HomeMy WebLinkAboutTLR-010 ENERGYIECC 2009 Performance Compliance
Property
3291 TAMERLANE PL
CARMEL, IN 46074
TLR010 (AS DESIGNED)
TALLYNS RIDGE 10
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,683
$241
$410
$2,334
$1,242
$0
$3,577
Requirements
C4405.3
Performance-based compliance passes by 1.3%
402.4.12
Air Leakage Testing
C4402.5
Area -weighted average fenestration SHGG
402.5
Area -weighted average fenestration U -Factor
40322
Duct Testing
Mandatory Checklist
R405.2
Duct Insulation
C-M,
Energy Solutions
As Designer`!
$1,671
$222
$410
$2,303
$1,242
$0
$3,546
Design exceeds requirements for IECC 2009 Performance compliance by 1.3%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
1115119 at 7:58 AM
Ekotrope RATER - Version 3.1.0.2084
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
3291 TAMERLANE PL
CARMEL, IN 46074
FISCHER HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-10
Framed Floor R-30
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 6 ACH50
Window U -Value: 0.31, SHGC: 0.28
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 239.0 CFM @ 25Pa
Total Duct Leakage 383.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name
Michael Hill
Organization: TSI Energy Solutions
Signature:
Date: 1115/19 at 7:58 AM
Ekotrope RATER - Version 3.1.0.2084
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
Organization
3291 TAMERLANE PL
TSI Energy Solutions
CARMEL, IN 46074
317-846-4655
Michael Hill
TLRO10 (AS DESIGNED)
TALLYNS RIDGE 10
Builder
FISCHER HOMES
General Building Information
Conditioned Area (sq ft) 4,798
Conditioned Volume (cubic ft) 44,822
Insulated Shell Area (sq ft) 9,747
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT (1,707 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: OVER GARAGE (3 21 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
El Name: OVER AMBIENT (28 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
Foundation Wall
[ Name: CONDIAMB (Exterior Perimeter [ft]: 168, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 10.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
E[ Name: GOND/GAR (Exterior Perimeter [ft]: 42, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 10.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDIAMB (2,433 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property
Organization
3291 TAMERLANE PL
TSI Energy Solutions
CARMEL, IN 46074
317-846-4655
Michael Hill
TLRO10 (AS DESIGNED)
TALLYNS RIDGE 10
Builder
FISCHER HOMES
El Name: CONDIAMB 2X6 (363 s.f.)
R-0.41 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (378 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIATTIC (214 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
Name: CGNDIAMB (251 s.f.)
R: 15.414
Name: CGNDIGAR (42 s.f.)
R: 15.414
Name: CONDIATTIC (58 s.f.)
R: 15.414
Roof
El Name: SECOND (1,960 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
El Name: SUNROOM (102 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Inspection Status
Results are projected
C",
Energy Solutions
2
Energy Code
Inspection Checklist
Property
C-MEnergy Solutions
Organization
3291 TAMERLANE PL
TSI Energy Solutions
CARMEL, IN 46074
317-846-4655 Inspection Status
Michael Hill Results are projected
TLR010 (AS DESIGNED)
TALLYNS RIDGE 10
Builder
FISCHER HOMES
Glazing
E] Name: FRONT X130 s.f.), U: 0.310, SHGC: 0.28, Orientation: EAST
Name: BACK (159 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST
E] Name: BACK 2X6 (106 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST
E] Name: RIGHT SIDE (21 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH
E] Name: SLIDER {40 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH
E] Name: LEFT SIDE (53 s.f.), J:0.310, SHGC: 0.28, Orientation: SOUTH
El Name: LEFT BSMT (20 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH
El Name: RIGHT BSMT (5 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
M Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95 AFUE
