Loading...
HomeMy WebLinkAboutOBF-073 ENERGYIECC 2009 Performance Compliance Property 14377 OVERBROOK DR CARMEL, IN 46074 OBF73 (AS DESIGNED) OVERBROOK FARMS 73 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $2,736 $378 $244 $3,357 $1,854 $D $5,211 Requirements C4405.3 Performance-based compliance passes by 9.1% 402.4.12 Air Leakage Testing C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration U -Factor 40322 Duct Testing C4 Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation C-M, Energy Solutions As Designed $2,458 $351 $244 $3,052 $1,854 $D $4,906 Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. design exceeds requirements for IECC 2009 Performance compliance by 9.1%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 1124119 at 4:18 PM Ekotrope RATER - Version 3.1.0.2095 IECC 2009 Performance compliance results calculated using Ekotrope s energy algorithm; which is a RESNET Accredited HERS Rating Tool. 14377 OVERBROOK DR CARMEL, IN 46074 FISCHER HOMES Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-10 Framed Floor R-30 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.29 Building Features Duct Supply R-6.0, Return R-0.0 Duct Leakage to Outside 255.0 CFM cQ 25Pa Total Duct Leakage 376.0 CFM cQ 25Pa Heating Furnace • Natural Gas • 96.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Natural Gas • 0.64 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Narne Michael Hill Organization: TSI Energy Solutions Signature: Date: 1 /241 19 at 4:18 P M Ekotrope RATER - Version 3.1.0.2095 No version of this software has been reviewed or approved by ICC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC'). This software is a RESNETAccredited HERS Rating Tool. Energy Code Inspection Checklist Property organization 14377 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill OBF73 (AS DESIGNED) OVERBROOK FARMS 73 Builder FISCHER HOMES General Building Information Conditioned Area (sq ft) 8,330 Conditioned Volume (cubic ft) 80,480 Insulated Shell Area (sq ft) 14,947 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT (2,795 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: GARAGE (555 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Foundation Wall Name: CON DIAMB (Exterior Perimeter [ft]: 215, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 10.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 ]l Name: CON DIGAR (Exterior Perimeter [ft]: 57, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 10.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDfAMB (3,571 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (731 s.f.) R-0.41 continuous insulation, R-19 cavity insulation 1 Insulation Grade: I Energy Code Inspection Checklist Property 14377 OVERBROOK DR CARMEL, IN 46074 OBF73 (AS DESIGNED) OVERBROOK FARMS 73 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Name: CONDIGAR (513 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CONDIATTIC (463 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (410 s.f.) R: 15.414 E] Name: CONDIGAR (57 s.f.) R: 15.414 Name: CONDIATTIC (54 s.f.) R: 15.414 Roof El Name: MAIN (3,350 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door E] Name: FRONT (48 s.f.) U: 0.182 Name: GARAGE (20 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (96 s.f.), U:0.310, SHGC: 0.26, Orientation: EAST El Name: FRONT RIGHT (32 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH—EAST C-M, Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property organization 14377 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Inspection Status Michael Hill Results are projected OBF73 (AS DESIGNED) OVERBROOK FARMS 73 Builder FISCHER HOMES Name: FRONT LEFT (32 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH—WEST E] Name: BACK (169 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST El Name: BACK 2X6 (118 s.f.), J:0.310, SHGC: 0.29, Orientation: WEST El Name: RIGHT (120 s.f.), J:0.310, SHGC: 0.29, Orientation: NORTH El Name: RIGHT GD (20 s.f.), U:0.290, SHGC: 0.33, Orientation: NORTH El Name: LEFT (1111 s.f.), J:0.310, SHGC: 0.29, Orientation: SOUTH Name: LEFT 2X6 (16 s.f.), U:0.310, SHGC: 0.29, Orientation: SOUTH Name: BACK BSMT (30 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST Skylight No ne Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution (1) • Natural Gas • 50% Heating Load @ 96.1 AFUE El Fuel -fired air distribution (2) • Natural Gas • 50% Heating Load @ 96.1 AFUE E] Air conditioner (3) • Electric • 50% Cooling Load @ 13 SEER E] Air conditioner (4) • Electric • 50% Cooling Load @ 13 SEER El Water Heating (5) • Natural Gas • 100% Hot Water Load @ 0.64 Energy Factor 3 Air Leakage Control Energy Code Inspection Checklist Property 14377 OVERBROOK DR CARMEL, IN 46074 Organization TSI Energy Solutions 317-846-4655 Michael Hill OBF73 (AS DESIGNED) OVERBROOK FARMS 73 Builder FISCHER HOMES Inspection Status Results are projected ElTest Status: Blower -door tested House is air -sealed as to achieve 6,707 CFM50 (5.00 AC H50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 Entirely within conditioned space Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 255.