HomeMy WebLinkAboutTLR-010 ENERGYIECC 2009 Performance Compliance Property 3291 TAMERLANE PL CARMEL, IN 46074 TLR010 (AS DESIGNED) TALLYNS RIDGE 10 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,683 $241 $410 $2,334 $1,242 $0 $3,577 Requirements C4405.3 Performance-based compliance passes by 1.3% 402.4.12 Air Leakage Testing C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration U -Factor 40322 Duct Testing Mandatory Checklist R405.2 Duct Insulation C-M, Energy Solutions As Designer`! $1,671 $222 $410 $2,303 $1,242 $0 $3,546 Design exceeds requirements for IECC 2009 Performance compliance by 1.3%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 1115119 at 7:58 AM Ekotrope RATER - Version 3.1.0.2084 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 3291 TAMERLANE PL CARMEL, IN 46074 FISCHER HOMES Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-10 Framed Floor R-30 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U -Value: 0.31, SHGC: 0.28 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 239.0 CFM @ 25Pa Total Duct Leakage 383.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name Michael Hill Organization: TSI Energy Solutions Signature: Date: 1115/19 at 7:58 AM Ekotrope RATER - Version 3.1.0.2084 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property Organization 3291 TAMERLANE PL TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill TLRO10 (AS DESIGNED) TALLYNS RIDGE 10 Builder FISCHER HOMES General Building Information Conditioned Area (sq ft) 4,798 Conditioned Volume (cubic ft) 44,822 Insulated Shell Area (sq ft) 9,747 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (1,707 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: OVER GARAGE (3 21 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I El Name: OVER AMBIENT (28 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 168, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 10.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: GOND/GAR (Exterior Perimeter [ft]: 42, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 10.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (2,433 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 3291 TAMERLANE PL TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill TLRO10 (AS DESIGNED) TALLYNS RIDGE 10 Builder FISCHER HOMES El Name: CONDIAMB 2X6 (363 s.f.) R-0.41 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIGAR (378 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I El Name: CONDIATTIC (214 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist Name: CGNDIAMB (251 s.f.) R: 15.414 Name: CGNDIGAR (42 s.f.) R: 15.414 Name: CONDIATTIC (58 s.f.) R: 15.414 Roof El Name: SECOND (1,960 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I El Name: SUNROOM (102 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Inspection Status Results are projected C", Energy Solutions 2 Energy Code Inspection Checklist Property C-MEnergy Solutions Organization 3291 TAMERLANE PL TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Inspection Status Michael Hill Results are projected TLR010 (AS DESIGNED) TALLYNS RIDGE 10 Builder FISCHER HOMES Glazing E] Name: FRONT X130 s.f.), U: 0.310, SHGC: 0.28, Orientation: EAST Name: BACK (159 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST E] Name: BACK 2X6 (106 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST E] Name: RIGHT SIDE (21 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH E] Name: SLIDER {40 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH E] Name: LEFT SIDE (53 s.f.), J:0.310, SHGC: 0.28, Orientation: SOUTH El Name: LEFT BSMT (20 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH El Name: RIGHT BSMT (5 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment M Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95 AFUE E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control 3 Energy Code Inspection Checklist Property 3291 TAMERLANE PL CARMEL, IN 46074 Organization TSI Energy Solutions 317-846-4655 Michael Hill TLRO10 (AS DESIGNED) TALLYNS RIDGE 10 Builder FISCHER HOMES Inspection Status Results are projected ElTest Status: Blower -door tested House is air -sealed as to achieve 4,482 CFM50 (6.