E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control 3
Energy Code Inspection Checklist
Property
3291 TAMERLANE PL
CARMEL, IN 46074
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
TLRO10 (AS DESIGNED)
TALLYNS RIDGE 10 Builder
FISCHER HOMES
Inspection Status
Results are projected
ElTest Status: Blower -door tested
House is air -sealed as to achieve 4,482 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 239.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 383.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage t= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
C-M
Energy Solutions
Property Organization
3291 TAMERLANE PL TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Michael Hill Inspection Status
TLR010 [AS DESIGNED] Results are projected
TALLYNS RIDGE 10 Builder
FISCHER HOMES
General Building Information
Number Of Bedrooms 4
Number Of Floors 2
Conditioned Floor Area [sq. ft.] 4;798
Unconditioned, attached garage? Yes
Conditioned Volume [cu. ft.] 44;822
Total Units in Building 1
Residence Type Single family detached
Model CLAYTON (AC)
Community TALLYNS RIDGE 10
Climate Zone 5A
Basement Wali
Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing
CONDIAMB R-10 Draped, 4f[ 1 8 168 Exposed Exterior Conditioned Space
CONDIGAR R-10 Draped, 4f[ 1 8 42 Exposed Exterior CDndttioned Space
Basement Wall Library List
Name Feet From Wall Tap To Insulation Feet From Wall Top To Insulation Is Fully Insulated R-value
Top Bottom
R-10 Draped, 4f[ 0 4 No 1000
Sla
Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated 210 Below Grade 0 0 1,707.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Library List
Name Wall Construction Type Slab Complete l Underslab Insulation Perimeter Insulation Perimeter Insulation R R-value
Insulated. Width [it] Depth [ft] Value
Uninsulated Wood Frame / Other No 0 0 D 0.00
1
Building Summary
Property
Organization
3291 TAMERLANE PL
TSI Energy Solutions
CARMEL, IN 46074
317-846-4655
CONDIAMB
Michael Hill
TLR010 [AS DESIGNED]
TALLYNS RIDGE 10
Builder
CONDIATTIC
FISCHER HOMES
Framed
Name Library Type
Cal
OVER AMBIENT R-30, GRI
G1 R-19, OSB
42.0 sq. 11
OVER GARAGE R-30, GR1
Unconditioned, attached garage
Rim Joist Library List
Framed Floor Library List
Name
R -value
R-30, GR1
Name
27.493
Rim Joist
C-M,
Energy Solutions
Inspection Status
Results are projected
e Surface Area Location
123 Above Grade 28.0 sq. fL Exposed Exterior
1.23 Above Grade 321.0 sq. fL Unconditioned, attached
garage
Name
Library Type
Surface Area
Location
CONDIAMB
G1 R-19, OSB
251.0 sq. ft.
Exposed Exterior
CONDIATTIC
G1 R-19, OSB
58.0 sq. ft.
Attic
CONDIGAR
G1 R-19, OSB
42.0 sq. 11
Unconditioned, attached garage
Rim Joist Library List
Name
R -value
G1 R-19, OSB
15.414
Wall
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
G1 R-15 BATT, T -PLY
Medium
2,433.0 sq. ft.
Exposed Exterior
CONDIAMB 2X6
G1 R-19 BATT, T- PLY
Medium
363.0 sq. ft.
Exposed Exterior
CONDIATTIC
G11 R-15 BATT, T -PLY
Medium
214.0 sq. ft.
Attic
2
Building Summary
Property
3291 TAMERLANE PL
CARMEL, IN 46074
TLR010 [AS DESIGNED]
TALLYNS RIDGE 10
Name
CONDIGAR G1 R-15 Gar Walls
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Library Type
Wall Library List
Name
R -value
G1 R-15 BATT, T -PLY
12.842
G1 R-15 Gar Walls
11.972
G1 R-19 BATT, T -PLY
17278
Glazing
C-M,Eneergy Solutions
Inspection Status
Resuhs are projected
Surface Calor Surface Area Location
Medium 378.0 sq. ft- Unconditioned, attached garage
Name
Library Type Wall Assignment
Basement Wall Overhang Depth
Assignment
Overhang Ft To
Top
Overhang Ft To
Bottom
Orientation
Surface Area
BACK
11-.31, SHGG28
CONDIAMB
0
0
0
'Nest
159.0 sq. R.
BACK 2X6
111-.31, SHGG28
CONDIAMB 2716
0
0
0
West
106.0 sq. ft.
FRONT
111-.31, SHGG28
CONDIAMB
0
0
0
East
130.0 sq. R.
LEFT BSMT
111-.31, SHGG28
CONDIAMB 0
0
0
South
20.0 sq. R
LEFT SIDE
11-31, SHGG28
CONDIAMB
0
0
❑
South
53.0 sq. R
RIGHT BSMT
11-31, SHGG28
CONDIAMB 0
0
❑
North
5.0 sq. ft.
