HomeMy WebLinkAboutGN010.0 TSIIECC 2009 Performance Compliance
Property
1223 WESTVALE DR
CARMEL, IN 46032
Organization
TSI Energy Solutions
Matthew Timmons Inspection Status
Results are projected
JGW284 (AS DESIGNED) Builder
WESTVALE AT JACKSONS GRANT HOMES BY MCKENZIE, INC.
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Annual Energy Cost
IECC 2009 Performance
$1,808
$254
$385
$2,447
S1,359
SO
$3,806
Requirements
C4405.3
Performance-based compliance passes by 1.6%
402.4.1.2
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U -Factor
40322
Duct. Testing
C4
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
CTSI
Energy Solutions
As Designed
51,793
5230
5385
$2,408
S1,359
SO
$3,767
Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 1.6%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
2112119 at 6:32 AM
Ekotrope RATER - Version 3.1.0.2106
IECC 2009 Performance compliance results calculated usinq Ekotropes energy algorithm; which is a RESNET Accredited HERS Ratinq Tool.
1223 WESTVALE DR
CARMEL, IN 46032
HOMES BY McKENZIE, INC.
Ceiling Attic, R-50
Above Grade Walls R-15
Foundation Walls R-11
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.29, SHGC: 0.27
Building Features
Duct Supply R-6.0, Return R-6.0
Duct Leakage to Outside 230.0 CFM @ 25Pa
Total Duct Leakage 400.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 2/12/19 at 6:32 AM
Ekotrope RATER - Version 3.1.0.2106
No version of this software has been reviewed or approved by ICC or its affiliates.
The 2009 International Energy Conservation Code is a registered trademark of the International Code Council. Inc. ('ICC').
This software is a RESIN ETAccredited HERS Rating Tool.
Energy Code Inspection Checklist
Property
1223 WESTVALE DR
CARMEL, IN 46032
Organization
TSI Energy Solutions
Matthew Timmons
JGW284 (AS DESIGNED) Builder
WESTVALE AT JACKSONS GRANT HOMES BY McKENZIE, INC.
General Building Information
Conditioned Area (sq ft) 5,399
Conditioned Volume (cubic ft) 52,835
Insulated Shell Area (sq ft) 12,222
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
] Name: BSMT (1,916 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
] Name: CRAWL (779 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: FRAMED FLOOR (336 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
] Name: FIN (Exterior Perimeter [ft]: 113, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 10.595
Fully insulated (top to bottom)
] Name: UNFIN (Exterior Perimeter [ft]: 50, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 0.00
Fully insulated (top to bottom)
]l Name: CRAWL/AMB (Exterior Perimeter [ft]: 91, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2)
R: 10.00
Fully insulated (top to bottom)
Above Grade Wall
Energy Code Inspection Checklist
Property organization
1223 WESTVALE DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
JGW284 (AS DESIGNED) Builder
WESTVALE AT JACKSONS GRANT HOMES BY McKENZIE, INC.
Name: CONDIAMB (2,312 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CONDIGAR (440 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIATTIC (1,187 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
El Name: RIM CGNDIAMB (210 s.f.)
R: 11.691
Name: CGNDIGAR (44 s.f.)
R: 11.691
Name: CGNDIATTIC (193 s.f.)
R: 11.691
Roof
El Name: MAIN (2,856 s.f.)
R-39.73 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
El Name: SLOPED (209 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Opaque Door
Name: GARAGE (24 s.f.)
U: 0.182
Name: GARAGE (24 s.f.)
U: 0.182
Inspection Status
Results are projected
C",
Energy Solutions
2
Energy Code Inspection Checklist
C-M
Energy Solutions
Property Organization
1223 WESTVALE DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons Inspection Status
Results are projected
JGW284 (AS DESIGNED) Builder
WESTVALE AT JACKSONS GRANT HOMES BY McKENZIE, INC.
