Loading...
HomeMy WebLinkAbout2363 M1-01 Bulletin 2HVAC DEMOLITION PLAN SCALE: 1/4" = 1'-0' RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City OF Camel DATE: 03/07/19 MECHANICAL SYMBOLS TURNING VANES VOLUI-IE DAMPER SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT TRM51TION IN DUCT DIMENSION TRANSITION (RECTANGULAR DUCT TO ROUND DUCT) e" INDICATE5 51ZE OF ROUND DUCTWORK (DIAMETER) 11 y TRANSITION IN DUCT DIMENSION ® 5A DIFFUSER EXHAUST OR RETURN AIR RE615TER — — — — — — — — — — — DUCTWORK AND/OR EQUIPMENT TO BE REMOVED THERMOSTAT c:::= MECHANICAL ABBREVIATIONS AF AIR FOIL GFM GUBIG FEET PER MINUTE deg. F DEGREES FAHRENHEIT EAT ENTERING AIR TEMPERATURE EDB ENTERIN6 DRY BULB TEMPERATURE JEER ENERGY EFFICIENCY RATIO ESP EXTERNAL STATIC PRESSURE ETR EXI5TIN5 TO REMAIN EHB ENTERIN6 PET BULB TEMPERATURE HCFC HYDROGHLOROFLIUORGCARBON HP HORSEPOWER LAT LEAVING AIR TEMPERATURE LB5 POUNDS LDB LEAVING DRY BULB TEMPERATURE LHB LEAVING HET BULB TEMPERATURE MBH THOUSAND BRITI5H THERMAL UNITS (BTU) MCA MINIMUM CIRCUIT AMPAGITY MOCP MAXIMUM OVERCURRENT PROTECTION MOD MODULATING MUA MAKEUP AIR UNIT NAT. 61 NATURAL 671 OA 01 AIR PH PHASE RA RETURN AIR RPM REVOLUTIONS PER MINUTE 5H51 51N&LE WIDTH 51N&LE INLET TYP TYPICAL V VOLTS GENERAL NOTES A. CONDUCT FIELD SURVEY OF EXISTING CONDITIONS PRIOR TO SUBMISSION OF BID AND START OF HORK. NO ADDITIONAL PAYMENTS HILL BE MADE ON CLAIMS THAT ARISE FROM LACK OF KNOHLED6E OF EXISTING CONDITIONS. B. SCHEDULE UTILITY SERVICE SHUTDOWNS REQUIRED FOR NEW CONSTRUCTION WITH OWNER AND GENERAL TRADES PRIOR TO SHUTTING DOWN SYSTEMS. GIVE ONE REEK ADVANCE NOTICE. C. COORDINATE SCHEDULE OF HOW REQUIRED IN OCCUPIED AND OPERATING AREAS WITH OHNER PRIOR TO STARTING SUCH WORK. D. ALL HOW TO BE COMPLETED IN ACCORDANCE WITH THE LOCAL BUILDING CODE AND AUTHORITY HAVING JURISDICTION. E. MECHANICAL HVAG HORK SHALL BE COMPLETED BY AN INDIVIDUAL OR BUSINESS THAT 15 LICENSED BY THE STATE CONSTRUCTION INDUSTRY LICENSING BOARD. O PLAN NOTES I. EXISTIN6 THERMOSTAT TO REMAIN. 2. EXISTIN6 EXHAUST 61 AND FAN TO REMAIN. 3. EXISTING SUPPLY DIFFUSER TO REMAIN. GLEAN DIFFUSER. CONTRACTOR SHALL REPLACE DIFFUSER WITH SAME TYPE/NECK 51ZE IF DIFFUSER 15 DAMAGED. 4. REMOVE SUPPLY GRILLE. PREPARE DUCT FOR NEW SUPPLY GRILLE. 5. REMOVE AND RELOCATE SUPPLY GRILLE. GLEAN DIFFUSER. 6. REMOVE SUPPLY GRILLE AND GAP SUPPLY DUCT AT MAIN. 7. EXISTING 3 TON FURNACE 5ERVIN6 SUBWAY AREA 4 BAGKROOM ABOVE CEILING. EXISTING CONDENSING UNIT ON ROOF, ALLEGIANCE 10 MODEL NUMBER TA0036AIOOAO, SERIAL NUMBER K1421F2CF, 205 VOLT, I PHASE, 22 AMPS, 30 MOCP. HGFG-22, MANUFACTURED 01 8. EXI5TIN6 5 TON FURNACE SERVING, MERGHANDI51N6 AREA ABOVE GEILIN6. EXI5TIN6 GONDEN51N6 UNIT ON ROOF, ALLEOIANGE IO MODEL NUMBER TA0060AIOOAO, SERIAL NUMBER 1212517g3, 208 VOLT, I PHASE, 3-1 AMPS, 60 MOOR HCFC-22, MANUFACTURED 05/c14. �inc. M 334a51 Culls BIW.,216 Eastlake, ON II095 s Ban 953.87M if Ban 953.1 ID9 ,eC,ncl.cam dea Cnd IcoWmbm M m CM N L S 0> m Na rt+ ¢ fRm m 3o0 -O�n mo m Uro NZ � �LV L- 02 VZ= ) c �Ox) imE E USE �U) U. w I . i0> Z0 0 o U dUaU d U U22 80 = a� tU rCID�m � 3> 00 00 bU D.\kV G. 'Do 0p� No.. 11700214ix A' STATE OF .� DIAN ANAL ao m ro F Q o N 0 N 0 N U N ill n 0 O � 0 N H o Of W U a O _ N 0 0 ? ? LL r r W � J J J J N m m a� z z c4 z o N J LU LU J UO �OoCQ� z Q > LU �1WU20 0 DRi Eci`lDBf LAJ JDM $ME 1141 = 1'-011 ISSUE DATE JOB NUMBER 18-603 cMNONUMBER M1=01