Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EC
Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Property/Builder Information Building Name IND SY 0077 Owner's Name NVR, Inc. Property Address 11992 WEST ROAD City, St, Zip ZIONSVILLE, IN 46077 Phone Number Builder's Name NVR, Inc. Phone Number 703-956-4231 Email Address bheuwie@nvrinc.com Plan/Model Name Springmanor SPM00-01 Community/Development SANCTUARY PRESERVE Permit Date/Number Organization Information Organization Name PEG Address 3975 Fair Ridge Drive,Ste T15S City, St, Zip Fairfax, VA 22033 Phone Number 703-934-2777 Website www.pegenv.com Rating/RESNET Information Provider ID 1998-109 Sample Set ID 0000 Registry ID Registry Date Registered Rater's Name Nick Barry Rater's ID 4211992 Rater's Email nbarry@pegenv.com Last Field Insp Rating Type Projected Rating Reason for Rating New Home Rating Number IND SY 0077 Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 2 of 13 General Building Information Area of Conditioned. Space(sq ft) 4512 Volume of Conditioned. Space 42864 Year Built 2019 Housing Type Single-family detached Level Type(Apartments Only) None Floors on or Above-Grade 1 Number of Bedrooms 3 Foundation Type Conditioned basement Enclosed Crawl Space Type N/A Number of Stories Including Conditioned Basement 2 Thermal Boundary Location REM Default Foundation Wall Information Name Library Entry Location Length(ft) Total Height(ft) Depth Below Grade(ft) Height Above Grade(ft) Uo Value Combo* Uo Value (wall only) Ambient R-13 Finished GI Cond->ambient/grn 205.0 8.0 6.0 2.0 0.067 0.097 Garage R-11 Draped 4' GI 8" Cond->garage/grnd 31.0 8.0 6.0 2.0 0.089 0.796 * Uo Value Combo combines wall, airfilm, and soil path Foundation Wall Library List Foundation Wall: R-13 Finished GI Type Solid concrete or stone Thickness(in) 3.5 Studs Wood, 2x4, 16" o.c. Interior Insulation Continuous R-Value 0.0 Frame Cavity R-Value 13.0 Cavity Insulation Grade 1 Ins top 0.0 ft from top of wall Ins Bottom 0.0 ft from bottom of wall Exterior Insulation R-Value 0.0 Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 3 of 13 Foundation Wall Library List Ins top 0.0 ft from top of wall Ins bottom 0.0 ft below grade Note Foundation Wall: R-11 Draped 4' GI 8" Type Solid concrete or stone Thickness(in) 8.0 Studs None Interior Insulation Continuous R-Value 11.0 Frame Cavity R-Value 0.0 Cavity Insulation Grade 1 Ins top 0.0 ft from top of wall Ins Bottom 4.0 ft from top of wall Exterior Insulation R-Value 0.0 Ins top 0.0 ft from top of wall Ins bottom 0.0 ft below grade Note Slab Floor Information Name Library Entry Area(sq ft) Depth Below Grade(ft) Full Perimeter(ft) Exposed Perimeter(ft) On-Grade Perimeter(ft) Uninsulated Finished 2256 6.0 236 236 0 Slab Floor Library List Slab Floor: Uninsulated Finished Slab Covering Carpet Perimeter Insulation (R-Value) 0.0 Perimeter Insulation Depth (ft) 0.0 Under-Slab Insulation (R-Value) 0.0 Under-Slab Insulation Width (ft) 0.0 Slab Insulation Grade 1 Radiant Slab No Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 4 of 13 Slab Floor Library List Note Rim and Band Joist Information Name Location Area(sq ft) Continuous Ins Framed Cavity Ins Cavity Ins Thk(in) Joist Spacing Insulation Grade Uo Value Ambient Cond -> ambient 205.00 0.0 13.0 5.5 16.0 1 0.064 Garage Cond -> garage 31.00 0.0 13.0 5.5 16.0 1 0.064 Above-Grade Wall Name Library Entry Location Exterior Color Area(sq ft) Uo Value Ambient R-13 GI Cond -> ambient Medium 2050.00 0.082 Garage R-13 GI Cond -> garage Medium 310.00 0.082 Above-Grade Wall Library List Above-Grade Wall: R-13 GI Information From Quick Fill Screen Wall Construction Type Standard Wood Frame Continuous Insulation (R-Value) 0.0 Frame Cavity Insulation (R-Value) 13.