Glazing
11 Name: FRONT (67 s.f.), U:0.290, SHGC: 0.27, Orientation: EAST
11 Name: FRONT GD (48 s.f.), U:0.290, SHGC: 0.27, Orientation: EAST
E] Name: BACK (99 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST
E] Name: SLIDER (85 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST
E] Name: SLIDER (85 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST
E] Name: LEFT SIDE (75 s.f.), U:0.290, SHGC: 0.27, Orientation: SOUTH
El Name: RIGHT SIDE (121 s.f.), U:0.290, SHGC: 0.27, Orientation: NORTH
El Name: RIGHT SIDE BSMT (55 s.f.), U:0.290, SHGC: 0.27, Orientation: NORTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
0 HEATING 1 • Natural Gas • 60% Heating Load @ 92.1 AFUE
El HEATING 2 • Natural Gas • 40% Heating Load @ 92.1 AFUE
El AC 1 • Electric • 60% Cooling Load @ 13 SEER
El AC 2 • Electric • 40% Cooling Load @ 13 SEER
3
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Energy Code Inspection Checklist
Property
1223 WESTVALE DR
CARMEL, IN 46032
Organization
TSI Energy Solutions
Matthew Timmons
JGW284 (AS DESIGNED) Builder
WESTVALE AT JACKSONS GRANT HOMES BY McKENZIE, INC.
Air Leakage Control
Inspection Status
Results are projected
Test Status: Blower -door tested
House is air -sealed as to achieve 4,403 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
Entirely within conditioned space
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 230.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 400.0 CFM @ 25Pa
Duct System 2
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 47.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 136.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal Aelope.
There is no pass/fail threshold for duct leakage on the performance path.
Energy Code Inspection Checklist
Property
1223 WESTVALE DR
CARMEL, IN 46032
Organization
TSI Energy Solutions
Matthew Timmons Inspection Status
Results are projected
JGW284 (AS DESIGNED) Builder
WESTVALE AT JACKSONS GRANT HOMES BY McKENZIE, INC.
Project Notes
C",
Energy Solutions
5
Building Summary
Property
Organization
C-MEnergy Solutions
1223 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Inspection Status
JGW284 [AS DESIGNED]
Builder
Results are projected
WESTVALE AT JACKSONS GRANT 284
HOMES BY McKENZIE, JNC.
General Building Information
MM
Number Of Bedrooms
4
Number Of Floors
2
Conditioned Floor Area [sq. ft.]
5;399
Unconditioned, attached garage?
Yes
Conditioned Volume [cu. ft.]
52;835
Total Units in Building
1
Residence Type
Single family detached
Model
SAVADERtSCHRAQER RESIDENCE
Community
VVESTVALE AT JACKSONS GRANT 284
Climate Zone
5A
Basement Wall
Name Library Type
Height Above Grade Depth Below Grade Perimeter
Location Enclosing
CRAWLIAMB R-10 Draped, Full
1
2
91 Exposed Exterior Conditioned Crawlspace
FIN R-13 Finished, G1
1
8
113 Exposed Exterior Conditioned Space
UNFIN Uninsulated
1
8
50 Exposed Exterior Conditioned Space
Basement Wall Library List
Name Feet From Wali Top To Insulation
Feet From Wall Top To Insulation
Is Fully Insulated
R -value
Top
Bottom
R-10 Draped, Full
NIA
NIA
Yes
10.00
R-13 Finished, G1
NIA
NIA
Yes
10.595
Uninsulated
NIA
NIA
Yes
0.00
WeFibrmaryType Perimeter
Floor Grade
Carpet R Exposed
Surface Area
Location Enclosing
Masonry Area
BSMT Uninsulated
163 Below Grade
0 0
1,916.0 sq. ft.
Exposed Exterior Conditioned
Space
CRAWL Uninsulated
91 Below Grade
0
779.0 sq. ft.
Exposed Exterior Conditioned
Crawlspace
1
Building Summary
Property
1223 WESTVALE DR
CARMEL, IN 46032
JGW284 [AS DESIGNED]
WESTVALE AT JACKSONS GRANT 284
lab Library List
Name Wali C
Organization
TSI Energy Solutions
Matthew Timmons
Builder
HOMES BY McKENZIE, INC.
Inspection Status
Results are projected
C-M,
Energy Solutions
IUninsulated Woad Frame / Other
Framed Floor
Name Library Typ
R-38, GRI
Framed Floor Library List
Name
R-38, GR1
Rim Joist
Name
Library Type
CONDIATTIC
G1 R-15, OSB
CONDIGAR
G1 R-15, OSB
RIM CONDIAMB
G1 R-15. OSB
No 0 0 0 0.00
33.825
Rim Joist Library List
Name R-valw
G1 R-15, OSB 11.691
e
1 Above Grade
n
336.0 sq. Tt Unconditioned, attached
garage
Surface Area Location
193.0 sq. ft. Attic
44.0 sq. ft. Unconditioned, attached garage
210.0 sq. ft. Exposed Exterior
Building Summary
Property
1223 WESTVALE DR
CARMEL, IN 46032
JGW284 [AS DESIGNED]
WESTVALE AT JACKSONS GRANT 284
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
HOMES BY MCKENZIE, JNC.
TSI Energy Solutions
Name Library Type
surface color
surrace Area
Location
CONDIAMB G1 R-15 BATT, OSB
Medium
2,312.0 sq. ft.
Exposed Exterior
CONDIATTIC G1 R-15 BATT, OSB
Medium
1,187.0 sq. ft.
Attic
CONDIGAR G1 R-15 Gar Walls
Medium
440.0 sq. fl.
Unconditioned, attached garage
Wall Library List
Name
R value
G1 R-15 BATT, OSB
13.423
G1 R-15 Gar Walls
11.972
Glazing
Name Library Type Wall Assignment
Basement Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK U-29, SHGG27 CONDIAMB
0
0
0
West
99.0 sq. R
FRONT U-29, SHGC-.27 CONDIAMB
0
0
0
East
67.0 sq. R
FRONT GD U-29, SHGG27 CONDIAMB
0
0
0
East
48.0 sq. R
LEFT SIDE U-29, SHGG27 CONDIAMB
0
0
❑
South
75.0 sq. R
RIGHT SIDE U-29, SHGG27 CONDIAMB
0
0
❑
North
121.0 sq. 11
RIGHT SIDE BSMT U-29, SHGG27
FIN
0
0
❑
North
55.0 sq. fL
SLIDER U-29, SHGG27 CONDIAMB
0
0
0
West
85.0 sq. fL
SLIDER U-29, SHGG27 CONDIAMB
0
0
0
West
85.0 sq. ft
Glazing Library List
Name
Shg c
U -factor
U-29,SHGC-27
027
0290
3
Building Summary
Property
1223 WESTVALE DR
CARMEL, IN 46032
JGW284 [AS DESIGNED]
WESTVALE AT JACKSONS GRANT 284
kylight
Skylight Library List
Opaque Door
Organization
TSI Energy Solutions
Matthew Timmons
Builder
HOMES BY McKENZIE, JNC.
Inspection Status
Results are projected
C-M,
Energy Solutions
Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location
Assignment Ab sorpta n ce
GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 24.0 sq. ft Exposed Exterior
GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 24.0 sq. ft Exposed Exterior
Opaque Door Library List
Name
Steel Door
U -factor
0.182
Roof Insulation
-
Name
Library Type
Attic Exterior Area
Cray or Concrete Roof Surface Color
Surface Area
Location
P.f.]
Tiles
MAIN
R-50 Blown, GR1
2,856
No Medium
2,856.0 sq. ft
Attic
SLOPED
R-38 Vaulted, GR1
209
No Medium
2090.sq. 1
Attic
Roof Insulation Library List
Name Has
R-38 Vaulted, GR1
R-50 Blown, GR1
No 32.263
No 50.474
4
Building Summary
Property
1223 WESTVALE DR
CARMEL, IN 46032
JGW284 [AS DESIGNED]
WESTVALE AT JACKSONS GRANT 284
Whole House Infiltration
Infiltration
I5 ACH at 50 Pa
1
Mechanical Ventilation
Organization
TSI Energy Solutions
Matthew Timmons
Inspection Status
Builder Results are projected
HOMES BY MCKENZIE, JNC.
