HomeMy WebLinkAboutGN010.0 TSIIECC 2009 Performance Compliance
Property
1205 WESTVALE DR
CARMEL, IN 46032
Organization
TSI Energy Solutions
Matthew Timmons Inspection Status
Results are projected
JGW287 (AS DESIGNED) Builder
WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Annual Energy Cast
IECC 2009 Performance
$2,212
$317
$330
$2,859
$1,577
$0
$4,435
Requirements
C4405.3 Performance-based compliance passes by 0.4%
402.4.12 Air Leakage Testing
402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration U -Factor
40322 Duct Testing
Mandatory Checklist
R405.2 Duct Insulation
C-M,
Energy Solutions
As Designed
$2,244
$274
$330
$2,848
$1,577
$D
$4,425
Design exceeds requirements for IECC 2009 Performance compliance by 0.4%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be vertned as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
12/18/18 at 4:49 PM
Ekotrope RATER - Version 3.1.0.2070
IECC 2009 Performance compliance results calculated using Ekotrope s energy algorithm; which is a RESNET Accredited HERS Rating Tool.
7205 WESTVALE DR
CARMEL, IN 46032
HOMES BY McKENZIE, INC
Ceiling Attic, R-50
Above Grade Walls R-15
Foundation Walls R-10
Framed Floor N/A
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.29, SHGC: 0.27
Building Features
Duct Supply R-6.0, Return R-0.0
Duct Leakage to Outside 250.0 CFM cQ 25 Pa
Total Duct Leakage 400.0 CFM cQ 25 Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Narne: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 12118/18 at 4:49 P10
Ekotrope RATER - Version 3.1.0.2070
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESNETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
1205 WESTVALE DR
CARMEL, IN 46032
Organization
TSI Energy Solutions
Matthew Timmons
JGW287 (AS DESIGNED) Builder
WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC
General Building Information
Conditioned Area (sq ft; 6,772
Conditioned Volume (cubic ft) 75,883
Insulated Shell Area (sq fl) 14,116
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: BSMT (1,230 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Name: CRAWL (2,116 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Name: CRAWL (491 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
Name: CON DIAMB (Exterior Perimeter [ft]: 23, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 0.00
Fully insulated (top to bottom)
]l Name: CRAWUAMB (Exterior Perimeter [ft]: 170, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2)
R: 10.00
Fully insulated (top to bottom)
Name: CRAWUAMB (Exterior Perimeter [ft]: 66, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2)
R: 10.00
Fully insulated (top to bottom)
1
Energy Code Inspection Checklist
Property
1205 WESTVALE DR
CARMEL, IN 46032
Organization
TSI Energy Solutions
Matthew Timmons
JGW287 (AS DESIGNED) Builder
WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC
Inspection Status
Results are projected
C-M,
Energy Solutions
] Name: CRAWL/GAR (Exterior Perimeter [ft]: 3, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2)
R: 10.00
Fully insulated (top to bottom)
]l Name: CON DIGAR (Exterior Perimeter [ft]: 56, Height Above Grade [ft]; 1, Depth Below Grade [ft]; 2)
R: 10.00
Fully insulated (top to bottom)
Above Grade Wall
] Name: CONDIAMB (3,438 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
]] Name: CONDIGAR (590 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
] Name: CONDIATTIC (826 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
El Name: RIM CONDIAMB (259 s.f.)
R: 11.691
El Name: BAND CON DIAMB (60 s.f.)
R: 11.691
El Name: CONDIGAR (59 s.f.)
R: 11.691
]] Name: CONDIATTIC (118 s.f.)
R: 11.691
Roof
] Name: MAIN (3,837 s.f.) 2
R-39.73 continuous insulation; R-10.15 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
C-M
Energy Solutions
Property Organization
1205 WESTVALE DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons Inspection Status
Results are projected
JGW287 (AS DESIGNED) Builder
WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC
Opaque Door
Name: FRONT (48 s.f.)
U: 0.476
Name: GARAGE (24 s.f.)