RIGHT SIDE
11-31, SHGG28
CONDIAMB
0
0
❑
North
21.0 sq. R
SLIDER
11-31, SHGG28
CONDIAMB
0
0
❑
North
40.0 sq. R
Glazing Library List
Name Shg c U fiactol
U-.31, SHGC-28 0.28 0.310
Building Summary
Property
Organization
3291 TAMERLANE PL
TSI Energy Solutions
CARMEL, IN 46074
317-846-4655
Michael Hill
TLR010 [AS DESIGNED]
TALLYNS RIDGE 10
Builder
FISCHER HOMES
I
Skylight
Skylight Library List
None
Opaque Door
Name Library Type Wall Assignment
Basement Wall
Assign ment
FRONT Steel Door
CONDIAMB
GARAGE Steel Door
CONDIGAR
Opaque Door Library List
r
Name
U •factor
S,:e-1 D:-::-: 1
0.182
C-M,
Energy Solutions
Inspection Status
Results are projected
Solar Surface Color Surface Area Location
Ab sorpta n ce
0.9 0.75 Medium 20.0 sq_ tt Exposed Exterior
0.9 0.75 Medium 18.0 sq_ 11 Exposed Exterior
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof
1 .11 Tiles
SECOND R-38 Blown, GR1 1,960
SUN ROOM R-38 Vaulted, GR1 102
Roof Insulation Library List
Name Has Radiant Barrier
R-38 Blown, GR1 No
R-38 Vaulted, GR1 No
n
No Medium 1.960.0 sq. fL Attic
No Medium 102.0 sq. fL Vaulted Roof
R -value
38268
32263
4
Building Summary
Property
3291 TAMERLANE PL
CARMEL, IN 46074
TLR010 [AS DESIGNED]
TALLYNS RIDGE 10
Whole House Infiltration)
nfiltration
' 6 ACH at 50 Pa
Mechanical Ventilation
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Inspection Status
Results are projected
Blower -door tested 4
Lighting
% Interior Fluorescent % Interior LED Lightin4
Lighting
0
Onsite Generation
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
or Fluorescent % Exterior LED Lighting
Lighting
fl 0
C-M,
Energy Solutions
Lighting - -
0 0
Building Summary
Property Organization
3291 TAMERLANE PL TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Michael Hill Inspection Status
TLR010 [AS DESIGNED] Results are projected
TALLYNS RIDGE 10 Builder
FISCHER HOMES
Conditioning Equipment
Name Library Type Heating Percent Load C
Air conditioner [2] GSX130601B 0%
C-M,
Energy Solutions
g Percent Lead Hot Water
100%
0%
Fuel-fred air GMH951155DX 100% 0% 0%
distribution [1]
Water Heating [3] ENT 50 100 0% 0% 100%
1
Equipment Type: ENT 50 100
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
Equipment Type: GMH951155DX
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95AFUE
Heating Capacity [kBtulh]
110
Use default EAE
Yes
EAE [kWh]
1;018
Equipment Type: G5X130601B
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
57
6
Building Summary
Property
3291 TAMERLANE PL
CARMEL, IN 46074
TLR010 [AS DESIGNED]
TALLYNS RIDGE 10
istribution System
Distribution Type
Heating Equipment
Cooling Equipment
Sq. Feet Served
# Return Grilles
Supply Duct R Value
Return Duct R Value
Supply Duct Area [sq. ft.]
Return Duct Area [sq. ft_]
Duct Leakage to Outdoors (CFM25)
Total Leakage
Total Leakage Duct Test Conditions
Use Default Flow Rate
Duct 1
Duct Location
Percent Supply Area
Percent Return Area
Duct 2
Duct Location
Percent Supply Area
Percent Return Area
Duct 3
Duct Location
Percent Supply Area
Percent Return Area
Duct 4
Duct Location
Percent Supply Area
Percent Return Area
Duct 5
Duct Location
Percent Supply Area
Percent Return Area
Duct 6
Duct Location
Percent Supply Area
Percent Return Area
Ceiling Fan
Has Ceiling Fan
Cfm Per Watt
F
Water Distribution
Organization
TSI Energy Solutions
317-846-4655
Michael Hill Inspection Status
Results are projected
Builder
FISCHER HOMES
Forced Air
Fuel -fired air distribution (1)
Air conditioner (2)
4798
4
30
30
971.6
719.7
239
383
Post -Construction
Yes
Conditioned Space
80
80
Attic (well vented; under insulation)
20
20
Conditioned Space
0
Conditioned Space
0
Conditioned Space
0
Conditioned Space
s
No
100
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
118
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length jft]
20
Drain Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
3291 TAMERLANE PL
CARMEL, IN 46074
TLR010 [AS DESIGNED]
TALLYNS RIDGE 10
Clothes
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Electric
2.62
Timer Controls
704 kWhlYear
0.081kWh
$23.00
$0.581Therm
2.874
0.331
Programmable thermostat?
Yes
Dishwasher Size
Standard
Dishwasher Efficiency
270 kWh
Range/Oven Fuel
Natural Gas
Convection Oven?
No
Induction Range?
No
Refrigerator Consumption
709 kWhlYear
Notes
Inspection Status
Results are projected
C-M,
Energy Solutions
L1