HomeMy WebLinkAboutLEGACY RIDGE 136 - LR136 (AS DESIGNED)IECC 2009 Performance Compliance
Property
14074 LARSON DR
CARMEL, IN 46033
Organization
TSI Energy Solutions
Matthew Timmons
LR136 (AS DESIGNED) Builder
LEGACY RIDGE 136 LENNAR HOMES
Inspection Status
Results are projected
Annual Energy Cost
C-M,
Energy Solutions
Design
IECC 2009
As Designed
Performance
Heating
$1,905
$1,906
Cooling
$290
$269
Water Heating
$411
$411
SubTotal - Used to determine compliance
$2,607
$2,586
Lights & Appliances
$959
$959
Onsite generation
$0
$0
Total
$3,565
$3,545
402.5
405.3 402.4.2.1
Performance-based compliance Air Leakage Testing
Area -weighted average fenestration
passes by 0.8%
SHGC
402.5 403.2.2
Mandatory Checklist
Area -weighted average fenestration Duct Testing
U -Factor
Design exceeds requirements for IECC 2009 Performance compliance by 0.8%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 11/16/18 at 8:26 AM
Ekotrope RATER - Version 3.1.0.2049
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
14074 CARSON DR
CARMEL, IN 46033
LENNAR HOMES
Ceiling Attic, R-38
FAGT=eWre[7',►F1IM:5[y
Foundation Walls R-11
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 6 ACH50
Window U -Value: 0.32, SHGC: 0.31
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 328.0 CFM @ 25 Pa
Total Duct Leakage 437.0 CFM @ 25 Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 11/16/18 at 8:26 AM
Ekotrope RATER - Version 3.1.0.2049
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
14674 LARSON DR
CARMEL, IN 46633
LR136 (AS DESIGNED)
LEGACY RIDGE 136
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
5,469
48,294
16,186
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT (1,951 s.f.)
R-6 perimeter insulation, R-6 under slab insulation.
Framed Floor
El Name: AMBIENT (15 s.f.)
R-6 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
[ Name: CONDIAMB (Exterior Perimeter [ft]: 178, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7)
R: 11.66
Feet from top of wall to top of insulation: 6, Feet from top of wall to bottom of insulation: 4
[ Name: CONDIGAR (Exterior Perimeter [ft]: 31, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7)
R: 11.66
Feet from top of wall to top of insulation: 6, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDIAMB (3,264 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2X6 (468 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property Organization
14674 LARSON DR TSI Energy Solutions
CARMEL, IN 46633 Matthew Timmons
LR136 (AS DESIGNED) Builder
LEGACY RIDGE 136 LENNAR HOMES
Name: CONDIGAR (279 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (255 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Name: CONDIAMB (314 s.f.)
R: 13.575
El Name: CONDIGAR (31 s.f.)
R: 10.876
Name: CONDIATTIC (31 s.f.)
R: 13.575
Roof
El Name: MAIN (1,966 s.f.)
R-27.55 continuous insulation, R-16.15 cavity insulation
Insulation Grade: I
Opaque Door
El Name: FRONT (20 s.f.)
U: 6.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
El Name: FRONT (138 s.f.), U: 0.320, SHGC: 0.28, Orientation: EAST
El Name: BACK (210 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST
C",
Energy Solutions
2
Energy Code Inspection Checklist
C-M
Energy Solutions
Property Organization
14074 LARSON DR TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons Inspection Status
Results are projected
LR136 (AS DESIGNED) Builder
LEGACY RIDGE 136 LEN NAR HOMES
E] Name: BACK BSMT (11 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST
E] Name: SLIDER (40 s.f.), U:0.280, SHGC: 0.32, Orientation: WEST
E] Name: RIGHT SIDE (82 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH
El Name: LEFT SIDE (121 s.f.), U:0.320, SHGC: 0.31, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 92.1 AFUE
Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 4829 CFM50 (6 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
3
Energy Code Inspection Checklist
Property
14074 LARSON DR
CARMEL, IN 46033
LR136 (AS DESIGNED)
LEGACY RIDGE 136
Duct Leakage
Duct System 1
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 328.0 CFM @ 25 Pascals
Total Duct Leakage is specified in Ekotrope at 437.0 CFM @ 25 Pascals
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization
C-MEnergy
Solutions
14074 LARSON DR
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Inspection Status
LR136 (AS DESIGNED)
Builder Results are projected
LEGACY RIDGE 136
LENNAR HOMES
enerahuilding Information
mber Of Bedrooms
4
mber Of Floors
2
nditioned Floor Area [sq. ft.]
