HomeMy WebLinkAboutASHMOOR 7 - AM007 (AS DESIGNED) (1)IECC 2009 Performance Compliance Property 3469 YANCEY PL CARMEL, IN 46074 AM007 (AS DESIGNED) ASHMOOR 7 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $2,105 $329 5467 $2,900 S1,080 s0 $3,980 Requirements C4405.3 Performance-based compliance passes by 4.5% 402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U -Factor 40322 Duct Testing Mandatory Checklist R405.2 Duct Insulation C-M, Energy Solutions As Designed $2,019 $284 $467 $2,769 $1,080 $0 $3,849 Design exceeds requirements for IECC 2449 Performance compliance by 4.5%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 12131/18 at 10:44 AM Ekotrope RATER - Version 3.1.0.2076 IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool. 3459 YANCEY PL CARMEL, IN 46074 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.32, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 385.0 CFM @ 25Pa Total Duct Leakage 595.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 12/31/18 at 10:44 AM Ekotrope RATER - Version 3.1.0.2076 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESIN ETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property 3459 YANCEY PL CARMEL, IN 46074 AM007 (AS DESIGNED) ASHMOOR 7 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 6,417 62,930 11,635 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identity any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT (2,117 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: OVER GARAGE (383 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I El Name: OVER AMBIENT (27 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall ] Name: CONDIAMB (Exterior Perimeter [ft]: 154, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 ]l Name: CONDIGAR (Exterior Perimeter [ft]: 57, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (2,639 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I 1 Energy Code Inspection Checklist Property organization 3459 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons AM007 (AS DESIGNED) Builder ASHMOOR 7 LENNAR HOMES El Name: CONDIAMB 2X6 (577 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIGAR (490 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIGAR 2X6 (80 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I El Name: CONDIATTIC (475 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (258 s.f.) R: 13.575 Name: CONDIGAR (57 s.f.) R: 10.876 Name: CONDIATTIC (106 s.f.) R: 13.575 Roof El Name: SECOND (2,527 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (24 s.f.) U: 0.182 Name: GARAG E (18 s.f.) U: 0.182 Inspection Status Results are projected C", Energy Solutions 2 Energy Code Inspection Checklist Property 3469 YANCEY PL CARMEL, IN 46074 AM007 (AS DESIGNED) ASHMOOR 7 Glazing Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected 11 Name: FRONT (199 s.f.), U:0.320, SHGC: 0.28, Orientation: WEST 11 Name: BACK (164 s.f.), U:0.320, SHGC: 0.31, Orientation: EAST E] Name: BACK 2X6 (110 s.f.), U:0.320, SHGC: 0.31, Orientation: EAST E] Name: BACK G❑ {18 s.f.), U:0.290, SHGC: 0.33, Orientation: EAST E] Name: BACK BSMT (16 s.f.), U:0.290, SHGC: 0.33, Orientation: EAST E] Name: LEFT (83 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH El Name: LEFT BSMT (16 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH El Name: RIGHT (42 s.f.), U:0.320, SHGC: 0.31, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution (1) • Natural Gas • 100°/ Heating Load @ 96.6 AFUE E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control C-M, Energy Solutions 3 Energy Code Inspection Checklist Property 3459 YANCEY PL CARMEL, IN 46074 Organization TSI Energy Solutions Matthew Timmons Inspection Status Results are projected AM007 (AS DESIGNED) Builder ASHMOOR 7 LENNAR HOMES ElTest Status: Blower -door tested House is air -sealed as to achieve 5,244 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 385.0 CFM @ 25 Pa. Total Duct Leakage is specified in Ekotrope at 595.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM251100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 J 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 J 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary C-M Energy Solutions Property Organization 3459 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons Inspection Status AM007 [AS DESIGNED] Builder Results are projected ASHMOOR 7 LENNAR HOMES General Building Information MM Number Of Bedrooms 5 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 6;417 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 62;936 Total Units in Building 1 Residence Type Single family detached Model MARKHAM (B) Community ASHMOOR 7 Climate Zone 5A Basement Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, Oft 1 8 154 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, Oft 1 8 57 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R -value Tap Bottom R-11 Draped, Oft 0 4 No 11.00 Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 211 Below Grade ❑ 0 2,117.0 sq. fL Exposed Exterior Conditioned Space Slab Library List Name Wall C Uninsulated Wood Frame / Other No ❑ 0 D 0.00 1 Building Summary Property Organization 3459 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons AM007 [AS DESIGNED] Builder ASHMOOR 7 LENNAR HOMES ramed Floor Name Library Type Ca OVER AMBIENT R-38, GRi OVER GARAGE R-38, GRi Framed Floor Library List ' Name R-valuf R-38, GRi 33.825 C-M,Eneergy Solutions Inspection Status Results are projected Floor Grade Surface Area Location 1.23 Above Grade 27.0 sq. tt Exposed Exterior 123 Above Grade 363.0 sq. R Unconditioned, attached garage Rim Joist Name Library Type Surface Area Location CONDIAMB G1 R-13, R-3.0 258.