC 402.5 403.2.2 Mandatory Checklist Area -weighted average fenestration Duct Testing U -Factor Design exceeds requirements for IECC 2009 Performance compliance by 0.8%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 11/16/18 at 8:26 AM Ekotrope RATER - Version 3.1.0.2049 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 14074 CARSON DR CARMEL, IN 46033 LENNAR HOMES Ceiling Attic, R-38 FAGT=eWre[7',►F1IM:5[y Foundation Walls R-11 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U -Value: 0.32, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 328.0 CFM @ 25 Pa Total Duct Leakage 437.0 CFM @ 25 Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 11/16/18 at 8:26 AM Ekotrope RATER - Version 3.1.0.2049 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 14674 LARSON DR CARMEL, IN 46633 LR136 (AS DESIGNED) LEGACY RIDGE 136 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 5,469 48,294 16,186 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (1,951 s.f.) R-6 perimeter insulation, R-6 under slab insulation. Framed Floor El Name: AMBIENT (15 s.f.) R-6 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 178, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.66 Feet from top of wall to top of insulation: 6, Feet from top of wall to bottom of insulation: 4 [ Name: CONDIGAR (Exterior Perimeter [ft]: 31, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.66 Feet from top of wall to top of insulation: 6, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (3,264 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (468 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 14674 LARSON DR TSI Energy Solutions CARMEL, IN 46633 Matthew Timmons LR136 (AS DESIGNED) Builder LEGACY RIDGE 136 LENNAR HOMES Name: CONDIGAR (279 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (255 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (314 s.f.) R: 13.575 El Name: CONDIGAR (31 s.f.) R: 10.876 Name: CONDIATTIC (31 s.f.) R: 13.575 Roof El Name: MAIN (1,966 s.f.) R-27.55 continuous insulation, R-16.15 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (20 s.f.) U: 6.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (138 s.f.), U: 0.320, SHGC: 0.28, Orientation: EAST El Name: BACK (210 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST C", Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization 14074 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status Results are projected LR136 (AS DESIGNED) Builder LEGACY RIDGE 136 LEN NAR HOMES E] Name: BACK BSMT (11 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST E] Name: SLIDER (40 s.f.), U:0.280, SHGC: 0.32, Orientation: WEST E] Name: RIGHT SIDE (82 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH El Name: LEFT SIDE (121 s.f.), U:0.320, SHGC: 0.31, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 92.1 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 4829 CFM50 (6 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 14074 LARSON DR CARMEL, IN 46033 LR136 (AS DESIGNED) LEGACY RIDGE 136 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 328.0 CFM @ 25 Pascals Total Duct Leakage is specified in Ekotrope at 437.0 CFM @ 25 Pascals Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization C-MEnergy Solutions 14074 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status LR136 (AS DESIGNED) Builder Results are projected LEGACY RIDGE 136 LENNAR HOMES enerahuilding Information mber Of Bedrooms 4 mber Of Floors 2 nditioned Floor Area [sq. ft.] 5,469 conditioned, attached garage? Yes nditioned Volume [cu. ft.] I 48,294 tal Units in Building 1 sidence Type Single family detached del SOUTHILL C mmunity LEGACY RIDGE 136 mate Zone 5A Basement Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, Oft 1 7 178 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, Oft 1 7 31 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R -value Top Bottom R-11 Draped, Oft 0 4 No 11.00 Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 1 Below Grade ❑ 0 1.951.0 sq. R. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Type Slab Campletell Undersla6lnsulatian Perimeter Insulation Perimeter Insulation R R�alue Insulated. Width [ft] Depth 1111 Value Uninsulated Wood Frame / Other No ❑ 0 D 0.00 1 Building Summary Property Organization 14074 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LR136 (AS DESIGNED) Builder LEGACY RIDGE 136 LENNAR HOMES ramed Floor Attic Name Library Type Ca AMBIENT R-38, GR1 Unconditioned, attached garage Rim Joist Library List Medium Framed Floor Library List Attic Name Rvalue R-38, GR1 33.825 CTS,Eneergy Solutions Inspection Status Results are projected Floor Grade Surface Area Location 1.23 Above Grade 15.0 sq. ft Exposed Exterior Rim Joist Name Library Type Surface Area Location CONDIAMB G1 R-13, R-3.0 314.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-13, R-3.0 31.0 sq. ft. Attic CONDIGAR G1 R-13, OSB 31.0 sq. ft. Unconditioned, attached garage Rim Joist Library List Medium 255.0 sq. fl. Attic Name R value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 li Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-13 BATT, R-3.0 Medium 3.204.0 sq. fl. