Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S100.0
METAL HANGER BEARING WALL ABOVE (B.W.A.) AREA OF FLOOR SYSTEM DESIGNED FOR TILE BEAM / HEADER INTERIOR BEARING WALL INTERIOR BRACED WALL PANEL INDICATES POST ABOVE. PROVIDE SOLID\PBLOCKING UNDER POST OR JAMB ABOVE.*INDICATES HOLDOWN BELOW. LEGEND OR OSB SHEATHING REFER TO S-0 FOR TYPICAL STRUCTURAL NOTES & SCHEDULES\A1;50'-0" OVERALL\A1;19'-1{\H0.75x;\S1#2;}"\A1;19'-1{\H0.75x;\S1#2;}"\A1;11'-9" \A1;64'-10" OVERALL \A1;2'-0" \A1;4'-0" \A1;36'-0" \A1;8'-0" \A1;6'-11" \A1;32'-8" \A1;64'-10" OVERALL \A1;14'-6{\H0.75x;\S1#2;}"\A1;4'-9{\H0.75x;\S1#2;}" \A1;1'-9{\H0.75x;\S1#2;}" \A1;9'-10" \A1;20'-6{\H0.75x;\S1#2;}" \A1;29'-1" \A1;32'-2" \A1;8'-3" \A1;1'-10{\H0.75x;\S1#2;}" \A1;16'-3" \A1;2'-1" \A1;3'-8{\H0.75x;\S1#2;}" \A1;11'-0{\H0.75x;\S1#2;}"\A1;7'-4{\H0.75x;\S1#2;}" \A1;1'-0"\A1;1'-0" \A1;1'-2"\A1;1'-2"\A1;1'-2"\A1;1'-2" \A1;1'-8" \A1;1'-8" \A1;14'-10" \A1;50'-0" OVERALL\A1;20'-0"\A1;18'-8{\H0.75x;\S1#2;}"\A1;11'-3{\H0.75x;\S1#2;}" W8x10 STEEL BEAM DROPPED, CONT. *POST ABOVE W8x10 DROPPED, CONT.W8x10 DROPPED, CONT. \A1;\pxql;{\LCLEARSPAN OPTION:\P}W8x31 DROPPED\P(OMIT THIS COLUMN AND FOOTING)\A1;\pxql;SPLICE STEEL BEAM HERE IF REQ'D ** POST ABOVE POST ABOVEPOST ABOVE * \A1;11 {\H0.7x;\S7#8;}" I-JOISTS -SERIES & SPACING PER MANUF.- (CANT'D) \A1;11 {\H0.7x;\S7#8;}" I-JOISTS -SERIES & SPACING PER MANUF.- FNDN. STEP DETAIL 19/SD.02 SD.013A SD.014 SD.01 1SD.01 14SD.02 SD.015 SD.011 SD.0216 SD.011 SD.011 SD.011 \A1;\pxql;BEAM POCKET (TYP.)\A1;3'-0{\H0.75x;\S1#4;}" \A1;3'-10{\H0.75x;\S1#2;}" \A1;16'-9{\H0.75x;\S3#4;}" \A1;10'-6"\A1;11'-6{\H0.75x;\S1#4;}"\A1;8'-6"\A1;9'-5{\H0.75x;\S3#4;}"\A1;10'-0" \A1;14'-4{\H0.75x;\S3#4;}" \A1;4'-2{\H0.75x;\S1#4;}" \A1;\pxql;OFFSET BEARING WALL ABV.\A1;\pxql;(750 PLF) \A1;9'-11"\A1;9'-0"\A1;9'-5"\A1;9'-11" \A1;{\LPORCH SLAB\P\pxqc;}-SEE NOTES ON S-0 \A1;\pxqc;{\LBASEMENT SLAB\P}-SEE NOTES ON S-0 \A1;11 {\H0.7x;\S7#8;}" I-JOISTS -SERIES & SPACING PER MANUF.- \A1;\pxql;{\LCLEARSPAN OPTION:\P}W8x24 DROPPED (OMIT THIS COLUMN AND FOOTING) \A1;PC2\P(6.5k) \A1;PC2 (6.0k) OR\PPC4 (13.0k) @ OPT. CLEARSPAN \A1;PC1\P(5.5k) \A1;PC3\P(9.0k) \A1;PC4\P(12.5k) *POST ABOVE POURED CONC. WALL STANDARD. SEE REFERENCED DETAILS FOR WALL & FOOTING SPEC'S. (TYP.) *POST ABOVE *POST ABOVE*POST ABOVE* *POST ABOVE *POST ABOVE *POST ABOVE*POST ABOVE *POST ABOVE W8x10 STEEL BEAM DROPPED, CONT. OFFSET BEARING\PWALL ABOVE \A1;PC3\P(8.65k) \A1;PC1\P(4.5k)\A1;PC3\P(9.2k) \A1;PC1\P(4.15k) W8x10 STEEL BEAM DROPPED, CONT.END F.J.END F.J. \A1;11 {\H0.7x;\S7#8;}" I-JOISTS -SERIES & SPACING PER MANUF.- W8x10 STEEL BEAM DROPPED, CONT. W8x10 STEEL BEAM DROPPED, CONT. \A1;2'-0" \A1;4'-0" \A1;11'-7{\H0.75x;\S1#2;}" \A1;21'-0{\H0.75x;\S1#2;}" \A1;\pxql;{\LNOTE:} OMIT THIS SECTION OF BEAM W/ INSTALLATION OF OPT. 2x4 @16" O.C. BRG. WALL ON 8"x16" THICKENED SLAB. FNDN. STEP DETAIL 19/SD.02SD.015 9SD.01 *POST ABOVE SD.017 SD.029 \A1;\pxqc;{\LGARAGE SLAB\P}-SEE NOTES ON S-0 SD.017 POST ABOVE \A1;PC3\P(9.0k)\A1;PC1\P(4.5k)1st Floor Framing PlanS-1.01ST FLOOR FRAMING PLAN1SCALE: 1/8"=1'-0"copyright : MULHERN & KULPStructural Engineering, Inc.cissue date: drawn by: project mgr: M&K project number: initial: REVISIONS: date: 12-17-18 JGF ANK 125-14017 Woodside ModelCopper Run - Lot 2Midwest Zonesheet:1900 East Golf Road, Suite 300Schaumburg, Illinois 60173Pulte Midwest Zone02/14/19 Mike Sheeks