HomeMy WebLinkAboutASHMOOR 7 - AM007 (AS DESIGNED) (1)IECC 2009 Performance Compliance
Property
3469 YANCEY PL
CARMEL, IN 46074
AM007 (AS DESIGNED)
ASHMOOR 7
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$2,105
$329
5467
$2,900
S1,080
s0
$3,980
Requirements
C4405.3 Performance-based compliance passes by 4.5%
402.4.1.2 Air Leakage Testing
402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration U -Factor
40322 Duct Testing
Mandatory Checklist
R405.2 Duct Insulation
C-M,
Energy Solutions
As Designed
$2,019
$284
$467
$2,769
$1,080
$0
$3,849
Design exceeds requirements for IECC 2449 Performance compliance by 4.5%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
12131/18 at 10:44 AM
Ekotrope RATER - Version 3.1.0.2076
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
3459 YANCEY PL
CARMEL, IN 46074
LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-11
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.32, SHGC: 0.31
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 385.0 CFM @ 25Pa
Total Duct Leakage 595.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 12/31/18 at 10:44 AM
Ekotrope RATER - Version 3.1.0.2076
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
3459 YANCEY PL
CARMEL, IN 46074
AM007 (AS DESIGNED)
ASHMOOR 7
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
6,417
62,930
11,635
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identity any changes and ensure
that the home continues to meet the applicable energy code.
Slab
] Name: BSMT (2,117 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: OVER GARAGE (383 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
El Name: OVER AMBIENT (27 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
] Name: CONDIAMB (Exterior Perimeter [ft]: 154, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
]l Name: CONDIGAR (Exterior Perimeter [ft]: 57, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDIAMB (2,639 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
1
Energy Code Inspection Checklist
Property organization
3459 YANCEY PL TSI Energy Solutions
CARMEL, IN 46074 Matthew Timmons
AM007 (AS DESIGNED) Builder
ASHMOOR 7 LENNAR HOMES
El Name: CONDIAMB 2X6 (577 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (490 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIGAR 2X6 (80 s.f.)
R-0 continuous insulation, R-19 cavity insulation
Insulation Grade: I
El Name: CONDIATTIC (475 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Name: CONDIAMB (258 s.f.)
R: 13.575
Name: CONDIGAR (57 s.f.)
R: 10.876
Name: CONDIATTIC (106 s.f.)
R: 13.575
Roof
El Name: SECOND (2,527 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (24 s.f.)
U: 0.182
Name: GARAG E (18 s.f.)
U: 0.182
Inspection Status
Results are projected
C",
Energy Solutions
2
Energy Code Inspection Checklist
Property
3469 YANCEY PL
CARMEL, IN 46074
AM007 (AS DESIGNED)
ASHMOOR 7
Glazing
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
11 Name: FRONT (199 s.f.), U:0.320, SHGC: 0.28, Orientation: WEST
11 Name: BACK (164 s.f.), U:0.320, SHGC: 0.31, Orientation: EAST
E] Name: BACK 2X6 (110 s.f.), U:0.320, SHGC: 0.31, Orientation: EAST
E] Name: BACK G❑ {18 s.f.), U:0.290, SHGC: 0.33, Orientation: EAST
E] Name: BACK BSMT (16 s.f.), U:0.290, SHGC: 0.33, Orientation: EAST
E] Name: LEFT (83 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH
El Name: LEFT BSMT (16 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH
El Name: RIGHT (42 s.f.), U:0.320, SHGC: 0.31, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
0 Fuel -fired air distribution (1) • Natural Gas • 100°/ Heating Load @ 96.6 AFUE
E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
C-M,
Energy Solutions
3
Energy Code Inspection Checklist
Property
3459 YANCEY PL
CARMEL, IN 46074
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Results are projected
AM007 (AS DESIGNED) Builder
ASHMOOR 7 LENNAR HOMES
ElTest Status: Blower -door tested
House is air -sealed as to achieve 5,244 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 385.0 CFM @ 25 Pa.