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-13, R-3.0 106.0 sq. ft. Attic CONDIGAR G1 R-13, OSB 57.0 sq. ft. Unconditioned, attached garage Rim Joist Library List Name R -value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 CONDIAMB G1 R-13 BATT, R-3.0 CONDIAMB 2X6 G1 R-19, R-3.0 2X6 n Medium 2,639.0 sq. fl. Exposed Exterior Medium 577.0 sq. fl. Exposed Exterior 2 Building Summary C-M Energy Solutions Property Organization 3459 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons Inspection Status AM007 [AS DESIGNED] Builder Results are projected ASHMOOR 7 LENNAR HOMES Name Library Type Surface Calor Surface Area Location CONDIATTIC G1 R-13 BATT, R-3.0 Medium 475.0 sq. ft. Attic CONDIGAR G1 R-13 Gar Walls Medium 490.0 sq. it Unconditioned, attached garage CONDIGAR 2X6 G1 R-19, 2x6 GAR Medium 80.0 sq. ft. Unconditioned, attached garage Wall Library List Name R -value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, 2x6 GAR 16.218 G1 R-19, R-3.0 2X6 20217 Glazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK 111-.32, SHGC-.31 CONDIAMB 0 0 0 East 164.0 sq. ft. BACK 2X6 111-.32, SHGG.31 CONDIAMB 2X6 0 0 0 East 110.0 sq. ft. BACK BSMT U-29, SHGG.33 CONDIAMB 0 0 0 East 16.0 sq. R BACK GD U-29, SHGG.33 CONDIAMB 0 0 ❑ East 18.0 sq. 1 FRONT 111-.32, SHGG28 CONDIAMB 0 0 ❑ West 1990.sq. ft. LEFT 111-.32, SHGG.31 CONDIAMB 0 0 ❑ North 83.0 sq. R LEFT BSMT 111-.32, SHGG.31 CONDIAMB 0 0 ❑ North 16.0 sq. R RIGHT 111-.32, SHGG.31 CONDIAMB 0 0 ❑ South 42.0 sq. R 3 Building Summary Property 3459 YANCEY PL CARMEL, IN 46074 AM007 [AS DESIGNED] ASHMOOR 7 lazing Library List Name U-.29, SHGC-.33 U-.32, SHGC-28 U-.32, SHGC-.31 Skylight Skylight Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected 0.33 0290 028 0.320 D.31 0.320 None Present None Present C-M, Energy Solutions Opaque Door Name Library Type Wall Assignment Basement Wall Assign ment Emittance Solar Surface Calor Surface Area Absorpta nce Location FRONT Steel Door C13NDIAMB 0.9 0.75 Medium 24.0 sq. ft Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 sq. fL Exposed Exterior Opaque Door Library List Name U -factor Steel Door 0.182 Roof Insulation I - Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location P.f.] Tiles SECOND R-38 Blown, GR1 2,527 No Medium 2.527.0 sq. ft Attic M Building Summary Property 3459 YANCEY PL CARMEL, IN 46074 AM007 [AS DESIGNED] ASHMOOR 7 oof Insulation Library List Name Has R-38 Blown, GR1 Whole House Infiltration Infiltration Mei Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 5 ACH at 50 Pa Blower -door tested Mechanical Ventilation None Present Inspection Status Results are projected 38268 4 C-M, Energy Solutions I Lighting % Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting 0 100 9 100 0 100 Onsite Generation IIIIIANNNWMM����� None Present Onsite Generation Library Solar Generation None Present None Present Building Summary C-M Energy Solutions Property Organization 3459 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons Inspection Status AM007 [AS DESIGNED] Builder Results are projected ASHMOOR 7 LENNAR HOMES olar Generation Library Conditioning Equipment Name Library Type Heating Percent Load Coaling Percent Lead Hot Water Percent Load Air conditioner (2) CA13NA060 0% 1OD% 0% Fuel4red air 9155A6010OS21 100% 0% 0% distribution (1) Water Heating (3) RE350" 0% 0% 100% Equipment Type: 915SA6010OS21 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 97 Use default EAE No EAE [kWh] 1;198 Equipment Type: CA13NA060 i Fuel Type Electric Distribution Type Forced Air Motor Type PSC (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 58.2 Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 Al Building Summary Property Organization 3459 YANCEY PL TSI Energy Solutions CARMEL, IN 46074 Matthew Timmons Sq. Feet Served Inspection Status AM007 [AS DESIGNED] Builder Results are projected ASHMOOR 7 LENNAR HOMES istribution System Distribution Type Forced Air Heating Equipment Fuel -f red air distribution [1) Cooling Equipment Air conditioner (2) Sq. Feet Served 6417 # Return Grilles 6 Supply Duct R Value 30 Return Duct R Value 30 Supply Duct Area [sq. ft.] 1299.4 Return Duct Area [sq. ft_] 1203.2 Duct Leakage to Outdoors (CFM25) 385 Total Leakage 595 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct t Duct Location Conditioned Space Percent Supply Area 70 Percent Return Area 70 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 30 Percent Return Area 30 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan ' Has Ceiling Fan No Cfm Per Watt 101 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 133 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 20 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 3459 YANCEY PL CARMEL, IN 46074 AM007 [AS DESIGNED] ASHMOOR 7 Organization TSI Energy Solutions Matthew Timmons Inspection Status Builder Results are projected LENNAR HOMES lothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption "M 704 kWh/Year 0.0nWh $23.00 $0.581Therm 2.874 0.331 Yes Standard 270 kWh Electric No No 709 kWh/Year C-M, Energy Solutions ,