HomeMy WebLinkAboutsewer10701 N. C
Residential
�
Permit Type
Project WO
Avenue Suite A Indianapolis, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.trico.eco
SANITARY SEWER PERMIT 999913150
Final Subdivision Sanctuary at 116th St
ENG4312007 Section Number
Project Name Sanctuary at 116th Street Section 1, 2A, 3, 4A Lot Number
Project Developer Platinum Properties Address Number
Lift Station
Treatment Plant
Parcel Acreage
EDU in Gallons
16 Zionsville Presbyterian Station Address 2
Local Sewer Charge - District Contribution
Plan Review and Inspection
Application Fee
EDU Fee
Interceptor Fee
Other Fees
Fees Due
Invoice Number
CTRWD WWTP Street
0.23 City
310
Zip Code
County
0.00
guilder
0.00
150.00
Phone Number
1908.00
Owner
0.00
phone Number
0.00
2058.00
Occupant
Phone Number
82
11884
West Road
Zionsville
46077
Hamilton
Ryan Homes
317-371-6577
PLEASE NOTE: Installation of building sewer shall be per the specifications of the TriCo Regional Sewer Utility (see
reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench"
phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other
sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no
liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are
extended beneath driveways or sidewalks. The. permit h1cider (property owner, developer or builder) will be
responsible for damages to TriCo's sewer system. This innudes damages to manholes, castings, manhole lids and
the like; caused by construction activity on tiie building is the subject of this permit.
Inspections by TriCo are MANDATORY and shall be arran,-,,,:4 :, '-;;-acting TriCo's office at 844-9200 24 hours in
advance. All new construction will be placed on billir:g 7vjr.. _ . ,r connection has been made or when water is
connected, whichever comes first.
The building has: y rb�ai:�';�.""""'"
i SNT846SNT847
Grease Trap Slab Foundation
Grease Interceptor Crawl SpacelU4un tr,le MS USMH SNT-846 SNT-847 DSM
H
Grit Interceptor Basement YES Lid Elevation 906.96 907.35
Grinder Station
First Floor Elevation 911.18 911.18
Water Service City of Carmel Basement Elevation 902.32 902.32
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor
_4.22 3.83 Ft.
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only
TTriCo currently requires that an I&I inspection is performed and a Certificate of Compliance is issued prior to occupancy 1
sale of a properrty. Please review attached III Permit.
t7 T Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure.
The terms of the conditional permit, if any, are listed below.
Plans have been submitted.
All fees have been paid.
No certificate of insurance required.
No additional permits required.
No manhole core permit required.
The facility is not classified a. a FOG facility.
(Notes)
By signing below, I attest that I am familiar with the District's specifications and agree to accept respon
Builder/ Owner Signature �1�.�r Phon
Printed Name
M
ApproveS�-&rh1-W,W-
Permit
Z� joj o
RVen Distract Engineer is valid for ONE-YEAR from the date issued. Permit valid only with'
�010NAL Sal.
all work done undL,
ber 317 — 2>4 l�
Tr C
HAMIL
s permit.
7xrz
h
U
2019