Total Duct Leakage is specified in Ekotrope at 595.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM251100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 J 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 J 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
C-M
Energy Solutions
Property Organization
3459 YANCEY PL TSI Energy Solutions
CARMEL, IN 46074 Matthew Timmons
Inspection Status
AM007 [AS DESIGNED] Builder Results are projected
ASHMOOR 7 LENNAR HOMES
General Building Information
MM
Number Of Bedrooms 5
Number Of Floors 2
Conditioned Floor Area [sq. ft.] 6;417
Unconditioned, attached garage? Yes
Conditioned Volume [cu. ft.] 62;936
Total Units in Building 1
Residence Type Single family detached
Model MARKHAM (B)
Community ASHMOOR 7
Climate Zone 5A
Basement Wall
Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing
CONDIAMB R-11 Draped, Oft 1 8 154 Exposed Exterior Conditioned Space
CONDIGAR R-11 Draped, Oft 1 8 57 Exposed Exterior Conditioned Space
Basement Wall Library List
Name Feet From Wall Tap To Insulation Feet From Wall Top Tb Insulation Is Fully Insulated R -value
Tap Bottom
R-11 Draped, Oft 0 4 No 11.00
Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated 211 Below Grade ❑ 0 2,117.0 sq. fL Exposed Exterior Conditioned
Space
Slab Library List
Name Wall C
Uninsulated Wood Frame / Other No ❑ 0 D 0.00
1
Building Summary
Property Organization
3459 YANCEY PL TSI Energy Solutions
CARMEL, IN 46074 Matthew Timmons
AM007 [AS DESIGNED] Builder
ASHMOOR 7 LENNAR HOMES
ramed Floor
Name Library Type Ca
OVER AMBIENT R-38, GRi
OVER GARAGE R-38, GRi
Framed Floor Library List '
Name R-valuf
R-38, GRi 33.825
C-M,Eneergy Solutions
Inspection Status
Results are projected
Floor Grade Surface Area Location
1.23 Above Grade 27.0 sq. tt Exposed Exterior
123 Above Grade 363.0 sq. R Unconditioned, attached
garage
Rim Joist
Name
Library Type
Surface Area
Location
CONDIAMB
G1 R-13, R-3.0
258.0 sq. ft.
Exposed Exterior
CONDIATTIC
G1 R-13, R-3.0
106.0 sq. ft.
Attic
CONDIGAR
G1 R-13, OSB
57.0 sq. ft.
Unconditioned, attached garage
Rim Joist Library List
Name
R -value
G1 R-13, OSB
10.876
G1 R-13, R-3.0
13.575
CONDIAMB G1 R-13 BATT, R-3.0
CONDIAMB 2X6 G1 R-19, R-3.0 2X6
n
Medium 2,639.0 sq. fl. Exposed Exterior
Medium 577.0 sq. fl. Exposed Exterior
2
Building Summary
C-M
Energy Solutions
Property Organization
3459 YANCEY PL TSI Energy Solutions
CARMEL, IN 46074 Matthew Timmons
Inspection Status
AM007 [AS DESIGNED] Builder Results are projected
ASHMOOR 7 LENNAR HOMES
Name Library Type Surface Calor Surface Area Location
CONDIATTIC G1 R-13 BATT, R-3.0 Medium 475.0 sq. ft. Attic
CONDIGAR G1 R-13 Gar Walls Medium 490.0 sq. it Unconditioned, attached garage
CONDIGAR 2X6 G1 R-19, 2x6 GAR Medium 80.0 sq. ft. Unconditioned, attached garage
Wall Library List
Name R -value
G1 R-13 BATT, R-3.0 15.12
G1 R-13 Gar Walls 11.141
G1 R-19, 2x6 GAR 16.218
G1 R-19, R-3.0 2X6 20217
Glazing
Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area
Assignment Top Bottom
BACK 111-.32, SHGC-.31 CONDIAMB 0 0 0 East 164.0 sq. ft.
BACK 2X6 111-.32, SHGG.31 CONDIAMB 2X6 0 0 0 East 110.0 sq. ft.
BACK BSMT U-29, SHGG.33 CONDIAMB 0 0 0 East 16.0 sq. R
BACK GD U-29, SHGG.33 CONDIAMB 0 0 ❑ East 18.0 sq. 1
FRONT 111-.32, SHGG28 CONDIAMB 0 0 ❑ West 1990.sq. ft.