U: 0.182
Glazing
El Name: FRONT (166 s.f.), U: 0.290, SHGC: 0.27, Orientation: EAST
El Name: BACK (148 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST
El Name: GD (120 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST
El Name: LEFT SIDE (57 s.f.), U:0.290, SHGC: 0.27, Orientation: SOUTH
Name: GD (72 s.f.), U:0.290, SHGC: 0.27, Orientation: SOUTH
Name: LEFT BSMT (15 s.f.), U:0.290, SHGC: 0.27, Orientation: SOUTH
Name: RIGHT SIDE (102 s.f.), U:0.290, SHGC: 0.27, Orientation: NORTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El HEATING 1 • Natural Gas • 60% Heating Load @ 92.1 AFUE
El HEATING 2 • Natural Gas • 40% Heating Load @ 92.1 AFUE 3
Energy Code Inspection Checklist
Property
1205 WESTVALE DR
CARMEL, IN 46032
Organization
TSI Energy Solutions
Matthew Timmons Inspection Status
Results are projected
JGW287 (AS DESIGNED) Builder
WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC
El AC 1 • Electric • 60% Cooling Load @ 13 SEER
El AC 2 • Electric • 40% Cooling Load @ 13 SEER
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 6,324 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
Entirely within conditioned space
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 250.0 CFM @ 25 Pascals
Total Duct Leakage is specified in Ekotrope at 400.0 CFM @ 25 Pascals
Duct System 2
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 85.0 CFM @ 25 Pascals
Total Duct Leakage is specified in Ekotrope at 136.0 CFM @ 25 Pascals
C-M,
Energy Solutions
4
Energy Code Inspection Checklist
Property
1205 WESTVALE DR
CARMEL, IN 46032
Organization
TSI Energy Solutions
Matthew Timmons
JGW287 (AS DESIGNED) Builder
WESTVALE AT JACKSON GRANT HOMES BY McKENZIE, INC
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C-M,
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
5
Building Summary
Property
Organization
C-MEnergy Solutions
1205 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Inspection Status
JGW287 [AS DESIGNED]
Builder Results are projected
WESTVALE AT JACKSON GRANT 287
HOMES BY McKENZIE, JNC
General Building Information
MM
Number Of Bedrooms
3
Number Of Floors
2
Conditioned Floor Area [sq. ft.]
65,772
Unconditioned, attached garage?
Yes
Conditioned Volume [cu. ft.]
75,883
Total Units in Building
1
Residence Type
Single family detached
Model
SAVADERISCHRAQER RESIDENCE
Community
WESTVALE AT JACKSON GRANT 287
Climate Zone
5A
Basement Wall
Name Library Type
Height Above Grade Depth Below Grade Perimeter Location Enclosing
CONDIAMB Uninsulated
1 8
23 Exposed Exterior Conditioned Space
CONDIGAR R-10 Draped, Full
1 2
56 Exposed Exterior Conditioned Crawlspace
CRAWL/AMB R-10 Draped, Full
1 2
170 Exposed Exterior Conditioned Crawlspace
CRAWL/AM13 R-10 Draped, Full
1 2
66 Exposed Exterior Conditioned Crawlspace
CRAWL/GAR R-10 Draped, Full
1 2
3 Exposed Exterior Conditioned Crawlspace
Basement Wall Library List
Name Feet From Wall Top To
Insulation Feet From Wall Top Tb Insulation
Is Fully Insulated R -value
Top Bottom
R-10 Draped, Full
NIA NIA
Yes 10.00
Uninsulated
NIA NIA
Yes 0.00
Name Library Type
Perimeter Floor Grade Carpet R Exposed
Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated
79 Below Grade 0 0
1.230.0 sq. R. Exposed Exterior Conditioned
Space
CRAWL Uninsulated
173 Below Grade ❑ 0
2,116.0 sq. R Exposed Exterior Conditioned
Crawlspace
CRAWL Uninsulated
66 Below Grade ❑ ❑
491.0 sq. R. Exposed Exterior Conditioned
Crawlspace
1
Building Summary
Property Organization
12❑5 WESTVALE DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Inspection Status
JGW287 [AS DESIGNED] Builder Results are projected
WESTVALE AT JACKSON GRANT 287 HOMES BY McKENZIE, INC
lab Library List
Name Wali C
C-M,
Energy Solutions
IUninsulated Woad Frame / Other No ❑ 0 0 0.00
Framed Floor
None Present
I
Framed Floor Library List
None Present
Rim Joist
Name Library Type Surface Area Location
BAND CONDIAMB G1 R-15, OSB 60 sq. ft. Exposed Exterior
CONDIATTIC
G1 R-15, OSB
118.0 sq. ft.
