S101.0
13'-118"1 FRAMING SECTION 2x8 R A FT ER S 16" O.C. TRUSSES 24" o.c. T.C. L.L. 30 PSF T.C. D.L. 10 PSF B.C. D.L. 10 PSF B.C. L.L. 0 PSF TOTAL 50 PSF NOTE: TRUSS DESIGN BY MFG. FAMILY ROOM ENTRY FOYER COVERED TERRACE COVERED FRONT PORCH ASPHALT SHINGLES 7 16 " DECKING 15# ASPHALT SAT. FELT, EXCEPT IN HIGH RISK AREAS USE ICE & WATER SHIELD MEMBRANE 2 PLY"x117 8" LVL HDR. 2 PLY"x117 8" LVL HDR. 2 PLY"x24" LVL HDR. 2 PLY"x91 2 " LVL HDR. 12 PITCH9 1'-41 4" 31 2"10'-6" SEAT CUT 1'-01 2"31 2"18'-21 4" 111 4" 21'-9"10'-61 2" 51 2"1'-3" 2x8 RAFTERS 16" O.C. SEAT CUT SEAT CUT 12 PITCH23 4 3 4" T&G OSB SUB. FL. 14 JST @ 16" O.C. 2x6 JOIST 24" O.C. 2x6 RAFTERS 24" O.C.112" 178" 10'-9316"SLOPE STEP 3'-111516" 16'-334"8716"HEELHEIGHT10'-118" 1'-058" 9'-118"8'-634"14'-4316"2x8 JOIST 16" O.C.112" 2116"STEP SLOPE12'-418"12 PITCH 5 1'-234" 3'-112" 6 MIL POLYETHYLENE VAPOR BARRIER 8" CONC. WALL (2) ROWS OF #4 HORZ. REBARS LAP 24 AS NECESSARY 2" RIGID INSULATION3'-0"RUBBER FLASHING AS PER CONTR. RUBBER FLASHING AS PER CONTR. INSUL. BATTS 1'-1138" 20'-31116"1'-0" 1'-0"2'-0"2'-0"INSULATION BAFFLE STOP 2x4 NAILER BLOWN INSUL. R-50 9'-11" 1'-31116"DRAFT STOP 3PLYx14 LVL HEADER FULL THK FRICTION FIT FIBERGL INSUL. BATTS R-19 2x6 STUDS 16" O.C. w/ 1 2" DRYWALL 7/16" O.S.B. SHEATHING ZIP WALL W/ TAPPED JOINTS TOP OF RIDGE BEAM 4" CONC. BLK. 2 PLY"x91 2 " LVL HDR. 2 PLY"x117 8" LVL HDR.10'-934"BOT. OF LOOKOUT 11'-9"BOT. OF LOOKOUT POURED CONCRETEWALL HEIGHTH. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720 - Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174 - www.hgmccullough.comGARY NANCE DESIGN Architectural Concepts ByMake yourself at home4631LisbornDriveCarmel,IN46033 317.663.4793Pgnance@garynancedesign.comgarynancedesign.com ThesedesignconceptsarethepropertyofGaryNanceDesign andmaynotbeusedwithoutapprovalfromGaryNanceDesign Designed For:287 WSVSavader/SchragerDate: 01-10-19Plan number #180628 2 FRAMING SECTION TRUSSES 24" o.c. T.C. L.L. 30 PSF T.C. D.L. 10 PSF B.C. D.L. 10 PSF B.C. L.L. 0 PSF TOTAL 50 PSF NOTE: TRUSS DESIGN BY MFG. COVERED FRONT PORCH COVERED TERRACE FAMILY ROOM DINING ROOM BEDROOM #2 HALL CLOSET 13'-118" 3'-111516"14'-1"112" 2116"STEPSLOPE12'-418"2x8 RAFTERS 16" O.C.HEELHEIGHT1'-3" 51 2"10'-61 2" 18'-9 5 16" 2'-1111 16"20'-5"101 2" 2 PLY"x91 2 " LVL HDR. 1'-41 4"31 2" 9'-6" SEAT CUT 12 PITCH 2 3 4 2x6 JOIST 24" O.C. 2x6 RAFTERS 24" O.C.112"178"10'-9316"SLOPESTEP RUBBER FLASHING AS PER CONTR. INSUL. BATTS 1'-0" 2'-0"9'-11"1'-31116"2 PLY"x117 8" LVL HDR. 2 PLY"x117 8" LVL HDR.3'-112"8" CONC. WALL (2) ROWS OF #4 HORZ. REBARS LAP 24 AS NECESSARY2" RIGID INSULATION 3'-0"POURED CONCRETEWALL HEIGHT1'-234" 10'-118"1'-058" 9'-118"3 4" T&G OSB SUB. FL. 14 JST @ 16" O.C. 3 4" T&G OSB SUB. FL. 117 8 JST @ 16" O.C. 2 PLY"x24" LVL HDR.1'-1138"15'-10316"BLOWN INSUL. R-50 DRAFT STOP 3PLYx14 LVL HEADER SEAT CUT FULL THK FRICTION FIT FIBERGL INSUL. BATTS R-15 2x4 STUDS 16" O.C. w/ 1 2" DRYWALL AIR SPACE BRICK VENEER 12 PITCH9 12 PITCH5 20"x8" CONCRETE FOOTING @ 2500 PSI TOP OF TRUSS RUBBER FLASHING AS PER CONTR. 4" CONC. BLK. 4" CONC. BLK. TRUSSES 24" o.c. T.C. L.L. 30 PSF T.C. D.L. 10 PSF B.C. D.L. 10 PSF B.C. L.L. 0 PSF TOTAL 50 PSF NOTE: TRUSS DESIGN BY MFG. 4" (MIN.) GRAVEL FILL 6 MIL POLYETHYLENE VAPOR BARRIER 4" CONC. SLAB W/ 6x6 #10 WWF 2" MINIMUM SLOPED CONCRETE SLAB 1 2" EDGEHEELHEIGHTBLOWN INSUL. R-50 ZIP WALL W/ TAPPED JOINTS 7/16" O.S.B. SHEATHING AIR SPACE BRICK VENEER 10'-118" 2'-0"8 FRAMING SECTION 2 PLY"x16" LVL HDR. ASPHALT SHINGLES 7 16 " DECKING 15# ASPHALT SAT. FELT, EXCEPT IN HIGH RISK AREAS USE ICE & WATER SHIELD MEMBRANE 12 9PITCH 1'-5"11'-71 2" 11'-71 2"1'-5"3'-018" 11'-712"12"20"x8" CONCRETE FOOTING @ 2500 PSI TOP OF MAIN LEVEL SUB FLOOR 2 CAR GARAGE 11'-112"BOT. OF LOOKOUT 08SCALE: 1/4"=1'-0"FRAMING SECTIONS SHEET NUMBER 02/08/19 William Hohlt