LEFT 111-.32, SHGG.31 CONDIAMB 0 0 ❑ North 83.0 sq. R
LEFT BSMT 111-.32, SHGG.31 CONDIAMB 0 0 ❑ North 16.0 sq. R
RIGHT 111-.32, SHGG.31 CONDIAMB 0 0 ❑ South 42.0 sq. R
3
Building Summary
Property
3459 YANCEY PL
CARMEL, IN 46074
AM007 [AS DESIGNED]
ASHMOOR 7
lazing Library List
Name
U-.29, SHGC-.33
U-.32, SHGC-28
U-.32, SHGC-.31
Skylight
Skylight Library List
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
0.33 0290
028 0.320
D.31 0.320
None Present
None Present
C-M,
Energy Solutions
Opaque Door
Name Library Type Wall Assignment
Basement Wall
Assign ment
Emittance
Solar Surface Calor Surface Area
Absorpta nce
Location
FRONT Steel Door C13NDIAMB
0.9
0.75
Medium 24.0 sq. ft
Exposed Exterior
GARAGE Steel Door CONDIGAR
0.9
0.75
Medium 18.0 sq. fL
Exposed Exterior
Opaque Door Library List
Name
U -factor
Steel Door
0.182
Roof Insulation I
-
Name Library Type Attic Exterior Area Clay or Concrete
Roof
Surface Color
Surface Area
Location
P.f.]
Tiles
SECOND R-38 Blown, GR1
2,527
No
Medium
2.527.0 sq. ft
Attic
M
Building Summary
Property
3459 YANCEY PL
CARMEL, IN 46074
AM007 [AS DESIGNED]
ASHMOOR 7
oof Insulation Library List
Name Has
R-38 Blown, GR1
Whole House Infiltration
Infiltration Mei
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
5 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
None Present
Inspection Status
Results are projected
38268
4
C-M,
Energy Solutions
I
Lighting
% Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting
Lighting Lighting Lighting
0 100 9 100 0 100
Onsite Generation IIIIIANNNWMM�����
None Present
Onsite Generation Library
Solar Generation
None Present
None Present
Building Summary
C-M
Energy Solutions
Property Organization
3459 YANCEY PL TSI Energy Solutions
CARMEL, IN 46074 Matthew Timmons
Inspection Status
AM007 [AS DESIGNED] Builder Results are projected
ASHMOOR 7 LENNAR HOMES
olar Generation Library
Conditioning Equipment
Name Library Type Heating Percent Load Coaling Percent Lead Hot Water Percent Load
Air conditioner (2) CA13NA060 0% 1OD% 0%
Fuel4red air 9155A6010OS21 100% 0% 0%
distribution (1)
Water Heating (3) RE350" 0% 0% 100%
Equipment Type: 915SA6010OS21
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
97
Use default EAE
No
EAE [kWh]
1;198
Equipment Type: CA13NA060
i
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
58.2
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
Al
Building Summary
Property
Organization
3459 YANCEY PL
TSI Energy Solutions
CARMEL, IN 46074
Matthew Timmons
Sq. Feet Served
Inspection Status
AM007 [AS DESIGNED]
Builder Results are projected
ASHMOOR 7
LENNAR HOMES
istribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -f red air distribution [1)
Cooling Equipment
Air conditioner (2)
Sq. Feet Served
6417
# Return Grilles
6
Supply Duct R Value
30
Return Duct R Value
30
Supply Duct Area [sq. ft.]
1299.4
Return Duct Area [sq. ft_]
1203.2
Duct Leakage to Outdoors (CFM25)
385
Total Leakage
595
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct t
Duct Location
Conditioned Space
Percent Supply Area
70
Percent Return Area
70
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
30
Percent Return Area
30
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Ceiling Fan
'
Has Ceiling Fan
No
Cfm Per Watt
101
Water Distribution
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
133
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
20
Drain Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
3459 YANCEY PL
CARMEL, IN 46074
AM007 [AS DESIGNED]
ASHMOOR 7
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
LENNAR HOMES
lothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
"M
704 kWh/Year
0.0nWh
$23.00
$0.581Therm
2.874
0.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
C-M,
Energy Solutions
,