Attic
CONDIGAR
G1 R-15, OSB
59.0 sq. ft.
Unconditioned, attached garage
RIM CONDIAMB
G1 R-15, OSB
259_0 sq. 11
Exposed Exterior
Rim Joist Library List
Name R -value
G1 R-15, OSB 11.G91
Surface Calor Surface Area Location
Medium 3,438.0 sq. ft. Exposed Exterior
Building Summary
C-M
Energy Solutions
Property Organization
1265 WESTVALE DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Inspection Status
JGW287 [AS DESIGNED] Builder Results are projected
WESTVALE AT JACKSON GRANT 287 HOMES BY McKENZIE, JNC
Name Library Type Surface Calor Surface Area Location
CONDIATTIC G1 R-15 BATT, OSB Medium 826.0 sq. ft. Attic
CONDIGAR G1 R-15 Gar Walls Medium 590.0 sq. ft. Unconditioned, attached garage
Wall Library List
Name R -value
G1 R-15 BATT, OSB 13.423
G1 R-15 Gar Walls 11.972
Glazing
Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft Te Overhang Ft Te Orientation Surface Area
Assignment Top Bottom
BACK U-29, SHGG27 CONDIAMB 0 0 0 West 148.0 sq. 11
FRONT U-29, SHGG27 CONDIAMB 0 0 0 East 166.0 sq. ft.
GD U-29, SHGG27 CONDIAMB 0 0 0 West 1200.sq. 11
GD U-29, SHGG27 CONDIAMB 0 0 0 South 72.0 sq. fl-
LEFT
tLEFT IBS MT U-29, SHGG27 CONDIAMB 0 0 0 South 15.0 sq. 1
LEFT SIDE U-29, SHGG27 CONDIAMB 0 0 0 South 57.0 sq. R
RIGHT SIDE U-29, SHGG27 CONDIAMB 0 0 0 North 102.0 sq. ft.
Glazing Library List
Name Shg c U -factor
111-29,SHGC-27 027 0290
Skylight
None Present
Building Summary
Property Organization
1205 WESTVALE DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Inspection Status
JGW287 [AS DESIGNED] Builder Results are projected
WESTVALE AT JACKSON GRANT 287 HOMES BY McKENZIE, JNC
kylight Library List mA
None
Opaque Door
Name Library Type Wall Assignmen,
FRONT Woad Door CONDIAMB
GARAGE Steel Door CONDIGAR
Opaque Door Library List
Name
Steel Door
Woad Door
Roof Insulation
Name Library Type Attic E
MAIN R-50 Blown. GR1
sement Wall
Assignment
Roof Insulation Library List _
Name Has Radiant Barrier
No
Whale House Infiltration
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
U -factor
0.182
0.476
Solar
Ab sorpta n ce
C-M,
Energy Solutions
r su dace Area 1 -0 -Cation
0.9 0.75 Medium 48.0 sq- ft Exposed Exterior
0.9 0.75 Medium 24.0 sq- ft Exposed Exterior
lrea Clay or Concrete Root
�.t.] Tiles
It
3,837 No Medium 3.837.0 sq. ft Attic
50.474
W
Shelter Class
4
4
Building Summary
Property
1205 WESTVALE DR
CARMEL, IN 46032
JGW287 [AS DESIGNED]
WESTVALE AT JACKSON GRANT 287
Mechanical Ventilation
Lighting
o Interior Fluorescent
ILighting
Onsite Generation
Organization
TSI Energy Solutions
Matthew Timmons
Builder
HOMES BY McKENZIE, JNC
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
or Fluorescent
Lighting
Inspection Status
Results are projected
0
C-M,
Energy Solutions
Lighting
0
0
�J
Building Summary
C-M
Energy Solutions
Property Organization
1265 WESTVALE DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Inspection Status
JGW287 [AS DESIGNED] Builder Results are projected
WESTVALE AT JACKSON GRANT 287 HOMES BY McKENZIE, JNC
itivning Equipment
Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load
AC 1 13ACX-042-230 0% _c% 0%
AC 2 13ACX-042-230 0% 41-1 1% 0%
HEATING 1 9125A481ODS17 60% 0% 0%
HEATING 2 9125A4206OS17 40% 0% 0%
Vater Heating RE350" 0% 0% 100%
Equipment Type: 13ACX-042-230
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
41.5
■
Equipment Type: 912SA4206OS17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Heating Efficiency
92.1 AFUE
Heating Capacity [kBtulh]
57
Use default EAE
Yes
EAE [kWh]
7361
Equipment Type: 9125A4810OS17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Heating Efficiency
92.1 AFUE
Heating Capacity [kBtulh]
93
Use default EAE
No
EAE [kWh]
756
6
Building Summary
Property
1205 WESTVALE DR
CARMEL, IN 46032
JGW287 [AS DESIGNED]
WESTVALE AT JACKSON GRANT 287
quipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Distribution System
Distribution Type
Heating Equipment
Cooling Equipment
Sq. Feet Served
# Return Grilles
Supply Duct R Value
Return Duct R Value
Supply Duct Area [sq. ft.]
