HomeMy WebLinkAboutS201LEDLED LED LED LED 29 D3.0 RADON PIPE13'-2"CLEAR SPAN 2x10 x 16'-0" JOISTS @ 19.2" o.c. 15'-512" FLOOR SHEATHING START POINT 13'-13 4"8'-1158"1712"1'-71516" FROM OUTSIDE OF FRAME TO ℄ OF FIRST JOIST 1'-91 4"312"13'-4"CLEAR SPAN2'-0"CANT.15'-312"CLEAR SPAN 312"3 12"512"FROM OUTSIDE OF FRAME TO ℄ OF FIRST JOIST 2x10 x 16'-0" JOISTS @ 19.2" o.c. 2x10 x 16'-0" JOISTS @ 19.2" o.c. 13'-1012" CLEAR SPAN 512" 3'-2"512"312"512"2x10 x 4'-0" GUSSET ATTACHED TO 2x10 FLOOR JOIST - SEE DTL. 25/D3.0 2x10 BLOCKING @ GIRDER TRUSS POINT LOAD - ALIGN w/ JOISTDOUBLE 2x10 x 14'-0" JOIST12'-87 8"1'-2"1'-23 8" 10" 15'-112"CLEAR SPAN 312"18'-9" CLEAR SPAN 312"312"1'-4" 19'-1" 2x6 BALLOON FRAME WALL 17'-11"13'-9" 8'-8" 9'-3"8'-8"11'-9" QUADRUPLE 2x10 x 16'-0" JOISTDO U BL E JOIS T12'-31 8"USE SIMPSON STRONG-TIE JOIST HANGER # HUC210-4 OR EQUIVALENT FROM OUTSIDE OF FRAME TO ℄ OF FIRST JOIST 1'-61 4" 8'-0" 33'-7" 9'-1112" 2x10 x 14'-0" JOISTS @ 19.2" o.c. 14'-5716" 21716" 19316" 16316" 19316" REVERSE LAP2'-134"4'-63 4" 9'-73 16" 117 8"1'-31 8" FROM OUTSIDE OF FRAME TO ℄ OF FIRST JOIST SUNROOM FLUSH BEAM NOTE: USE (2) 13 4" x 18" MICRO-LAM LVL's - w/ (3) 2x6 JACK STUDS @ FAMILY RM - w/ (5) 2x4 JACK STUDS @ KITCHEN 12'-4" (2) 13 4" x 18" MICRO-LAM LVL's FRAMER'S NOTE: - REFER TO TABLE S-1 ON SHEET GN FOR STANDARD JOIST DRILLING SPECIFICATIONS. - FOR DRAIN PIPES UP TO 4" DIA. REFER TO DETAIL 25/D3.0. 8'-11" 23'-712" 10'-23 4" 3" 23'-412" 5516" 107 8" 20'-95 8" 2x10 x 16'-0" JOISTS @ 19.2" o.c. DOUBLE 2x10 x 20'-0" JOISTDOUBLE 2x10 x 20'-0" JOIST3'-412"3'-2"2'-03 4"20'-312" 12'-11" 20'-9 12" 54'-0"2'-0" 31'-8"33'-8"54'-0"2'-0"31'-8"33'-8"11'-1014" 2x10 x 6'-0" JOISTHOLD JOIST TO INSIDE OF WALL BELOW FOR HVAC CLEARANCE 2x10x14'-0" JOIST14" 141 4"14 1 4" 14 3 4" 3"2x10x14'-0" JOIST2x10x14'-0" JOIST2x10x14'-0" JOIST2x10 x 6'-0" JOISTUSE (2) 2x10's AS FLUSH BEAM - SET FLUSH w/ 2nd FLR. JOISTS FLUSH BEAM NOTE:2x10x14'-0" JOIST2x10x14'-0" JOIST2x10x14'-0" JOIST14" 14" 16" WILLIAM L.KAUF H OL Z ARCHITECTTALLYNS RIDGEREASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc. JOB INFO:DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:1/14/2019 3:31 PM# TLR010100000 NAGENDRA TOMAR3291 TAMERLANE PLACECLAYTON 54-370-CLAYTON AMERICAN CLASSIC WITH BRICK CARMEL, IN10 05/2017MP------------------------------------------------ fieldspecchange@fischerhomes.comREVISED BY:-------- ----SAPPHIRE TRADE SUPPORT sapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC A5.1 SCALE = 1'-0" SECOND FLOOR JOIST LAYOUT 1/4"01 01/31/19 William Hohlt