HomeMy WebLinkAboutOBF-073 ENERGYIECC 2009 Performance Compliance
Property
14377 OVERBROOK DR
CARMEL, IN 46074
OBF73 (AS DESIGNED)
OVERBROOK FARMS 73
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$2,736
$378
$244
$3,357
$1,854
$D
$5,211
Requirements
C4405.3
Performance-based compliance passes by 9.1%
402.4.12
Air Leakage Testing
C4402.5
Area -weighted average fenestration SHGG
402.5
Area -weighted average fenestration U -Factor
40322
Duct Testing
C4
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
C-M,
Energy Solutions
As Designed
$2,458
$351
$244
$3,052
$1,854
$D
$4,906
Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
design exceeds requirements for IECC 2009 Performance compliance by 9.1%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
1124119 at 4:18 PM
Ekotrope RATER - Version 3.1.0.2095
IECC 2009 Performance compliance results calculated using Ekotrope s energy algorithm; which is a RESNET Accredited HERS Rating Tool.
14377 OVERBROOK DR
CARMEL, IN 46074
FISCHER HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-10
Framed Floor R-30
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.31, SHGC: 0.29
Building Features
Duct Supply R-6.0, Return R-0.0
Duct Leakage to Outside 255.0 CFM cQ 25Pa
Total Duct Leakage 376.0 CFM cQ 25Pa
Heating Furnace • Natural Gas • 96.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Natural Gas • 0.64 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Narne
Michael Hill
Organization: TSI Energy Solutions
Signature:
Date: 1 /241 19 at 4:18 P M
Ekotrope RATER - Version 3.1.0.2095
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESNETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property organization
14377 OVERBROOK DR TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Michael Hill
OBF73 (AS DESIGNED)
OVERBROOK FARMS 73 Builder
FISCHER HOMES
General Building Information
Conditioned Area (sq ft) 8,330
Conditioned Volume (cubic ft) 80,480
Insulated Shell Area (sq ft) 14,947
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
] Name: BSMT (2,795 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: GARAGE (555 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
Foundation Wall
Name: CON DIAMB (Exterior Perimeter [ft]: 215, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 10.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
]l Name: CON DIGAR (Exterior Perimeter [ft]: 57, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 10.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDfAMB (3,571 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2X6 (731 s.f.)
R-0.41 continuous insulation, R-19 cavity insulation 1
Insulation Grade: I
Energy Code Inspection Checklist
Property
14377 OVERBROOK DR
CARMEL, IN 46074
OBF73 (AS DESIGNED)
OVERBROOK FARMS 73
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Name: CONDIGAR (513 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (463 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
Name: CONDIAMB (410 s.f.)
R: 15.414
E] Name: CONDIGAR (57 s.f.)
R: 15.414
Name: CONDIATTIC (54 s.f.)
R: 15.414
Roof
El Name: MAIN (3,350 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
E] Name: FRONT (48 s.f.)
U: 0.182
Name: GARAGE (20 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
El Name: FRONT (96 s.f.), U:0.310, SHGC: 0.26, Orientation: EAST
El Name: FRONT RIGHT (32 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH—EAST
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
C-M
Energy Solutions
Property organization
14377 OVERBROOK DR TSI Energy Solutions
CARMEL, IN 46074 317-846-4655 Inspection Status
Michael Hill Results are projected
OBF73 (AS DESIGNED)
OVERBROOK FARMS 73 Builder
FISCHER HOMES
Name: FRONT LEFT (32 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH—WEST
E] Name: BACK (169 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST
El Name: BACK 2X6 (118 s.f.), J:0.310, SHGC: 0.29, Orientation: WEST
El Name: RIGHT (120 s.f.), J:0.310, SHGC: 0.29, Orientation: NORTH
El Name: RIGHT GD (20 s.f.), U:0.290, SHGC: 0.33, Orientation: NORTH
El Name: LEFT (1111 s.f.), J:0.310, SHGC: 0.29, Orientation: SOUTH
Name: LEFT 2X6 (16 s.f.), U:0.310, SHGC: 0.29, Orientation: SOUTH
Name: BACK BSMT (30 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST
Skylight
No ne Present
Mechanical Ventilation
None Present
Mechanical Equipment
El Fuel -fired air distribution (1) • Natural Gas • 50% Heating Load @ 96.1 AFUE
El Fuel -fired air distribution (2) • Natural Gas • 50% Heating Load @ 96.1 AFUE
E] Air conditioner (3) • Electric • 50% Cooling Load @ 13 SEER
E] Air conditioner (4) • Electric • 50% Cooling Load @ 13 SEER
El Water Heating (5) • Natural Gas • 100% Hot Water Load @ 0.64 Energy Factor 3
Air Leakage Control
Energy Code Inspection Checklist
Property
14377 OVERBROOK DR
CARMEL, IN 46074
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
OBF73 (AS DESIGNED)
OVERBROOK FARMS 73 Builder
FISCHER HOMES
Inspection Status
Results are projected
ElTest Status: Blower -door tested
House is air -sealed as to achieve 6,707 CFM50 (5.00 AC H50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
Entirely within conditioned space
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 255.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 376.0 CFM @ 25Pa
Duct System 2
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 186.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 232.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
CTSI
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
4
Project Notes
Building Summary
C-M
Energy Solutions
Property Organization
14377 OVERBROOK DR TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Michael Hill Inspection Status
OBF73 [AS DESIGNED] Results are projected
OVERBROOK FARMS 73 Builder
FISCHER HOMES
General Building Information
Number Of Bedrooms 5
Number Of Floors 2
Conditioned Floor Area [sq. ft.] 8,330
Unconditioned, attached garage? Yes
Conditioned Volume [cu. ft.] 80;480
Total Units in Building 1
Residence Type Single family detached
Model JAMESON
Community OVERBROOK FARMS 73
Climate Zone 5A
Basement Wali
Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing
CONDIAMB R-10 Draped, 4f[ 1 8 215 Exposed Exterior Conditioned Space
CONDIGAR R-10 Draped, 4f[ 1 8 57 Exposed Exterior Condttioned Space
Basement Wall Library List
Name Feet From Wall Tap To Insulation Feet From Wall Top To Insulation Is Fully Insulated R-value
Top Bottom
R-10 Draped, 4f[ ❑ 4 No 10.00
Sla
Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated 272 Below Grade 0 0 2,795.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Library List
Name Wall Construction Type Slab Complete l Underslab Insulation Perimeter Insulation Perimeter Insulation R R-value
Insulated. Width [it] Depth [ft] Value
Uninsulated Wood Frame / Other No 0 0 6 0.00
1
Building Summary
Property Organization
14377 OVERBROOK DR TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Michael Hill
OBF73 [AS DESIGNED]
OVERBROOK FARMS 73 Builder
FISCHER HOMES
Framed Floor
Name Library Type Ca
,.::.R' —E R-30, GR1
Framed Floor Library List Am
Name R -value
R-30, GR1 27.493
Inspection Status
Results are projected
)et R Floor Grace
123 Above Grade
C-M,
Energy Solutions
ur race Area Location
555.0 sq. fL Unconditioned, attached
garage
Rim Joist =IF
Name L i b rary Type Surface Area Location
CONDIAMB G1 R-19, OSB 410.0 sq. ft. Exposed Exterior
CONDIATTIC G1 R-19, OSB
CONDIGAR G1 R-19, OSB
Rim Joist Library List
Name Ravalue
G1 R-19, OSB 15.414
54.0 sq. ft. Attic
57.0 sq. 11 Unconditioned, attached garage
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
G1 R-15 BATT, T- PLY
Medium
3.571.0 sq. ft.
Exposed Exterior
CONDIAMB 2X6
G1 R-19 BATT, T -PLY
Medium
731.0 sq. ft.
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, T- PLY
Medium
463.0 sq. ft.
Attic
CONDIGAR
G1 R-15 Gar Walls
Medium
513.0 sq. ft.
Unconditioned, attached garage
2
Building Summary
C-M
Energy Solutions
Property Organization
14377 OVERBROOK DR TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Michael Hill Inspection Status
OBF73 [AS DESIGNED] Results are projected
OVERBROOK FARMS 73 Builder
FISCHER HOMES
F
List
Name R -value
BATT, T -PLY 12842
15 GarWalls 11.972
BATT, T -PLY 17278
Glazing
Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area
Assignment Top Bottom
BACK U-.31, SHGG29 CONDIAMB 0 0 0 West 169.0 sq. ft.
BACK 2X6 U-.31, SHGG29 CONDIAMB 2X6 0 0 0 West 118.0 sq. ft.
BACK BSMT U-.31, SHGG29 CONDIAMB 0 0 0 West 30.0 sq. R
FRONT U-.31, SHGC-26 CONDIAMB 0 0 0 East 96.0 sq. ft
FRONT LEFT U-.31, SHGG29 CONDIAMB 0 0 0 Northwest 32.0 sq. fL
FRONT RIGHT U-.31, SHGG29 CONDIAMB 0 0 0 Northeast 32.0 sq. R
LEFT U-.31, SHGG29 CONDIAMB 0 0 0 South 111.0 sq. ft.
LEFT 2X6 U-.31, SHGG29 CONDIAMB 2X6 0 0 0 South 16.0 sq. R
RIGHT U-.31, SHGG29 CONDIAMB 0 0 0 North 1200.sq. ft.
RIGHT GD U-29, SHGG.33 CONDIAMB 0 0 0 North 20.0 sq. ft
Glazing Library Li
Name Shg c U -factor
U-29, SHGC-.33 0.33 0290
U-.31, SHGC-26 026 0.310
U-.31, SHGC-29 029 0.310
3
Building Summary
Property
Organization
14377 OVERBROOK DR
TSI Energy Solutions
CARMEL, IN 46074
317-846-4655
Michael Hill
OBF73 [AS DESIGNED]
OVERBROOK FARMS 73
Builder
FISCHER HOMES
kylight
Skylight Library List
None
Opaque Door
Name Library Type Wall Assignment
Basement Wall
Assign ment
FRONT Steel Door
CONDIAMB
GARAGE Steel Door
CONDIGAR
Opaque Door Library List
Name
U •factor
S,:e-1 D:-::-: 1
0.182
C-M,
Energy Solutions
Inspection Status
Results are projected
Solar Surface Color Surface Area Location
Ab sorpta n ce
0.9 0.75 Medium 48.0 sq_ fl- Exposed Exterior
0.9 0.75 Medium 20.0 sq_ ft Exposed Exterior
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof
1 .11 Tiles
MAIN R-38 Blown. GR1 3.350
n
No Medium 3.350.0 sq. PL Attic
Roof Insulation Library List
Name Has Radiant Barrier R -value
R-38 Blown. GR I No 38265
4
Building Summary
Property
14377 OVERBROOK DR
CARMEL, IN 46074
OBF73 [AS DESIGNED]
OVERBROOK FARMS 73
Whale House Infiltration)
nfiltration
' 5 ACH at 517 Pa
Mechanical Ventilation
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Inspection Status
Results are projected
Blower -door tested 4
Lighting
% Interior Fluorescent % Interior LED Lightin4
Lighting
Onsite Generation
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
or Fluorescent % Exterior LED Lighting
Lighting
9 a
C-M,
Energy Solutions
Lighting - -
a o
A
Building Summary
C-M
Energy Solutions
Property Organization
14377 OVERBROOK DR TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Michael Hill Inspection Status
OBF73 [AS DESIGNED] Results are projected
OVERBROOK FARMS 73 Builder
FISCHER HOMES
onditioning Equipment
Name Library Type Heating Percent Load Coaling Percent Lead Hot Water Percent Load
Air conditioner [3] GSX130361A 0% 50% 0%
Air conditioner [4] GSX730361A 095 541a 0%
Fuel -fired air GMSS961005CN 50% 0% 0%
distribution [1]
Fuel -fired air GMSS961005CN 50% 0% 0%
distribution [2]
Water Heating [5] RG1 PV505'N 0% 0% 100%
Equipment Type: GMSS961005CN
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSC (Single Speed)
Heating Efficiency 96.1 AFUE
Heating Capacity [kBtulh] 96
Use default EAE No
EAE [kWh] 1;077
quipment Type: GSX130361A
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSC [Single Speed]
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 35
Equipment Type: RG1PV505*N
Fuel Type Natural Gas
Distribution Type Hydronic Delivery
Hot Water Efficiency 0.64 Energy Factor
Tank Capacity (gal.) 50
Hot Water Capacity [kBtulh] 40
Recovery Efficiency 0.80
6
Building Summary
Property
Organization
14377 OVERBROOK DR
TSI Energy Solutions
CARMEL, IN 46074
317-846-4655
Sq. Feet Served
Michael Hill Inspection Status
OBF73 [AS DESIGNED]
Results are projected
OVERBROOK FARMS 73
Builder
Return Duct R Value
FISCHER HOMES
Eistributivn System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution (1)
Cooling Equipment
Air conditioner (3)
Sq. Feet Served
5190
# Return Grilles
4
Supply Duct R Value
6
Return Duct R Value
6
Supply Duct Area [sq. ft.]
485
Return Duct Area [sq. ft_]
359.3
Duct Leakage to Outdoors (CFM25)
255
Total Leakage
376
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
166
Percent Return Area
166
Duct2
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
C-M,
Energy Solutions
7
Building Summary
Property
Organization
14377 OVERBROOK DR
TSI Energy Solutions
CARMEL, IN 46074
317-846-4655
Sq. Feet Served
Michael Hill Inspection Status
OBF73 [AS DESIGNED]
Results are projected
OVERBROOK FARMS 73
Builder
Return Duct R Value
FISCHER HOMES
Vistribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution (2)
Cooling Equipment
Air conditioner (4)
Sq. Feet Served
3140
4 Return Grilles
4
Supply Duct R Value
30
Return Duct R Value
30
Supply Duct Area [sq. ft.]
297.7
Return Duct Area [sq. ft_]
220.5
Duct Leakage to Outdoors (CFM25)
186
Total Leakage
232
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
16
Percent Return Area
16
Duct2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
96
Percent Return Area
90
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Ceiling Fan
Has Ceiling Fan No
Cfm Per Watt 144
ater Distribution
�ter
Fixture Type
Standard
e Default Hot Water Pipe Length
No
t Water Pipe Length [ft]
I
144
Least R3 Pipe Insulation?
No
t Water Recirculation System?
No
circulation System Pipe Loop Length [ft]
20
in Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
14377 OVERBROOK DR
CARMEL, IN 46074
OBF73 [AS DESIGNED]
OVERBROOK FARMS 73
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Notes
Organization
TSI Energy Solutions
317-846-4655
Michael Hill Inspection Status
Results are projected
Builder
FISCHER HOMES
Elec tric
2.62
Timer Controls
704 kWhlYear
0.081kWh
$23.00
$0.581Therm
2.874
0.331
Yes
270 kWh
Natural Gas
No
No
709 kWhlYear
C-M,
Energy Solutions