Loading...
HomeMy WebLinkAboutGN010.0 TSIIECC 2009 Performance Compliance Property 1205 WESTVALE DR CARMEL, IN 46032 Organization TSI Energy Solutions Matthew Timmons Inspection Status Results are projected JGW287 (AS DESIGNED) Builder WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Annual Energy Cast IECC 2009 Performance $2,212 $317 $330 $2,859 $1,577 $0 $4,435 Requirements C4405.3 Performance-based compliance passes by 0.4% 402.4.12 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U -Factor 40322 Duct Testing Mandatory Checklist R405.2 Duct Insulation C-M, Energy Solutions As Designed $2,244 $274 $330 $2,848 $1,577 $D $4,425 Design exceeds requirements for IECC 2009 Performance compliance by 0.4%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be vertned as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 12/18/18 at 4:49 PM Ekotrope RATER - Version 3.1.0.2070 IECC 2009 Performance compliance results calculated using Ekotrope s energy algorithm; which is a RESNET Accredited HERS Rating Tool. 7205 WESTVALE DR CARMEL, IN 46032 HOMES BY McKENZIE, INC Ceiling Attic, R-50 Above Grade Walls R-15 Foundation Walls R-10 Framed Floor N/A Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.29, SHGC: 0.27 Building Features Duct Supply R-6.0, Return R-0.0 Duct Leakage to Outside 250.0 CFM cQ 25 Pa Total Duct Leakage 400.0 CFM cQ 25 Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Narne: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 12118/18 at 4:49 P10 Ekotrope RATER - Version 3.1.0.2070 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESNETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 1205 WESTVALE DR CARMEL, IN 46032 Organization TSI Energy Solutions Matthew Timmons JGW287 (AS DESIGNED) Builder WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC General Building Information Conditioned Area (sq ft; 6,772 Conditioned Volume (cubic ft) 75,883 Insulated Shell Area (sq fl) 14,116 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: BSMT (1,230 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Name: CRAWL (2,116 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Name: CRAWL (491 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall Name: CON DIAMB (Exterior Perimeter [ft]: 23, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 0.00 Fully insulated (top to bottom) ]l Name: CRAWUAMB (Exterior Perimeter [ft]: 170, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2) R: 10.00 Fully insulated (top to bottom) Name: CRAWUAMB (Exterior Perimeter [ft]: 66, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2) R: 10.00 Fully insulated (top to bottom) 1 Energy Code Inspection Checklist Property 1205 WESTVALE DR CARMEL, IN 46032 Organization TSI Energy Solutions Matthew Timmons JGW287 (AS DESIGNED) Builder WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC Inspection Status Results are projected C-M, Energy Solutions ] Name: CRAWL/GAR (Exterior Perimeter [ft]: 3, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2) R: 10.00 Fully insulated (top to bottom) ]l Name: CON DIGAR (Exterior Perimeter [ft]: 56, Height Above Grade [ft]; 1, Depth Below Grade [ft]; 2) R: 10.00 Fully insulated (top to bottom) Above Grade Wall ] Name: CONDIAMB (3,438 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I ]] Name: CONDIGAR (590 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I ] Name: CONDIATTIC (826 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist El Name: RIM CONDIAMB (259 s.f.) R: 11.691 El Name: BAND CON DIAMB (60 s.f.) R: 11.691 El Name: CONDIGAR (59 s.f.) R: 11.691 ]] Name: CONDIATTIC (118 s.f.) R: 11.691 Roof ] Name: MAIN (3,837 s.f.) 2 R-39.73 continuous insulation; R-10.15 cavity insulation Insulation Grade: I Energy Code Inspection Checklist C-M Energy Solutions Property Organization 1205 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status Results are projected JGW287 (AS DESIGNED) Builder WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC Opaque Door Name: FRONT (48 s.f.) U: 0.476 Name: GARAGE (24 s.f.) U: 0.182 Glazing El Name: FRONT (166 s.f.), U: 0.290, SHGC: 0.27, Orientation: EAST El Name: BACK (148 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST El Name: GD (120 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST El Name: LEFT SIDE (57 s.f.), U:0.290, SHGC: 0.27, Orientation: SOUTH Name: GD (72 s.f.), U:0.290, SHGC: 0.27, Orientation: SOUTH Name: LEFT BSMT (15 s.f.), U:0.290, SHGC: 0.27, Orientation: SOUTH Name: RIGHT SIDE (102 s.f.), U:0.290, SHGC: 0.27, Orientation: NORTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El HEATING 1 • Natural Gas • 60% Heating Load @ 92.1 AFUE El HEATING 2 • Natural Gas • 40% Heating Load @ 92.1 AFUE 3 Energy Code Inspection Checklist Property 1205 WESTVALE DR CARMEL, IN 46032 Organization TSI Energy Solutions Matthew Timmons