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 376.0 CFM @ 25Pa Duct System 2 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 186.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 232.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): CTSI Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. 4 Project Notes Building Summary C-M Energy Solutions Property Organization 14377 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill Inspection Status OBF73 [AS DESIGNED] Results are projected OVERBROOK FARMS 73 Builder FISCHER HOMES General Building Information Number Of Bedrooms 5 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 8,330 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 80;480 Total Units in Building 1 Residence Type Single family detached Model JAMESON Community OVERBROOK FARMS 73 Climate Zone 5A Basement Wali Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-10 Draped, 4f[ 1 8 215 Exposed Exterior Conditioned Space CONDIGAR R-10 Draped, 4f[ 1 8 57 Exposed Exterior Condttioned Space Basement Wall Library List Name Feet From Wall Tap To Insulation Feet From Wall Top To Insulation Is Fully Insulated R-value Top Bottom R-10 Draped, 4f[ ❑ 4 No 10.00 Sla Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 272 Below Grade 0 0 2,795.0 sq. ft. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Type Slab Complete l Underslab Insulation Perimeter Insulation Perimeter Insulation R R-value Insulated. Width [it] Depth [ft] Value Uninsulated Wood Frame / Other No 0 0 6 0.00 1 Building Summary Property Organization 14377 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill OBF73 [AS DESIGNED] OVERBROOK FARMS 73 Builder FISCHER HOMES Framed Floor Name Library Type Ca ,.::.R' —E R-30, GR1 Framed Floor Library List Am Name R -value R-30, GR1 27.493 Inspection Status Results are projected )et R Floor Grace 123 Above Grade C-M, Energy Solutions ur race Area Location 555.0 sq. fL Unconditioned, attached garage Rim Joist =IF Name L i b rary Type Surface Area Location CONDIAMB G1 R-19, OSB 410.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-19, OSB CONDIGAR G1 R-19, OSB Rim Joist Library List Name Ravalue G1 R-19, OSB 15.414 54.0 sq. ft. Attic 57.0 sq. 11 Unconditioned, attached garage Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-15 BATT, T- PLY Medium 3.571.0 sq. ft. Exposed Exterior CONDIAMB 2X6 G1 R-19 BATT, T -PLY Medium 731.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-15 BATT, T- PLY Medium 463.0 sq. ft. Attic CONDIGAR G1 R-15 Gar Walls Medium 513.0 sq. ft. Unconditioned, attached garage 2 Building Summary C-M Energy Solutions Property Organization 14377 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill Inspection Status OBF73 [AS DESIGNED] Results are projected OVERBROOK FARMS 73 Builder FISCHER HOMES F List Name R -value BATT, T -PLY 12842 15 GarWalls 11.972 BATT, T -PLY 17278 Glazing Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK U-.31, SHGG29 CONDIAMB 0 0 0 West 169.0 sq. ft. BACK 2X6 U-.31, SHGG29 CONDIAMB 2X6 0 0 0 West 118.0 sq. ft. BACK BSMT U-.31, SHGG29 CONDIAMB 0 0 0 West 30.0 sq. R FRONT U-.31, SHGC-26 CONDIAMB 0 0 0 East 96.0 sq. ft FRONT LEFT U-.31, SHGG29 CONDIAMB 0 0 0 Northwest 32.0 sq. fL FRONT RIGHT U-.31, SHGG29 CONDIAMB 0 0 0 Northeast 32.0 sq. R LEFT U-.31, SHGG29 CONDIAMB 0 0 0 South 111.0 sq. ft. LEFT 2X6 U-.31, SHGG29 CONDIAMB 2X6 0 0 0 South 16.0 sq. R RIGHT U-.31, SHGG29 CONDIAMB 0 0 0 North 1200.sq. ft. RIGHT GD U-29, SHGG.33 CONDIAMB 0 0 0 North 20.0 sq. ft Glazing Library Li Name Shg c U -factor U-29, SHGC-.33 0.33 0290 U-.31, SHGC-26 026 0.310 U-.31, SHGC-29 029 0.310 3 Building Summary Property Organization 14377 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill OBF73 [AS DESIGNED] OVERBROOK FARMS 73 Builder FISCHER HOMES kylight Skylight Library List None Opaque Door Name Library