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (defined) 0.1900 Gypsum Thickness (in) 0.5 Note Window Information Overhang Interior Adjacent Name Wall Assignment Orient U-Value SHGC Area (sqft) Depth (ft) To Top (ft) To Btm (ft) Winter Shading Summer Shading Winter Shading Summer Shading Front AGWall 1 Northwes 0.300 0.200 62.00 0.0 0.0 0.0 0.85 0.70 None None Front AGWall 1 Northwes 0.340 0.300 42.00 0.0 0.0 0.0 0.85 0.70 None None Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 5 of 13 Window Information Overhang Interior Adjacent Name Wall Assignment Orient U-Value SHGC Area (sqft) Depth (ft) To Top (ft) To Btm (ft) Winter Shading Summer Shading Winter Shading Summer Shading Right AGWall 1 Southwes 0.300 0.200 15.00 0.0 0.0 0.0 0.85 0.70 None None Rear AGWall 1 Southeast 0.300 0.200 102.00 0.0 0.0 0.0 0.85 0.70 None None Left AGWall 1 Northeast 0.300 0.200 45.00 0.0 0.0 0.0 0.85 0.70 None None Door Information Name Library Entry Wall Assignment Opaque Area(sq ft) Uo Value R-Value of Opaque Area Storm Door Front Door Masonite AGWall 1 21.0 0.155 5.5 No Garage Door R-7 Steel AGWall 2 21.0 0.126 7.0 No Roof Information Name Library Entry Ceiling Area(sq ft) Roof Area(sq ft) Exterior Color Radiant Barrier Type Uo Value Cement or Clay Tiles Roof Tile Ventilation Attic R-38 Blown Attic GI 2251.00 2613.00 Medium No Attic 0.026 No No Attic Hatch R-38 Batt Attic GI 5.00 6.00 Medium No Attic 0.041 No No Roof Library List Ceiling: R-38 Blown Attic GI Information From Quick Fill Screen Continous Insulation (R-Value) 25.0 Cavity Insulation (R-Value) 13.0 Cavity Insulation Thickness (in) 10.0 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (defined) 0.0700 Ceiling Type Attic Note Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 6 of 13 Roof Library List Ceiling: R-38 Batt Attic GI Information From Quick Fill Screen Continous Insulation (R-Value) 0.0 Cavity Insulation (R-Value) 38.0 Cavity Insulation Thickness (in) 12.0 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1100 Ceiling Type Attic Note Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 7 of 13 Mechanical Equipment Number of Mechanical Systems 3 Heating SetPoint(F) 68.00 Heating Setback Thermostat Present Cooling SetPoint(F) 78.00 Cooling Setup Thermostat Present Heat: 92.1AFUE GasFurn 60k SystemType Fuel-fired air distribution Fuel Type Natural gas Rated Output Capacity (kBtuh) 55.0 Seasonal Equipment Efficiency 92.1 AFUE Auxiliary Electric 573 Eae Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 Cool: 13SEER A/C 3 ton System Type Air conditioner Fuel Type Electric Rated Output Capacity (kBtuh) 36.0 Seasonal Equipment Efficiency 13.0 SEER Sensible Heat Fraction (SHF) 0.70 Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 DHW: 50 gal. 0.95EF Elec Water Heater Type Conventional Fuel Type Electric Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 8 of 13 Mechanical Equipment Energy Factor 0.95 Recovery Efficiency 0.98 Water Tank Size (gallons) 50 Extra Tank Insulation (R-Value) 0.0 Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 DHW