Inspection Status Results are projected JGW287 (AS DESIGNED) Builder WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC El AC 1 • Electric • 60% Cooling Load @ 13 SEER El AC 2 • Electric • 40% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 6,324 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 Entirely within conditioned space Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 250.0 CFM @ 25 Pascals Total Duct Leakage is specified in Ekotrope at 400.0 CFM @ 25 Pascals Duct System 2 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 85.0 CFM @ 25 Pascals Total Duct Leakage is specified in Ekotrope at 136.0 CFM @ 25 Pascals C-M, Energy Solutions 4 Energy Code Inspection Checklist Property 1205 WESTVALE DR CARMEL, IN 46032 Organization TSI Energy Solutions Matthew Timmons JGW287 (AS DESIGNED) Builder WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C-M, Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 5 Building Summary Property Organization C-MEnergy Solutions 1205 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status JGW287 [AS DESIGNED] Builder Results are projected WESTVALE AT JACKSON GRANT 287 HOMES BY McKENZIE, JNC General Building Information MM Number Of Bedrooms 3 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 65,772 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 75,883 Total Units in Building 1 Residence Type Single family detached Model SAVADERISCHRAQER RESIDENCE Community WESTVALE AT JACKSON GRANT 287 Climate Zone 5A Basement Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB Uninsulated 1 8 23 Exposed Exterior Conditioned Space CONDIGAR R-10 Draped, Full 1 2 56 Exposed Exterior Conditioned Crawlspace CRAWL/AMB R-10 Draped, Full 1 2 170 Exposed Exterior Conditioned Crawlspace CRAWL/AM13 R-10 Draped, Full 1 2 66 Exposed Exterior Conditioned Crawlspace CRAWL/GAR R-10 Draped, Full 1 2 3 Exposed Exterior Conditioned Crawlspace Basement Wall Library List Name Feet From Wall Top To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R -value Top Bottom R-10 Draped, Full NIA NIA Yes 10.00 Uninsulated NIA NIA Yes 0.00 Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 79 Below Grade 0 0 1.230.0 sq. R. Exposed Exterior Conditioned Space CRAWL Uninsulated 173 Below Grade ❑ 0 2,116.0 sq. R Exposed Exterior Conditioned Crawlspace CRAWL Uninsulated 66 Below Grade ❑ ❑ 491.0 sq. R. Exposed Exterior Conditioned Crawlspace 1 Building Summary Property Organization 12❑5 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status JGW287 [AS DESIGNED] Builder Results are projected WESTVALE AT JACKSON GRANT 287 HOMES BY McKENZIE, INC lab Library List Name Wali C C-M, Energy Solutions IUninsulated Woad Frame / Other No ❑ 0 0 0.00 Framed Floor None Present I Framed Floor Library List None Present Rim Joist Name Library Type Surface Area Location BAND CONDIAMB G1 R-15, OSB 60 sq. ft. Exposed Exterior CONDIATTIC G1 R-15, OSB 118.0 sq. ft. Attic CONDIGAR G1 R-15, OSB 59.0 sq. ft. Unconditioned, attached garage RIM CONDIAMB G1 R-15, OSB 259_0 sq. 11 Exposed Exterior Rim Joist Library List Name R -value G1 R-15, OSB 11.G91 Surface Calor Surface Area Location Medium 3,438.0 sq. ft. Exposed Exterior Building Summary C-M Energy Solutions Property Organization 1265 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status JGW287 [AS DESIGNED] Builder Results are projected WESTVALE AT JACKSON GRANT 287 HOMES BY McKENZIE, JNC Name Library Type Surface Calor Surface Area Location CONDIATTIC G1 R-15 BATT, OSB Medium 826.0 sq. ft. Attic CONDIGAR G1 R-15 Gar Walls Medium 590.0 sq. ft. Unconditioned, attached garage Wall Library List Name R -value G1 R-15 BATT, OSB 13.423 G1 R-15 Gar Walls 11.972 Glazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft Te Overhang Ft Te Orientation Surface Area Assignment Top Bottom BACK U-29, SHGG27 CONDIAMB 0 0 0 West 148.0 sq. 11 FRONT U-29, SHGG27 CONDIAMB 0 0 0 East 166.0 sq. ft. GD U-29, SHGG27 CONDIAMB 0 0 0 West 1200.sq. 11 GD U-29, SHGG27 CONDIAMB 0 0 0 South 72.0 sq. fl- LEFT tLEFT IBS MT U-29, SHGG27 CONDIAMB 0 0 0 South 15.0 sq. 1 LEFT SIDE U-29, SHGG27 CONDIAMB 0 0 0 South 57.0 sq. R RIGHT SIDE U-29, SHGG27 CONDIAMB 0 0 0 North 102.0 sq. ft. Glazing Library List Name Shg c U -factor 111-29,SHGC-27 027 0290 Skylight None Present Building Summary Property Organization 1205 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status JGW287 [AS DESIGNED] Builder Results are projected WESTVALE AT JACKSON GRANT 287 HOMES BY McKENZIE, JNC kylight Library List mA None Opaque Door Name Library Type Wall Assignmen, FRONT Woad Door CONDIAMB GARAGE Steel Door CONDIGAR Opaque Door Library List Name Steel Door Woad Door Roof Insulation Name Library Type Attic E MAIN R-50 Blown. GR1 sement Wall Assignment Roof Insulation Library List _ Name Has Radiant Barrier No Whale House