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 468.0 sq. fl. Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3.0 Medium 255.0 sq. fl. Attic 2 Building Summary C-M Energy Solutions Property Organization 14074 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status LR136 (AS DESIGNED) Builder Results are projected LEGACY RIDGE 136 LENNAR HOMES Name Library Type Surface Calor Surface Area Location CONDIGAR G1 R-13 Gar Walls Medium 279.0 sq. fl. Unconditioned, attached garage Wall Library List Name R -value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R-3.0 2X6 20217 Glazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft Te Overhang Ft Te Orientation Surface Area Assignment Top Bottom BACK 111-.32, SHGG.31 CONDIAMB ❑ ❑ ❑ West 210.0 sq. ft. BACK BSMT 111-.32, SHGG.31 CONDIAMB 0 0 ❑ West 11.0 sq. ft. FRONT 111-.32, SHGG28 CONDIAMB 0 0 ❑ East 138.0 sq. ft. LEFT SIDE 111-.32, 8HGG.31 CONDIAMB 0 0 0 South 121.0 sq. ft. RIGHT SIDE 111-.32, SHGG.31 CONDIAMB 0 0 0 North 82.0 sq. & SLIDER U-28, 3HGG.32 CONDIAMB 0 0 0 West 40.0 sq. & Glazing Library List Name Shg c U factor U-28, SHGC-.32 0.32 0280 U-.32, SHGC-28 028 0.320 U-.32, SHGC-.31 0.31 0320 Building Summary Property 14074 LARSON DR CARMEL, IN 46033 LR136 (AS DESIGNED) LEGACY RIDGE 136 kylight Skylight Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Opaque Door Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta n ce FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 sq. ft Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 sq. ft Exposed Exterior Opaque Door Library List Name Steel Door U -factor 0.182 Roof Insulation Name Library Type Roof -Deck Area [sq. ft.] Cray or Concrete Roof Surface Color Surface Area Location Tiles MAIN R-38 Blown, GR1 Roof Insulation Library List Name Has 93S No R-38 Blown, GR1 No 38268 Medium 1.966.0 sq. ft Attic 4 Building Summary Property 14074 LARSON DR CARMEL, IN 46033 LR136 (AS DESIGNED) LEGACY RIDGE 136 hole House Infiltration Infiltration I6 ACH at 50 Pa 1 Mechanical Ventilation Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES Blower -door tested 4 None Present C-M, Energy Solutions Lighting % Interior Fluorescent % Interior LED Lighting I Exterior Fluorescent % Exterior LED Lighting I Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting C 100 Onsite Generation W IL None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present 0 100 0 100 Building Summary Property Organization 14074 LARSON DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LR136 (AS DESIGNED) Builder LEGACY RIDGE 136 LENNAR HOMES Inspection Status Results are projected conditioning Equipment Name Library Type Heating Percent Load Air conditioner (2) CA13NA042 0% I Fuel -fired air 912SA4808OS17 100% distribution (1) IWater Heating (3) RE350" 0% 1 Equipment Type: 912SA4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type Single Speed (PSC) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 977 Equipment Type: CA13NA04 Fuel Type Electric Distribution Type Forced Air Motor Type Single Speed (PSC) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 7 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 C-M, Energy Solutions g Percent LOW Hot water icc% 0% 0% 100% Building Summary Property 14074 LARSON DR CARMEL, IN 46033 LR136 (AS DESIGNED) LEGACY RIDGE 136 ibution System Distribution Type Heating Equipment Cooling Equipment Sq. Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply Duct Area [sq. ft.] Return Duct Area [sq. ft.] Duct Leakage to Outdoors {CFM25} Total Leakage [CFM&nbsp;@&nbsp;25Pa] Total Leakage Duct Test Conditions Use Default Flow Rate Duct 1 Duct Location Percent Supply Area Percent Return Area Duct 2 Duct Location Percent Supply Area Percent Return Area Duct 3 Duct Location Percent Supply Area Percent Return Area Duct 4 Duct Location Percent Supply Area Percent Return Area Duct 5 Duct Location Percent Supply Area Percent Return Area Duct 6 Duct Location Percent Supply Area Percent Return Area Ceiling Fan Has Ceiling Fan Cfm Per Watt Water Distribution Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Forced Air Fuel -fired air distribution {1 } Air conditioner (2) 5469 6 30 30 1107.5 1025.4 328 437 Post -Construction Yes Conditioned Space 70 70 Attic (well vented, under insulation) 30 30 Conditioned Space 0 0 Conditioned Space 0 0 Conditioned Space 0 0 Conditioned Space 0 0 No 100 Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 125 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length ]ft] 20 Drain Water Heat Recovery? No Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 14074 LARSON DR CARMEL, IN 46033 LR136 (AS DESIGNED) LEGACY RIDGE 136 lathes Dryer Fuel Type Cef Field Utilization r thes Washer l Energy Rating tric Rate ual Gas Cost Rate acity Kitchen Appliances Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Notes Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Electric 2.32 Timer Controls 704 kWh/Year $0.08,'kWh $23.00 $0.58,'Therm 2.847 0.331 Standard 270 kWh Electric No No 709 kWh/Year Inspection Status Results are projected C-M, Energy Solutions 11