Efficiencies All bath faucets & showers <= 2gpm false All DHW pipes fully insulated >= R-3 false Recirculation type None (standard system) Farthest fixture to DHW heater 75 TOTAL Pipelength for longest DHW run 95 DWHR unit present? false DHW Diagnostics dhwGpd 46.92 peRatio 0.83 dishwasherGpd 2.13 clothesWasherHotWaterGPD 3.89 EDeff 0.97 ewaste 27.83 tmains 57.90 dwhrWhInletTempAdj 0.00 pumpConsKwh 0.00 pumpConsMmbtu 0.00 Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 9 of 13 Duct Systems Name Conditioned Floor Area(sq ft) 4512.0 # of Returns 4 Heating System 92.1AFUE GasFurn 60k Cooling System 13SEER A/C 3 ton Supply Duct Surface Area(sq ft) 913.7 Return Duct Surface Area(sq ft) 676.8 Duct Leakage Qualitative Assessment Not Applicable Duct Leakage to Outside Supply+Return 0.035 CFM25 / CFA Supply Only Not Applicable Return Only Not Applicable Total Duct Leakage 0.070 CFM25 / CFA Duct Tightness Test Postconstruction Test Type Location Percent Location R-Value Supply Conditioned space 95.0 0.0 Attic, exposed 5.0 8.0 Return Conditioned space 95.0 0.0 Attic, exposed 5.0 8.0 Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 10 of 13 Infiltration and Mechanical Ventilation Whole House Infiltration Measurement Type Blower door test Heating Season Infiltration Value 3.50 ACH @ 50 Pascals Cooling Season Infiltration Value 3.50 ACH @ 50 Pascals Shelter Class 4 Code Verification Tested Mechanical Ventilation for IAQ Type Exhaust Only Rate(cfm) 110 Sensible Recovery Efficiency(%) 0.00 Total Recovery Efficiency(%) 0.00 Hours per Day 20.7 Fan Power (watts) 36.00 ECM Fan Motor false Ventilation Strategy for Cooling Cooling Season Ventilation Natural Ventilation Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 11 of 13 Lights and Appliances Rating/RESNET audit Ceiling Fan CFM / Watt 0.00 Refrigerator kWh/yr 703 Refrigerator Location Conditioned Range/Oven Fuel Type Natural gas Induction Range No Convection Oven No Dishwasher Energy Factor 0.78 Dishwasher kWh/yr 270 Place Setting Capacity 12 Clothes Dryer Fuel Type Electric Location Conditioned Moisture Sensing No CEF 2.62 Clothes Washer Location Conditioned LER (kWh/yr) 704 IMEF 0.331 Capacity (CU.Ft) 2.874 Electricity Rate 0.08 Gas Rate 0.58 Annual Gas Cost 23.00 Qualifying Light Fixtures Interior CFLs % 90.0 Interior Fluorescent % 0.0 Exterior Lights % 0.0 Garage Lights % 0.0 Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 12 of 13 Mandatory Requirements IECC Requirements Verified IECC 04 true Verified IECC 06 true Verified IECC 09 true Verified IECC 12 true Verified IECC 15 true Verified NY-ECCC 2016 true Verified IECC MI false EPA Requirements Rater certifies that the home complies with the following requirements for: None Rater Design Review Checklist(National) Rater Field Checklist(National) HVAC Design Report HVAC Commissioning Checklist (optional) ENERGY STAR Version 3 Appliances Amount Refrigerators 1 Ceiling Fans 0 Exhaust Fans 0 Dishwashers 1 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grad: true Basement Floor Area 2256.00 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist false EPA Field App ID Building Summary Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 Page 13 of 13 DOE Zero Energy Ready Home Home Builder ID Number Mandatory Requirements Verified Fenestration false Verified Insulation false Verified Duct Location false Verified Appliance false Verified