HomeMy WebLinkAboutA000.3\A1;14'-5{\H0.750000x;\S1#8;}"\A1;AT GATHERING
127127
DECK, PER SPEC
TOP OF FOUNDATIONTOP OF FLOOR
TOP OF PLATETOP OF FLOOR
TOP OF PLATE
6" FASCIA BOARD,\PPER SPECROOF SHINGLES,\PPER SPEC
HORIZONTAL SIDING, PER SPEC
SCALE:REAR ELEVATION1/8" = 1'-0"
124 6" TRIM, PER SPEC.4" TRIM, PER SPEC.
129 129
SCALE:LEFT ELEVATION1/8" = 1'-0"-
\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;8'-1{\H0.750000x;\S1#8;}"
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
TOP OF FOUNDATION
TOP OF PLATE
TOP OF PLATE
123.5 124
ROOF SHINGLES, PER SPEC.
6" FASCIA BOARD, PER SPEC.
6" CORNER BOARD, \PPER SPEC.
STONE VENEER, PER SPEC.
HORIZONTAL SIDING, PER SPEC.
129 129
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
ROOF SHINGLES, PER SPEC.
TOP OF PLATE
6" RAKE BOARD, PER SPEC.
TOP OF FLOORTOP OF PLATE
TOP OF FOUNDATIONTOP OF FLOOR
8" TRIM, PER SPEC.
\A1;8'-1{\H0.750000x;\S1#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
\A1;2'-2{\H0.750000x;\S7#8;}"
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;AT GARAGE\A1;7'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. AT GARAGE
6" RAKE BOARD, PER SPEC.
SIMILAR
FRIEZE, PER SPEC.
FRIEZE, PER SPEC.
6" TRIM, PER SPEC.
\A1;7'-7"
1212 1212
1212
1212
1212
1212 1212
FYPON #LV18x30 OR APPROVED EQUAL WITH \P4" TRIM SURROUND
12" SHUTTER, PER SPEC
STONE VENEER, PER SPEC.
SHAKE SIDING, PER SPEC.
6" TRIM, PER SPEC.\PROOF SHINGLES, PER SPEC.
6" CORNER BOARD, PER SPEC
1x TRIM, PER SPEC.STONE VENEER, PER SPEC.
12" SHUTTER, PER SPEC
ROOF SHINGLES, PER SPEC.
SHAKE SIDING, PER SPEC.
BOARD & BATTEN SIDING, PER SPEC
SCALE:FRONT ELEVATION1/4" = 1'-0"-
CL-07AD 2.3
\A1;1'-0"\PTYP.
\A1;8'-0"
4:12
7:127:12
9:12
9:12
3.5:12
\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
12:12
12:129:12
12:12
12:12 12:12
3.5:12
MIN. 114 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF
"A"1909ROOF AREA:SQ. FT.
\A1;19'-0"
\A1;8'-0"\A1;8'-0"
SCALE:ROOF PLAN1/8" = 1'-0"
"B"456ROOF AREA:SQ. FT.
12:12
12:1212:12
Cottage 2S
ATTIC VENT SCHEDULE
ROOF AREA "A"SQ FTG 1909 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
POT VENTS ONLY 2.55 3.18 3.39 49.39 8 0
AT EAVE 3.82 3.18 3.47 50.61 0 50.00
TOTAL (MIN)6.36 6.36 6.86 100.00
RIDGE
VENT 2.55 3.18 3.25 50.43 0 0 26.00
AT EAVE 3.82 3.18 3.19 49.57 0 46.00
TOTAL (MIN)6.36 6.36 6.44 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE{\C0;VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE\P** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS\P* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION}
ROOF AREA "B"SQ FTG 456 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
POT VENTS ONLY 0.61 0.76 0.85 52.59 2 0
AT EAVE 0.91 0.76 0.76 47.41 0 11.00
TOTAL (MIN)1.52 1.52 1.61 100.00
RIDGE
VENT 0.61 0.76 1.00 56.69 0 0 8.00
AT EAVE 0.91 0.76 0.76 43.31 0 11.00
TOTAL (MIN)1.52 1.52 1.76 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
1900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2018
Joel Hampshire11-14-2014
LEFT
WOODSIDE
2312.300.00.CPM
LOT 2
12-12-2018
PLOTTED: December 18, 2018 / Annie Lee / 2312-WOODSIDE-CZ-BASE-EL-CT2S.DWG
A3-CT2S
3SB.1Cottage 2S3 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule02/14/19
Mike Sheeks