Blower -door tested 4
None Present
C-M,
Energy Solutions
Lighting
% Interior Fluorescent % Interior LED Lighting I Exterior Fluorescent % Exterior LED Lighting I Garage Fluorescent % Garage LED Lighting
Lighting Lighting Lighting
C
Onsite Generation
0
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
0
0
0
0
A
Building Summary
Property
Organization
C-MEnergy Solutions
1223 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Inspection Status
JGW284 [AS DESIGNED]
Builder
Results are projected
WESTVALE AT JACKSONS GRANT 284
HOMES BY MCKENZIE,
JNC.
conditioning Equipment
Name
Library Type
Heating Percent Load Coaling Percent Load
Hot Water Percent Load
AC 1
13ACX-042-230
0%
sc%
0%
AC 2
13ACX-042-230
0%
4C 1%
0%
HEATING 1 912SA4810OS17
60%
X11%
0%
HEATING 2 912SA4206OS17
40%
o°0
0%
Water Heating
RE350"
0%
0%
100%
Equipment Type: 13ACX-042-230
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSC (Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 41.5
■
Equipment Type: 912SA42060517
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 57
Use default EAE Yes
EAE [kWh] 736.1
Equipment Type: 912SA48100S17
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSC (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 93
Use default EAE No
EAE [kWh] 756
6
Building Summary
Property Organization
1223 WESTVALE DR TSI Energy Solutions
CARMEL, IN 460.32 Matthew Timmons
Inspection Status
JGW284 [AS DESIGNED] Builder Results are projected
WESTVALE AT JACKSONS GRANT 284 HOMES BY MCKENZIE, JNC.
quipment Type: RE350*
Forced Air
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
Distribution System
Distribution Type
Forced Air
Heating Equipment
HEATING 1
Cooling Equipment
AC 1
Sq. Feet Served
4611
# Return Grilles
3
Supply Duct R Value
6
Return Duct R Value
6
Supply Duct Area [sq. ft.]
1368.09
Return Duct Area [sq. ft_]
1266.75
Duct Leakage to Outdoors (CFM25)
230
Total Leakage
400
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Attic (well vented, under insulation)
Percent Supply Area
❑
Percent Return Area
❑
Duct 2
Duct Location
Conditioned Space
Percent Supply Area
100
Percent Return Area
100
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
C-M,
Energy Solutions
Building Summary
Property Organization
1223 WESTVALE DR TSI Energy Solutions
CARMEL, IN 460.32 Matthew Timmons
Inspection Status
JGW284 [AS DESIGNED] Builder Results are projected
WESTVALE AT JACKSONS GRANT 284 HOMES BY MCKENZIE, JNC.
istribution System
Distribution Type
Forced Air
Heating Equipment
HEATING 2
Cooling Equipment
AC 2
Sq. Feet Served
788
# Return Grilles
2
Supply Duct R Value
10
Return Duct R Value
20
Supply Duct Area [sq. ft.]
212.76
Return Duct Area [sq. ft_]
78.8
Duct Leakage to Outdoors (CFM25)
47
Total Leakage
136
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct t
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
95
Duct 2
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
5
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Ceiling Fan
'
Has Ceiling Fan
No
Cfm Per Watt
101
Water Distribution
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
75
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
30
Drain Water Heat Recovery?
No
C-M,
Energy Solutions
Building Summary
Property
1223 WESTVALE DR
CARMEL, IN 460.32
JGW284 [AS DESIGNED]
WESTVALE AT JACKSONS GRANT 284
Fuel Type
Cef
Field Utilization
lothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
"M
Organization
TSI Energy Solutions
Matthew Timmons
Builder
HOMES BY MCKENZIE, JNC.
Electric
Timer Controls
704 kWh/Year
0.0nWh
$23.00
$0.581Therm
2.874
0.33053
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
Inspection Status
Results are projected
C-M,
Energy Solutions
A