Infiltration Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested U -factor 0.182 0.476 Solar Ab sorpta n ce C-M, Energy Solutions r su dace Area 1 -0 -Cation 0.9 0.75 Medium 48.0 sq- ft Exposed Exterior 0.9 0.75 Medium 24.0 sq- ft Exposed Exterior lrea Clay or Concrete Root �.t.] Tiles It 3,837 No Medium 3.837.0 sq. ft Attic 50.474 W Shelter Class 4 4 Building Summary Property 1205 WESTVALE DR CARMEL, IN 46032 JGW287 [AS DESIGNED] WESTVALE AT JACKSON GRANT 287 Mechanical Ventilation Lighting o Interior Fluorescent ILighting Onsite Generation Organization TSI Energy Solutions Matthew Timmons Builder HOMES BY McKENZIE, JNC None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present or Fluorescent Lighting Inspection Status Results are projected 0 C-M, Energy Solutions Lighting 0 0 �J Building Summary C-M Energy Solutions Property Organization 1265 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Inspection Status JGW287 [AS DESIGNED] Builder Results are projected WESTVALE AT JACKSON GRANT 287 HOMES BY McKENZIE, JNC itivning Equipment Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load AC 1 13ACX-042-230 0% _c% 0% AC 2 13ACX-042-230 0% 41-1 1% 0% HEATING 1 9125A481ODS17 60% 0% 0% HEATING 2 9125A4206OS17 40% 0% 0% Vater Heating RE350" 0% 0% 100% Equipment Type: 13ACX-042-230 Fuel Type Electric Distribution Type Forced Air Motor Type PSC (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 41.5 ■ Equipment Type: 912SA4206OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSC (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 57 Use default EAE Yes EAE [kWh] 7361 Equipment Type: 9125A4810OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSC (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 93 Use default EAE No EAE [kWh] 756 6 Building Summary Property 1205 WESTVALE DR CARMEL, IN 46032 JGW287 [AS DESIGNED] WESTVALE AT JACKSON GRANT 287 quipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Distribution System Distribution Type Heating Equipment Cooling Equipment Sq. Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply Duct Area [sq. ft.] Return Duct Area [sq. ft_] Duct Leakage to Outdoors (CFM25) Total Leakage [CFM&nbsp;@&nbsp;25Pa] Total Leakage Duct Test Conditions Use Default Flow Rate Duct 1 Duct Location Percent Supply Area Percent Return Area Duct2 Duct Location Percent Supply Area Percent Return Area Duct 3 Duct Location Percent Supply Area Percent Return Area Duct4 Duct Location Percent Supply Area Percent Return Area Duct 5 Duct Location Percent Supply Area Percent Return Area Duct6 Duct Location Percent Supply Area Percent Return Area Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected HOMES BY McKENZIE, JNC Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 W 19 Forced Air HEATING 1 AC 1 5067 5 6 6 1368.09 1266.75 250 400 Post -Construction Yes Attic (well vented, under insulation) 0 0 Conditioned Space 100 100 Conditioned Space 0 0 Conditioned Space 0 0 Conditioned Space 0 0 Conditioned Space 0 0 C-M, Energy Solutions 7 Building Summary Property 1205 WESTVALE DR CARMEL, IN 46032 JGW287 [AS DESIGNED] WESTVALE AT JACKSON GRANT 287 ibution System Distribution Type Heating Equipment Cooling Equipment Sq. Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply Duct Area [sq. ft.] Return Duct Area [sq. ft.] Duct Leakage to Outdoors (CFM25) Total Leakage [CFM&nbsp;@&nbsp;25Pa] Total Leakage Duct Test Conditions Use Default Flow Rate Duct 1 Duct Location Percent Supply Area Percent Return Area Duct2 Duct Location Percent Supply Area Percent Return Area Duct 3 Duct Location Percent Supply Area Percent Return Area Duct 4 Duct Location Percent Supply Area Percent Return Area Duct 5 Duct Location Percent Supply Area Percent Return Area Duct6 Duct Location Percent Supply Area Percent Return Area Ceiling Fan Has Ceiling Fan Cfm Per Watt Water Distribution Organization TSI Energy Solutions Matthew Timmons Builder HOMES BY McKENZIE, JNC Forced Air HEATING 2 AC 2 1705 2 10 20 460.35 170.5 85 136 Post -Construction Yes Attic (well vented, under insulation) 50 95 Conditioned Space 50 5 Conditioned Space 0 0 Conditioned Space 0 0 Conditioned Space 0 0 Conditioned Space 0 0 Mm&h No Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 75 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 34 Drain Water Heat Recovery? No Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 1205 WESTVALE DR CARMEL, IN 46032 JGW287 [AS DESIGNED] WESTVALE AT JACKSON GRANT 287 Fuel Type Cef Field Utilization lothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption "M Organization TSI Energy Solutions Matthew Timmons Builder HOMES BY McKENZIE, JNC Electric Timer Controls 704 kWh/Year 0.081kWh $23.00 $0.58/Therm 2.874 0.33053 Yes Standard 270 kWh Electric No No 709 kWh/Year Inspection Status Results are projected C-M, Energy Solutions