Return Duct Area [sq. ft_]
Duct Leakage to Outdoors (CFM25)
Total Leakage [CFM @ 25Pa]
Total Leakage Duct Test Conditions
Use Default Flow Rate
Duct 1
Duct Location
Percent Supply Area
Percent Return Area
Duct2
Duct Location
Percent Supply Area
Percent Return Area
Duct 3
Duct Location
Percent Supply Area
Percent Return Area
Duct4
Duct Location
Percent Supply Area
Percent Return Area
Duct 5
Duct Location
Percent Supply Area
Percent Return Area
Duct6
Duct Location
Percent Supply Area
Percent Return Area
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
HOMES BY McKENZIE, JNC
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
W 19
Forced Air
HEATING 1
AC 1
5067
5
6
6
1368.09
1266.75
250
400
Post -Construction
Yes
Attic (well vented, under insulation)
0
0
Conditioned Space
100
100
Conditioned Space
0
0
Conditioned Space
0
0
Conditioned Space
0
0
Conditioned Space
0
0
C-M,
Energy Solutions
7
Building Summary
Property
1205 WESTVALE DR
CARMEL, IN 46032
JGW287 [AS DESIGNED]
WESTVALE AT JACKSON GRANT 287
ibution System
Distribution Type
Heating Equipment
Cooling Equipment
Sq. Feet Served
# Return Grilles
Supply Duct R Value
Return Duct R Value
Supply Duct Area [sq. ft.]
Return Duct Area [sq. ft.]
Duct Leakage to Outdoors (CFM25)
Total Leakage [CFM @ 25Pa]
Total Leakage Duct Test Conditions
Use Default Flow Rate
Duct 1
Duct Location
Percent Supply Area
Percent Return Area
Duct2
Duct Location
Percent Supply Area
Percent Return Area
Duct 3
Duct Location
Percent Supply Area
Percent Return Area
Duct 4
Duct Location
Percent Supply Area
Percent Return Area
Duct 5
Duct Location
Percent Supply Area
Percent Return Area
Duct6
Duct Location
Percent Supply Area
Percent Return Area
Ceiling Fan
Has Ceiling Fan
Cfm Per Watt
Water Distribution
Organization
TSI Energy Solutions
Matthew Timmons
Builder
HOMES BY McKENZIE, JNC
Forced Air
HEATING 2
AC 2
1705
2
10
20
460.35
170.5
85
136
Post -Construction
Yes
Attic (well vented, under insulation)
50
95
Conditioned Space
50
5
Conditioned Space
0
0
Conditioned Space
0
0
Conditioned Space
0
0
Conditioned Space
0
0
Mm&h
No
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
75
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft] 34
Drain Water Heat Recovery? No
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
1205 WESTVALE DR
CARMEL, IN 46032
JGW287 [AS DESIGNED]
WESTVALE AT JACKSON GRANT 287
Fuel Type
Cef
Field Utilization
lothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
"M
Organization
TSI Energy Solutions
Matthew Timmons
Builder
HOMES BY McKENZIE, JNC
Electric
Timer Controls
704 kWh/Year
0.081kWh
$23.00
$0.58/Therm
2.874
0.33053
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
Inspection Status
Results are projected
C-M,
Energy Solutions