ELECTRICAL DEMOLITION PLAN
SCALE: 1/4" = 1'-0'
WOMEN
ELECTRICAL SYMBOLS
�A BRANCH CIRCUIT HOMERUN TO PANEL "A", CIRCUIT #3 AND #5.
/ 39 PROVIDE THE PROPER QUANTITY OF 12 AW6 CONDUCTORS PLUS
1-12 AY46 6ND FOR THE CIRGUIT(S) INDICATED.
W DUPLEX RECEPTACLE - MOUNTING AT Ib' A.F.F. OR A5 NOTED
V DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER
O\ TWO 12OV, 20A DUPLEX RECEPTACLES MOUNTED IN A 2-6AN6
\ BOX AT lb" A.F.F. OR AS NOTED
\
\ 36"
\ W 120V, 20A DUPLEX RECEPTACLE -MOUNTING AT 36" A.F.F.
\ 12OV, 20A DUPLEX RECEPTACLE WITH USB GHAR61N6 PORT -
/' \\QD MOUNT AT b" BELOW WINDOW SILL AND COORDINATE FINAL
/ 4 \ LOCATION WITH GA5EWORK INSTALLATION PRIOR TO ROU6H-IN
1 / \
SPECIAL PURPOSEOUTLET. VERIFY GONFI6URATION WITH
EQUIPMENT PROVIDED.
- 4 \ 0 POWER POLE
r--1
a
L-J I
SUBWAY SEATING
\
\
4 r / j \ 301 UNFUSED DISCONNECT SWITCH, 30 AMPERE, 3 POLE OR AS
\ NOTED
4 v v
ONELINE REPRESENTATION OF A MOLDED CASE CIRCUIT
BREAKER, 51ZE AS NOTED
PANELBOARD - O TO 150 VOLTS TO GROUND
PLAN NOTE TAG, REFER TO PLAN FOR DESCRIPTION
/ A.F.F. ABOVE FINISHED FLOOR
\ MGB MAIN CIRCUIT BREAKER
/ MLO MAIN LU35 ONLY
/ WP WP L-EATHERPROOF
HEAVY LINE PEI&HT INDICATES THIS EQUIPMENT 15 NEW UNLESS
NOTED OTHERWISE
LIGHT LINE WE16HT INDICATES THI5 EQUIPMENT IS EXISTING
UNLE55 NOTED OTHERWISE
HEAVY DASHED LINE VEI&HT INDICATES THI5 EQUIPMENT 15 TO
BE REMOVED UNLESS NOTED OTHEPH15E
O PLAN NOTES
I. EXCEPT WHERE 5PEGIFIGALLY INDICATED OTHERWISE, NO WORK
IN THI5 AREA. MAINTAIN ALL EXISTING LUMINAIRES, CONTROLS,
DEVICES, AND ASSOCIATED BRANCH GIRGUIT WIRIN6.
2. EXI5TIN6 WALK-IN COOLER TO REMAIN. MAINTAIN ALL EXI5TIN5
ASSOCIATED DEVICES AND BRANCH GIRGUIT WIRING.
3. MAINTAIN EXISTING LUMINAIRE, A550GIATED CONTROLS, AND
BRANCH GIRGUIT WIRING.
4. REMOVE EXISTING LUMINAIRE, ASSOCIATED CONTROLS, AND
BRANCH GIRGUIT WIRING.
5. EXI5TIN6 LUMINAIRE TO BE REMOVED AND RELOCATED TO NEW
LOCATION INDIGATED ON DRAWING EI-02. REUSE AND EXTEND
EXI5TIN6 BRANCH CIRCUIT WIRIN6 TO NEW LOCATION WHERE
FOUND 5ERVIGEABLE.
6. MAINTAIN EXI5TIN6 DEVICE AND ASSOCIATED BRANCH GIRGUIT
WIRING.
,. REMOVE EXISTING DEVICE AND ASSOCIATED BRANCH GIRGUIT
WIRING.
b. EXI5TIN6 ELEGTRIGAL PANELS AND EQUIPMENT TO REMAIN.
REFER TO ELECTRICAL DEMOLITION NOTE 4 AND GENERAL
GON51FRUCTION NOTE Cl ON DRAWING EI-03. REFER TO ONE LINE
DIAGRAM ON DRAWING EI-03 FOR FURTHER INFORMATION.
cl. EXI5TIN6 2-DOOR GOOLER TO BE REMOVED AND RELOCATED
TO NEW LOCATION INDICATED ON DRAWING EI-03. REUSE AND
EXTEND EXISTING BRANCH CIRCUIT WIRIN6 WHERE FOUND
5ERVICEABLE. INSTALL NEW RECEPTACLE TO MATCH EXISTING.
10. EXI5TIN6 46" x 30" PREP COOLER TO BE REMOVED AND
RELOCATED TO NEW LOCATION INDICATED ON DRAWING EI-03,
REUSE AND EXTEND EXI5TIN6 BRANCH CIRCUIT WIRING WHERE
FOUND SERVICEABLE. INSTALL NEW RECEPTACLE TO MATCH
EXI5TIN6.
11. EXI5TIN6 4-HEAD VIPER FROZEN CARBONATED BE
DISPENSER TO BE REMOVED AND RELOCATED TO NEW
LOCATION INDICATED ON DRAWING EI-03. REUSE AND EXTEND
EXI5TIN6 BRANGH CIRCUIT WIRIN6 WHERE FOUND SERVICEABLE.
INSTALL NEW RECEPTACLE TO MATCH EXI5TIN6.
12. EXI5TIN6 20-HEAD POLAR POP FOUNTAIN TO BE REMOVED AND
RELOCATED TO NEW LOCATION INDICATED ON DRAWING EI-03.
REUSE AND EXTEND EX15TINC7BRANCH CIRCUIT WIRING WHERE
FOUND SERVICEABLE. INSTALL NEW RECEPTACLE TO MATCH
EXI5TIN6.
13. EXI5TIN6 ICE MACHINE ABOVE FOUNTAIN TO BE REMOVED AND
RELOCATED TO NEW LOCATION INDICATED ON DRAWING EI-03.
REUSE AND EXTEND EX15TINC7BRANCH CIRCUIT WIRING WHERE
FOUND SERVICEABLE. INSTALL NEW RECEPTACLE TO MATCH
EXI5TIN6.
14. EXI5TIN6 CAKE COOLER TO BE REMOVED AND RELOCATED TO
NEW LOCATION INDICATED ON DRAWING EI-03. RELOCATE
EXI5TIN6 POWER POLE TO NEW LOCATION. REUSE AND EXTEND
EXISTING BRANGH CIRCUIT WIRING WHERE FOUND SERVICEABLE.
15. EXI5TIN6 RED BULL COOLER TO BE REMOVED AND RELOCATED
TO NEW LOCATION INDICATED ON DRAWING EI-Ol RELOCATE
EXISTING POWER POLE TO IOW LOCATION. REUSE AND EXTEND
EXI5TIN6 BRANCH CIRCUIT WIRING WHERE FOUND SERVICEABLE.
16. MAINTAIN EXI5TIN6 GEILIN6-MOUNTED RECEPTACLE AND
ASSOCIATED BRANCH CIRCUIT WIRING,
IT. EXISTING GRADE -MOUNTED C.ONDEN51N0 UNIT FOR POLAR POP
ICE CUBER MACHINE REMAIN. MAINTAIN EXISTING DISCONNECT
SWITCH AND A550CIATED BRANCH CIRCUIT WIRING.
Ib. REMOVE EXI5TIN6 LOAD CENTER AND REPLACE WITH NEW
PANEL AT SAME LOCATION. REFER TO ELECTRICAL DEMOLITION
NOTE 4 AND GENERAL CONSTRUCTION NOTE cl. REFER TO ONE
LINE DIAGRAM ON DRAWING EI-04 FOR FURTHER INFORMATION.
19. EXTERIOR 517E LIGHTING AND CANOPY LIGHTING 15 EXISTING TO
REMAIN, UNLE55 OTHERWISE NOTED.
ELECTRICAL DEMOLITION NOTES
T
2. REPAIR AND RESTORE TO ORIGINAL CONDITION ALL ITEMS OR
PORTIONS OF ELEGTRIGAL WORK WHICH ARE NOT NOTED TO BE
DEMOLISHED, BUT ARE DAMAGED BY WORK UNDER THIS
CONTRACT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY
TO PROTECT AND RETAIN POWER TO ALL EXI51EIN6 ACTIVE
EQUIPMENT WHICH SHALL REMAIN. ELECTRICAL CONTRACTOR
SHALL RECONNECT ANY EQUIPMENT BEING DISTURBED BY TH15
RENOVATION.
3. WHERE WORK BY THE 6ENERAL CONTRACTOR (WALL REMOVAL,
NEW OR RELOCATED WALL OPENING, ETC), RESULTS IN THE
REMOVAL, RELOCATION, OR REFEEDIN6 OF ELECTRICAL
DEVIGE5 OR LIGHTING FIXTURES, THE ELECTRICAL CONTRACTOR
SHALL DISCONNECT OR RECONNECT AS REQUIRED ALL ACTIVE
DEVICES REMAINING ON THAT CIRCUIT.
4. CONTRACTOR VERIFY ALL GIRGUITS IN EXISTING PANEL
AFFECTED BY THI5 ALTERATION. WHERE ADDITIONAL CIROUITS
ARE NEEDED, USE AVAILABLE SPARE BREAKERS IN THE PANEL.
TIGHTEN ALL CONNECTIONS.
5. DO NOT PROCEED WITH DEMOLITION WITHOUT WRITTEN
AUTHORITY TO PROCEED. PROCEED WITH DEMOLITION IN A
SYSTEMATIC MANNER AND COORDINATE WITH ALL TRADES
INVOLVED. COORDINATE AND 5EOUENGE DEMOLITION 50 A5
NOT TO CAUSE A 5HUTDOWN OF OPERATION OF SURROUNDING
AREAS.
Q
T. ARRANGE TIMING OF SHUTDOWN PERIODS OF ALL IN-5ERVIGE
PANELS WITH OWNER OR HI5 REPRESENTATIVE. DO NOT
SHUTDOM ANY UTILITY WITHOUT PRIOR WRITTEN APPROVAL.
H. WHERE EXISTING, CIRCUITS ARE INDICATED TO BE REUSED,
CONTRACTOR TO USE SENSING MEASURING DEVICES TO VERIFY
THAT GIRCUITS FEED PROJECT AREA OR ARE NOT IN USE.
cl. REMOVE WIRING DEVIGE5 INDICATED ON PLAN WITH
ASSOCIATED GONDUIT AND WIRING UNLE55 OTHERWISE NOTED.
GENERAL CONSTRUCTION NOTES
I. OPEN WIRE AND OPEN GABLES INSTALLED WITHIN THE RETURN
AIR GEILIN6 SPACE SHALL BE PLENUM RATED LETTER CODE 'P'
AND WILL BE LOW -SMOKE PRODUCING.
2. ALL WIRE FOR POWER, LI&HTIN6 AND CONTROL SYSTEMS SHALL
BE (900VOLT THHN-THWN, 90' INSULATED AND SHALL BE
COPPER. ALL WIRE FOR COMMUNICATIONS SYSTEMS SHALL BE
COPPER.
3. FIRE SEAL OPENINGS AROUND ALL CONDUIT PENETRATIONS.
PENETRATIONS THROWN FIRE RATED CONSTRUCTION SHALL BE
SEALED WITH L15TED FIRE RATED MATERIALS.
4. EMT CONDUIT SHALL BE RUN IN ALL GEILIN6 SPACES. TYPE MG
GABLE MAY ONLY BE INSTALLED WHERE CONGEALED WITHIN
WALL 5PAGE5 OR GEILIN6 SPACES. CONNECTORS SHALL
EFFECTIVELY SEAL THE CONDUIT OPENIN65 WHERE INSTALLED IN
GEILIN6 SPACES USED FOR AIR HANDLING PURPOSES
5. ALL ELECTRICAL EQUIPMENT SHALL BE U.L. LISTED OR
LABELED.
6. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE
NATIONAL ELECTRIGAL CODE, AND ALL LOCAL ORDINANCES.
-1. ALL EXI5TIN6 CIRCUITS IN THE SPACE THAT ARE EXI5TIN6 TO
REMAIN SHALL BE TRACED WITH A GIRGUIT TESTER AND
PROPERLY IDENTIFIED ON ANEW PANEL DIREGTORY.
H. REMOVE ALL BRANCH CIRCUIT WIRE SHOWN TO BE REMOVED
ABOVE THE GEILIN6 SPACE BACK TO THE FIRST JUNGTION BOX
ON ALL DEVICES SHOWN TO BE REMOVED AS PART OF THI5
PROJECT,
Q. BRANCH CIRGOIT WIRING 15 DIA6RAMMATIG. PROVIDE NEW
CIRCUIT BREAKERS IN SPACES WITHIN PANEL BOARD5 SHOWN
OR UTILIZE SPARES MADE AVAILABLE AFTER DEMOLITION
PHASE. TYPE TO MATCH EXISTING. PROVIDE TYPED AGGURATE
PANEL BOARD DIREGTORIE5 FOR ALL PANELS NOTED.
10. PROVIDE 'HAGR' TYPE CIRCUIT BREAKERS FOR ALL
MECHANICAL EQUIPMENT.
11. PROVIDE BRANCH CIRCUIT BREAKERS IN THE EXI5TIN6 PANELS
AS REQUIRED TO RESUPPLY ALL EXI5TIN6 AND NEW STORE
LOADS. FIELD VERIFY BRANCH BREAKERS REQUIRED AND
RECONNECT AS REQUIRED.
12. THE ELECTRICAL CONTRACTOR SHALL MEASURE THE VOLTAGE
AND CURRENT ON ALL EXI5TIN6 PANEL BOARDS, AND BRANCH
CIRCUIT WIRING PRIOR TO THE INSTALLATION OF NEW WORK
SHOWN TO ENSURE THAT NO EXI5TIN6 PANEL 15 OVERLOADED
BY THE NEW WORK. PROVIDE WRITTEN DOCUMENTATION TO THE
ENGINEER AND PLANS EXAMINER OF HIS FINDINGS UPON
REGUE5T.
13. ALL UTILITY UPGRADE COSTS, M150ELLANEOU5 FEES, AND
COORDINATION 15 THE RESPONSIBILITY OF THE ELECTRICAL
CONTRACTOR
14. ALL NEW EQUIPMENT AND DEVICES SHALL BE AS APPROVED
AND SPECIFIED BY CIRCLE K AND ITS AFFILIATES. ALL
METHODS OF INSTALLATION SHALL COMPLY WITH CIRCLE K
STANDARDS AND ALL WORK 15 SUBJECT TO FINAL
ACCEPTANCE BY GIRDLE I
aaS51 Cu,As Blvd
Eastlake, ON 4I 5
t44)9530J60
!� ,,953,1209
,e<l l
Inc.
wen,®8ele,e"
clew llattl i oaema,
M
M
N
0Q
m
Na
�m
3gs
o'er
ro
��n
UN
�NZ
ai=oz
Y50
Z
N 4! 0c 4=
Li
E
Z L co
�N
OVCoU
dU r
U
82,
a
U
U
NN
NN
NN
rCID
�
�m
3c
mo
no
UE
oV
O1
Age
No.
No.
61
11700214;0;
A STATE OF (u
�DNAL F
ro
F
a
o
�
o
ry
0
H
z
o
�
a,
a
0
W
a
y
o
K
O
U.
W
Tn
co
0
m
z
4Z
J
i
J Z
M
Q O
U
J
H
W LLJ
J
wp��UO
poCw�
z Q
J LU
�U)ULUQ
0
DRAM By
CHECKEDe.
CUB
TGP
SGIE
114" = 11-0"
InUE [Ai
Joe NUMBER
18-603
DRAWNGNUMBER
E1-01