Type Wall Assignment Basement Wall Assign ment FRONT Steel Door CONDIAMB GARAGE Steel Door CONDIGAR Opaque Door Library List Name U •factor S,:e-1 D:-::-: 1 0.182 C-M, Energy Solutions Inspection Status Results are projected Solar Surface Color Surface Area Location Ab sorpta n ce 0.9 0.75 Medium 48.0 sq_ fl- Exposed Exterior 0.9 0.75 Medium 20.0 sq_ ft Exposed Exterior Roof Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof 1 .11 Tiles MAIN R-38 Blown. GR1 3.350 n No Medium 3.350.0 sq. PL Attic Roof Insulation Library List Name Has Radiant Barrier R -value R-38 Blown. GR I No 38265 4 Building Summary Property 14377 OVERBROOK DR CARMEL, IN 46074 OBF73 [AS DESIGNED] OVERBROOK FARMS 73 Whale House Infiltration) nfiltration ' 5 ACH at 517 Pa Mechanical Ventilation Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Inspection Status Results are projected Blower -door tested 4 Lighting % Interior Fluorescent % Interior LED Lightin4 Lighting Onsite Generation None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List or Fluorescent % Exterior LED Lighting Lighting 9 a C-M, Energy Solutions Lighting - - a o A Building Summary C-M Energy Solutions Property Organization 14377 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Michael Hill Inspection Status OBF73 [AS DESIGNED] Results are projected OVERBROOK FARMS 73 Builder FISCHER HOMES onditioning Equipment Name Library Type Heating Percent Load Coaling Percent Lead Hot Water Percent Load Air conditioner [3] GSX130361A 0% 50% 0% Air conditioner [4] GSX730361A 095 541a 0% Fuel -fired air GMSS961005CN 50% 0% 0% distribution [1] Fuel -fired air GMSS961005CN 50% 0% 0% distribution [2] Water Heating [5] RG1 PV505'N 0% 0% 100% Equipment Type: GMSS961005CN Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSC (Single Speed) Heating Efficiency 96.1 AFUE Heating Capacity [kBtulh] 96 Use default EAE No EAE [kWh] 1;077 quipment Type: GSX130361A Fuel Type Electric Distribution Type Forced Air Motor Type PSC [Single Speed] Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 35 Equipment Type: RG1PV505*N Fuel Type Natural Gas Distribution Type Hydronic Delivery Hot Water Efficiency 0.64 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 40 Recovery Efficiency 0.80 6 Building Summary Property Organization 14377 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Sq. Feet Served Michael Hill Inspection Status OBF73 [AS DESIGNED] Results are projected OVERBROOK FARMS 73 Builder Return Duct R Value FISCHER HOMES Eistributivn System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution (1) Cooling Equipment Air conditioner (3) Sq. Feet Served 5190 # Return Grilles 4 Supply Duct R Value 6 Return Duct R Value 6 Supply Duct Area [sq. ft.] 485 Return Duct Area [sq. ft_] 359.3 Duct Leakage to Outdoors (CFM25) 255 Total Leakage 376 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 166 Percent Return Area 166 Duct2 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ C-M, Energy Solutions 7 Building Summary Property Organization 14377 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Sq. Feet Served Michael Hill Inspection Status OBF73 [AS DESIGNED] Results are projected OVERBROOK FARMS 73 Builder Return Duct R Value FISCHER HOMES Vistribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution (2) Cooling Equipment Air conditioner (4) Sq. Feet Served 3140 4 Return Grilles 4 Supply Duct R Value 30 Return Duct R Value 30 Supply Duct Area [sq. ft.] 297.7 Return Duct Area [sq. ft_] 220.5 Duct Leakage to Outdoors (CFM25) 186 Total Leakage 232 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 16 Percent Return Area 16 Duct2 Duct Location Attic (well vented; under insulation) Percent Supply Area 96 Percent Return Area 90 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Ceiling Fan Has Ceiling Fan No Cfm Per Watt 144 ater Distribution �ter Fixture Type Standard e Default Hot Water Pipe Length No t Water Pipe Length [ft] I 144 Least R3 Pipe Insulation? No t Water Recirculation System? No circulation System Pipe Loop Length [ft] 20 in Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 14377 OVERBROOK DR CARMEL, IN 46074 OBF73 [AS DESIGNED] OVERBROOK FARMS 73 Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Notes Organization TSI Energy Solutions 317-846-4655 Michael Hill Inspection Status Results are projected Builder FISCHER HOMES Elec tric 2.62 Timer Controls 704 kWhlYear 0.081kWh $23.00 $0.581Therm 2.874 0.331 Yes 270 kWh Natural Gas No No 709 kWhlYear C-M, Energy Solutions