Lighting false Verified Fan Efficiency false Verified Water Efficiency false Verified EPA Indoor airPLUS false Verified Renewable Energy Ready Solar Electric false Optional Home Builder Commitments for Recognition Certified under the EPA WaterSense for New Homes Program No Certified under the IBHS fortified for Safer Living Program No Followed the DOE Zero Energy Ready Home Quality Management Guidelines No The buyer of this home signed a waiver giving DOE Zero Energy Ready Home access to utility bill data for one year. No Active Solar System Type None Collector Loop Type None Collector Type None Collector Orientation None Area(sq ft) 0.0 Tilt(degrees) 0.0 Volume(cu ft/gal) 0.0 2009 IECC Energy Cost Compliance Property NVR, Inc. 11992 WEST ROAD ZIONSVILLE, IN 46077 Weather:Indianapolis, IN IND SY 0077 IND SY 0077.blg Organization PEG 703-934-2777 Nick Barry Builder NVR, Inc. HERS Projected Rating Rating No:IND SY 0077 Rater ID:4211992 REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Annual Energy Cost $/yr 2009 IECC As Designed Heating 1368 1266 Cooling 263 211 Water Heating 404 404 SubTotal - Used to Determine Compliance 2034 1880 Lights & Appliances 1063 1060 Photovoltaics -0 -0 Service Charge 120 120 Total 3217 3060 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.2)PASSES Duct Leakage (Section 403.2.2)PASSES Mandatory Requirements Check Box (2009 IECC)PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 7.6%. Name Nick Barry Signature Organization PEG Date 15 January 2019 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. Home Energy Rating CertificateHERS Index: 67REM/Rate - Residential Energy Analysis and Rating Software v15.4.2This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado.The Home Energy Rating Standard Disclosure for this home is available from the rating provider.Projected Rating: Based on Plans - Field Confirmation Required.General InformationConditioned Area 4512 sq. ft. House Type Single-family detachedMechanical Systems FeaturesHeating: Fuel-fired air distribution, Natural gas, 92.1 AFUE.Building Shell FeaturesCeiling Flat R-38.0 Slab R-0.0 Edge, R-0.0 UnderLights and Appliance FeaturesPercent Interior Lighting 90.00 Range/Oven Fuel Natural gas TITLEEstimated Annual Energy CostUse MMBtu Cost PercentHeating 88.7 $1151 42%Conditioned Volume 42864 cubic ft. Foundation Conditioned basementCooling: Air conditioner, Electric, 13.0 SEER.Sealed Attic NA Exposed Floor NAPercent Garage Lighting 0.00 Clothes Dryer Fuel ElectricCompanyCooling 3.3 $106 4%Bedrooms 3Water Heating: Conventional, Electric, 0.95 EF, 50.0 Gal.Vaulted Ceiling NA Window Type U-Value: 0.300, SHGC: 0.200Refrigerator (kWh/yr) 703 Clothes Dryer CEF 2.62AddressHot Water 9.9 $318 12%Duct Leakage to Outside 157.92 CFM25.Above Grade Walls R-13.0 Infiltration Rate Htg: 3.50 Clg: 3.50 ACH50Dishwasher (kWh/yr) 270 Ceiling Fan (cfm/Watt) 0.00City, State, ZipLights/Appliances 34.8 $1060 38%Ventilation System Exhaust Only: 110 cfm, 36.0 watts.Foundation Walls R-13.0 Method Blower door testPhone #Photovoltaics -0.0 $-0 -0%Programmable Thermostat Heat=Yes; Cool=YesFax #Service Charges $120 4% Total 136.6 $2756 100%Property HERSNVR, Inc. Rating Type: Projected Rating Certified Energy Rater: Nick Barry11992 WEST ROAD Rating Date: Rating Number: IND SY 0077ZIONSVILLE, IN 46077 Registry ID:CriteriaThis home meets or exceeds the minimum criteria for the following: