HomeMy WebLinkAboutE1-01PANEL PANEL 0 'W1111111 IIII L4 k BACKROOIIIIM (M IIkdk V w r 0 r ICE KNOWN ❑.FFFIIICCEE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel DATE: 03/07/19 EXISTING DISPENSER MANAGER PANEL EXISTING 19 UTILITY _J� r u L - - b M � m O \X//� XE L L 3 MERCHANDISING // 19 b / k / SUBWAY MANAGER ❑FFICE ELECTRICAL DEMOLITION PLAN SCALE: 1/4" = 1'-0' WOMEN ELECTRICAL SYMBOLS �A BRANCH CIRCUIT HOMERUN TO PANEL "A", CIRCUIT #3 AND #5. / 39 PROVIDE THE PROPER QUANTITY OF 12 AW6 CONDUCTORS PLUS 1-12 AY46 6ND FOR THE CIRGUIT(S) INDICATED. W DUPLEX RECEPTACLE - MOUNTING AT Ib' A.F.F. OR A5 NOTED V DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER O\ TWO 12OV, 20A DUPLEX RECEPTACLES MOUNTED IN A 2-6AN6 \ BOX AT lb" A.F.F. OR AS NOTED \ \ 36" \ W 120V, 20A DUPLEX RECEPTACLE -MOUNTING AT 36" A.F.F. \ 12OV, 20A DUPLEX RECEPTACLE WITH USB GHAR61N6 PORT - /' \\QD MOUNT AT b" BELOW WINDOW SILL AND COORDINATE FINAL / 4 \ LOCATION WITH GA5EWORK INSTALLATION PRIOR TO ROU6H-IN 1 / \ SPECIAL PURPOSEOUTLET. VERIFY GONFI6URATION WITH EQUIPMENT PROVIDED. - 4 \ 0 POWER POLE r--1 a L-J I SUBWAY SEATING \ \ 4 r / j \ 301 UNFUSED DISCONNECT SWITCH, 30 AMPERE, 3 POLE OR AS \ NOTED 4 v v ONELINE REPRESENTATION OF A MOLDED CASE CIRCUIT BREAKER, 51ZE AS NOTED PANELBOARD - O TO 150 VOLTS TO GROUND PLAN NOTE TAG, REFER TO PLAN FOR DESCRIPTION / A.F.F. ABOVE FINISHED FLOOR \ MGB MAIN CIRCUIT BREAKER / MLO MAIN LU35 ONLY / WP WP L-EATHERPROOF HEAVY LINE PEI&HT INDICATES THIS EQUIPMENT 15 NEW UNLESS NOTED OTHERWISE LIGHT LINE WE16HT INDICATES THI5 EQUIPMENT IS EXISTING UNLE55 NOTED OTHERWISE HEAVY DASHED LINE VEI&HT INDICATES THI5 EQUIPMENT 15 TO BE REMOVED UNLESS NOTED OTHEPH15E O PLAN NOTES I. EXCEPT WHERE 5PEGIFIGALLY INDICATED OTHERWISE, NO WORK IN THI5 AREA. MAINTAIN ALL EXISTING LUMINAIRES, CONTROLS, DEVICES, AND ASSOCIATED BRANCH GIRGUIT WIRIN6. 2. EXI5TIN6 WALK-IN COOLER TO REMAIN. MAINTAIN ALL EXI5TIN5 ASSOCIATED DEVICES AND BRANCH GIRGUIT WIRING. 3. MAINTAIN EXISTING LUMINAIRE, A550GIATED CONTROLS, AND BRANCH GIRGUIT WIRING. 4. REMOVE EXISTING LUMINAIRE, ASSOCIATED CONTROLS, AND BRANCH GIRGUIT WIRING. 5. EXI5TIN6 LUMINAIRE TO BE REMOVED AND RELOCATED TO NEW LOCATION INDIGATED ON DRAWING EI-02. REUSE AND EXTEND EXI5TIN6 BRANCH CIRCUIT WIRIN6 TO NEW LOCATION WHERE FOUND 5ERVIGEABLE. 6. MAINTAIN EXI5TIN6 DEVICE AND ASSOCIATED BRANCH GIRGUIT WIRING. ,. REMOVE EXISTING DEVICE AND ASSOCIATED BRANCH GIRGUIT WIRING. b. EXI5TIN6 ELEGTRIGAL PANELS AND EQUIPMENT TO REMAIN. REFER TO ELECTRICAL DEMOLITION NOTE 4 AND GENERAL GON51FRUCTION NOTE Cl ON DRAWING EI-03. REFER TO ONE LINE DIAGRAM ON DRAWING EI-03 FOR FURTHER INFORMATION. cl. EXI5TIN6 2-DOOR GOOLER TO BE REMOVED AND RELOCATED TO NEW LOCATION INDICATED ON DRAWING EI-03. REUSE AND EXTEND EXISTING BRANCH CIRCUIT WIRIN6 WHERE FOUND 5ERVICEABLE. INSTALL NEW RECEPTACLE TO MATCH EXISTING. 10. EXI5TIN6 46" x 30" PREP COOLER TO BE REMOVED AND RELOCATED TO NEW LOCATION INDICATED ON DRAWING EI-03, REUSE AND EXTEND EXI5TIN6 BRANCH CIRCUIT WIRING WHERE FOUND SERVICEABLE. INSTALL NEW RECEPTACLE TO MATCH EXI5TIN6. 11. EXI5TIN6 4-HEAD VIPER FROZEN CARBONATED BE DISPENSER TO BE REMOVED AND RELOCATED TO NEW LOCATION INDICATED ON DRAWING EI-03. REUSE AND EXTEND EXI5TIN6 BRANGH CIRCUIT WIRIN6 WHERE FOUND SERVICEABLE. INSTALL NEW RECEPTACLE TO MATCH EXI5TIN6. 12. EXI5TIN6 20-HEAD POLAR POP FOUNTAIN TO BE REMOVED AND RELOCATED TO NEW LOCATION INDICATED ON DRAWING EI-03. REUSE AND EXTEND EX15TINC7BRANCH CIRCUIT WIRING WHERE FOUND SERVICEABLE. INSTALL NEW RECEPTACLE TO MATCH EXI5TIN6. 13. EXI5TIN6 ICE MACHINE ABOVE FOUNTAIN TO BE REMOVED AND RELOCATED TO NEW LOCATION INDICATED ON DRAWING EI-03. REUSE AND EXTEND EX15TINC7BRANCH CIRCUIT WIRING WHERE FOUND SERVICEABLE. INSTALL NEW RECEPTACLE TO MATCH EXI5TIN6. 14. EXI5TIN6 CAKE COOLER TO BE REMOVED AND RELOCATED TO NEW LOCATION INDICATED ON DRAWING EI-03. RELOCATE EXI5TIN6 POWER POLE TO NEW LOCATION. REUSE AND EXTEND EXISTING BRANGH CIRCUIT WIRING WHERE FOUND SERVICEABLE. 15. EXI5TIN6 RED BULL COOLER TO BE REMOVED AND RELOCATED TO NEW LOCATION INDICATED ON DRAWING EI-Ol RELOCATE EXISTING POWER POLE TO IOW LOCATION. REUSE AND EXTEND EXI5TIN6 BRANCH CIRCUIT WIRING WHERE FOUND SERVICEABLE. 16. MAINTAIN EXI5TIN6 GEILIN6-MOUNTED RECEPTACLE AND ASSOCIATED BRANCH CIRCUIT WIRING, IT. EXISTING GRADE -MOUNTED C.ONDEN51N0 UNIT FOR POLAR POP ICE CUBER MACHINE REMAIN. MAINTAIN EXISTING DISCONNECT SWITCH AND A550CIATED BRANCH CIRCUIT WIRING. Ib. REMOVE EXI5TIN6 LOAD CENTER AND REPLACE WITH NEW PANEL AT SAME LOCATION. REFER TO ELECTRICAL DEMOLITION NOTE 4 AND GENERAL CONSTRUCTION NOTE cl. REFER TO ONE LINE DIAGRAM ON DRAWING EI-04 FOR FURTHER INFORMATION. 19. EXTERIOR 517E LIGHTING AND CANOPY LIGHTING 15 EXISTING TO REMAIN, UNLE55 OTHERWISE NOTED. ELECTRICAL DEMOLITION NOTES T 2. REPAIR AND RESTORE TO ORIGINAL CONDITION ALL ITEMS OR PORTIONS OF ELEGTRIGAL WORK WHICH ARE NOT NOTED TO BE DEMOLISHED, BUT ARE DAMAGED BY WORK UNDER THIS CONTRACT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROTECT AND RETAIN POWER TO ALL EXI51EIN6 ACTIVE EQUIPMENT WHICH SHALL REMAIN. ELECTRICAL CONTRACTOR SHALL RECONNECT ANY EQUIPMENT BEING DISTURBED BY TH15 RENOVATION. 3. WHERE WORK BY THE 6ENERAL CONTRACTOR (WALL REMOVAL, NEW OR RELOCATED WALL OPENING, ETC), RESULTS IN THE REMOVAL, RELOCATION, OR REFEEDIN6 OF ELECTRICAL DEVIGE5 OR LIGHTING FIXTURES, THE ELECTRICAL CONTRACTOR SHALL DISCONNECT OR RECONNECT AS REQUIRED ALL ACTIVE DEVICES REMAINING ON THAT CIRCUIT. 4. CONTRACTOR VERIFY ALL GIRGUITS IN EXISTING PANEL AFFECTED BY THI5 ALTERATION. WHERE ADDITIONAL CIROUITS ARE NEEDED, USE AVAILABLE SPARE BREAKERS IN THE PANEL. TIGHTEN ALL CONNECTIONS. 5. DO NOT PROCEED WITH DEMOLITION WITHOUT WRITTEN AUTHORITY TO PROCEED. PROCEED WITH DEMOLITION IN A SYSTEMATIC MANNER AND COORDINATE WITH ALL TRADES INVOLVED. COORDINATE AND 5EOUENGE DEMOLITION 50 A5 NOT TO CAUSE A 5HUTDOWN OF OPERATION OF SURROUNDING AREAS. Q T. ARRANGE TIMING OF SHUTDOWN PERIODS OF ALL IN-5ERVIGE PANELS WITH OWNER OR HI5 REPRESENTATIVE. DO NOT SHUTDOM ANY UTILITY WITHOUT PRIOR WRITTEN APPROVAL. H. WHERE EXISTING, CIRCUITS ARE INDICATED TO BE REUSED, CONTRACTOR TO USE SENSING MEASURING DEVICES TO VERIFY THAT GIRCUITS FEED PROJECT AREA OR ARE NOT IN USE. cl. REMOVE WIRING DEVIGE5 INDICATED ON PLAN WITH ASSOCIATED GONDUIT AND WIRING UNLE55 OTHERWISE NOTED. GENERAL CONSTRUCTION NOTES I. OPEN WIRE AND OPEN GABLES INSTALLED WITHIN THE RETURN AIR GEILIN6 SPACE SHALL BE PLENUM RATED LETTER CODE 'P' AND WILL BE LOW -SMOKE PRODUCING. 2. ALL WIRE FOR POWER, LI&HTIN6 AND CONTROL SYSTEMS SHALL BE (900VOLT THHN-THWN, 90' INSULATED AND SHALL BE COPPER. ALL WIRE FOR COMMUNICATIONS SYSTEMS SHALL BE COPPER. 3. FIRE SEAL OPENINGS AROUND ALL CONDUIT PENETRATIONS. PENETRATIONS THROWN FIRE RATED CONSTRUCTION SHALL BE SEALED WITH L15TED FIRE RATED MATERIALS. 4. EMT CONDUIT SHALL BE RUN IN ALL GEILIN6 SPACES. TYPE MG GABLE MAY ONLY BE INSTALLED WHERE CONGEALED WITHIN WALL 5PAGE5 OR GEILIN6 SPACES. CONNECTORS SHALL EFFECTIVELY SEAL THE CONDUIT OPENIN65 WHERE INSTALLED IN GEILIN6 SPACES USED FOR AIR HANDLING PURPOSES 5. ALL ELECTRICAL EQUIPMENT SHALL BE U.L. LISTED OR LABELED. 6. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRIGAL CODE, AND ALL LOCAL ORDINANCES. -1. ALL EXI5TIN6 CIRCUITS IN THE SPACE THAT ARE EXI5TIN6 TO REMAIN SHALL BE TRACED WITH A GIRGUIT TESTER AND PROPERLY IDENTIFIED ON ANEW PANEL DIREGTORY. H. REMOVE ALL BRANCH CIRCUIT WIRE SHOWN TO BE REMOVED ABOVE THE GEILIN6 SPACE BACK TO THE FIRST JUNGTION BOX ON ALL DEVICES SHOWN TO BE REMOVED AS PART OF THI5 PROJECT, Q. BRANCH CIRGOIT WIRING 15 DIA6RAMMATIG. PROVIDE NEW CIRCUIT BREAKERS IN SPACES WITHIN PANEL BOARD5 SHOWN OR UTILIZE SPARES MADE AVAILABLE AFTER DEMOLITION PHASE. TYPE TO MATCH EXISTING. PROVIDE TYPED AGGURATE PANEL BOARD DIREGTORIE5 FOR ALL PANELS NOTED. 10. PROVIDE 'HAGR' TYPE CIRCUIT BREAKERS FOR ALL MECHANICAL EQUIPMENT. 11. PROVIDE BRANCH CIRCUIT BREAKERS IN THE EXI5TIN6 PANELS AS REQUIRED TO RESUPPLY ALL EXI5TIN6 AND NEW STORE LOADS. FIELD VERIFY BRANCH BREAKERS REQUIRED AND RECONNECT AS REQUIRED. 12. THE ELECTRICAL CONTRACTOR SHALL MEASURE THE VOLTAGE AND CURRENT ON ALL EXI5TIN6 PANEL BOARDS, AND BRANCH CIRCUIT WIRING PRIOR TO THE INSTALLATION OF NEW WORK SHOWN TO ENSURE THAT NO EXI5TIN6 PANEL 15 OVERLOADED BY THE NEW WORK. PROVIDE WRITTEN DOCUMENTATION TO THE ENGINEER AND PLANS EXAMINER OF HIS FINDINGS UPON REGUE5T. 13. ALL UTILITY UPGRADE COSTS, M150ELLANEOU5 FEES, AND COORDINATION 15 THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR 14. ALL NEW EQUIPMENT AND DEVICES SHALL BE AS APPROVED AND SPECIFIED BY CIRCLE K AND ITS AFFILIATES. ALL METHODS OF INSTALLATION SHALL COMPLY WITH CIRCLE K STANDARDS AND ALL WORK 15 SUBJECT TO FINAL ACCEPTANCE BY GIRDLE I aaS51 Cu,As Blvd Eastlake, ON 4I 5 t44)9530J60 !� ,,953,1209 ,e<l l Inc. wen,®8ele,e" clew llattl i oaema, M M N 0Q m Na �m 3gs o'er ro ��n UN �NZ ai=oz Y50 Z N 4! 0c 4= Li E Z L co �N OVCoU dU r U 82, a U U NN NN NN rCID � �m 3c mo no UE oV O1 Age No. No. 61 11700214;0; A STATE OF (u �DNAL F ro F a o � o ry 0 H z o � a, a 0 W a y o K O U. W Tn co 0 m z 4Z J i J Z M Q O U J H W LLJ J wp��UO poCw� z Q J LU �U)ULUQ 0 DRAM By CHECKEDe. CUB TGP SGIE 114" = 11-0" InUE [Ai Joe NUMBER 18-603 DRAWNGNUMBER E1-01