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 239.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 383.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage t= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary C-M Energy Solutions Property Organization 3291 TAMERLANE PL TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill Inspection Status TLR010 [AS DESIGNED] Results are projected TALLYNS RIDGE 10 Builder FISCHER HOMES General Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 4;798 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 44;822 Total Units in Building 1 Residence Type Single family detached Model CLAYTON (AC) Community TALLYNS RIDGE 10 Climate Zone 5A Basement Wali Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-10 Draped, 4f[ 1 8 168 Exposed Exterior Conditioned Space CONDIGAR R-10 Draped, 4f[ 1 8 42 Exposed Exterior CDndttioned Space Basement Wall Library List Name Feet From Wall Tap To Insulation Feet From Wall Top To Insulation Is Fully Insulated R-value Top Bottom R-10 Draped, 4f[ 0 4 No 1000 Sla Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 210 Below Grade 0 0 1,707.0 sq. ft. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Type Slab Complete l Underslab Insulation Perimeter Insulation Perimeter Insulation R R-value Insulated. Width [it] Depth [ft] Value Uninsulated Wood Frame / Other No 0 0 D 0.00 1 Building Summary Property Organization 3291 TAMERLANE PL TSI Energy Solutions CARMEL, IN 46074 317-846-4655 CONDIAMB Michael Hill TLR010 [AS DESIGNED] TALLYNS RIDGE 10 Builder CONDIATTIC FISCHER HOMES Framed Name Library Type Cal OVER AMBIENT R-30, GRI G1 R-19, OSB 42.0 sq. 11 OVER GARAGE R-30, GR1 Unconditioned, attached garage Rim Joist Library List Framed Floor Library List Name R -value R-30, GR1 Name 27.493 Rim Joist C-M, Energy Solutions Inspection Status Results are projected e Surface Area Location 123 Above Grade 28.0 sq. fL Exposed Exterior 1.23 Above Grade 321.0 sq. fL Unconditioned, attached garage Name Library Type Surface Area Location CONDIAMB G1 R-19, OSB 251.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-19, OSB 58.0 sq. ft. Attic CONDIGAR G1 R-19, OSB 42.0 sq. 11 Unconditioned, attached garage Rim Joist Library List Name R -value G1 R-19, OSB 15.414 Wall Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-15 BATT, T -PLY Medium 2,433.0 sq. ft. Exposed Exterior CONDIAMB 2X6 G1 R-19 BATT, T- PLY Medium 363.0 sq. ft. Exposed Exterior CONDIATTIC G11 R-15 BATT, T -PLY Medium 214.0 sq. ft. Attic 2 Building Summary Property 3291 TAMERLANE PL CARMEL, IN 46074 TLR010 [AS DESIGNED] TALLYNS RIDGE 10 Name CONDIGAR G1 R-15 Gar Walls Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Library Type Wall Library List Name R -value G1 R-15 BATT, T -PLY 12.842 G1 R-15 Gar Walls 11.972 G1 R-19 BATT, T -PLY 17278 Glazing C-M,Eneergy Solutions Inspection Status Resuhs are projected Surface Calor Surface Area Location Medium 378.0 sq. ft- Unconditioned, attached garage Name Library Type Wall Assignment Basement Wall Overhang Depth Assignment Overhang Ft To Top Overhang Ft To Bottom Orientation Surface Area BACK 11-.31, SHGG28 CONDIAMB 0 0 0 'Nest 159.0 sq. R. BACK 2X6 111-.31, SHGG28 CONDIAMB 2716 0 0 0 West 106.0 sq. ft. FRONT 111-.31, SHGG28 CONDIAMB 0 0 0 East 130.0 sq. R. LEFT BSMT 111-.31, SHGG28 CONDIAMB 0 0 0 South 20.0 sq. R LEFT SIDE 11-31, SHGG28 CONDIAMB 0 0 ❑ South 53.0 sq. R RIGHT BSMT 11-31, SHGG28 CONDIAMB 0 0 ❑ North 5.0 sq. ft. RIGHT SIDE 11-31, SHGG28 CONDIAMB 0 0 ❑ North 21.0 sq. R SLIDER 11-31, SHGG28 CONDIAMB 0 0 ❑ North 40.0 sq. R Glazing Library List Name Shg c U fiactol U-.31, SHGC-28 0.28 0.310 Building Summary Property Organization 3291 TAMERLANE PL TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill TLR010 [AS DESIGNED] TALLYNS RIDGE 10 Builder FISCHER HOMES I Skylight Skylight Library List None Opaque Door Name Library Type Wall Assignment Basement Wall Assign ment FRONT Steel Door CONDIAMB GARAGE Steel Door CONDIGAR Opaque Door Library List r Name U •factor S,:e-1 D:-::-: 1 0.182 C-M, Energy Solutions Inspection Status Results are projected Solar Surface Color Surface Area Location Ab sorpta n ce 0.9 0.75 Medium 20.0 sq_ tt Exposed Exterior 0.9 0.75 Medium 18.0 sq_ 11 Exposed Exterior Roof Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof 1 .11 Tiles SECOND R-38 Blown, GR1 1,960 SUN ROOM R-38 Vaulted, GR1 102 Roof Insulation Library List Name Has Radiant Barrier R-38 Blown, GR1 No R-38 Vaulted, GR1 No n No Medium 1.960.0 sq. fL Attic No Medium 102.0 sq. fL Vaulted Roof R -value 38268 32263 4 Building Summary Property 3291 TAMERLANE PL CARMEL, IN 46074 TLR010 [AS DESIGNED] TALLYNS RIDGE 10 Whole House Infiltration) nfiltration ' 6 ACH at 50 Pa Mechanical Ventilation Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Inspection Status Results are projected Blower -door tested 4 Lighting % Interior Fluorescent % Interior LED Lightin4 Lighting 0 Onsite Generation None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List or Fluorescent % Exterior LED Lighting Lighting fl 0 C-M, Energy Solutions Lighting - - 0 0 Building Summary Property Organization 3291 TAMERLANE PL TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill Inspection Status TLR010 [AS DESIGNED] Results are projected TALLYNS RIDGE 10 Builder FISCHER HOMES Conditioning Equipment Name Library Type Heating Percent Load C Air conditioner [2] GSX130601B 0% C-M, Energy Solutions g Percent Lead Hot Water 100% 0% Fuel-fred air GMH951155DX 100% 0% 0% distribution [1] Water Heating [3] ENT 50 100 0% 0% 100% 1 Equipment Type: ENT 50 100 Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 Equipment Type: GMH951155DX Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95AFUE Heating Capacity [kBtulh] 110 Use default EAE Yes EAE [kWh] 1;018 Equipment Type: G5X130601B Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 57 6 Building Summary Property 3291 TAMERLANE PL CARMEL, IN 46074 TLR010 [AS DESIGNED] TALLYNS RIDGE 10 istribution System Distribution Type Heating Equipment Cooling Equipment Sq. Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply Duct Area [sq. ft.] Return Duct Area [sq. ft_] Duct Leakage to Outdoors (CFM25) Total Leakage Total Leakage Duct Test Conditions Use Default Flow Rate Duct 1 Duct Location Percent Supply Area Percent Return Area Duct 2 Duct Location Percent Supply Area Percent Return Area Duct 3 Duct Location Percent Supply Area Percent Return Area Duct 4 Duct Location Percent Supply Area Percent Return Area Duct 5 Duct Location Percent Supply Area Percent Return Area Duct 6 Duct Location Percent Supply Area Percent Return Area Ceiling Fan Has Ceiling Fan Cfm Per Watt F Water Distribution Organization TSI Energy Solutions 317-846-4655 Michael Hill Inspection Status Results are projected Builder FISCHER HOMES Forced Air Fuel -fired air distribution (1) Air conditioner (2) 4798 4 30 30 971.6 719.7 239 383 Post -Construction Yes Conditioned Space 80 80 Attic (well vented; under insulation) 20 20 Conditioned Space 0 Conditioned Space 0 Conditioned Space 0 Conditioned Space s No 100 Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 118 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length jft] 20 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 3291 TAMERLANE PL CARMEL, IN 46074 TLR010 [AS DESIGNED] TALLYNS RIDGE 10 Clothes Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Electric 2.62 Timer Controls 704 kWhlYear 0.081kWh $23.00 $0.581Therm 2.874 0.331 Programmable thermostat? Yes Dishwasher Size Standard Dishwasher Efficiency 270 kWh Range/Oven Fuel Natural Gas Convection Oven? No Induction Range? No Refrigerator Consumption 709 kWhlYear Notes Inspection Status Results are projected C-M, Energy Solutions L1