5,469
conditioned, attached garage?
Yes
nditioned Volume [cu. ft.]
I
48,294
tal Units in Building
1
sidence Type
Single family detached
del
SOUTHILL C
mmunity
LEGACY RIDGE 136
mate Zone
5A
Basement Wall
Name Library Type
Height Above Grade Depth Below Grade Perimeter Location
Enclosing
CONDIAMB R-11 Draped, Oft
1 7
178 Exposed Exterior
Conditioned Space
CONDIGAR R-11 Draped, Oft
1 7
31 Exposed Exterior
Conditioned Space
Basement Wall Library List
Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation
Is Fully Insulated
R -value
Top Bottom
R-11 Draped, Oft
0 4
No
11.00
Name Library Type
Perimeter Floor Grade Carpet R Exposed
Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated
1 Below Grade ❑ 0
1.951.0 sq. R. Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Type
Slab Campletell Undersla6lnsulatian Perimeter Insulation
Perimeter Insulation R
R�alue
Insulated. Width [ft] Depth 1111 Value
Uninsulated Wood Frame / Other
No ❑
0 D
0.00
1
Building Summary
Property
Organization
14074 LARSON DR
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
LR136 (AS DESIGNED)
Builder
LEGACY RIDGE 136
LENNAR HOMES
ramed Floor
Attic
Name Library Type
Ca
AMBIENT R-38, GR1
Unconditioned, attached garage
Rim Joist Library List
Medium
Framed Floor Library List
Attic
Name
Rvalue
R-38, GR1
33.825
CTS,Eneergy Solutions
Inspection Status
Results are projected
Floor Grade Surface Area Location
1.23 Above Grade 15.0 sq. ft Exposed Exterior
Rim Joist
Name
Library Type
Surface Area
Location
CONDIAMB
G1 R-13, R-3.0
314.0 sq. ft.
Exposed Exterior
CONDIATTIC
G1 R-13, R-3.0
31.0 sq. ft.
Attic
CONDIGAR
G1 R-13, OSB
31.0 sq. ft.
Unconditioned, attached garage
Rim Joist Library List
Medium
255.0 sq. fl.
Attic
Name
R value
G1 R-13, OSB
10.876
G1 R-13, R-3.0
13.575
li
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
G1 R-13 BATT, R-3.0
Medium
3.204.0 sq. fl.
Exposed Exterior
CONDIAMB 2X6
G1 R-19, R-3.0 2X6
Medium
468.0 sq. fl.
Exposed Exterior
CONDIATTIC
G1 R-13 BATT, R-3.0
Medium
255.0 sq. fl.
Attic
2
Building Summary
C-M
Energy Solutions
Property Organization
14074 LARSON DR TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
Inspection Status
LR136 (AS DESIGNED) Builder Results are projected
LEGACY RIDGE 136 LENNAR HOMES
Name Library Type Surface Calor Surface Area Location
CONDIGAR G1 R-13 Gar Walls Medium 279.0 sq. fl. Unconditioned, attached garage
Wall Library List
Name R -value
G1 R-13 BATT, R-3.0 15.12
G1 R-13 Gar Walls 11.141
G1 R-19, R-3.0 2X6 20217
Glazing
Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft Te Overhang Ft Te Orientation Surface Area
Assignment Top Bottom
BACK 111-.32, SHGG.31 CONDIAMB ❑ ❑ ❑ West 210.0 sq. ft.
BACK BSMT 111-.32, SHGG.31 CONDIAMB 0 0 ❑ West 11.0 sq. ft.
FRONT 111-.32, SHGG28 CONDIAMB 0 0 ❑ East 138.0 sq. ft.
LEFT SIDE 111-.32, 8HGG.31 CONDIAMB 0 0 0 South 121.0 sq. ft.
RIGHT SIDE 111-.32, SHGG.31 CONDIAMB 0 0 0 North 82.0 sq. &
SLIDER U-28, 3HGG.32 CONDIAMB 0 0 0 West 40.0 sq. &
Glazing Library List
Name Shg c U factor
U-28, SHGC-.32 0.32 0280
U-.32, SHGC-28 028 0.320
U-.32, SHGC-.31 0.31 0320
Building Summary
Property
14074 LARSON DR
CARMEL, IN 46033
LR136 (AS DESIGNED)
LEGACY RIDGE 136
kylight
Skylight Library List
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Opaque Door
Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location
Assignment Ab sorpta n ce
FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 sq. ft Exposed Exterior
GARAGE
Steel Door CONDIGAR 0.9 0.75 Medium 18.0 sq. ft Exposed Exterior
Opaque Door Library List
Name
Steel Door
U -factor
0.182
Roof Insulation
Name Library Type Roof -Deck Area [sq. ft.] Cray or Concrete Roof Surface Color Surface Area Location
Tiles
MAIN R-38 Blown, GR1
Roof Insulation Library List
Name Has
93S No
R-38 Blown, GR1 No 38268
Medium 1.966.0 sq. ft Attic
4
Building Summary
Property
14074 LARSON DR
CARMEL, IN 46033
LR136 (AS DESIGNED)
LEGACY RIDGE 136
hole House Infiltration
Infiltration
I6 ACH at 50 Pa
1
Mechanical Ventilation
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
Blower -door tested 4
None Present
C-M,
Energy Solutions
Lighting
% Interior Fluorescent % Interior LED Lighting I Exterior Fluorescent % Exterior LED Lighting I Garage Fluorescent % Garage LED Lighting
Lighting Lighting Lighting
C
100
Onsite Generation W IL
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
0
100
0
100
Building Summary
Property
Organization
14074 LARSON DR
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
LR136 (AS DESIGNED)
Builder
LEGACY RIDGE 136
LENNAR HOMES
Inspection Status
Results are projected
conditioning Equipment
Name Library Type Heating Percent Load
Air conditioner (2) CA13NA042 0%
I Fuel -fired air 912SA4808OS17 100%
distribution (1)
IWater Heating (3) RE350" 0%
1
Equipment Type: 912SA4808OS17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
Single Speed (PSC)
Heating Efficiency
92.1 AFUE
Heating Capacity [kBtulh]
78
Use default EAE
No
EAE [kWh]
977
Equipment Type: CA13NA04
Fuel Type Electric
Distribution Type Forced Air
Motor Type Single Speed (PSC)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 40
7
Equipment Type: RE350*
Fuel Type Electric
Distribution Type Hydronic Delivery
Hot Water Efficiency 0.93 Energy Factor
Tank Capacity (gal.) 50
Hot Water Capacity [kBtulh] 15.4
Recovery Efficiency 0.98
C-M,
Energy Solutions
g Percent LOW Hot water
icc%
0%
0%
100%
Building Summary
Property
14074 LARSON DR
CARMEL, IN 46033
LR136 (AS DESIGNED)
LEGACY RIDGE 136
ibution System
Distribution Type
Heating Equipment
Cooling Equipment
Sq. Feet Served
# Return Grilles
Supply Duct R Value
Return Duct R Value
Supply Duct Area [sq. ft.]
Return Duct Area [sq. ft.]
Duct Leakage to Outdoors {CFM25}
Total Leakage [CFM @ 25Pa]
Total Leakage Duct Test Conditions
Use Default Flow Rate
Duct 1
Duct Location
Percent Supply Area
Percent Return Area
Duct 2
Duct Location
Percent Supply Area
Percent Return Area
Duct 3
Duct Location
Percent Supply Area
Percent Return Area
Duct 4
Duct Location
Percent Supply Area
Percent Return Area
Duct 5
Duct Location
Percent Supply Area
Percent Return Area
Duct 6
Duct Location
Percent Supply Area
Percent Return Area
Ceiling Fan
Has Ceiling Fan
Cfm Per Watt
Water Distribution
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Forced Air
Fuel -fired air distribution {1 }
Air conditioner (2)
5469
6
30
30
1107.5
1025.4
328
437
Post -Construction
Yes
Conditioned Space
70
70
Attic (well vented, under insulation)
30
30
Conditioned Space
0
0
Conditioned Space
0
0
Conditioned Space
0
0
Conditioned Space
0
0
No
100
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
125
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length ]ft] 20
Drain Water Heat Recovery? No
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
14074 LARSON DR
CARMEL, IN 46033
LR136 (AS DESIGNED)
LEGACY RIDGE 136
lathes Dryer
Fuel Type
Cef
Field Utilization
r
thes Washer
l Energy Rating
tric Rate
ual Gas Cost
Rate
acity
Kitchen Appliances
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Notes
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Electric
2.32
Timer Controls
704 kWh/Year
$0.08,'kWh
$23.00
$0.58,'Therm
2.847
0.331
Standard
270 kWh
Electric
No
No
709 kWh/Year
Inspection Status
Results are projected
C-M,
Energy Solutions
11